Tender For Repair And Modification Of Ops Room Of Hq Igar(N) At Kohima, kohima-Nagaland

Assam Rifles-AR has published Tender For Repair And Modification Of Ops Room Of Hq Igar(N) At Kohima. Submission Date for this Tender is 06-12-2023. Machine Tools Tenders in kohima Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

40883671
Tender For Repair And Modification Of Ops Room Of Hq Igar(N) At Kohima
Open Tender
Indian
Nagaland
kohima
06-12-2023

Tender Details

Tender For Repair And Modification Of Ops Room Of Hq Igar ( N ) At Kohima; 1 Schdule -A Part -I ( Repair & Modification Of Ops Room ) 2 Dismantling Tile Work In Floorslaid In Cement Mortar Including Stacking Material Within 50 Metres Lead. 3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. 4 Demolishing Brick Work In Cement Mortermanually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. 5 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 6 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 7 Reinforced Cement Concrete Work 1:1.5:3 With 20 Mm Graded Stone Aggregatein Columns, Pillars, Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement 8 Reinforced Cement Concrete Work 1:1.5:3 With 20 Mm Graded Stone Aggregatein Beam / Intels, Bands Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement 9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, 10 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams 11 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 12 Providing 20 Mm Cement Plaster Of Mix :1:6 ( 1 Cement: 6 Coarse Sand ) On Brick Wall Internally 13 Providing 20 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 6 Coarse Sand ) On Brick Wall Externally 14 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With 12.5 Mm Thick Tapered Edge Gypsum Moisture Resistant Board 15 Providing And Laying Vitrified Floor Tiles Of Size800x800 Mm ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 16 Providing And Laying Vitrified Tiles In Floor In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Includinggrouting The Joints With White Cement And Matching Pigments Etc. Glazed Vitrified Tiles Matt / Antiskid Finish Of Size 800 X 800 Mm 17 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, Inskirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 800X800 Mm 18 Providing And Fixing Factory Made Upvc White Colour Sliding Glazed Window Above 1.50 M In Height Dimension Comprising Of Upvc Multi-Chambered Frame With In-Built Roller Track And Sash Extruded Profiles Duly Reinforcedwith 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length ( Shape & Size According To Upvc Profile ) , Appropriate Dimension Of Upvc Extruded Glazing Beads, Upvc Extruded Interlocks And Upvc Extruded Inline Sash Adaptor ( If Required ) , Epdm Gasket, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. ( Single / Double Glass Panes, Wire Mesh And Silicon Sealent Shall Be Paid Separately ) .Two Track Two Panels Sliding Window Made Of ( Big Series ) Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm 19 Providing And Fixing Glazing In Upvc / Aluminium , Window Shutterswith Epdm Rubber / Neoprene Gasketetc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) :With Float Glass Panes Of 4.00 Mm Thickness 20 Providing And Fixing Fiber Glass Reinforced Plastic ( Frp ) Door Frames Of Cross-Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15Mm To Receive Shutter Of 30 Mm Thickness. The Laminate Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. ( Isi Marked ) 21 Providing & Fixing 30 Mm Thick Fiberglass Reinforced Plastic ( F.R.P. ) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam ( Puf ) / Polystyrene Foam To Be Used As Filler Material Throughout The Hollow Panel, Casted Monolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is: 14856, Complete As Per Direction Of Engineer-In-Charge. ( Isi Marked ) 22 Steel Work In Built Up Tubular ( Square Or Rectangular Hollow Tubes Etc. ) Trusses / Post Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. 