Extension Of Ht/Lt Line Including Distribution Transformer In Turnkey Basis(Partial) For Energisation Of Dtw Scheme At Different Locations Of B.C.Nagar, Rajnagar & Hrishyamukh R.D Block Under The Jurisdiction Of Ed Belonia, belonia-Tripura

Tripura State Electricity Corporation Limited-TSECL has published Extension Of Ht/Lt Line Including Distribution Transformer In Turnkey Basis(Partial) For Energisation Of Dtw Scheme At Different Locations Of B.C.Nagar, Rajnagar & Hrishyamukh R.D Block Under The Jurisdiction Of Ed Belonia. Submission Date for this Tender is 12-12-2023. Distribution Transformer Tenders in belonia Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

40883071
Corrigendum : Extension Of Ht/Lt Line Including Distribution Transformer In Turnkey Basis(Partial) For Energisation Of Dtw Scheme At Different Locations Of B.C.Nagar, Rajnagar & Hrishyamukh R.D Block Under The Jurisdiction Of Ed Belonia
Open Tender
Indian
Tripura
belonia
12-12-2023

Tender Details

Extension Of Ht / Lt Line Including Distribution Transformer In Turnkey Basis ( Partial ) For Energisation Of Dtw Scheme At Different Locations Of B.C.Nagar, Rajnagar & Hrishyamukh R.D Block Under The Jurisdiction Of Ed Belonia

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Dec-2023 Modification of percentage of annual turnover Other 12-12-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 445989.0 /-
Tender Value
INR 2.22 Crore /-

BOQ Items

Name of Work: Extension of HT/LT line including distribution Transformer in turnkey basis(Partial) for energisation of DTW scheme at different locations of B.C.Nagar, Rajnagar & Hrishyamukh R.D Block under the jurisdiction of ED Belonia.
Sl. No. Item Description
1Supply of the followings
29.0 mtr. Long PCC Pole
38.0 mtr. Long PCC Pole
4Stay set HT complete with 16 mm dia 1.8 mtr stay rod, anchor
5Stay set LT complete with 16 mm dia 1.8 mtr stay rod, anchor
6Galvanised stay wire
7Stay Insulator(HT)
8Stay Insulator(LT)
9Supply of 0.3 mtr. long 75 X 40 X 40 X 6 mm. MS channel
10Supply of 1.2 mtr. long 75 X 40 X 40 X 6 mm. MS channel
11Supply of 1.5 mtr. long 65 X 65 X 6 mm. MS angle
12Supply of 2.2 mtr long 75X40X40X6mm M.S. Chanel
13Supply of 2.5 mtr. long 65 X 65 X 6 mm. MS angle
14Supply of 2.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel
15Supply of 0.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel
16Supply of 2.8 mtr. long 75X40X40X6 mm. MS channel
17Supply of 2.8 mtr. long 65 X 65 X 6 mm. MS angle
18Suppy of 1.5 mtr long 75X40X40X6 mm MS channel
19Supply of 1.6 mtr. long 65 X 65 X 6 mm. MS angle
20Supply of 11 KV 320 mm CD Polymer composite Pin Insulator as per the direction of the engineer In- Charge
21Supply of 11 KV Polymeric Disc Insulator with fittings, nuts & bolts, washers etc. as required
22Supply, testing, erection and commissioning of ACSR Weasel ConductorforjumperingincludingPGClamps,bi-metallic connectors, hardware etc as per Drawing & Scope of works as required as per IS.Technical Specification, approved
23Supply of 8 SWG GI wire for gaurding/earthing as per technical specifications as required as per IS.
24Bi-metalic Lugs 95 sq mm
25Bi-metallic Lugs 50 sq. Mm.
2670 Sqmm PVC cable as per the technical specifications, IS.
2716 Sqmm PVC cable as per the technical specifications, IS.
28Supply of fabricated M.S clamp made of 50X6 mm MS flat for fitting fixing of stay set, substation & line erection.
29Triple pole (3 phase), 12 KV, 200 Amp. GOS unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer-In-charge.
30Triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer"s In-charge.
319 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply Nominal Creepage distance 300mm. conforming to ISS:3070/1985 as per the direction of the Engineer"s In-charge.
32Supply & erection of Wooden Plunk karai wood (L-9", Breath-1.5", thickness-1.5")
33LT Shackle Insulators (4X4.5)? with straps & bolts.
34Supply of Nuts & bolts of assorted size.
35100 Amps kit kat Cut-out as per Technical specifications.
36Erection of the followings
379.0 mtr. Long PCC Pole
388.0 mtr. Long PCC Pole
39GI stay set HT 20 SQMMi/c Stay wire (6.0 Kg) , Stay Insulator(1 No), Clamps 50 x 6 mm(4 Nos), Nuts & bolts(2Nos) for HT
40GI stay set HT 20 SQMMi/c Stay wire (6.0 Kg) , Stay Insulator(1 No), Clamps 50 x 6 mm(4 Nos), Nuts & bolts(2Nos) for LT
410.3 mtr. long 75 X 40 X 40 X 6 mm. MS channel cross arm on steel tubular pole or PCC pole or RS joist with 1 (one) no. clamp of 50x6 mm. MS flat, nuts and bolts as required. 2.16 Kg @ 69.36/- KG
421.2 mtr. long 75 X 40 X 40 X 6 mm. MS channel cross arm on single steel tubular pole or PCC pole or RS joist including supply with (i)1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required8.64 Kg @69.36/- KG
431.5 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
442.2 mtr long 75X40X40X6mm M.S. Chanel cross arms on PCC /S.T poles with M.S. Clamps, nuts and Bolts etc as required. 15.84 Kg @69.36/- KG
452.5 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Double steel tubular pole or PCC pole or RS joist structure including supply with (i) 2 (two) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 14.5 Kg @69.36/- KG
462.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support and supply with (i) 2 (two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 26.6 kg @69.36/Kg
470.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support and supply with (i) 2 (two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 6.80 kg @69.36/Kg
482.8 mtr. long 75X40X40X6 mm. MS channel bracket for G.O.S & D.O. fuse unit on double steel tubular pole or PCC pole including supply of i) 2(two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 20.16 kg @69.36/Kg
492.8 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
501.5 mtr. long 75 X 40 X40X6 mm. MS Channel cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
511.6 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
52Erection of 11 KV 320 mm CD Polymer composite Pin Insulator as per the direction of the engineer In- Charge
53Erecion of 11 KV Polymeric Disc Insulator with fittings, nuts & bolts, washers etc. as required
54Erection, testingand commissioning of ACSR Weasel ConductorforjumperingincludingPGClamps,bi-metallic connectors, hardware etc as per Drawing & Scope of works as required as per IS.Technical Specification, approved
55Erection, testing and commissioning of 8 SWG GI wire for gaurding/earthing as per technical specifications, approved drawings and scope of works. as required as per IS.
56Erection of protective Guard/ Cross lacing for 11 KV line GI wire 8/10 SWG as per the technical specification
57Providing pipe earthing with supply of 2.5 mtr long 40 mm Dia GI pipe (Jindal/TATA make) including supply of salt & charcoal(Salt 60 Kg, Charcoal 55Kg) along with excavation, refilling with alternative layer of salt & charcoal etc as required including connectivity with Transformer Body, nutral & Lightning arrestor as per direction of the EIC.
58Providing Coil earthing as per REC specification.
59Triple pole (3 phase), 12 KV, 200 Amp. GOS unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer-In-charge.
60Triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer"s In-charge.
619 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply Nominal Creepage distance 300mm. conforming to ISS:3070/1985 as per the direction of the Engineer"s In-charge.
62Carriage of 11/0.430, 3-Phase 63KVA by mechanical transport from site/ store/ workshop to working site vis-a-vis including loading, unloading and placing on base, as required. C) Beyond 50KM
63Commissioning of AI. wound three Phase ,63KVA, 50 Hz AC, out doortype11/0.433KV,distributiontransformercompletewith necessary accessories and Transformer oil conforming to relevant ISS and required connection by ACSR from 11 KV line to Transformer via G.O.S & D.O.F fixing with of 2 ( two ) Nos strain Screw and nuts & bolts as reqd. as per the direction of Engineer-in-charge and approved drawing.
64LT Shackle Insulators (4X4.5)? with straps & bolts.
65Providing of three phase service connection laying of PVC cable from nearby electrical Pole to the premises up to 35 Meter in length supported by GI-wire, Reel insulator i/c fitting, fixing of Energy Meter (Department supply which shall be collected from respective Electrical Division) as required as per the direction of the Engineer In-charge.
Disclaimer :