Tender For 8759 Special Repair, Replacement Of Amf Panels, Lt Panels Along With Connected Items At Certain Locations At Af Station Bareilly, bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For 8759 Special Repair, Replacement Of Amf Panels, Lt Panels Along With Connected Items At Certain Locations At Af Station Bareilly. Submission Date for this Tender is 16-12-2023. Electrical Panel Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40896056
Corrigendum : Tender For 8759 Special Repair, Replacement Of Amf Panels, Lt Panels Along With Connected Items At Certain Locations At Af Station Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
16-12-2023

Tender Details

8759 Special Repair, Replacement Of Amf Panels, Lt Panels Along With Connected Items At Certain Locations At Af Station Bareilly

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 89000.0 /-
Tender Value
INR 44.50 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR/ REPLACEMENT OF AMF PANELS/ LT PANELS ALONG WITH CONNECTED ITEMS AT CERTAIN LOCATIONS AT AF STATION BAREILLY
Sl. No. Item Description
1Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 2100mm (W) X1800mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 600 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
2The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
3PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 400 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 200 Amp-01 No. (ii) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 160 Amp-01 No. (iii) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 100 Amp-02 No. (iv) S & F MCCB 4 pole with breaking capacity 16 KA,fixed magnetic and fixed thermal setting (100% - 80%)50 Hz of rating 63 Amp-01 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED,YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 600/5, resin cast - 03 Nos.
4Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 500 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
5The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
6PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 320 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 25 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 160 Amp-02 No. (ii) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%)50 Hz of rating 100 Amp-01 No. (iii) S & F MCCB 4 pole with breaking capacity 16 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 63 Amp-01 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 600/5, resin cast - 03 Nos.
7Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 600 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
8The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
9PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 400 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 36 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 250 Amp-02 No. (ii) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 100 Amp-01 No. (iii) S & F MCCB 4 pole with breaking capacity 16 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 63 Amp-01 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 600/5, resin cast - 03Nos.
10Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 500 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
11The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
12PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 320 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 16 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 63 Amp-05 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 500/5, resin cast - 03 Nos.
13Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 600 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
14The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
15PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 400 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 36 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 250 Amp-01 No. (ii) S & F MCCB 4 pole with breaking capacity 25 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 160 Amp-02 No. (iii) S & F MCCB 4 pole with breaking capacity 25 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 100 Amp-01 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 600/5, resin cast - 03 Nos.
16Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 400 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
17The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
18PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 250 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 25 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 160 Amp-01 No. (ii) S & F MCCB 4 pole with breaking capacity 25 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 100 Amp-01 No. (iii) S & F MCCB 4 pole with breaking capacity 16 KA,fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 63 Amp-02 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 400/5, resin cast - 03 Nos.
19Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 2100mm (W) X1800mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 1000 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
20The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
21PROVISION FOR CABLE ENTRY :- The provision for cable entry/ exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for identification and crimped with tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S&F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 50 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 630 Ampere- 01 No. OUTGOING :- (i) S&F MCCB 4 pole, breaking capacity 36 KA, fixed magnetic and fixed thermal setting (100% - 80%)50 Hz of rating 250 Amp-03 No. (ii) S&F MCCB 4 pole with breaking capacity 25 KA fixed magnetic and fixed thermal setting (100% - 80%) , 50 Hz of rating 160 Amp-02 No. (iii) S&F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%)50 Hz of rating 100 Amp-03 No. (iv) S&F MCCB 4 pole with breaking capacity 16 KA,fixed magnetic and fixed thermal setting (100% - 80%)50 Hz of rating 63 Amp-01 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 1000/5, resin cast - 03 Nos.
22Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 500 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
23The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
24PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked identification and crimped with tinned copper lugs and wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 320 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole, breaking capacity 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 250 Amp-01 No. MAKE- LEGRAND or SCHNEIDER or ABB (ii) S & F MCCB 4 pole, breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 160 Amp-01 No (iii) S & F MCCB 4 pole, breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 100 Amp-01 No. MAKE- LEGRAND or SCHNEIDER or ABB (iv) S & F MCCB 4 pole, breaking capacity 16 KA, fixed magnetic and fixed thermal setting (100% - 80%)50 Hz of rating 63 Amp-01 No. MAKE- LEGRAND or SCHNEIDER or ABB MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 500/5, resin cast - 03 Nos.
25Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 600 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
26The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
27PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 400 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 160 Amp-01 No. (ii) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 100 Amp-03 No. (iii) S & F MCCB 4 pole with breaking capacity 16 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 63 Amp-01 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 600/5, resin cast - 03Nos.
28Design, supply, erection, testing and commissioning of outdoor type LT Panel of overall size not less than 1800mm (W) X1200mm (Ht)(Without Canopy & Base channel) x 450mm Depth, conforming to IS/IEC 61439 1 & 2, rated fault of 65KA, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 600 Amps insulated, Provision of Spreader link to both incoming and outgoingside ofMCCBsfor termination of cables; LT panel shall be duly fabricated in an approved fabrication house having modern fabrication and testing facility which includes at least seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY).
29The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with double layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
30PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables through and including cable gland made of Brass. CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) S & F 4 pole MCCB (with panel mounted rotary handle) with breaking capacity of 36 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 400 Ampere- 01 No. OUTGOING :- (i) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 160 Amp-01 No. (ii) S & F MCCB 4 pole with breaking capacity 25 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 100 Amp-02 No. (iii) S & F MCCB 4 pole with breaking capacity 16 KA, fixed magnetic and fixed thermal setting (100% - 80%) 50 Hz of rating 63 Amp-02 No. MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED- 01 set of 3 lamps (RED, YELLOW & BLUE) Digital Multifunction meter - 01 No. C.T having Ratio 600/5, resin cast - 03 Nos.
31Supply, installation, testing and commissioning for microprocessor based factory fabricated AMF control panel indoor type system suitable for 320 KVA DG set with and including internal wiring, free standing, floor mounted type, vertical type, front operated, dust & vermin proof & sound proof canopy fabricated out of 3.15mm thick MS CRCA sheet duly undergoing with pretreatment covering degreasing water rinsing, de-rusting/phosphating, After pre treating sheet metal shall be sprayed with high corrosion resistance primer and finally epoxy polyester power coating of flint grey shade. The panel consisting the following :-
32(i) Aluminium bus bars of suitable rating - 04 Nos with SMC/DMC support (ii)AC volt meter 0-500 volt, 96 mm x 96mm digital type with inbuilt selector switch - 01 No. (iii)AC Amp meter 0-400 volt, 96 mm x 96mm digital type with inbuilt selector switch - 01 No. (iv)Frequency meter 400 - 99.99 Hz, size 96 mm x 96mm digital type- 01 No. (v) Single lamp indicator (self running type) set of three(LED type)- 01 No. (vi)Battery charging indicator lamp - 01 No. (vii) Auto/ Manual/ Test switch - 01 No. (viii)Battery charging Amp meter and volt meter digital - 01 No. (ix)MCCB 04 pole with capacity 500 Amps ICU 36 KA for 415 volt, overload and short circuit protection three phase AC supply - 02 Nos. (x) Under/over voltage relay suitable for 3 phase 415 volt AC Supply - 02 Nos.(xi) Electronic timer, type ET suitable for 24 volts, DC supply as per recommendation of DG manufacturer DC supply for 0-10 second - 01 No. (xii) Electronic timer type suitable for 240 volts50 HzAC supply for 0-60 second ON relay -- 02 Nos.(xiii) Electronic timer suitable for 240 volts 50 Hz, AC supply for 0-60 second OFF relay -- 01 No.(xiv) Engine starting relay with sequence timer & master timer suitable for 24 volt DC supply as per recommendation of DG manufacturer - 01 No. (xv)Battery charging transformer 24 volt DC as per recommendation of DG manufacturer - 01 No. (xvi)Bypass arrangement with rotary type bypass change over switch of capacity 630 Amp AC on load to isolate the AMF panel at the time of low voltage. (xvii) Four pole power contactor with standard coil voltage of 415 volt 50 Hz and auxiliary contact of 02 Nos having AC three phase rating 500 Amp MNX series type.02 No. (xviii)Booster relay of 24 volt capacity -- 01 No. (xix)provision of protection against single phasing & phase reversal.
33Supply, installation, testing and commissioning for microprocessor based factory fabricated AMF control panel indoor type system suitable for 200 KVA DG set with and including internal wiring, free standing, floor mounted type, vertical type, front operated, dust & vermin proof & sound proof canopy fabricated out of 3.15mm thick MS CRCA sheet duly undergoing with pretreatment covering degreasing water rinsing, de-rusting/phosphating, After pre treating sheet metal shall be sprayed with high corrosion resistance primer and finally epoxy polyester power coating of flint grey shade. The panel consisting the following :-
34(i) Aluminium bus bars of suitable rating - 04 Nos with SMC/DMC support (ii)AC volt meter 0-500 volt, 96 mm x 96mm digital type with inbuilt selector switch - 01 No. (iii)AC Amp meter 0-400 volt, 96 mm x 96mm digital type with inbuilt selector switch - 01 No. (iv)Frequency meter 400 - 99.99 Hz, size 96 mm x 96mm digital type- 01 No. (v) Single lamp indicator (self running type) set of three(LED type)- 01 No. (vi)Battery charging indicator lamp - 01 No. (vii) Auto/ Manual/Test switch - 01 No. (viii)Battery charging Amp meter and volt meter digital - 01 No. (ix)MCCB, 04 pole with capacity 320 amps ICU 36 KA for 415 volt, overload and short circuit protection three phase AC supply - 02 Nos. (x) Under/over voltage relay suitable for 3 phase 415 volt AC Supply - 02 Nos. (xi) Electronic timer type ET suitable for 24 volts, DC supply as per recommendation of DG manufacturer DC supply for 0-10 second - 01 No. (xii) Electronic timer type suitable for 240 volts50 HzAC supply for 0-60 second ON relay -- 02 Nos.(xiii) Electronic timer type suitable for 240 volts 50 Hz, AC supply for 0-60 second OFF relay -- 01 No.(xiv) Engine starting relay with sequence timer & master timer suitable for 24 volt DC Supply as per recommendation of DG manufacturer --- 01 No. (xv)Battery charging transformer 24 volt DC as per recommendation of DG manufacturer --- 01 No. (xvi)Bypass arrangement with rotary type bypass change over switch of capacity 400 Amp AC on load to isolate the AMF panel at the time of low voltage. (xvii) Four pole power contactor with standard coil voltage of 415 volt 50 Hz and auxiliary contact of 02 Nos having AC three phase rating 320 Amp MNX series type.02 No. (xviii)Booster relay of 24 volt capacity -- 01 No. (xix)provision of protection against single phasing & phase reversal.
35Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 240 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
36Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 185 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
37Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked of size 150 Sq.mm 3.5 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
38Horizontal Boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes up to 100 mm bore and making good the disturbed surface complete all as specified and as directed. Note: GI pipe will be measured and paid separately.
39S&F GI tubes 100 mm bore dia light grade with all fittings laid in trenches or inserting in horizontal boring complete all as specified and as directed.
40Excavation in trenches (manually) not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables or foundation of electric pole / Stay assembly and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
41Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick in any type of soil complete all as specified and as directed.
42Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed.
43M&L for laying of course sand free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required complete all as specified and directed. Note:- Punned down thickness shall be measured for payment purpose.
44M&L for sub class "B" brick for covering to under ground cable laid flat transversally width equal to the length of the cable complete all as specified and directed.
45Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 16 of tender document i.e. Rs. 89,600.00