23 S&F Of Rolled Mild Steel Sectioncleat And Gusset Plates, Base Plateetc End Support Of Purlin Etc 24 S & F Mild Steel Bolts, Purpose Made With Hexagonal Or Square Head One End And Screwed The Other, Or Screwed Both Ends Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Exc 30Cm Long 25 Fixing Onlyof Pre-Coated Galvanized Iron Profilesheet Sheathing With Two Corrugation Side Lap Fixed With Screw With Washer To Roof 0.50Mm ( Fixing With Self Tapping Screws ( Ppg Sheet Will Be Issued As Free For Fixing From Cp Store ) 26 Finishing With Deluxe Multi Surface Paintfor Interiorsusing Primer As Per Manufacturers Specifications :Two Or More Coats Applied On Walls @ 1.25 Ltr / 10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr / 10 Sqm 27 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 28 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wallsurface To Prepare The Surface Even And Smooth Complete 29 Providing And Fixing 35 Mm Thick Factory Made Laminated Veneer Lumber Door Shutter Conforming To Is : 14616 And Tads 15:2001 ( Part B ) , Fixingwith Butt Hinges Of Required Size With Necessary Screws, All Complete As Per Directions Of Engineer- In-Charge And Panelling With Panels Of :12 Mm Thick One Side Pre-Laminated Particle Board ( Decorative Lamination On One Side And Other Sides Balancing Lamination ) ( Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately ) 30 Providing Wood Work In Frames Of Doors, And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) .Kiln Seasoned And Chemically Treated Hollock Wood 31 M / L For Second Class Hard Wood Weather Board 20 Mm Thick 200 Mm Wide 32 Schedule‘A’ Part-Ii ( Electrification Of Ops Room ) 33 Wiring For Light Point / Fan Point / Exhaust Fan Point / 5 Amps Socket Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Concealed Wiring In Pvc Conduit 34 Wiring For Light / Power Plug With 4X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 2 Nos. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 35 Supplying And Fixing Following Modular Switch On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 A Switch 36 Supplying And Fixing Following Modular Switch On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 A Switch 37 Supplying And Fixing Following Modularsocket On The Existing Modular Plate & Switch Box Including Connections Butexcluding Modular Plate Etc. As Required.3 Pin 5 / 6 A Socket Outlet 38 Supplying And Fixing Following Modular Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 A Socket Outlet 39 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc.As Required. 6 Module ( 200Mmx75mm ) 40 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 8 Module ( 125Mmx125mm ) 41 Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc.As Required. 42 Supply & Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.300 Mm Sweep 43 Supply & Fixing Led Ceiling Light Fittings 9 Watts Of Approved Make ( Phillips / Hevells ) 44 Supply & Fixing Led Focus Lamp Fittings90 Watts Of Approved Make ( Phillips / Hevells ) 45 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) . 