Tender For Maintenance Work; Special Repairs To Toilet And Other Repair Works In Dge Ad Block Building At D.P.I Campus In Nungambakkam, Chennai-06.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Dec 2023
0 days left
EMD
9500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
nungambakkam → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Maintenance Work; Special Repairs To Toilet And Other Repair Works In Dge Ad Block Building At D.P.I Campus In Nungambakkam, Chennai-06.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling , removing and carefully stacking Doors &windows includung removal of frames,hinges and fastenings etc., complete complying with standard specification and as directed by the departmental officers at site of work. |
| 2 | Dismantling the damaged floor finish and dadooing walls in cement mortar with mosaic tiles / Glazed tiles/cuddapah slab and clearing away with carefully stacking the material useful for reuse for any thickness etc.,complete complying with standard specification and as directed by the Departmental officers. |
| 3 | Clearing surface thoroughly with water and removing any loose plaster, flacks, fungus growth etc., by suitable mechanical means like scrapping or wire brushing and washing with adequate water to get and absolutely cleaned surface to take up further treatment. Then coating the exposed rods of beams and columns with “Nitro Zinc Prime base + Nitro Zinc Prime hardener” at 2.10 lt/10m2 and mixing the mortar with nitro bond SBR 3 liters per bag of cement finishing the columns and beams neatly with the above cement, chemical treatment with fine sand in the ratio of 1:3, 20mm thick including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 4 | Flooring with followingDesignedceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 5 | Dadooing walls withsize 450x300x6mm best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 6 | Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) |
| 7 | Supply and fixing in position of best Indian make colourglazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) |
| 8 | Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mmwithout pedestal with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 9 | Supplying and fixing in positionUrinal Partition Plate of size 160 X 400 X 825 mm of best quality and approved make including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The squatting urinal should be got approved by the Executive Engineer before use on works). |
| 10 | Renewing Refixing in position of CP Two way Bib cock with Health faucet with new one ofHealth faucet 15mm dia of approved quality and make including labour charges for fixing in position etccomplete complying with standard specification and as directed by the departmental officers. |
| 11 | Renewing and refixing in position of SS heavy duty Long body tap of approved quality make to IS Specification(Gross weight shall not be less than 400grams) and quality including cost of shellac, thread etc., complete complying with standard specification and as directed by the departmental officers. |
| 12 | Renewing and refixing in position of CP Angle Cock Tap of approved quality make conforming to IS Specification(Gross weight shall not be less than 400grams) and quality including cost of shellac, thread etc., complete complying with standard specification and as directed by the departmental officers. |
| 13 | Renewing and refixing in position18 inch long HDPE connection hose is approved qualityincluding cost of materials etc., complete and as directed by the departmental officers. |
| 14 | Renewing and refixing in position of32mm dia waste hose is approved quality including cost of materials etc., complete and as directed by the departmental officers. |
| 15 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 16 | 110mm dia PVC pipe |
| 17 | 75mm dia PVC pipe |
| 18 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 19 | 110mm dia PVCbend |
| 20 | 75mm dia PVC bend |
| 21 | 110mm dia PVC Elbow |
| 22 | 75mm dia PVC Elbow |
| 23 | Renewing andlaying and jointingUPVC Pipe(Un-Plasticized Polyvinyl Chloride) UPVC used for commercial applications operate and designed to handle higher water pressure (schedule-80) but excluding cost of such specials and fixing in position dismantling masonry and make the same to original conditionetc complete complying with standard specification and as directed by the departmental officers at site of work. |
| 24 | 32mm dia UPVC Pipe |
| 25 | 25mm dia UPVC Pipe |
| 26 | 20mm dia UPVC Pipe |
| 27 | Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements |
| 28 | 32mm dia Coupler |
| 29 | 25mm dia Coupler |
| 30 | 20mm diaCoupler |
| 31 | 32mm dia Elbow |
| 32 | 25mm dia Elbow |
| 33 | 20mm dia Elbow |
| 34 | 32mm dia Bend |
| 35 | 25mm dia Bend |
| 36 | 20mm dia Bend |
| 37 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 38 | Renewing and refixing Solid PVC door shutter with frameusing 19 gauge 19mm MS Square tubes for styles and outer frames, 15mm MS Square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, lock rail and bottom rail shall by 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter.Solid panel PVC door withframe. |
| 39 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work |
| 40 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 41 | Renewing and fixing Mild Steel Grills for windows and ventilators etc., including the cost of mild steel angles, plates, rods, cost of welding charges and one coat of priming coat etc., complete.(The design should be got approved by the departmental officers.) |
| 42 | Repainting the old iron work two coats of synthetic enamel paint of approved quality and colour and brand including thorough scrapping preparation of surface and finishing neatly etc complete complying with standard specification and as directed by the departmental officers at site of work.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 43 | Collecting the earth debries using tipper mechinary from works sport and dumping the same into low area to a distance of 3 km away from the site etc., complete complying with standard specification and as directed by the Departmental officers. |
| 44 | Total in Figures |
AI Tender Summary
Tender Timeline
Nov 30, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 08, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender