| 1 | S&F 200 AH VRLA type Battery bank of 2V X 55 Nos (110 V DC ) complete with all standard accessories including taking down of old unserviceable one and deposit to MES store complete all as specified and as directed.Notes:-(a)The battery bank consisting of 55 Nos of 2V 200AH VRLA type batteries with out put 110V DC.(b)If any defect noticed during warranty period/defect liability period the contractor shall replace the defective battery immediately with new one without any extra cost of department. (c)The accessories such as connectors, stand consisting of powder coated MS angle of suitable size to with stand the load of batteries shall deemed to include in the unit rate quoted. |
| 2 | S&F FRBC type Battery Charger of IN:415 AC, OT : 110V DC 50 A, complete with all standard accessories including taking down of old unserviceable and deposit to MES store complete all as specified and as directed. |
| 3 | S&F DC Cable single run 1 core 6.0 sqmm nominal cross sectional area multi strandedcopper conductor cable, over all PVC sheathed, 110 DC Volts grade confirming to IS-694-2010 (FRLS) heavy duty cable PVC insulatedand PVC sheathed including taking down old unserviceable one complete all as specified and as directed. |
| 4 | S&F DC Cable single run 1 core 25.0 sqmm nominal cross sectional area multi stranded copper conductor cable, over all PVC sheathed, 110 DC volts grade confirming to IS-694-2010 (FRLS) heavy duty cable PVC insulatedand PVC sheathed including taking down old unserviceable one complete all as specified and as directed. |
| 5 | M&L for earthing complete with galvanized steel plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the earth plate not less than 1.5 m below ground level connected to GI earth strip 20mm x 3mm dia by means of nuts, bolts, check nuts and washers galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft/loose soil, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI light grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8mm dia TMT bars @10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, charcoal and testing on completion, complete all as specified and as directed.Notes :-(a) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate as per colour code followed in Station.(b) If the desired earth resistance is not achieve during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible. |
| 6 | S&F sheet metal enclosure DC MCB DB 4 way locking system complete including removal of old unserviceable sheet metal enclosure complete all as specified and as directed. |
| 7 | S&F DC Contactor Three pole, 110 volts, including taking down old us one complete all as specified and as directed. |
| 8 | S&F AC Contactor Three pole, 220 volts, including taking down old us one complete all as specified and as directed. |
| 9 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and directed. |
| 10 | S&F PVC conduit pipe 20 mm dia all complete with and including taking down old unserviceable one complete all as specified and as directed. |
| 11 | Supply and erecting steel tubular swaged pole (type 410 SP-55) , 11.0 meter overall length confirming to suitable IS complete withcast iron base plate, finial taper plug bolts, nuts and screw including painting all external exposed steel surfaces with two coats of aluminium paint over a coat of red oxide zinc chrome primer and all internal surfaces & external surfaces in contract with concrete with two coats of black bituminous paint and marking of serial no on pole complete all as specified and as directed. |
| 12 | S&F LED flood light luminaires 100 Watts IP 65 type with lens including standard fittings pressure die cast aluminium housing with heat resistant toughened front glass housing with epoxy powder coated finish and, complete with control gear box and all accessories duly prewired and connecting to junction box and testing complete all as specified and as directed. |
| 13 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, FRLSscreened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 16 sqmm 4 core with all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete all as specified and as directed. Note: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this Schedule \"A\" part. |
| 14 | Excavation in trenches in soft/loose soil not exceeding 1.50m wide and not exceeding 1.50m in depth for underground cableand getting out all excavated materials andfor laying of cable including trimming sides and bottom of trenches etc complete all as specified and as directed. |
| 15 | Excavation in trenches in soft/loose soil not exceeding 1.50m wide and exceeding 1.5m and not exceeding 3.0m in depth for underground cable, pole and getting out all excavated materials andfor laying of cable including trimming sides and bottom of trenches etc complete all as specified and as directed. |
| 16 | Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cms in depth complete all as specified and as directed. |
| 17 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level n.exc (not exceeding) 1.5 mtr above the starting point complete all as specified and as directed. |
| 18 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. |
| 19 | Supply and laying sub class B bricks of size 25cmx15cmx7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 20 | M&L for PCC (1:4:8) type D2 with 40 mm graded stone aggregate in foundation filling for steel pole complete all as specified and as directed. |
| 21 | S&F 50 mm dia GI tubing light grade ISI marked laid in trenches/ laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and directed. |
| 22 | M&L for horizontal boring across the existing road without disturbing the road surface for insertingGI pipe complete all as specified and as directed. Notes:- (a) Removal of surplus soil shall be deemed to be include in the unit rate. (b) GI pipe will be measured and paid separately under relevant item of Schedule \"A\". |
| 23 | M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of stay assembly/struts/pole etc. (around the poles in pit) complete all as specified and as directed. |
| 24 | M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate for coping / pedestal of poles including necessary form work, fair finishing to exposed surfaces by using extra cement complete all as specified and as directed. |
| 25 | M&L for one run of 2.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) in existing position from pole junction box to light fitting complete all as specified and as directed. |
| 26 | S&F flood light bracket made out of angle iron 50 x 50 x 5mm by cutting, welding and well finishing suitable size complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and as directed. |
| 27 | S&F pole junction box (Loop-in-Loop Out) of size 250mm x 190mm x 150mm, made out of 2.00 mm CRCA sheet CPRI approved factory made, weather, dust & vermin proof with front door and suitable locking arrangement including applying two coats of powder coated paint over exposed external & internal surfaces with three phases and neutral busbar of size 20 x 3 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections mounted on hydrographic insulators with nuts & bolts at ends of busbar and one No SP 6 Amps ‘C’ series mounted on DIN rail including dismantling/taking out old unserviceable any type of busbar box from existing position all complete all as specified and as directed.Note: Making suitable nitch to taking out the junction box from existing position and cutting the existing pole foundation and making good disturbed surface with required PCC/plaster work and the same shall deem to be included in the unit rate. |
| 28 | M&L for earthing complete with galvanized steel plate electrodes of size 600 x 600 x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00mm earth lead by means of nuts, bolts, check nuts and washers including 15 mm bore galvanized iron pipe, light grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on completion, complete all as specified and as directed.Notes :-(a) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate as per colour code followed in Station.(b) If the desired earth resistance is not achieve during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible. |
| 29 | Taking down old unserviceable street light fittings without damaging and depositing to MES store yard complete all as specified and as directed. |
| 30 | S&F Blaze 010 v Dimmable LED street light 90 W 5700 K with SPD 10 KV LED street light luminaire with high power LED and unique peanut lens to ensure uniform light distribution , IP 66 type incl standard fittings pressure die cast aluminium housing with heat reistant toughened glass with epoxy powder coated finsh complete with Electronic driver, Surge protector not less than 10 KV and all accessories duly prewired complete all as specified and as directed. Make:CENTURY LED Model No: BLAZE 0-10V DIMMABLE LED Product Code - SPBL090C2191 or Techno Commercially equivalent make as listed in List of Makes and as approved by the GE. |
| 31 | M&L for one run of 1.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) in existing position from pole junction box to light fitting all complete all as specified and as directed. |