6 Way ( 4 + 18 ) , Double Door 46 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) . 8 Way ( 4 + 24 ) , Double Door 47 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, CCurve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 48 Ditto But Single Pole And Neutral 49 Ditto But Double Pole 50 Ditto But Triple Pole 51 Ditto But Triple Pole And Neutral 52 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 A 53 S / F 1100 Volts Grade Heavy Duty Cable Pvc Insulatedcopper Conductor Cable , Served With Inner Sheathing Of Pvc Tape And Over All Pvc Sheathed In Service Connection Suspended By Insulating Hanger Not More Than One Meter Apart Incl 4Mmdiagi Suspension Wire, Two Single Core 16 Sqmm Wire. 54 M / L For Earthing Complete With Galvanized Steel Earth Lead Electrode 60 Cm X 60 Cm X 6.3Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Meter Deep Below Ground Level ) With Top Edge Of The Plate Not Less 1.50 Meter Below Normal Ground Level , Connected To Galvanized Earth Lead 25 X 5 Mm Gi Strip 3.00Mtrs Long By Means Of Bolts, Nuts, Check Nuts And Washers All As Shown In Electrical Plate No.5 And Testing On Completion. 55 M / L For Earthing Chamber With Pcc 1:2:4 Type B1 Inclci Cover Etc All Complete. 56 S / F Ceiling Rose , Surface Bakelite, 65X 50 Mm , Two To Three Terminals. 57 S / F Switch Fuses, Iron Clad Or Ofsheet Metal Tp Fused And Neutral Link 63 Amps 415 Volts 58 Schedule‘A’ Part-Iii ( Water Supply & Sanitary Fittings ) 59 Construction Of 01 No 20 User Septic Tank All As Per Specification And Drawing No. Igar ( N ) / 2022 / 09 / Std Sheet No.1 / 1 60 Construction Of 01 No Soak Pitall As Per Specification And Drawing No. Igar ( N ) / 2022 / 10 / Std Sheet No.1 / 1 61 Construction Of 01 No Man Hole, Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame ( Light Duty ) 62 Supplying And Fixing Ewc With Built In Cistern, Model No- Make- Jaquar, Rimless Single Piece Wc, Ops-Wht-15853S300uf Model Of Jaquar 63 Providing & Fixing Bath Room Mirror Of Size , 1500X600 Mm Size ( 5Mm Thick ) 64 Providing & Fixing Towel Rack With Lower Hanger , Model Ahs-1581H ( Jaquar ) 65 Providing & Fixing Single Lever Basin Mixer Tail Body . Model-Kup-35005-Bpm ( Jaquar ) 66 Providing & Fixing Soap Dish. Model-Aqn-7731 ( Jaquar ) 67 Providing & Fixing Corner Glass Shelf With Bracket, Acn-1173 ( Make-Jaquar ) 68 Providing & Fixing Toilet Paper Holder. Model No-Can-1151N ( Jaquar ) 69 Providing & Fixing Cp Angle Stop Cock. Model No-Con-053Kv ( Jaquar ) 70 Bib Cock With Wall Flange, Model No-Ari-39037 ( Make-Jaquar ) 71 Two Way Bib Cock With Wall Flange. Model No-Ari-39041 ( Jaquar ) 72 Hand Shower ( Health Faucet ) With 8Mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook Withn.R.V ( Back Flow Preventer ) Jaquar- Model No-Ald-577 73 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes 25 Mm Dia, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Completeas Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall ( Isi Marked ) 74 Ditto, But Concealed Work, Including Cutting Chases And Making Good The Walls Etc.20 Mm Nominal Dia Pipes ( Isi Marked ) 75 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion 110 Mm Diameter ( Isi Marked ) 76 Ditto But 75 Mm Dia Pvc Pipe ( Isi Marked ) 77 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Whb Platforms And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement.Granite Stone Slab Colour Black

