Tender For Repairs To Internal Wiring, Led Lights, Ceiling Fans Etc In Various Billets At Main Camp And Gj Area At Af Station Tambaram, tambaram-Tamil Nadu

Military Engineer Services-MES has published Tender For Repairs To Internal Wiring, Led Lights, Ceiling Fans Etc In Various Billets At Main Camp And Gj Area At Af Station Tambaram. Submission Date for this Tender is 28-12-2023. Electrification Work Tenders in tambaram Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40904758
Corrigendum : Tender For Repairs To Internal Wiring, Led Lights, Ceiling Fans Etc In Various Billets At Main Camp And Gj Area At Af Station Tambaram
Open Tender
Indian
Tamil Nadu
tambaram
28-12-2023

Tender Details

Repairs To Internal Wiring, Led Lights, Ceiling Fans Etc In Various Billets At Main Camp And Gj Area At Af Station Tambaram

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
INR 16 Lakhs /-

BOQ Items

Name of Work: REPAIRS TO INTERNAL WIRING, LED LIGHTS, CEILING FANS ETC IN VARIOUS BILLETS AT MAIN CAMP AND GJ AREA AT AF STATION TAMBARAM
Sl. No. Item Description
1Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, regulators, sockets etc to be measured seperately) and making good disturbed surface of wall, floors etc all as specified and directed.
2Point wiring complete with 1.50 sqmm single corePVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including PVC casing & caping/PVC conduiton walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled/surface in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly for the following :-
3All as per Item No 2 abovefor One light /fan pointcontrolled by one5 Amps switch.
4All as per Item No 2above but for One 3 pin 5 Amps socket outlet on same board
5All as per Item No 2 above but for One 3/5 pin 5 Ampssocket outlet on independent board
6All as per item No 2 above but for one 3/5 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
7All as per item No 2 above but for one 3/5 pin socket outlet 15 Amps independent with cable4 Sq mm size.
8Supply and fix in replacementSwitch piano flush type 5 Amps ,Single pole one way.
9Supply and fix in replacementSwitch socket flush type 2 in 1,5 pin 5 Amps 240 V
10Supply and fix in replacement Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal.
11Supply and fix in replacementFan regulator stepped type electronic flush/switch type, suitable for 1200mm /1400 mm sweep fan.
12Supply and fix in replacement PVC ceiling rose two to three terminal plate and jumbo type
13Supply and fix in replacementLamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
14Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 4""x4"" including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing all as specified and as directed.
15Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 6""x8"" including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing all as specified and as directed.
16Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 12"x8"" including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing all as specified and as directed.
17Supply and fix, in replacementMCB DB SPN double door, 4 way 240 V neutral link, earth link.all as specified and as directed.
18Supply and fix, in replacementof MCB DB SPN, double door, 8 way 240 V with 200 A rated bus bar neutral link, earth link all as specified and as directed.
19Supply and fix in replacementfor MCB DB TPN 4 wayvertical type double door complete including 200A rated copper bus bar, and netral and earth linksuitable with MCB TPN as incommer all as specified and as directed.
20Supply and fix in replacementfor MCB DB TPN 6 wayvertical type double door complete including 200A rated copper bus bar, and netral and earth linksuitable with MCB TPN as incommer all as specified and directed.
21Supply and fixing in replacementfor MCB SP 06 to 32 Amps, 10KA 240 volts,50Hz all as specified and as direcetd.
22Supply and fixing in replacement ofMCB SPN 05 to 40 Amps 10KA 240 volts all as specified and as direcetd.
23Supply and fixing in replacement ofMCB TP 63 Amps 10KA 415 volts as all as specified and as direcetd.
24Supply and fix in replacement ofMCB TPN 63 Amps 10KA 415 volts.all as specified and as directed.
25Supply and fix in replacement of MCB TP 100 Amps 10KA 415 volts all as specified and as directed.
26Supply and fix in replacement of Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volts all as specified and as directed.
27Supply and fix in replacement of MCCB 25 to 100 Amp 3 pole 16 KA breaking capacity 415 Volts all as specified and as directed.
28Taking down existingsub main wiring any description along with PVC conduit/ casing capping and made good the disturbed surface all as directed.
29M & L for circuit/sub main wiringcomplete with 2 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed.
30M & L for circuit/sub main wiringcomplete with 2 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 6 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as specified and directed. (Note for Sl items No.29 to 30 : Two runs of cable and one run of earth continuity cable shall be measured as one unit length)
31S & F in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driverwith 20 W LED 6500K (4 ft) lampincluding disconecting, removing,and connecting into electric circuit and testing all as per Havells Cat partNo.LUMILINE PLUS NEOBS20WLED865SPCSSIND(HSN CODE 9405)or Equivalent make from list of makes including testing all as directed by Engineer- in- charge. .
32Supply and fix in replacement of industrial compactbattensuitable fortwin LED tubelightincludingtwo nos of LED Tube light single side connectionwithvery high efficacy &THD15% all asspecified and direcetd . [(a)Cart part NoREGALBATTEN 8 UPTO 2X22WSSBSWH for fittingor Equivalent (b)Cart part No PHOTONULTRAE2.0123T8SSTL20WLED865SPC efficacy &THD <15% for LEDTubeor Equivalent ]
33Supply and fix in replacementTITANIA PLUS 2.0 ultra bright LED (Single side connection )with Aluminium insert/housing & veryhigheffocasy >120 lm/watt best suited for installation in existing tubelight luminare with G13 lamp holders to give glare free light as per Havells Cat partNo TITANIA PLUS 2.01213T8SSTL18WLED865SPC or Equivalentfrom list of makes including testing all as directed by Engineer- in- charge
34Supply and fix surface and wall mounted 10 Watt LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & intergrated electronic driver including LED lamp complete all as per Havells Cat No.LUMILINEBS10WLED865SPCWH or Equivalenet makefrom list of makes including testing all as directed by Engineer- in- charge.
35S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light sourcewith 25 W LED 5000K lampall as per Havells Cat No ENDURASUNDOWNSL25WLED765PASYBOPCIHD or equivalenet make from list of makes including disconecting, removing,and connecting into electric circuit including testing all as directed by Engineer- in- charge. .
36M&L GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50 M long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unserviceable GI bracket all as directed.
37Taking down carefully Existingceiling fan/exhaust fan//Air circulatorfan of any size/ Make after disconnecting the electrical connection etc.all as specified and directed
38Refixing/Instal only ceiling fan any size/make replacing the spares such as carterpin Unserviceable/Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor, painting , etc.And connectingup with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as Specified (Note:-Rewinding,spare parts suchas ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items..The Refixing fan shall be tested after fixing the blades)
39Refixing /Instal only Exhaust/aircirculator fans along with louvers any description any approval make,replacing the spares such as carterpin Unserviceable /Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor, paintingetc.And connectingup with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as Specified (Note:-Rewinding,spare parts suchas ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items..The Refixing fan shall be tested after fixing the blades)
40Material and labour for rewinding of fan motor with super enameled copper winding wire of same gauge and weight after cutting and removeing the existing burnt/heated up windings,including cleaning of rotor and varnishing,heating and providing fresh insulating Materials for the following size of fans/circulators :- ( a )Exhaust Fan 350 to 450mmSweep
41(b) All as per item No. 40 above , rewinding for Ceiling fan of 1200 mm sweep
42(c ) All as per item No. 40 above , rewinding for Air circulatorfan of 450 to 600 mm sweep
43Supply onlyball bearing size (6201/6202/6203) suitablefor ceiling fans size 1200/1400 mm Sweep
44Supply onlyball bearing Size (2001/2002/2003) suitablefor exhaust/wall fan/pedestal fan of any size and make
45Supply only capcitor of capacity 2.5 mfd for the ceilig fans
46Supply only capcitor of capacity 4 mfd for the fans
47Supply only GM bush suitable for ceiling fan of size 1200/1400 mm Sweep
48supply onlybush suitable for exhaust fans any make/size
49Taking downold double stiff pendent20 MM galvanised steel conduit complete .
50Supply and fixin repair Double stiff pendants, comprising of galvanised steel or chromium plated brass bell mouth connectors 2 Nos. with back plate and 2×1.50 metre long parallel 20mm dia galvanised or stove enamelled screwed steel conduit with two check nuts for fixing tube light fitting and upto 1.5 metre long twin core 0.5 sq mm copper conductor flexible wire/cable all as specied and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail