Department Of Lighthouses And Lightships has published Tender For Provision Of Heritage Streetlights And Landscaping Lights For Tourism At Anjengo Lighthouse. Submission Date for this Tender is 14-12-2023. Street Lighting Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Annexure-I: Paver Removal Works for Cable Trenching, Streetlight lighting foundation works & demolishing works – Civil Works |
2 | Paver Removal Works |
3 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (Paver Block Removal from pathways for UG Cable trenching) |
4 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge (Dismantling of PCC/RCC beneath the paver block) |
5 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (Excavation of earth for construction of Cable trench) All kinds of soil |
6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level : (Plain Cement Concrete for base foundation of the trench including labour and materials) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
7 | Laying old cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost).(Re-laying of Paver Block in Cable Trenches after UG Cable laying) |
8 | Streetlight, Landscaping Luminaries Pole errection work |
9 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (Excavation of earth for construction of Streetlight pole foundation) All kinds of soil (for 10 Nos. of Heritage type Streetlight) |
10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level: (Plain Cement Concrete for base foundation of the trench including labour and materials)1:4:8 (1 Cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size (foundation for 10 Nos. of Heritage type Streetlight) |
11 | Brick work with common burnt clay bricks of class designation 7.5 in mud mortar (for 10 Nos. of Heritage type Streetlight) |
12 | 15mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of single or half brick wall. (For 10 Nos. of Heritage type Streetlight) 5 sides each |
13 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer (for 10 Nos. of Heritage type Streetlight) |
14 | Wall painting with Exterior emulsion paint of approved brand and manufacture to give an even shade - Two coats on new work (for 10 Nos. of Heritage type Streetlight) |
15 | Demolishing R.C.C./Brick work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge (Dismantling of PCC/RCC/Brick streetlight foundation and post total 05Nos.) |
16 | Annexure-II: Provision of Streetlights and Landscaping Lights at Anjengo Lighthouse - Electrical Works |
17 | Laying of UG Cable in Cable Trays and Cable markers |
18 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/surface with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
19 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
20 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm |
21 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sands: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
22 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
23 | Provision of Electrical Switch Gear and Earthing |
24 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8-way, Double door |
25 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
26 | Supplying and fixing 5A to 32A rating, 240/415V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6A – 1Nos., 16A – 1No. |
27 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
28 | Electricalfittings |
29 | Supply of Outdoor LED Decorative heritage type Street Lighting Luminaries, 30W LED, with Cast iron pole of 2.4m reputed make and model as required |
30 | Fabrication of Street light and Garden Light Poles and Accessories |
31 | 8mm thick MS Plate of size 450x450mm (approx. 15Kg each) for Base plate of Streetlight Poles including gas cutting charges in required size(10Nos. Of poles) |
32 | Placing MS base plate with necessary holes drilled with required number of GI Nuts and Bolts as the template for positioning of the posts and concreting the base for foundation bolts |
33 | SMC Pole mounted Junction Box with side hinged door, IP55, Sintex make GSJB 2014 |
34 | 30A Bakelite/16A Porcelain Type Kit Kat Fuse Unit/ 6A MCB |
35 | 30A Bakelite Neutral Link |
36 | 30A 6way Closed Bakelite type Terminal Connector for each JB |
37 | Supply of Un-armoured, 3Core x 1.5 sq.mm, All Copper Conductor - Solid / Stranded Non-Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (For each Streetlight 5m x 10Nos.) |
38 | 3"" dia GI B Class Pipe, Tata/Jindal make for UG Cable crossover at pathways [one length pipe = 6m] |
39 | 16/6A, Socket, 3pin Combine, Modular type (2M), with Indicator DP Switch, Modular type (2M), 32A and with 4Module Plate, 4Module PVC Box, Legrand make, Model MyLinc for Lawn Mover. |
40 | Supply of UG Cable, 2Core x 2.5 sq.mm, Armoured, All Copper Conductor - Solid / Stranded Non Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, , Finolex / Havells/ATC make or reputed make as required for Outgoing Mains to circuits of Streetlight (pathway), one circuit of Gate Light & Compound Light and one circuit of 16A socket. |
41 | Labour Charges for wiring and cable terminations all type lighting luminaries and, 16A socket, MCB DB & JB fixing work, 2coat primer & paint for normal streetlights (including materials) etc., |
42 | Miscellaneous items such as cable glands, cutting blades, 2” PVC pipes and bends for cable entry, screws, nylon grip plugs, masonry bits, Cable ties, end caps, etc., |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail