Tender For Provision Of 02 X Borewells In Ph Ii Under Ge Narangi; 1 M & L For Pilot / Trial Bore Of 200 Mm Dia Upto 200 Meter Depth Below Ground Level In Any Kind Of Soil Strata Including Hard Stone / Boulder By Means Of Dth / Rotary Rig Method Complete All As Specified And As Directed By The Engr-In-Charge. [ Note: - In Case The Results Of The Borehole / Strata Are Found Un-Satisfactory & The Tubewell Is Not Likely To Yield The Specified Quantity Of Water, The Site Will Be Abondoned And No Other Items Shall Be Executed ] 2 M & L For Reaming Of Bore Developed At Ser No 1 Above Of Size Not Less Than 400 Mm Dia Suitable For 200Mm Dia Housing Pipe Up To 40 Meter Depth Below Ground Level & For 150 Mm Housing Pipe For Depth From 40 Meter Bgl To 150 Meter Deep Bgl. The Drilling Of Bore Shall Be Done By Combination Rig ( Direct / Reverse Rotary Circulation Method ) By Deploying Suitable Machinery Of Suitable Size & Different Cutters Through Any Kind Of Soil Boulders, Rocks Etc Including All Arrangement For Circulation Of Water Using Bentonite Or Silly Clay ( Quantity / Content Mixed As Per Manufacturer Recommendation Or As Directed By Engr-In-Charge As Per Site Or Soil Conditionincluding Disposal Of Spoil From The Site N. Exc 1 Km And Site Clearance Complete All As Specified & Directed. [ Note:- ( I ) The Cost Of Mobilisation Of Rig Set With Tools And Plant Assembly, Pumps And Fittings Etc, Use And Waste Of All Necessary Appliances And Materials Including Levelling Dismantling After Completion Of Tube Well Assembly Including Testing To Entire Satisfaction Engineer-In-Charge Shall Deem To Be Included In The Above Quoted Rate By The Tenderer. No Extra Claim What So Ever Shall Be Admissible. ( Ii ) The Dth / Rotary Rig Should Be Registered With Central Ground Water Authority. ] 3 All As Per Ser Item No 2 Above But Suitable For 150Mm Dia Housing Pipe From 40 Mtr Below Ground Level To 150 Mtr Deep Below Ground Level. 4 Shifting Of T&P To Site And Back For And Including Electric Logging For Exact Selection Of Strata / Aquifier Level And Precise Delineation Of Granular Zones & Also The Quality Of Ground Water Including Report Interpretation As Per Is:2800 ( Part-Ii ) Complete All As Specified And As Directed. [ Note:- ( I ) Electrical Logging Shall Be Carried Out By Any Approved Govt Approved Agency. ( Ii ) No Payment Of Casing Pipes / Slotted Pipes / Column Pipes Shall Be Made Before Electric Logging Test ] 5 Supply And Packing Pea Gravel River Washed Of Sutible Size I.E. 8 Mm To 4 Mm As Per Is Around The Housing / Assembly & Slotted Pipe Of Bore Well Complete All As Specified And As Directed ( For Works Involving Rotary Rig Boring ) . [ Note: Measurement Of Pea Gravel Shall Be Taken In Measuring Box At Site & The Same Shall Be Recorded In Mb Duly Signed By Engr-In-Charge Before Packing Surrounding The Tube Well Assembly. From The Total Volume 10 % ( Ten Percent ) Of The Volume Shall Be Deducted & Net Volume Thereafter Worked Out For The Purpose Of The Payment. ] 6 Supply, Assembling, Jointing, Welding And Lowering 3.00 Mtr Long, Bail Plug Made By 150 Mm Diameter Erw Pipe And One End Closed By 6 Mm Thick Ms Plate Welded And Fixing In Position ( Including Necessary Cleaning Internal And External And Painting Inside Of Pipes With Two Coats With Black Paint Suitable For Drinking Purpose ) And Fixed At Bottom Of Casing Pipe Plain Ended, Jointed By Suitable Size Socket With Full Welding Complete Surrounding The Pipes In Both Ends To Made Leakproof Complete All As Specified & Directed. 7 Supply, Assembling, Jointing, Welding And Lowering Vertically Erw Ms Casing Pipe 200Mm Dia Of Wall Thickness 8.00 Mm As Per Is-4270 / 3589 And Fixing In Position ( Including Necessary Cleaning Internal And External Surfaces And Painting Inside And Outside Of Pipes With Two Coats Of Anti Corrosive Black Bituminious Paint Suitable For Drinking Purpose In Different Depth As Directed, Screwed, Socketed, Jointing With Heavy Duty Suitable Size Collar ( Stiffeners ) And Necesary Electric Arc Welding Conforming To Is-358 / .1991 Surrounding The Entire Circumference Of Pipe With 04 Nos Stiffeners Of Flat Iron 40Mm X 6Mm Thick, 300Mm Long Both Sides Complete. [ Note : Pipes Shall Be Of Length 06 Mtr Unless Required In Smaller Lengths As Per Borewell Requirement Complete All As Specified & Directed. ] 8 Supply, Assembling, Jointing And Lowering Vertically Erw Ms Casing Pipe 150Mm Dia Of Wall Thickness 8.00 Mm As Per Is-4270 / 3589 And Fixing In Position ( Including Necessary Cleaning Internal And External Surfaces And Painting Inside And Outside Of Pipes With Two Coats Of Anti Corrosive Black Bituminious Paint Suitable For Drinking Purpose In Different Depth As Directed, Screwed, Socketed, Jointing With Heavy Duty Suitable Size Collar ( Stiffeners ) And Necesary Electric Arc Welding Conforming To Is-358 / .1991 Surrounding The Entire Circumference Of Pipe With 04 Nos Stiffeners Of Flat Iron 40Mm X 6Mm Thick, 300Mm Long Both Sides Complete. [ Note : Pipes Shall Be Of Length 06 Mtr Unless Required In Smaller Lengths As Per Borewell Requirement Complete All As Specified & Directed. ] . 9 Supply And Fixing Of Ms Taper Reducing Socket 200X150 Mm Having 10 Mm Wall Thickness Heavy Duty With And Including Socket Threaded As Per Is 2800 ( Part-I ) For Jointing Casing Pipe Of Bore Well Including Necessary Welding Work Complete All As Specified And As Directed. [ Note: - ( I ) Unit Rate Quoted By The Tenderer Shall Be Deemed To Be Inclusive Of Arc Welding Surrounding The Entire Circumference Of Pipe, Machining, Welding Materials And Anti-Corrosive Black Bituminous Paint Suitable For Drinking Purpose Both Internal And External Surface Of Pipe. ] 10 Supply Assembling , Jointing And Lowering 150 Mm Internal ( Low Carbon Galvanised ) Lcg V Wire Cage Type Strainer Pipe Of Approved Make Conforming To Is -8110-2000 Of Suitable Slot Not More Than 1 Mm And Fixing In Position ( Including Necessary Cleaning Internal And External Surfaces ) In Different Depth As Directed And Welded With Ms Pipe And Jointed With Heavy Duty Suitable Size Collar Complete With Butt Welding Surrounding The Entire Circumference Of Pipes Complete All As Specified And As Directed. [ Note:- ( I ) Slot Size Shall Be Selected As Per Cgwb Recommendation As Per Strata Or As Directed By The Engr-In-Charge As Per Guideleines Provided At Annex B To Is-8110: 2000 ( Ii ) Pipes Shall Be Of Length 06 Mtr Unless Required In Smaller Lengths As Per Borewell Requirement. ] 11 M&L For Sanitary Sealing Around The Borewell With Pcc ( 1:2:4 ) Type B1 Of Suitable Size Using 20Mm Graded Aggregate Of Size 1Mtr X 1Mtr X 1Mtr Wth Embedded Gravel Feed Pipe 80 Mm Dia Bore Gi Light Grade Of Size 2 Mtr Long As Per Is: 2800 ( Part-I ) Complete All As Specified And As Directed. 12 M & L For Rcc Columns Two Nos Having Size Of 300 X 300 Mm Below Gl 1.5 Mtr Depth And 4 Mtr Height Above Gl Of M 25 Grade Having Ismb 200 Of Length 2.5 Mtr Placed At The Top Of The Columns For Lowering And Unlowering Of Submersible Pump And Ms Column Pipes Complete All As Specified And Directed. [ Note : Unit Rate Quoted By The Tenderer Shall Be Deemed To Be Inclusive Ofform Work, Tmt Bars, Ismb, Cement, Sand, Aggregate Etc To Complete The Structure All As Specified And Directed. ] 13 Supply & Fixing Centering Guide Made Out Of40 X 6 Mmms Flat Iron Made To Shape As Per Is 2800 Part-I Complete All As Specified And As Directed. [ Note: Centering Guide Shall Be Provided For Proper Alignment Of Pipe As Per Requirement Of Site ( Minimum 02 Nos ) 14 M&L For Development Of Tube Well With Air Compressor As Per Is : 11189 Of Suitable Capacity Till Sand / Mud Free Water Of Potable Quality Is Obtained And To Achieve Minimum Discharging Capacity Of 61000 Lph / Max Yield Complete All As Specified And Directed By Engr-In-Charge. [ Note: - Compressor With Accessories And Fuel Shall Be Arranged By The Contractor And Cost Thereof Deemed To Be Included In The Quoted Rate ] 15 M&L For Development Of Tube Well As Per Is : 11189 By Over Pumping 25 % Using Suitable Size / Type Pump After Completion Of Item Ser No 14 Above, Including Yield Testing For The Tube Well Not Less Than 08 Hrs Continuously By V Notch Method As Per Is : 2800-2 1979 To Determine The Safe Pumping Yield Of Tube Well Complete All As Specified And As Directed By The Engr-In-Charge. [ Note: - ( I ) Yield Test Of Borewell Shall Be Carried Out In The Presence Of Ge. ( Ii ) V Notch & Other Equipment Included Diesel Driven Pump Set Including Fuel / Submersible Cable For Metered Connection Shall Be Arranged By The Contractor And Cost Thereof Deemed To Be Included In The Quoted Rate ] 16 Supply And Fixing Well Capfor 200 Mm Bore Erw 8.00Mm Thick Casing Pipe Made Out Ofms Plate 6 Mm Thick For Covering Tube Wellduly Welded With Locking Arrangement, Including Making Holes For Passing Flat Submersible Cable And Support Chain Complete All As Specified And As Directed. 17 Supply, Install, Test And Commission Submersible Pump Set 7.5 Hp Capacity, 415Volt Ac 50 Hz, With Head Range Of 120 To 312 M, Discharge - 5.4 To 2.0 Cum / Hr Suitable For 100 Mm Bore Dia Column Pipe Complete All As Directed. Make: Ksb Or Equivalent In Kirloskar 18 Supply And Lowering Gi Column Pipe Heavy Duty ( As Per Is: 1239, Part-I ) 50 Mm Dia Bore 3 Mtr In Length Both Side Ms Flanged ( 12Mm Thick ) Duly Welded Including Nuts, Bolts, Washers And Rubber Gasket For Flange Jointing Including Making Suitable Grooves For Passing Wire Or Cablecomplete All As Specified And As Directed 19 S&F Steel Chain Made Out Of6 Mm Dia ( Size 20Mmx38mm ) Or Swr Wire With Pvc Coating For Holding Submersible Pump Set / Column Pipe Including Necessary Holding ( Ms ) Clamp Nuts, Bolts Etc. Complete All As Specified & As Directed. 20 Supplying Laying And Testing Pvc Insulated Submersible Cable 6 Sq Mm 3 Core Flat Lt 1100Volt Grade Heavy Duty Isi Marked With Copper Conductor And Overall Served With An Outer Sheath Of Pvc Along The Column Pipe Or Passing Through Pipes Or Laid Under Floor Of Through Walls Etc Jointing And Testing Complete. 21 Supply And Fixing Mild Steel Well Clamp Suitable For 200 Mm Dia Bore Casing Pipe Made Out Of 200 Mm X 16 Mm Thick Ms Plate Fabricated To Shape, Including Drilling Holes, Nuts, Bolts Washers Etc Complete All As Specified And Directed. [ Note: Minimum 02 Nos Well Clamp Shall Be Provided ] 22 Supply And Fixing Clamp Suitable For 100 Mm Dia Bore Column Pipe With Clamp Ends Overlapping The Casing Pipe By Not Less Than 600 Mm, Clamp Should Be Made Out Of Ms Flat Iron 150 Mm X 16 Mm Size Fabricated To Shape, Including Drilling Holes, Nuts, Bolts Washers Etc Complete All As Directed. [ Note: Minimum 02 Nos Clamp Shall Be Provided ] 23 Supply Only Strata Sample Box With Glass Cover 3Mm Thick Having Internal Dimension 1000Mm X 600Mm X 100Mm Made Out Of 20Mm Thick Worught Ist Class Hard Wood Shisham With Hinges , Hasp And Staple Including Polishing Complete With Samples At Various Depth Every 3 Mtr Interval Met In Boring Including Lithological Log Strata Chart In Duplicate Complete. 24 Supply And Fix Gun Metal Non Return Screwed Both Ends, Isi Marked Suitable For For 50 Mm Bore Gi Pipe All As Directed. 25 M&L For Geophysical Survey Report From Recognized Agency Concluded By Geophysical Holding MasterS Degree In The Stream Of Geophysics To Excatly Pin Point The Location Of Proposed Borewell For Maximum Yeild / Output In Accordance With Cgwb Report Complete All As Specified And Directed. 