Construction Of Solarpump Drinking Water Installation Of Drinking Water Reserver With Pump Solar System Jhingapurni Ap School Sansad No 11 Within Barokodali I G P Under Tufanganjii Panchayat Samity
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete(a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). (a) With earth obtained from excavation of foundation |
| 3 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 4 | Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. (a) 1:3:6 proportion |
| 5 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(ii ) River Bazree(I) GROUND FLOOR |
| 6 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. (a) For works in foundation,basement and upto roof of ground floor/upto 4 m. (i) Tor steel / Mild steel I. (TATA/SAIL/RINL )(I) GROUUND FLOOR |
| 7 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works lupte roof of ground floor).(f) 25 mm to 30 mm shuttering without staging in foundation |
| 8 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. |
| 9 | Labour for boring tube well of required dia. by water jet system through any type of soll strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other Incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.50 mm dia |
| 10 | 100 mm dia |
| 11 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD 1785 and threaded to match with G2 Pines as per 15: 1239 (Part-1). (A) PVC Pipes 50 mm dia |
| 12 | 100 mm dia |
| 13 | Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications.50 mm dia |
| 14 | Supplying, fitting and fixing steel cutter plece upto 450 mm long with sockets. |
| 15 | Supply of long screw (150 mm long) of TATA make with sockets (TATA make) and jamnut. |
| 16 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) Multilayera) 1000 litre capacity |
| 17 | Labour for hoisting plastic water storage tank. (i)Upto 1500 litre capacity. (a) Upto 1st story from G.L |
| 18 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 19 | Supplying, fitting and fixing heavy type bell mouth reducing socket 50 mm X 100 mm |
| 20 | Supplying fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm50mm |
| 21 | Supplying, fitting and fixing plug of approved make conforming to I.S Specifications 71 mm |
| 22 | Supplying ting and fixing 300 mm M.S housing clamp of approved quality. |
| 23 | Ms structural works in columns, beams etc. with simple rolled structural members (eg. joists, angle, channel sections conforming to 15: 226, 15: BOR & SP (6)-1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineerincharge complete including cutting to requisite shape and length fabrication with necessary bolting, metal arc welding conforming to 15:816-1969 & 15: 1995 using electrodes of approved make and brand conforming to 15:814-2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required iulie work including a bradente chages such as electricity charges, labour Insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per 15 specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members: weighing not less than 22.5 Kg./m. or 15 % of weight for finished structal members weighing less than 22.5 Kg./m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc and no seperate payment being made for these items, as per direction of Engineer in Charge. The taies are considered for a height of erection 8m./2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m, or part thereof. 1) For structural members of specified sections weighing less than 22.5 Kg./m |
| 24 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to 15-15778: 2007, with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, feting, fixing etc. complete in all respect including cost of all necessary fittings as required jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.25 mm dia |
| 25 | Supplying, fitting and fixing alloy Iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. 15 mm |
| 26 | Priming one coat on steel or other metal surface with synthetic all bound primer of approved quality including smoothening surfaces by sand papering etc. On steel or other metal surface |
| 27 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: With super glass (hi-gloss)- Two Coatsexcept white in shade |
| 28 | Digging earth in any soil including mixed soil but excluding moorum, laterite sand stone or any other hard stone including spreading or stacking the spoils within a lead of 75 metres as directed bailing out water upto 1 metre depth, shoring etc., when and if required and back filling with fine sand (includingcost of sand) on completion of steining works.A) R.C.C. Ring Well i) 1.2 metre diameter of digging for 0.9 metre internal diameter of well ring. a) Upto 3 metre below G.L. |
| 29 | R.C.C. well ring made with cement concrete 1:1.5:3 with stone chips and 0.80% reinforcement (including the cost of shuttering and reinforcement) cast at site fitted and fixed in position afterproper curing true to plumb in the well including jointing withcement mortar 1:2 complete as per direction.a) 65 mm thick and 0.9 metre internal dia.cement for joint filling-4 kg/meter |
| 30 | Supplying, fixing, commissionong andtesting Solar photo Voltaie Module 250 WP 40V on existing Iron frame structure each 156 mm Monocrystalline/Multicrystalline Silicon Solar cells laminated between sheet of Ethyline Vinyl Acilate (EVA) and High transmissivity 3 mm tempered glass. Confirming to IEC 61215(Revised) specification or equivalent National or International Standards. The power output of the module under STC should be minimum of 300W. The operating voltage corresponding to the power output mentioned above should be at least 56.0 Volts. The open circuit voltage of the PV modules under STC should be at least 57.0 Volts.The terminal box IP 65 Protection level on the module should have a provision for opening for replacing the module.(Waaree) |
| 31 | Supplying, Fitting Fixing & Installation of Iran Removing Filter Plant Capacity 1500LPH IR Media Filter Working Downilow Max Flow Rate-3m3/hrWorking Pressure-1-3 kg/cm2 Size-14\"X65 Make Pentair (BIS Standards & Including 1 Year Warranty) |
| 32 | Supply and fixing round 2-core 4 sq-mm PVC multicore FR wire for aray connecting. |
| 33 | Supply and fixing MC4 connector for panel loop. |
| 34 | Earthing with 50 mm (2\") dia GL pipe 3.64 mm thick a3 mts. Long and 1x4 SWG G.I. Wire (4 mts. Long) 13mm dia. X 80 mm long G. pipe protection [1 mtr, long) to be filed with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 m. Below the ground level & restoring the surface duly rammed. for soft soil |
| 35 | Connecting the all equipment to earth busbar Including GI (Hot Dip) wire of size as below on wall floor as required and making connecion to equipment with bolts, nuts, washers cable lugs as required and mending good damages No. 4 SWG. |
| 36 | Providing and fixing conductor made of 25 mm dia 300 mm long copper tube having single prong at top with 85 mm dia 3 mm thick copper base plate Including holes etc. complete as required. |
| 37 | Supply, installation testing &lowering of 1.5 HP oil filled Solar submersible pump motor set complete having Suitable discharge as per yield test of well. Submersible cable of 30 mtr 3 core 25 sqm cable with MOC bar chart and necessary control panel and starter asper manufacturer specification.(Prakash Gold Proxys Solar/ Shreejee/Waaree) |
| 38 | GST 18% |
| 39 | Labour Cess |
AI Tender Summary
Tender Timeline
Nov 30, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 11, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender