Tender For Repair/Maintenance Of Lt Cable Distribution Network, Lt Panel, Earthing And Allied Works In Zone-Iii And Zone-Iv At Kanpur, kanpur-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Lt Cable Distribution Network, Lt Panel, Earthing And Allied Works In Zone-Iii And Zone-Iv At Kanpur. Submission Date for this Tender is 26-12-2023. Electrification Work Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40848363
Corrigendum : Tender For Repair/Maintenance Of Lt Cable Distribution Network, Lt Panel, Earthing And Allied Works In Zone-Iii And Zone-Iv At Kanpur
Open Tender
Indian
Uttar Pradesh
kanpur
26-12-2023

Tender Details

Tender For Repair / Maintenance Of Lt Cable Distribution Network, Lt Panel, Earthing And Allied Works In Zone-Iii And Zone-Iv At Kanpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 70180.0 /-
Tender Value
INR 35.09 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF LT CABLE DISTRIBUTION NETWORK, LT PANEL, EARTHING AND ALLIED WORKS IN ZONE-III AND ZONE-IV AT KANPUR
Sl. No. Item Description
1Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables complete all as specified and directed..
2Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed..
3Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.t.
4M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretchingand testing the cable complete all as specified and directed.
5M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
6M&L for cementconcrete ( 1:4:8) type D2 using 40mm graded stone aggregate for foundation filling of poles as mass concrete complete all as specified and directed.
7M&L for cementconcrete ( 1:3:6) type C2 using 40mm graded stone aggregate for foundation filling of stays complete all as specified and directed.
8Demolition of cement concrete (un-reinforced) in ground, floors or pavingsnot exceeding 15 cm thick below or above ground level complete all as specified and directed.
9M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified and directed.
10M&L for drilling manuallyin soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection cable & pipe upto 80 mm bore complete all as specified. Note: Depth of bore shall not be more than 1 Mtr from original ground level complete all as specified and directed. Pipe shall be measured and paid separately.
11Disconnecting electrically and taking out old unserviceable LT UG cables any type of size 25 Sqmm to 95 Sqmm 3.5 core all as spfd and directed.
12Disconnecting electrically and taking out old unserviceable LT UG cables any type of size 120 Sqmm to 240 Sqmm core all as spfd and directed.
13Supply and laying in trenches or fixing to wall/pole or passing through pipe of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core complete all as specified and directed. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
14All as per srl item No 13 above but cable of size 35 Sqmm 3.5 core complete all as specified and directed..
15All as per srl item No 13 above but cable of size 50 Sqmm 3.5 core complete all as specified and directed.
16All as per srl item No 13 above but cable of size 70 Sqmm 3.5 core complete all as specified and directed.
17All as per srl item No 13 above but cable of size 95 Sqmm 3.5 core complete all as specified and directed.
18All as per srl item No 13 above but cable of size 120 Sqmm 3.5 core complete all as specified and directed.
19All as per srl item No 13 above but cable of size 150 Sqmm 3.5 core complete all as specified and directed.
20All as per srl item No 13 above but cable of size 185 Sqmm 3.5 core complete all as specified and directed.
21All as per srl item No 13 above but cable of size 240 Sqmm 3.5 core complete all as specified and directed.
22S&F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core complete all as specified and directed.
23All as per item No 22 above but for 25 to 35 Sqmm 2 core size complete all as specified and directed.
24All as per item No 22 above but for 50 to 95 Sqmm size complete all as specified and directed.
25All as per item No 22 above but for 120 to 185 Sqmm size complete all as specified and directed.
26All as per item No 22 above but for 225 to 300 Sqmm size complete all as specified and directed.
27All as per item No 22 above but for 25 to 50 Sqmm size complete all as specified and directed.
28All as per item No 22 above but for 70 to 150 Sqmm size complete all as specified and directed.
29All as per item No 22 above but for 185 to 240 Sqmm size complete all as specified and directed.
30Disconnecting electrically and taking out old unserviceable HT UG cables any type of size 70 to 185 Sqmm 3 core all as spfd and directed.
31Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately.
32All as per item No-31 above but HT 11 KV cable of size 120 Sqmm complete all as specified and directed.
33All as per item No-31 above but HT 11 KV cable of size 185 Sqmm complete all as specified and directed.
34Supply and fix in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.
35Supply and fix in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
36Supply and fix cable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.
37Supply and fix cable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
38Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.
39Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
40S&F HT 11 KV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made,using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work complete all as specified and directed.
41M&L for replacement of GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
42All as per srl item No 41 but 50mm bore complete all as specified and directed.
43All as per srl item No 41 but 40mm bore complete all as specified and directed.
44Supply and fix bus bar chambers 300 mm longiron clad with 4 Nos 200 Amp rated copper strips complete fixed flush wall and making good the disturbed wall surfaces all as a requiredat site or directed.
45All as per srl item No 44 but with 2 Nos 100 Amp complete all as specified and directed.
46Repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing ofnew hinges and other material as required at site complete all as spfd and directed.
47S&F in replacement of notice board made out of plywood board with fixing ofcloth of best quality green colour supported by aluminium beading complete of size 1.5 mtr x 1.5 mtr fixing on wall with necessary arrangement complete all as specified and directed.
48Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not exceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M complete all as specified and directed.
49M & L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictly all branches in one place as directed by Engineer-in-Charge.
50Disconnecting electrically, dismantling from foundation with due care and setting aside old unserviceable LT panel box any type any size with all accessories complete all as specified and directed.
51M & L for Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron framefixed on RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 ka, four Nos 100 Amps 4 pole 25 ka, two Nos 63 Amps 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as required at site or directed.
52All as per item No 51 but for copper bus bar 600 Amps 3 phase 4 wire and for one incoming MCCB 400 Amps 4 pole 35/36 ka, outgoing two No 250 Amps 4 pole 35/36 ka, two Nos 100 Amps 4 pole 25 ka, two Nos 63 Amps 25 ka and MCB DP 63 Amps- 06 Nos complete all as specified and directed.
53S&F in replacement of MCCB 4 Pole 415 Volts3 phase 400 Amps 35/36 KA, thermal magnetic releasecomplete all as specified & directed.
54All as per item No 53 but MCCB 250 Amps 35/36 KA complete all as specified and directed.
55All as per item No 53 but MCCB 100 Amps 25 KA complete all as specified and directed.
56All as per item No 53 but MCCB 160 Amps 36 KA complete all as specified and directed.
57All as per item No 53 but 63 Amps 25 KA complete all as specified and directed.
58Detection of any type of fault in HT/LT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.
59M&L in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed incl testing on competion.
60All as per srl item No 59 but connected to galvanised iron strip 32x6mmEarthing lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3connected to earth test point complete all as specified and directed.
61S&F bushing boots for distribution transformer upto capacity 750 KVA complete all as specified and directed.
Disclaimer :