| 1 | Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50 meter including all lifts, laying in layers of 20 centimeter to 30 centimeter thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller to achieve not less than 97 percent of standard proctor density et-cetra complete ( Material obtained from departmental Land) |
| 2 | Excavation for foundationin earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directedet-cetra complete. ( By Mechanical Means ) a) Upto 1.50 meter lift Normal Rate b) 1.50 meter to 3.00 meter lift, Add 10 percent. c) 3.00 meter to 4.50 meter lift, Add 20 percent d) 4.50 meter to 6.0 meter lift, Add 30 percent. |
| 3 | Providing rubble filling of trap or granite or quartzite gneiss stones for foundations including filling voids with sand or grit and compaction et-cetra complete. |
| 4 | Providing and laying in situ or ready mix cement concrete of Mix-15 proportion with trap or granite or quartzite or gneiss metal in foundation including necessary form work, compacting and curing et-cetra complete. (with reversible drum type mixer without Supervisory control and data acquisition with fine agreegates of required specifications (Natural sand or Vertical Shaft Impact sand finely washed et-cetra) |
| 5 | Providing and laying cement concrete pipe of Indian Standard 458:2003 Non Pressure-2 class of 900 milimeter diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing et-cetra complete. |
| 6 | Providing cast in situ or ready mix Mix-20 grade cement concrete for head walls of Cross Drainag work or retaining walls et-cetra including necessary form work, compaction, finishing and curing et-cetra complete. (with reversible drum type mixer or concrete batch mix plant (pan mixer)without Supervisory control and data acquisition. |
| 7 | Providing and laying weep holes of 100 milimeter diameter Polyvinyl chloride pipes as per drawing for abutment returns, return walls et-cetra Complete. |
| 8 | Providing and laying in situ or ready mix Mix-20 cement concrete of trap metal for approach slab or Rigid pavement including compacting, finishing, curing etc. complete. (excluding reinforcement) (with reversible drum type mixer or concrete batch mix plant (pan mixer)without Supervisory control and data acquisition with fine agreegates of required specifications (Natural sand or Vertical Shaft Impact sand finely washed et-cetra), cement 6.40 bags per cubic meter) |
| 9 | Providing and fixing stream lined Mix-20 grade Reinforced Cement Concrete guard stone including mild steel bar reinforcement et-cetra complete. |
| 10 | Providing selected hard murum filling including laying in layers of 15 to 20 centimeter with watering and compacting et-cetra complete. |
| 11 | Road diversion et-cetra complete. |
| 12 | Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader or Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material |
| 13 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -GradingI(Using Screening Type B (11.2 milimeter) Aggregate) |
| 14 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II(Using Screening Type B (11.2 milimeter) Aggregate) |
| 15 | Providing and constructing 75 milimeter thick ModifiedPenetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 milimeter stone metal layers 100 percent crusher broken metal with conical crusher plant heating and spraying thebitumen of specified grade at 2 Kg per square meter, spreading 12 milimeter size chips compacting with three wheel static roller having weight 8 to 10 Metric Tonne to achive the desired degree of compaction as per Technical Specification Clause 506 et-cetra complete.Including picking of existing Water Bound Macadam surface. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates) |
| 16 | Open Graded Premix Surfacing- Providing and Laying Open Graded Carpet 20 milimeter thickness composed of 13.2 milimeter to 5.6 milimeter aggregates premixed with bituminous binder transported to site with Vehicle Tracking System, laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but including Tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant withtout Supervisory control and data acquisition, Paver and Vibratory roller ( Over Modified Penetration Macadam Surface) (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates) |
| 17 | Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of specified gradepreparing existing road surface, heating and applying bitumen at 0.98 Kilogram Square meter by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 Metric Tonne et-cetra complete. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates) |
| 18 | Supplying hard murum or kankar at the road site, including conveying and stacking complete. |
| 19 | Spreading hard murum or soft murrum or gravel or kankar for side width complete. |
| 20 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering et-cetra complete. |
| 21 | Excavation for catch or side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils. |
| 22 | Labourchargesforremovinggrass,thorneyshrubs,Junglishrub,Kubabulandalikegrass along roadside making the ground clean by showel and phavaras et-cetra complete. |
| 23 | Providing and fixing Reinforced Cement Concrete 200 metre stones as per Indian Road Congress standard including fixing in standard size in Cement Concrete 1:4:8 block including curing, painting lettering et-cetra complete. |
| 24 | Providing and Fixing 1:2:4 Ordinary kilometer stones as per Indian Road Congress standard including fixing in standard size in Cement Concrete 1:4:8 block including curing, painting lettering et-cetra complete. |
| 25 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period et-cetra\", having rectangular shape of 1.20 meter x 0.90 meter size made out 18 gauge (1.25 milimeter)thickmildsteelsheetpaintedwithonecoatofZincchromatestovingprimerandtwocoatsof enamelpaintonfrontside andgreystove enamelonbackside andborder or messages or symbolset-cetrawith approved colour shade paint complete, on Mild Steel angle of size 35 x 35 x 3 milmeter frame with properly cross braced Mild Steel angles of size 35 milimeter x35 milimeter x 3 milmeter duly painted including Two Mild Steel angle iron posts of size 65 milmeter x 65 milmeter x 6 milimeter, 3.65 meter long painted with alternate black and white bands of 25 centimeter width including all fixtures et-cetraandfixingtheboardsin1:4:8concreteblockofsize60centimeterx60centimeterx75centimeterincluding,excavation, refilling, transportation, and labour et-cetra complete. |