Military Engineer Services-MES has published Tender For Repair/Maintenance Of Summer Appliances And Other Misc Works Under Ge ( M ) Af Jalahalli.. Submission Date for this Tender is 02-01-2024. Air Conditioner Tenders in jalahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

40876154
Corrigendum : Tender For Repair/Maintenance Of Summer Appliances And Other Misc Works Under Ge ( M ) Af Jalahalli.
Open Tender
Indian
Karnataka
jalahalli
02-01-2024

Tender Details

Tender For Repair/Maintenance Of Summer Appliances And Other Misc Works Under Ge ( M ) Af Jalahalli.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-2023 CORRIGENDUM BOQ 21-12-2023
2 21-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-12-2023
3 28-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 83100.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK: REPAIR/ MAINT OF SUMMER APPLIANCES AND OTHER MISC WORKS UNDER GE (M) AF JALAHALLI
Sl. No. Item Description
1Disconnecting electric connection from defective blower/ fanmotor and taking out from unit capacity 8.3 TR of existing make and transporting to workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burntwinding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enamelled copper winding wire as per manufacturer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
2Carrying out pressure leak test of 8.3 ton ductile split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :- Supply & charging of refrigerant gas R-22/R-407C will be measured and paid for separately
3Supply and fix Air filter set suitable for 8.3 ton ductable split type AC complete including taking down existing one all as specified and as directed.
4Supply and fix PCB (circuit plate) of in-door unit of 8.3 TR ductable split AC complete including taking down existing one all as specified and as directed.
5Taking out ofdefective wiring of indoor/ outdoor unit ofPCB, visual eye damp plates,fixing the new wiring in place of damaged items of capacity of AC 8.3 TR including matching the existing system all as specified and as directed.
6Supply and fix Thermal relay 20A, 415 Volt, single phase suitable forductable split type AC of 8.3 TR capacity complete including taking down existing one all as specified and as directed. Make : LG / Tecumseh / Hitech/ Indo Asian/L&T.
7Supply and fix Single phase preventer, 230 volt, 50 HZ, AC supply complete including taking down existing one all as specified and as directed. Make : L&T / Seimens / BCH
8Supply and fix PCB (circuit plate) of in-door unit of 4.0 TR ductable split AC complete including taking down existing one all as specified and as directed.
9Removing the window/ split type AC up to 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning all as specified and as directed by Engineer-in-Charge. Note :- The rate of following deemed to be included in quoted rate :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary d)The unit rate quoted by the tenderer inclusive for Removing, servicing,installation, commissioning and testing of all equipment’s,tools and plants, and back in on final position complete (e) The work shall be done by a specialized team of Engineer/Technicians of OEM. (f) Spares will be measured and paid separately. (g) Refrigerant gas will be measured & paid separately.
10Supply and fix polyurethane form insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C any type and at any locationincluding taking down existing one
11Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one all as specified and directed.
12Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, all as specified and directed. Make of fan motor: AUE/ GEC/Himsun.
13Supply and fix Suction valve suitable for 1.5 Ton/2 Ton of split type AC of existing make
14Supply and fixingHermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed Make :- Voltas, LG, Blue star, Hitachi, Kirloskar, Tecumseh Note:- (a)Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
15Supply and fix discharge valve suitable for 1.5 Ton/2 Ton of split type AC including taking down existing one.
16Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one all as specified and directed. Make : As per existing AC at the site.
17Supply and fixingCondenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 2.0 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one all as specified and directed.
18Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TRincluding taking down existing one all as specified and directed.
19Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton splitAC including taking down existing unserviceable one at any location all as specified and directed.
20Supply and fix MS wall bracketsuitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed.
21Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity,including taking down existing one all as specifieddirected. Make of fan motor: AUE/GEC/Himsun.
22Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one all as specified and directed.
23Supply and fixingCopper tube, 9 mm bore (in replacement) superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof including taking down existing one all as specified and directed.