Key Value

Document Fees
INR 1000 /-
EMD
INR 58000.0 /-
Tender Value
INR 28.95 Lakhs /-

BOQ Items

Name of Work: Repair and Modification of OPs Room of HQ IGAR(N) at Kohima
Sl. No. Item Description
1Schdule -A Part -I( Repair & Modification of Ops Room)
2Dismantling tile work in floorslaid in cement mortar including stacking material within 50 metres lead.
3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
4Demolishing brick work in cement mortermanually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
5Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
6Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
7Reinforced cement concrete work 1:1.5:3 with 20 mm graded stone aggregatein columns,pillars,etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
8Reinforced cement concrete work 1:1.5:3 with 20 mm graded stone aggregatein Beam /intels,bands etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
9Centering and shuttering including strutting, propping etc. and removal of form for Columns,
10Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams
11Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
12Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) on brick wall internally
13Providing 20 mm cement plaster of mix :1:4 (1 cement: 6 coarse sand) on brick wall Externally
14Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre,all as per manufacturer"s specification and also including the cost of making openings for light fittings,all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board
15Providing and laying vitrified floor tiles of Size800x800 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
16Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Glazed Vitrified tiles Matt/Antiskid finish of size 800 x 800 mm
17Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800x800 mm
18Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required),EPDM gasket,all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately).Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm
19Providing and fixing glazing in uPVC/ aluminium , window shutterswith EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions of engineer-in-charge(Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.00 mm thickness
20Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. (ISI Marked)
21Providing & fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.(ISI Marked)
22Steel work in built up tubular ( square or rectangular hollow tubes etc.) trusses/post etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.
23S&F of rolled mild steel sectioncleat and gusset plates, base plateetc End support of purlin etc
24S & F mild steel bolts, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long
25Fixing onlyof Pre-coated galvanized iron profilesheet sheathing with two corrugation side lap fixed with screw with washer to roof 0.50mm (fixing with self tapping screws ( PPG Sheet will be issued as free for fixing from CP store)
26Finishing with Deluxe Multi surface paintfor interiorsusing Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
27Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
28Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
29Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of :12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) (Note:- Butt hinges and necessary screws shall be paid separately)
30Providing wood work in frames of doors, and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Kiln seasoned and chemically treated hollock wood
31M/L for second class hard wood weather board 20 mm thick 200 mm wide
32SCHEDULE‘A’ PART-II (Electrification of OPs Room)
33Wiring for light point/ fan point/ exhaust fan point/ 5 amps socket point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Concealed Wiring in PVC conduit
34Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
35Supplying and fixing following modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
36Supplying and fixing following modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
37Supplying and fixing following modularsocket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
38Supplying and fixing following modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
39Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required. 6 Module (200mmX75mm)
40Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
41Installation, testing and commissioning of pre-wired,fluorescent fitting including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
42Supply & Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.300 mm sweep
43Supply & Fixing LED Ceiling light fittings 9 watts of approved make ( Phillips/ Hevells)
44Supply & Fixing LED Focus lamp fittings90 watts of approved make ( Phillips/ Hevells)
45Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way (4 + 18), Double door
46Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door
47Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
48Ditto but Single pole and neutral
49Ditto but Double pole
50Ditto but Triple pole
51Ditto but Triple pole and neutral
52Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
53S/F 1100 volts grade heavy duty cable PVC insulatedCopper conductor cable , served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than one meter apart incl 4mmdiaGI suspension wire, Two single core 16 Sqmm wire.
54M/L for earthing complete with galvanized steel earth lead electrode 60 Cm x 60 Cm x 6.3mm thick, buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less 1.50 meter below normal ground level , connected to galvanized earth lead 25 x 5 mm GI strip 3.00mtrs long by means of bolts, nuts, check nuts and washers all as shown in electrical plate No.5 and testing on completion.
55M/L for earthing chamber with PCC 1:2:4 type B1 inclCI cover etc all complete.
56S/F Ceiling rose , surface bakelite, 65x 50 mm , two to three terminals.
57S/F switch fuses, iron clad or ofsheet metal TP fused and neutral link 63 amps 415 volts
58SCHEDULE‘A’ PART-III (Water Supply & Sanitary Fittings)
59Construction of 01 No 20 User Septic Tank all as per specification and drawing No. IGAR(N)/2022/09/STD sheet No.1/1
60Construction of 01 No Soak Pitall as per specification and drawing No. IGAR(N)/2022/10/STD sheet No.1/1
61Construction of 01 No Man hole, Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
62Supplying and fixing EWC with built in Cistern,Model No- Make- Jaquar,Rimless Single Piece WC, OPS-WHT-15853S300UF Model of Jaquar
63Providing & Fixing Bath room mirror of Size , 1500x600 mm size (5mm thick)
64Providing & fixing Towel Rack with Lower hanger , Model AHS-1581H (Jaquar)
65Providing & fixing Single Lever Basin Mixer Tail Body . Model-KUP-35005-BPM (Jaquar)
66Providing & fixing Soap Dish. Model-AQN-7731 (Jaquar)
67Providing & fixing Corner Glass Shelf with bracket, ACN-1173 (Make-Jaquar)
68Providing & fixing Toilet Paper Holder. Model No-CAN-1151N (Jaquar)
69Providing & fixing CP Angle Stop Cock. Model No-CON-053KV (Jaquar)
70Bib Cock with Wall Flange, Model No-ARI-39037 (Make-Jaquar)
71Two Way Bib Cock with Wall Flange. Model No-ARI-39041 (Jaquar)
72Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook withN.R.V (Back Flow Preventer) Jaquar- Model No-ALD-577
73Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 25 mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (ISI Marked)
74Ditto,but Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes (ISI Marked)
75Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 110 mm diameter(ISI Marked)
76Ditto but 75 mm dia PVC pipe(ISI Marked)
77Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for WHB platforms and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement.Granite stone slab colour black