26 Supply, Laying And Testing 50 Mm Bore Gi Tubing ( Medium Grade ) With New Fittings Laying In Trenches All As Directed And Specified. 27 Supply And Fixing In Repair 50 Mm Bore Gun Metal Gate Valve With Iron Wheel Head, Screwed Both Ends For Iron Pipes Or For Unions As Directed By The Engineer-In-Charge. All As Per Is : 778-84 Marked Cl-1 Pressure Tested 2.4 Mpa . 28 Supply & Laying In Trenches / Fixed To Pole, Walls. Etc Lt, Xlpe Insulated, Armoured, Heavy Duty Electric Power Cable With Aluminum Conductor, 1100 Volts Grade, Cross Sectional Area 25 Sqmm, 4 Core Conforming To Is-7098 ( Part-I ) -1988 And Testing Complete As Specified And Directed. 29 Excavation In Trenches Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth For Cable Trenches And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed By The Engineer-In-Charge. 30 Returning, Filling In Trenches Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm In Soft / Loose Soil Complete All As Specified And As Directed By The Engineer-In-Charge. 31 Removing Excavated Materials To A Distance Not Exceeding 50 Metre And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point All As Specified And As Directed By The Engineer-In-Charge. 32 Material And Labour For Sand Cushioning For Protection Of Underground Cable, Consolidatedand Compacted With Clean Dry Sand All As Specified And As Directed By The Engineer-In-Charge. 33 Material And Labour Well Burnt Old Size Sub Class ‘B’ Bricks, Laid Flat, In Trenches For Cable Protection Complete All As Specified And As Directed By The Engineer-In-Charge. 34 M & L For Earthing Complete With Galvanised Steel Earth Plate Electrode 600 X 600 X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level Connected To Galvanised Earth Lead Strip Of Size 32 X 6 Mm By Mean Of Bolts Nuts, Check Nuts And Washer Of Galvanised Iron Steel Including Necessary Excavation, Earth Work, Pcc Chamber Etc All As Shown In Electrical Plate No.3 Of Si 2009 Part-I And Connected To Earthing Test Point All As Specified Includingci Cover, Funnel With Gi Watering Pipe Of 20Mm Bore Medium Grade & Gi Protection Pipe 40Mm Bore Light Grade Including Testing Etc Complete All As Specified & Directed. ( Length Or Earth Lead Strip & Protection Pipe Shall Be Up To 7.5 Mtr ) . ( For Panel ) 35 Testing Of Raw Water For All Parameters, Chemical And Bacteriological Aspect Such As Ph Value, Dissolved Solids, Hardness As Caco3, Calcium, Magnesium, Chlorides, Sulphates, Nitrate, Alkalinity, Iron, Turbidity Ntu, Miniral Oil, Colour Hazen Units, Taste, Odour, Total Coliform Per 100 Ml ( Microbiological Test ) & E Coil Per 100 Ml ( Microbiological Test ) , Arsenic & Fluoride Test ( All Ss Per Is 10500:2012 ) From Govt Laboratory [ Note:- The Sample Of Raw Water Will Be Forwarded To The Laboratory Directly By The Department Duly Sealed. The Testing & Postal Charge Shall Be Borne By The Contractor & Report Shall Be Submitted To The Department / Ge Directly By The Laboratory. ] 36 Supply, Install, Test And Commission Outdoortype Cubicallt Panel Boardsuitable For 3 Phase, 4 Wire, 415 Volts And Cpri Approved, Factory Fabricated Having Modern Fabrication And Testing Process Which Includes Seven Tanks Pre Treatment Process, Comprising Of Degreasing, Rising, Derusting, Phosphating And Preservation Followed By Anti Corrosive Painting ( After Applying Two Coats Of Metal Primer ) With Siemens Grey Paint.The Panel Shall Be Provided With Suitable Gasket To Make It Dust / Vermin Proof And Degree Of Protection Not Less Than Ip-54 And General Construction Conforming To Is.The Panel Shall Be Made Out Of 3.15 Mm Thick Crca Sheet Duly Compertment Wise For Each Control Gear, Front And Back Opening With Sliding Bolt Type Locking Arrangement. The Panel Board Shall Be Provided With Proper Ventillation, Including Suitable Size Of Cable Alley Aluminium Bus Bar Suitable For Carrying Of Current200 Amps . Connections From Mccb Out Going To Main Bus Bar Shall Be Carried Out With Tpn Aluminium Bus Bars Of Suitable Rating And Connections From Main Bus Bar To Out Going MccbS ( Intake Point ) Will Be Carried Out With Tpn Aluminium Bus Bar As Per Mccb Rating Duly Insulated And Colour Coded Heat Shrinkable Sleeve And Shall Be Rigidly Mounted On Suitable Size Of Bridge Insulator.The Cubical Shall Have Bottom Channel Of Suitable Size Mc100 And Angle Iron 50X50x6mm Thick Legs Of 75 Cm Long ( 45Cm Above Ground And 30 Cm Below Ground ) And Painted With 2 Coats Of Smoke Gray Synthetic Enamel Paint Over A Coat Of Red Oxide Primer.Suitable Bolts To Fix Gi Earth Busbar Of Size 50X6 Mm Shall Be Provided And A Detachable Pre Drilled Gland Plate Of Powder Coated Shall Be Provided At Bottom. All Control Wires Shall Be Copper Conductor, Multistranded Flexible And Shall Be Bunched, Tied, Ferruled For Proper Identification And Crimped Including Cable Connections With Adequate Size Aluminium Lugs Complete All As Directed By The Engineer-In-Charge.The Panel Shall Comprise Of The Following ( A ) Incomming :Mccb 32 Amps, 4 Pole, 25 Ka- 01 Nomake Legrand / Schenider / L&T ( B ) Out Going :Mccb25 Amps, 3 Pole, 25 Ka- 01 No Make Legrand / Schenider L&T ( C ) Mcb Tp 25 Amps, 10 Ka, C Curve - 01 No. Make: Legrand / Schneider / L&T ( D ) Multifunction Meterled C1 With Rs 485, Make: L&T -01 Set ( E ) Ct 50 / 5 - 3 Nos ( F ) Indicator Lamp Led Type ( Ryb ) ( 03 Nos ) Set-01 ( G ) Submersible Star Delta Starter Suitable For 10 Hp Motor With Short Circuit / Phase Protection / Low Water Level Protection - 01 Each [ Note :- 1. Mccbs Are To Be Of Fixed Thermal And Fixed Magnetic Setting Type, Complete All As Directed By Engr-In-Charge.2. Excavation, Earth Work And Pcc Work ( 1:3:6 ) Shall Be Deemed To Be Included In The Quoted Rate. 3.Design And Drawing Of Panel Board Shall Be Got Approved From Ge Before Procurement / Incorporation In The Work. ]

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 87200.0 /-
Tender Value
INR 43.60 Lakhs /-

BOQ Items

Name of Work :PROVN OF 02 X BOREWELLS IN PH-II UNDER GE NARANGI
Sl. No. Item Description
1M & L for Pilot/ Trial bore of 200 mm dia upto 200 meter depth below ground level in any kind of soil strata including hard stone/ boulder by means of DTH/ Rotary rig method complete all as specified and as directed by the Engr-in-Charge. [Note: - In case the results of the borehole/ strata are found un-satisfactory & the tubewell is not likely to yield the specified quantity of water, the site will be abondoned and no other items shall be executed]
2M & L for reaming of bore developed at Ser No 1 above of size not less than 400 mm dia suitable for 200mm dia housing pipe up to 40 Meter depth below ground level & for 150 mm housing pipe for depth from 40 Meter BGL to 150 Meter deep BGL. The drilling of bore shall be done by combination rig (Direct/ Reverse rotary circulation method) by deploying suitable machinery of suitable size & different cutters through any kind of soil boulders,rocks etc including all arrangement for circulation of water using bentonite or silly clay(Quantity/Content mixed as per manufacturer recommendation or as directed by Engr-in-Charge as per site or soil conditionincluding disposal of spoil from the site n. exc 1 KM and site clearance complete all as specified & directed. [Note:- (i) The cost of mobilisation of rig set with tools and plant assembly, pumps and fittings etc, use and waste of all necessary appliances and materials including levelling dismantling after completion of tube well assembly including testing to entire satisfaction Engineer-in-Charge shall deem to be included in the above quoted rate by the tenderer. No extra claim what so ever shall be admissible. (ii) The DTH/ Rotary rig should be registered with Central Ground Water Authority.]
3All as per Ser Item No 2 above but suitable for 150mm dia housing pipe from 40 Mtr below ground level to 150 Mtr deep below ground level.
4Shifting of T&P to site and back for and including Electric logging for exact selection of strata/ aquifier level and precise delineation of granular zones & also the quality of ground water including report interpretation as per IS:2800 (Part-II) complete all as specified and as directed. [Note:- (i) Electrical logging shall be carried out by any approved Govt approved Agency. (ii) No payment of casing pipes/ slotted pipes/ column pipes shall be made before electric logging test]
5Supply and packing pea gravel river washed of sutible size i.e. 8 mm to 4 mm as per IS around the housing/assembly & slotted pipe of bore well complete all as specified and as directed (for works involving rotary rig boring). [Note: Measurement of pea gravel shall be taken in measuring box at site & the same shall be recorded in MB duly signed by Engr-In-Charge before packing surrounding the tube well assembly. From the total volume 10 % (Ten Percent) of the volume shall be deducted & net volume thereafter worked out for the purpose of the payment.]
6Supply, assembling, jointing, welding and lowering 3.00 mtr long, bail plug made by 150 mm diameter ERW pipe and one end closed by 6 mm thick MS plate welded and fixing in position (including necessary cleaning internal and external and painting inside of pipes with two coats with black paint suitable for drinking purpose) and fixed at bottom of casing pipe plain ended, jointed by suitable size socket with full welding complete surrounding the pipes in both ends to made leakproof complete all as specified & directed.
7Supply, assembling, jointing, welding and lowering vertically ERW MS casing pipe 200mm dia of wall thickness 8.00 mm as per IS-4270/3589 and fixing in position (including necessary cleaning internal and external surfaces and painting inside and outside of pipes with two coats of anti corrosive black bituminious paint suitable for drinking purpose in different depth as directed, screwed, socketed, jointing with heavy duty suitable size collar (stiffeners) and necesary electric arc welding conforming to IS-358/.1991 surrounding the entire circumference of pipe with 04 Nos stiffeners of flat iron 40mm x 6mm thick, 300mm long both sides complete.[Note : Pipes shall be of length 06 mtr unless required in smaller lengths as per borewell requirement complete all as specified & directed.]
8Supply, assembling, jointing and lowering vertically ERW MS casing pipe 150mm dia of wall thickness 8.00 mm as per IS-4270/3589 and fixing in position (including necessary cleaning internal and external surfaces and painting inside and outside of pipes with two coats of anti corrosive black bituminious paint suitable for drinking purpose in different depth as directed, screwed, socketed, jointing with heavy duty suitable size collar (stiffeners) and necesary electric arc welding conforming to IS-358/.1991 surrounding the entire circumference of pipe with 04 Nos stiffeners of flat iron 40mm x 6mm thick, 300mm long both sides complete.[Note : Pipes shall be of length 06 mtr unless required in smaller lengths as per borewell requirement complete all as specified & directed.] .
9Supply and fixing of MS Taper reducing socket 200x150 mm having 10 mm wall thickness heavy duty with and including socket threaded as per IS 2800(Part-I) for jointing casing pipe of bore well including necessary welding work complete all as specified and as directed. [Note: -(i) Unit rate quoted by the tenderer shall be deemed to be inclusive of Arc welding surrounding the entire circumference of pipe, machining, welding materials and anti-corrosive black bituminous paint suitable for drinking purpose both internal and external surface of pipe.]
10Supply assembling , jointing and lowering 150 mm internal (low carbon galvanised) LCG "V" wire cage type strainer pipe of approved make conforming to IS -8110-2000 of suitable slot not more than 1 mm and fixing in position (including necessary cleaning internal and external surfaces)in different depth as directed and welded with MS pipe and jointed with heavy duty suitable size collar complete with butt welding surrounding the entire circumference of pipes complete all as specified and as directed. [Note:-(i) Slot size shall be selected as per CGWB recommendation as per strata or as directed by the Engr-in-Charge as per guideleines provided at annex "B" to IS-8110: 2000 (ii) Pipes shall be of length 06 Mtr unless required in smaller lengths as per borewell requirement.]
11M&L for sanitary sealing around the borewell with PCC (1:2:4) type B1 of suitable size using 20mm graded aggregate of size 1Mtr x 1Mtr x 1Mtr wth embedded gravel feed pipe 80 mm dia bore GI light grade of size 2 Mtr long as per IS: 2800(Part-I) complete all as specified and as directed.
12M & L for RCC columns two nos having size of 300 x 300 mm below GL 1.5 Mtr depth and 4 Mtr height above GL of M 25 grade having ISMB 200 of length 2.5 Mtr placed at the top of the columns for lowering and unlowering of submersible pump and MS column pipes complete all as specified and directed.[Note : unit rate quoted by the tenderer shall be deemed to be inclusive ofform work, TMT bars, ISMB, cement, sand, aggregate etc to complete the structure all as specified and directed.]
13Supply & fixing centering guide made out of40 x 6 mmMS Flat Iron made to shape as per IS 2800 Part-I complete all as specified and as directed.[Note: Centering guide shall be provided for proper alignment of pipe as per requirement of site (minimum 02 Nos)
14M&L for development of tube well with air compressor as per IS : 11189 of suitable capacity till sand/mud free water of potable quality is obtained and to achieve minimum discharging capacity of 61000 LPH/ Max yield complete all as specified and directed by Engr-in-Charge. [Note: - Compressor with accessories and fuel shall be arranged by the contractor and cost thereof deemed to be included in the quoted rate]
15M&L for development of tube well as per IS : 11189 by over pumping 25 % using suitable size/type pump after completion of Item Ser No 14 above, including Yield testing for the tube well not less than 08 Hrs continuously by "V" notch method as per IS : 2800-2 1979 to determine the safe pumping yield of tube well complete all as specified and as directed by the Engr-in-Charge. [Note: - (i) Yield test of borewell shall be carried out in the presence of GE. (ii) "V" Notch & other equipment included diesel driven pump set including fuel/ submersible cable for metered connection shall be arranged by the contractor and cost thereof deemed to be included in the quoted rate]
16Supply and fixing well capfor 200 mm bore ERW 8.00mm thick casing pipe made out ofMS plate 6 mm thick for covering tube wellduly welded with locking arrangement, including making holes for passing flat submersible cable and support chain complete all as specified and as directed.
17Supply, install, test and commission submersible pump set 7.5 HP capacity, 415Volt Ac 50 Hz, with Head Range of 120 to 312 m, discharge - 5.4 to 2.0 Cum/Hr suitable for 100 mm bore dia column pipe complete all as directed. Make: KSB or equivalent in Kirloskar
18Supply and lowering GI column pipe heavy duty (as per IS: 1239, Part-I) 50 mm dia bore 3 mtr in length both side MS flanged (12mm thick) duly welded including nuts, bolts, washers and rubber gasket for flange jointing including making suitable grooves for passing wire or cablecomplete all as specified and as directed
19S&F steel chain made out of6 mm dia (size 20mmX38mm) or SWR wire with PVC coating for holding submersible pump set/column pipe including necessary holding (MS) clamp nuts, bolts etc. complete all as specified & as directed.
20Supplying laying and testing PVC insulated submersible cable 6 Sq mm 3 core flat LT 1100volt grade heavy duty ISI marked with copper conductor and overall served with an outer sheath of PVC along the column pipe or passing through pipes or laid under floor of through walls etc jointing and testing complete.
21Supply and fixing mild steel well clamp suitable for 200 mm dia bore casing pipe made out of 200 mm x 16 mm thick MS plate fabricated to shape, including drilling holes, nuts, bolts washers etc complete all as specified and directed. [Note: Minimum 02 Nos well clamp shall be provided]
22Supply and fixing clamp suitable for 100 mm dia bore column pipe with clamp ends overlapping the casing pipe by not less than 600 mm, clamp should be made out of MS flat iron 150 mm x 16 mm size fabricated to shape, including drilling holes, nuts, bolts washers etc complete all as directed. [Note: Minimum 02 Nos clamp shall be provided]
23Supply only strata sample box with glass cover 3mm thick having internal dimension 1000mm x 600mm x 100mm made out of 20mm thick worught Ist class hard wood shisham with hinges , hasp and staple including polishing complete with samples at various depth every 3 mtr interval met in boring including lithological log strata chart in duplicate complete.
24Supply and fix gun metal non return screwed both ends, ISI marked suitable for for 50 mm bore GI pipe all as directed.
25M&L for geophysical survey report from recognized agency concluded by geophysical holding master"s degree in the stream of GEOPHYSICS to excatly pin point the location of proposed borewell for maximum yeild/output in accordance with CGWB report complete all as specified and directed.
26Supply,laying and testing 50 mm bore GI tubing (medium grade) with new fittings laying in trenches all as directed and specified.
27Supply and fixing in repair 50 mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipes or for unions as directed by the Engineer-in-Charge. all as per IS : 778-84 Marked CL-1 Pressure tested 2.4 Mpa .
28Supply & laying in trenches/fixed to pole, walls. etc LT, XLPE insulated, armoured,heavy duty electric power cable with aluminum conductor, 1100 Volts grade, cross sectional area 25 Sqmm, 4 core conforming to IS-7098 (Part-I)-1988 and testing complete as specified and directed.
29Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches and getting out in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
30Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
31Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed by the Engineer-in-Charge.
32Material and labour for sand cushioning for protection of underground cable, consolidatedand compacted with clean dry sand all as specified and as directed by the Engineer-in-Charge.
33Material and labour well burnt old size sub Class ‘B’ bricks, laid flat,in trenches for cable protection complete all as specified and as directed by the Engineer-in-Charge.
34M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead strip of size 32 x 6 mm by mean of bolts nuts, check nuts and washer of galvanised iron steel including necessary excavation, earth work, PCC chamber etc all as shown in electrical plate No.3 of SI 2009 Part-I and connected to earthing test point all as specified includingCI cover, funnel with GI watering pipe of 20mm bore medium grade & GI protection pipe 40mm bore light grade including testing etc complete all as specified & directed. (Length or earth lead strip & protection pipe shall be up to 7.5 mtr).(for panel)
35Testing of raw water for all parameters, chemical and bacteriological aspect such as ph value, dissolved solids, hardness as CaCo3, calcium, magnesium, chlorides, sulphates, nitrate, alkalinity,iron,turbidity NTU,miniral oil, colour hazen units, taste,odour,total coliform per 100 ml (microbiological test) & E coil per 100 ml (microbiological test),Arsenic & fluoride test (all ss per IS 10500:2012) from Govt laboratory [Note:- The Sample of raw water will be forwarded to the laboratory directly by the department duly sealed. The testing & Postal charge shall be borne by the contractor & report shall be submitted to the department / GE directly by the laboratory.]
36Supply, install, test and commission outdoortype cubicalLT panel boardsuitable for 3 phase, 4 wire, 415 Volts and CPRI approved, factory fabricated having modern fabrication and testing process which includes seven tanks pre treatment process, comprising of degreasing, rising, derusting, phosphating and preservation followed by anti corrosive painting (after applying two coats of metal primer) with siemens grey paint.The panel shall be provided with suitable gasket to make it dust/ vermin proof and degree of protection not less than IP-54 and general construction conforming to IS.The panel shall be made out of 3.15 mm thick CRCA sheet duly compertment wise for each control gear, front and back opening with sliding bolt type locking arrangement. The panel board shall be provided with proper ventillation, including suitable size of cable alley aluminium bus bar suitable for carrying of current200 Amps . Connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB"s (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator.The cubical shall have bottom channel of suitable size MC100 and angle iron 50x50x6mm thick legs of 75 cm long (45cm above ground and 30 cm below ground) and painted with 2 coats of smoke gray synthetic enamel paint over a coat of red oxide primer.Suitable bolts to fix GI earth busbar of size 50X6 mm shall be provided and a detachable pre drilled gland plate of powder coated shall be provided at bottom. All control wires shall be copper conductor, multistranded flexible and shall be bunched, tied, ferruled for proper identification and crimped including cable connections with adequate size aluminium lugs complete all as directed by the Engineer-in-charge.The panel shall comprise of the following(a) Incomming :MCCB 32 Amps, 4 pole, 25 KA- 01 NoMake Legrand/Schenider /L&T (b) Out going :MCCB25 Amps, 3 pole, 25 KA- 01 No Make Legrand/Schenider L&T(c) MCB TP 25 Amps, 10 kA, C curve - 01 No. Make: Legrand/Schneider/L&T (d) Multifunction meterLED C1 with RS 485, make: L&T -01 Set(e) CT 50/5 - 3 Nos (f) Indicator lamp LED type (RYB) (03 Nos)set-01 (g) Submersible Star Delta starter suitable for 10 HP motor with short circuit/ phase protection/low water level protection - 01 Each [Note :- 1. MCCBs are to be of fixed thermal and fixed magnetic setting type, complete all as directed by Engr-In-Charge.2. Excavation,earth work and PCC work (1:3:6) shall be deemed to be included in the quoted rate. 3.Design and drawing of panel board shall be got approved from GE before procurement/ incorporation in the work.]