24Supply and fixingHermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit ofsplit type ACof capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed Make :- Voltas, LG, Blue star, Hitachi, Kirloskar, Tecumseh Note:- (a)Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
25Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed.
26Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type ACupto 1.5 TRand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one all as specified and directed.
27Supply and fixing flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity.
28Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Tonincluding taking down existing one all as specified and directed.
29Material and labourfor Refrigerant gas, (R 407C) suitable for cooling equipment"s supplied and filled all as specified and directed.
30Supply and fix dummy nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC
31Supply and fix dummynut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC
32Supply and fix dummy nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC
33Supply and fix dummy nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC
34Supply and fix PVCinsulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size (in replacement) all as specified and directed.
35Supply and fix old UNSV indoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type all as specified and directed by Engineer-in-charge
36Material and labourfor shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed by Engineer-in-Charge. Note :- The rate for following works deemed to be included in quoted rate :- (a)Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j)Fixing of copper tubing of qty of required size.
37Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one all as specified and as directed.
38Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls.Make : Havells/ Indo asian/ Legrand
39Supply and fix flair nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC
40Supply and fix flair nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC
41Supply and fix flair nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC
42Supply and fix flair nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC
43Supply and fix flair nut of dia 1/16" suitable for 1.5 Ton/2 Ton of split type AC
44Supply and fixingCopper tube (in replacement) 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof all as specified and directed
45Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC all as specified and as directed.
46Removing old unserviceablesplit type air conditioner outdoor unit and deposited in store yard for safe custody and Supply and fixoutdoor unit ofthesplit type air conditioner 1.5/2 TR capacity, complete with all accessories such as hermetically sealedcompressor andcondenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etccomplete all as specified and directed.Make: Carrier/LG/Blue star/Voltas/ Hitachi
47Repair and maintenance of inverter type splitAC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower. (c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary. (d)The work shall be done by a specialized team of Engineer/Technicians of OEM. (e)Nearly 50 number of inverter type split AC are installed at the distant height. To carryout servicing of these AC"s special T&P (Boomer vehicles) of height 24 meter will be required. The cost of arrangement of special T&P will be inclusive in quoted rate.
48Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton and including taking down existing unserviceable one of any capacity and at any location all as specified and directed.
49Inspection, checking adjustment and minor repair of unserviceable window type AC any type any capacity placed at any location includes repair/ replacement of defective parts such as checking of electrical connection, condenser, gas leakage, PCB, condenser fan blade, indoor unit, outdoor unit, compressor, PVC pipe etc., complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
50Supply and fixingPCB board of inverter type split type ACfor 1.5 Ton/2 Ton including taking down existing unserviceable one at any location all as specified and as directed.
51Supply and fix Filter (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing one all as specified and directed.
52Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs capacity up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning all as specified and as directed. Note: Toping up of gas will be measured and paid separately
53Supply and fix condenser fan blade suitable for 1.5 Ton split/ window AC including taking down existing unserviceable one and all as specified and directed.
54Supply and fixing Thermostat (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one all as specified anddirected.
55Supply and fixing Front grill (in replacement) suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one all as specified and directed.
56Supply and fixing Blower motor (in replacement) suitable for window type Air Conditioner of any make up to 1.5/ 2 TR capacity including taking down existing unserviceable one all as specified anddirected. Make of fan motor: AUE/ GEC/Himsun.
57Supply and fixing Over load relay (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/ 2 TR capacity, including taking down existing one all as specified and directed.
58Supply and fixingHermetic sealed/Rotory new compressor for window type ACof capacity 1.5 Ton (in replacement) including disconnecting the electrical and refrigerant connection of defective sealed unit ofwindow type ACof capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed Make :- Voltas, LG, Samsung, Blue star, Hitachi Note:- (a)Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
59Supply and fixingCondenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of window type ACup to and including 1.5/ 2 Tonand replacing the condenser coil unit connectingthe same unit withrefrigerant connections complete including taking down existing one all as specified and directed.
60Supply and fix overload protector for window/ split AC 1.5/2 Ton TR capacity including taking down existing unserviceable one all as specified and directed.
61Supply and fixing in replacement Selector switch, suitable for window type Air Conditioner of any make up to 1.5 TR capacity, including taking down existing one all as specified and directed.
62Taking out 3 phase tower AC complete for repair / servicing and overhauling of capacity 4TR ofmake - LIYOD after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacingthe spares like relay, capacitors, thermostat, fan motor, blades & bloweretc. and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note :-(i) Refrigerant gas will be measured and paid separately.
63Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
64Supply and fixingin replacement condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed.
65Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed.
66Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note: Topping up of gas will be measured and paid separately
67Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,all as specified and directed.
68Supply and fixingEvaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement)all as specified and as directed.
69Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity,all as specified and directed.
70Supply and fixingin replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed.
71Supply and fixinghermetically sealed new compressor (in replacement) for 308 to 350 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres. Make :- As per existing make of Refrigerator Note:- (a)Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
72Supply and fixingEvaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement)all as specified and as directed.
73Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid separately
74Supply and fixingicesuperior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed.
75Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed.
76Supply and fixingPVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one all as specified and as directed.
77Supply and fixinghermetically sealed new compressor (in replacement) for 260 to 308 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres. Make :- As per existing make of Refrigerator Note:- (a)Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
78Material and labourfor pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid separately
79Supply and fixingin replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed.
80Supply and fixingChiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,all as specified and directed.
81Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.
82Supply and fixinghermetically sealed new compressor (in replacement) for 165to 260 Ltrcapacity of refrigeratorincluding filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres. Make :- As per existing make of Refrigerator Note:- (a)Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
83Supply and fixingRelay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, all as specified and directed.
84Supply and fixingEvaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement)all as specified and as directed.
85Material and labour for preparing the old painted surface of refrigeratorof capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colourall as specified and directed.
86Supply and fixingVegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity,all as specified and directed.
87Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified and as directed.
88Supply and fixingThermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed.
89Supply and fixingin replacement Gasket, suitable for door of Refrigerator of any make, 165 to 260 litres capacity, fixed in repairs all as specified and directed.
90Supply and fixingMulti capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL/Asian
91Servicing theVoltage Stabilizer 0.5 KVA/2KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed.
92Supply and fixingFilter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.
93Servicing theVoltage Stabilizer 4 KVA to 5 KVA single phaseafter replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assembleback & fixing in its original position including testing for proper functioningcomplete all as specified and as directed.
94Supply and fixingTimer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed as per Make of Refrigerator
95Supply and fixingOver load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..
96Supply and fixingCopper capillary tubesuitable forrefrigeratorincluding taking down existing unserviceable one, any description complete all as specified and directed.
97Supply and fixingStarting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed Make : SRIRAM/GODREJ/RANUTROL
98Supply and fixingMulti capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL/Asian
99Supply and fixingMulti capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL/Asian
100Material and labourfor pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 405 litres including vacuuming and charging the refrigerant Refrigerant gas R-134 a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed.Note:Topping up of gas will be measured and paid separately
101Supply and fixingCopper capillary tube of Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
102Supply and fixingCondenser fan motor of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
103Supply and fixingThermostat for Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
104Supply and fixinghermetic sealed new compressor (in replacement) 1/6 HP suitable for deep freezerof capacity 405 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 405 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Note:-(a)Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
105Supply and fixingStarting relay of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
106Supply and fixingOver load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
107Supply and fixingFilter for Deep freezerincluding taking down existing unserviceable one complete all as specified and as directed
108Material and labourfor Refrigerant gas, (R 22) Freon suitable for cooling equipment"s supplied and filled all as specified and directed.
109Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
110Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas will be measured and paid separately
111Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 150/180 litres capacity, all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
112Supply and fixingDoor gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, all as specified and directed.
113Supply and fix Stainless steel tray (in replacement) suitable for water cooler of150 Litres capacity all as specified and directed.
114Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
115Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
116Material and labourfor preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
117Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas will be measured and paid separately
118Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water coolerof any make of 60/120 litres capacity, including taking down existing one all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
119Supply and fixingSelf closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc. complete all as specified and directed.
120Supply and fixingball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed.
121Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed
122Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
123Supply and fixingPVC drain out pipe 30mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed
124Supply and charging of refrigerant gas R-134a to water cooler,refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed
125Material and labourfor pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas will be measured and paid separately
126Material and labourfor repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
127Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water coolerincluding two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
128Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed.
129Supply and fixingEvaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
130Supply and fixinghermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacityincluding disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
131Supply and fixingElectric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water coolerof any make of 40/80 litres capacity, all as specified and directed. Make of Fan motor: AUE/ GEC/HIMSUN
132Supply and fixingCondensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
133Supply and fixingCarbon (filter) 12” size incl taking down old unsv all as specified and directed
134Supply and fixingMulti capacitors 45 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL/Asian
135Supply and fixingMulti capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed. Make :KELTRON/SRIRAM/EPCOS/BHEL/Asian
136Material and labourfor preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
137Supply and fix in replacement of filter for water cooler of any size any make all as specified and as directed
138Material and labourfor Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance along with blower assembly filter and other components including checking electrical connectionsall as specified and as directed.
139Material and labourfor blower motor assembly of Air curtain unitof any type capacity and length, single phase AC, 230 Volts as including electrical connectionsall as specified and as directed.
140Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refix the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f)Checking functioning of heating elementand correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix.
141Note : The following deemed to be inclusive in quoted rate :-
142The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced, before commencement of work.
143In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
144In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
145The entire job will be carried out in entire area of Air Force stn Jalahalli
146All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
147Supply and fixingOuter body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paints taking down existing one complete all as specified and as directed.
148Supply and fixingHeating element, tikona type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
149Supply and fixingPVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe taking down existing one complete all as specified and as directed.
150Supply and fixingOuter body of MS sheet not less than 20 gauge suitable for50 ltr geyser with white synthetic enamelled paint complete all as specified and as directed.
151Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers
152Supply and fixingfor provision brazing of inner copper tank Geysers using quality of copper electrode blow lamp welding process brazing length n.exc 10 cm all as specified and directed at site the Engr-in-Charge.
153Supply and fixingin replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed.
154Material and labourin replacement PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed.
155Supply and fixingHeating element, thread type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitabletaking down existing one complete all as specified and as directed.
156Supply and fixing Indicator lamp for geyser 25/50 ltr capacity ofcolour green & red complete all as specified and as directed.
157Supply and fixingGlass wool for insulator of Geysers any capacity and any make taking down existing one complete all as directed by the Engr-in-Charge.
158Supply and fixingin replacement thermostat switch range of 30-80 degree suitablefor geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed.
159Supply and fixingin replacement heating element, cup (square) type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitablecomplete all as specified and as directed.
160Supply and fixingCopper inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample taking down existing one complete all as specified and as directed.
161Material and labour forCutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc taking down existing one complete all as specified and directed.
162Supply and fixingHeating element, tikona type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitablecomplete all as specified and as directed.
163Supply and fixingin replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed.
164Heating element, thread type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitabletaking down existing one complete all as specified and as directed.
165Supply and fixingin replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
166Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixingin repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
167All as per item No. 166here-in-above but 50 Ltr capacity.
168Material and labourfor painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
169Supply and installwater heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 barpowder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode,efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE5 Star Rated with complete fittings/partsand accessories for fixing on wall/surfaceall as per site required andspecified anddirected by Engineer-in-Charge.Make:- Bajaj / Recold / Havells
170Supply and fixing Copper inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample taking down existing one complete all as specified and as directed.
171Material and labourfor painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
172Supply and fixingin replacement 50 Ltr capacity in any make indoorassembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
173Supply and fixingin replacement 25 Ltr capacity in any make indoorassembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
174Dismantling carefully solar storage water heating system of 100/200/300 Ltr capacity anny type for following works withtestingand refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts,descaling, washing of inner tankwith chemical solution and cleaning ofouter cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells (f)Necessary T&P such as ladder, helper shall be contractor responsibility.
175Note : The following deemed to be inclusive in quoted rate :-
176The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced, before commencement of work.
177In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @ Rs. 500/- per day shall be recovered.
178In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 100/- per job shall be recovered.
179The entire job will be carried out in entire area of Air Force stn Jalahalli
180Necessary T&P such as ladder, helper shall be contractor responsibility.
181All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
182Gasket setfor solar water heater panel suitable for 100Ltr capacity
183Supply and fixingin replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed.
184Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank should be 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magnetic grade, insulation is PUF 50mm including provn for suitable solar tubes complete all as specified and directed. Note :- Solar tubes will be measured and paid separately
185Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 100 Ltr capacity
186Supply only solar cells to replace the damaged cells in thesolar panel for solar water heater 200 Ltr capacity
187Supply and fixingin replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed.
188Supply and replace solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete.
189Supply and replacement of solar tube as per existing type.
190Supply and fix in replacementrotational moulded 300 litres capacity double layered HDPE water storage tanks cylindrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified in SSR Part I
191Supply and fixing Stop valves, 15 mm Bore of pipe in mm fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
192Material and labourforStaging / steel frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed by Engr in charge.
193Material and labourfor taking down of ceiling fan of size 1200/1400mmfor safety checking by replacingdefective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc. shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However,parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement aredeemed to be inclusive in quoted rate all as directed.
194Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 193 (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
195(b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
196(c)Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
197(d)The entire job will be carried out inAir Force stn Jalahalli
198(e)Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor"s responsibility.
199(f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
200(g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
201(j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
202(k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
203Supply only rotor of ceiling fan of any size
204Supply only fan canopies for ceiling fan size of 1200mm/1400mm
205Supply onlygun metalbush of suitable size for ceiling fan 1200mm /1400 mm sweep
206Supply onlyfan bearing suitable forceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
207Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
208Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm
209Supply only "U" clamp for hanging ceiling fan with all nuts, bolts and washers.
210Supply onlyouter body of ceiling fan of any size
211Supply only safety pins 40mm to 50mm longwith nuts and bolt with washers for ceiling fan of size 1200/1400mm
212Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
213Supply onlyblades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed.Note- Old us blade will be deposited to MES store yard.
214Supply onlyblades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specifiedand directed .Note- Old us blade will be deposited to MES store yard.
215Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
216Supply onlydown rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
217Supply and fixing in replacement of unserviceableCeiling fan 1200mm sweep, energy efficient ISI mark withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient. Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard.
218Supply and fixing in replacement of unserviceable Ceiling fan 1400mm sweep, energy efficient ISI mark with star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient. Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard.
219Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule. (ii) taking down of fan, and re hanging measured under item No.separately.
220Description all as perSl item No 219 here in above but ceiling fan of 1400 mm sweep
221(a) Taking down ofexhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional andmaking connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) aredeemed to be inclusive in quoted rate all as specified and as directed. (Note:- Rewinding, and materials to be replaced are measured separately.)
222(b)The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
223(c)Defecting unserviceable part like fan bush,bearing etc. will be paid under respective item here-in-after as supply only through proper documentation.
224(d)The entire job will be carried out inAir Force stn Jalahalli
225(e) Necessary T&P such as ladder, helper shall be contractor responsibility.
226(f)All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
227(g)Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
228(j)In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
229(k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
230Supply only fan bush of suitable size for exhaust fan of the any sweep
231Supply only 4 mfd capacity ceiling /exhaust fan condensers. Make:- Asian/ Tyton/ CG/ Usha
232Supply only metal louvers of suitable size for exhaust fan of the 450mmsweep
233Supply only fan bearing of suitable size for exhaust fan of 450mmsweepincluding greasing.
234Supply only 3.15 mfd capacity exhaust fan condensers. Make:- Asian/ Tyton/ CG/ Usha
235Supply only metal louvers of suitable size for exhaust fan of the 300mmsweep
236Supply only fan bearing of suitable size for exhaust fan of 300mmsweepincluding greasing.
237Supply only 2.5 mfd capacity ceiling /exhaust fan condensers. Make:- Asian/ Tyton/ CG/ Usha
238Supply only metal louvers of suitable size for exhaust fan of the 250mmsweep
239Supply only fan bearing of suitable size for exhaust fan of 250mmsweepincluding greasing.
240Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, heavy duty,1400 RPM, corrosion less mild steel body of motor, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect reshape of stone masonry, suitable hold fast with necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make- havells /bajaj/ Almonard. Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
241Supply and fixingExhaust fan250 mm sweep 230/ 240 volt AC single phase 410 W, 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:-Old Unserviceable Exhaust fan shall be deposited to MES store yard.
242Material and labour for winding of Exhaust fan 450mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i)Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
243Description all as perSl item No 242 here in above but300 mm sweep
244Description all as perSl item No 242 here in above but250 mm sweep
245Taking down of wall mounted fanany size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling .(Note:- Repair, rewinding, over hauling and materials to be replaced are measured separately.)
246Supply only fan bearing of suitable size for wall mounted fan of 300 mmsweep make-: SKF/TATA/NBC
247Description all as perSl item No 246 here in above but 400 mmsweep.
248Supply only fan bush of suitable size for wall mounted fan of the any sweep
249Material and labour for winding of wall mounted fan300mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
250Description all as perSl item No 249 here in above but 400 mm sweep
251Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid separately) and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
252Material and labour in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through surface PVC conduit/ existing concealedPVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets,blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separately).
253One light point/fan/bell point controlled by one switch
254All as per item No. 253 here in before but for one 3 pin socket out 5 ampon the same board
255All as per item No. 253 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
256All as per Sl No253 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
257Material and labourin repairs for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit/ existing concealed conduitwith accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to wallscovered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistrandedcable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets,blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
258One light point/fan/bell point controlled by one switch
259All as per item No. 258 here in before but for One 3 pin socket out 5 ampon the same board
260All as per item No. 258 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
261All as per Sl No 258 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
262Supply and Fix switch piano flush type 5 Amps240 volts single pole one way. Make : Anchor, Havells, L&T
263Supply and Fix switch piano flush type 15 Amps240 volts single pole one way. Make : Anchor, Havells, L&T
264Supply and Fix shuttered socket outlet 3 pin 5 amps, flush type Make : Anchor, Havells, L&T
265Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps Make : Anchor, Havells, L&T
266Supply and Fixmodular switch1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
267Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
268Supply and Fixmodular switch1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
269Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
270Supply and fixingin replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Indoasian/ L&T/ Havells
271Excavation in trenches insoft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cablesfor foundation and laying of cable/erecting poles up to proper level complete all as specified and directed by Engr-in-charge.
272Returning and filling in soil including spreading leveling watering and well ramming in layers not exceeding 25cm all as specified.
273Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
274Material and labourfor Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurement only punned thickness only will be considered for payment.
275Material and labour for well burnt as class ‘B’ bricks as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed by Engr-in-charge.
276Material and labour for cutting of bituminious road/ hard standing/PCC path/wall up to a size not exceeding 20cm widthand not exceeding 60cm in depth for laying ofprotection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate up to existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface complete all as specified and as directed.
277Supply and fixingin replacement of GI tubing light grade of size 40 mm dia fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed.
278Supply, Laying and testing XLPE UG cable 25sqmmcross sectional area and 3.5 core PVC insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches including taking up defective unserviceable cableall as specified and directed.
279Supply, Laying and testing XLPE UG cable 35sqmmcross sectional area and 3.5 core PVC insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches including taking up defective unserviceable cableall as specified and directed.
280Material and labourEarthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
281(a)All Joints should be joined by Exothermic Welding or Brazing. (b)After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c)Earth resistance tester shall be provided by the contractor. It should be calibrated from authorised company/ lab. (d)After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
282Material and labourin repairs Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail