Tender For Construction/Retrofitting Of Pipe Water Supply Scheme At Tasgaon,Tal. Satara, Dist- Satara
BOQ
| Sl. No. | Item Description |
| 1 | Subwork No.1 - Capsule Type well |
| 2 | Item No.1Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.in soil 50 % |
| 3 | in Hard Murum 20 % |
| 4 | in soft rock 30 % |
| 5 | Item No.2Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack weldingassembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). |
| 6 | Item No.3Blast cleaning the surface of the old or new pipeline internally to remove all rust etc. complete, including providing copper slag/garnet, machinery, labour, cutting of pipes at required places and rewelding the same etc, complete as directed by Engineer-in-charge. (Pipes pieces if required for rewelding of old pipeline shall be paid separately.) |
| 7 | Item No.4Providing and applying primer and one coat of red oxide of iron paint externally including cleaning the surface of the pipes with steel scrappers, wire brushes,and metal cleaning solution, etc. |
| 8 | Item No.5Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating on pedestals or chairs upon prepared formation. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and transportation upto 500 M. etc. completed as specified. |
| 9 | Item No.6Welding in all positions with required number of runs, for M.S. pipes internally and / or externally including gauging wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification. |
| 10 | Item No.7Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. |
| 11 | Item No.8Proiding And Fixing G.I.Bend 100 mm dia |
| 12 | Item No.9floting arrengment Structural steel |
| 13 | Item No.10providing and fixing sintex tank |
| 14 | Item No.11providing and fixing vaccum carbonet gauge of 20 mm dia |
| 15 | Item No.12providing and fixing screw type foot valve |
| 16 | Subwork No.3- Rising MainItem No.1Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GSTlevied by GI & GOM in all respect etc. complete.HDPE 140 ø 6 kg/cm2 |
| 17 | Item No.2Providing & Supply of Electro Fusion Fittingsin accordance with BS EN12201: Part-3 suitablefor drinking water with in black/ blue colourmanufactured from compounded PE80/ PE100virgin polymer and compatible with PE80/PE100pipes, in pressure rating SDR11 with min PN12.5rated for water application and shall be inclusive ofall cost such as testing, inspection charges,transportation up to store, transit insurance,loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.Couplers 140 |
| 18 | Equal Tee 140 |
| 19 | LNPE 140 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 20 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below. |
| 21 | Item No.4Providing and supplying ISl mark CI D/F reflux valves (non-return valves ) of following dia including all taxes (Central and Local), railway freight, inspection charges unloding from railwaywagon,loadinginto truck, transportation upto departmentalstroes/ site, unloading, stacking etc. complete.Reflux valves as per I.S.5312 Part I (1984)125 mm |
| 22 | Item No.5Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve125 ø |
| 23 | Item No.6Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve, small orifice elastic ball resting on a gun metalorifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete.40 mm |
| 24 | Item No.7Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 |
| 25 | Item No.8Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd A-2/259)Lift 0 to 1.5 |
| 26 | Item No.9Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.5 |
| 27 | Item No.10Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. (Bd-A-5/259)Lift 0 to 1.5 M |
| 28 | Item No.11Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263 |
| 29 | Item No.12Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II140 mm |
| 30 | Item No.13Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position...Working pressure 6 kg/cm2140 ø |
| 31 | Item No.14Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.125 mm |
| 32 | Item No.15Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )125 ø |
| 33 | Item No.16ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover. |
| 34 | Item No.17Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) |
| 35 | Item No.18Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete. |
| 36 | Item No.19Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.)80 mm |
| 37 | 100 mm |
| 38 | Subwork No.3- b.Rising MainItem No.1Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GSTlevied by GI & GOM in all respect etc. complete.HDPE 140 ø 6 kg/cm2 |
| 39 | HDPE 90 mm - 6 kg/cm2 |
| 40 | Item No.2Providing & Supply of Electro Fusion Fittingsin accordance with BS EN12201: Part-3 suitablefor drinking water with in black/ blue colourmanufactured from compounded PE80/ PE100virgin polymer and compatible with PE80/PE100pipes, in pressure rating SDR11 with min PN12.5rated for water application and shall be inclusive ofall cost such as testing, inspection charges,transportation up to store, transit insurance,loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.Couplers 90 |
| 41 | Couplers 140 |
| 42 | Equal Tee 90 |
| 43 | Equal Tee 140 |
| 44 | LNPE 90 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 45 | LNPE 140 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 46 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.125 mm |
| 47 | Item No.4Providing and supplying ISl mark CI D/F reflux valves (non-return valves ) of following dia including all taxes (Central and Local), railway freight, inspection charges unloding from railwaywagon,loadinginto truck, transportation upto departmentalstroes/ site, unloading, stacking etc. complete.Reflux valves as per I.S.5312 Part I (1984)125 mm |
| 48 | 80 mm |
| 49 | Item No.5Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve125 ø |
| 50 | 80 mm |
| 51 | Item No.6Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete.32 mm |
| 52 | Item No.7Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 |
| 53 | Item No.8Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd A-2/259)Lift 0 to 1.5 |
| 54 | Item No.9Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.5 |
| 55 | Item No.10Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. (Bd-A-5/259)Lift 0 to 1.5 M |
| 56 | Item No.11Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263 |
| 57 | Item No.12Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II140 mm |
| 58 | 80 mm |
| 59 | Item No.13Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position...Working pressure 6 kg/cm2140 ø |
| 60 | 80 mm |
| 61 | Item No.14Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.125 mm |
| 62 | Item No.15Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )125 ø |
| 63 | 80 mm |
| 64 | Item No.16ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover. |
| 65 | As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover. |
| 66 | Item No.17Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) |
| 67 | Item No.18Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete. |
| 68 | Item No.19Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.)80 mm |
| 69 | 100 mm |
| 70 | Sub Work No.4 - Pumping Machinary 10 BHP, Discharge = 27325 LPH, Head = 39 m At CapsuleItem No.1Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stagesProvideduplicate set of submersible pump capable of discharging 27325 litres/hour against a total head 39 M be driven by 10 B.H.P electrical motor directly coupled to it . One pump will be in operation and one pump will be standby. |
| 71 | Item No.2Supplying and erecting flat flexible 3 core 10 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 72 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004.Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.100mm dia (Medium) |
| 73 | Item No.4Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 1100 mm dia |
| 74 | Item No.5Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)100 mm dia |
| 75 | Item No.6Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.100mm dia (Medium) |
| 76 | Item No.7Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)100 mm dia |
| 77 | Item No.8Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 78 | Item No.9Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 79 | Item No.10a) Supplying and erecting \"b\" class GI bend in position withnecessary material.100 mm dia |
| 80 | b) Supplying and erecting \"b\" classGI Teein position withnecessary material.100 mm dia |
| 81 | Item No.11Supplying and erecting GI sheet 1.6 mm (16 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.0.75x0.75x0.25=1.87 |
| 82 | Item No.12Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.20 kg |
| 83 | Item No.13Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. Up to 7.5 HP |
| 84 | Item No.14Main Switch metal clad 16 A upto 6 Hp , 32A upto 10 Hp, 63 A upto 20 Hp, 100 A MCCB for 25 Hp LT - 7 P.No. 39 |
| 85 | Item No.15Supplying and erecting bank of All Polypropylene capacitors with the standard capacities of 1,2,3,5,7,12.5,15,20 and 25 KVAR units of power factor correction for operation on 3 phase, 50 Hz, 400 V+/- 10% with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected and |
| 86 | Item No.16 Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc |
| 87 | Item No.17Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 88 | Item No.18Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 89 | Item No.19For Labour charges for internal wiring of panels including all material Add as below1) Up to 5 HP twin set panel Rs. 1995/- 2) 6 to 10 HP twin set panel Rs. 2658/- 3) 11 to 30 HP twin set panel Rs. 3323/- 4) For connected load more than 60 HP Add Rs.61/- per HP |
| 90 | Sub Work No.4 - Pumping Machinary 12.5 BHP, Discharge = 25617 LPH, Head = 49 m At CapsuleItem No.1Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stagesProvideduplicate set of submersible pump capable of discharging 25617 litres/hour against a total head 49 M be driven by 12.5 B.H.P electrical motor directly coupled to it . One pump will be in operation and one pump will be standby. |
| 91 | Item No.2Supplying and erecting flat flexible 3 core 10 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 92 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004.Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.125mm dia (Medium) |
| 93 | Item No.4Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 1125 mm dia |
| 94 | Item No.5Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)125 mm dia |
| 95 | Item No.6Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.125mm dia (Medium) |
| 96 | Item No.7Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)125 mm dia |
| 97 | Item No.8Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 98 | Item No.9Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 99 | Item No.10a) Supplying and erecting \"b\" class GI bend in position withnecessary material.100 mm dia |
| 100 | b) Supplying and erecting \"b\" classGI Teein position withnecessary material.100 mm dia |
| 101 | Item No.11Supplying and erecting GI sheet 1.6 mm (16 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.0.75x0.75x0.25=1.87 |
| 102 | Item No.12Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.20 kg |
| 103 | Item No.13Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. Up to 7.5 HP |
| 104 | Item No.14Main Switch metal clad 16 A upto 6 Hp , 32A upto 10 Hp, 63 A upto 20 Hp, 100 A MCCB for 25 Hp LT - 7 P.No. 39 |
| 105 | Item No.15Supplying and erecting bank of All Polypropylene capacitors with the standard capacities of 1,2,3,5,7,12.5,15,20 and 25 KVAR units of power factor correction for operation on 3 phase, 50 Hz, 400 V+/- 10% with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected and |
| 106 | Item No.16 Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc |
| 107 | Item No.17Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 108 | Item No.18Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 109 | Item No.19For Labour charges for internal wiring of panels including all material Add as below1) Up to 5 HP twin set panel Rs. 1995/- 2) 6 to 10 HP twin set panel Rs. 2658/- 3) 11 to 30 HP twin set panel Rs. 3323/- 4) For connected load more than 60 HP Add Rs.61/- per HP |
| 110 | Sub Work No.5 - Pumping Machinary 3 BHP, Discharge = 3416 LPH, Head = 21 m Item No.1Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stagesProvideduplicate set of submersible pump capable of discharging 3416 litres/hour against a total head 21 M be driven by 3 B.H.P electrical motor directly coupled to it . One pump will be in operation and one pump will be standby. |
| 111 | Item No.2Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 112 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004.Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.50mm dia (Medium) |
| 113 | Item No.4Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 114 | Item No.5Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 115 | Item No.6Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.50mm dia (Medium) |
| 116 | Item No.7Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 117 | Item No.8Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 118 | Item No.9Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 119 | Item No.10a) Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 120 | b) Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 121 | Item No.11Supplying and erecting GI sheet 1.6 mm (16 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.0.75x0.75x0.25=1.87 |
| 122 | Item No.12Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.20 kg |
| 123 | Item No.13Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. Up to 7.5 HP |
| 124 | Item No.14Main Switch metal clad 16 A upto 6 Hp , 32A upto 10 Hp, 63 A upto 20 Hp, 100 A MCCB for 25 Hp LT - 7 P.No. 39 |
| 125 | Item No.15Supplying and erecting bank of All Polypropylene capacitors with the standard capacities of 1,2,3,5,7,12.5,15,20 and 25 KVAR units of power factor correction for operation on 3 phase, 50 Hz, 400 V+/- 10% with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected and |
| 126 | Item No.16 Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc |
| 127 | Item No.17Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 128 | Item No.18Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 129 | Item No.19For Labour charges for internal wiring of panels including all material Add as below1) Up to 5 HP twin set panel Rs. 1995/- 2) 6 to 10 HP twin set panel Rs. 2658/- 3) 11 to 30 HP twin set panel Rs. 3323/- 4) For connected load more than 60 HP Add Rs.61/- per HP |
| 130 | Sub Work No.6 - Pumping Machinary 3 BHP, Discharge = 1724 LPH, Head = 35 m @ DhondewadaItem No.1Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stagesProvideduplicate set of submersible pump capable of discharging 1724 litres/hour against a total head 35 M be driven by 3 B.H.P electrical motor directly coupled to it . One pump will be in operation and one pump will be standby. |
| 131 | Item No.2Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 132 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004.Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.50mm dia (Medium) |
| 133 | Item No.4Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 134 | Item No.5Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 135 | Item No.6Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.50mm dia (Medium) |
| 136 | Item No.7Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 137 | Item No.8Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 138 | Item No.9Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 139 | Item No.10a) Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 140 | b) Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 141 | Item No.11Supplying and erecting GI sheet 1.6 mm (16 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.0.75x0.75x0.25=1.87 |
| 142 | Item No.12Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.20 kg |
| 143 | Item No.13Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. Up to 7.5 HP |
| 144 | Item No.14Main Switch metal clad 16 A upto 6 Hp , 32A upto 10 Hp, 63 A upto 20 Hp, 100 A MCCB for 25 Hp LT - 7 P.No. 39 |
| 145 | Item No.15Supplying and erecting bank of All Polypropylene capacitors with the standard capacities of 1,2,3,5,7,12.5,15,20 and 25 KVAR units of power factor correction for operation on 3 phase, 50 Hz, 400 V+/- 10% with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected and |
| 146 | Item No.16 Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc |
| 147 | Item No.17Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 148 | Item No.18Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 149 | Item No.19For Labour charges for internal wiring of panels including all material Add as below1) Up to 5 HP twin set panel Rs. 1995/- 2) 6 to 10 HP twin set panel Rs. 2658/- 3) 11 to 30 HP twin set panel Rs. 3323/- 4) For connected load more than 60 HP Add Rs.61/- per HP |
| 150 | Sub Work No.7 - Pumping Machinary 3 BHP, Discharge = 1724 LPH, Head = 35 m @ BhosalwadiItem No.1Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stagesProvideduplicate set of submersible pump capable of discharging 1724 litres/hour against a total head 35 M be driven by 3 B.H.P electrical motor directly coupled to it . One pump will be in operation and one pump will be standby. |
| 151 | Item No.2Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 152 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004.Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.50mm dia (Medium) |
| 153 | Item No.4Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 154 | Item No.5Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 155 | Item No.6Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.50mm dia (Medium) |
| 156 | Item No.7Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 157 | Item No.8Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 158 | Item No.9Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no. EA-EP |
| 159 | Item No.10a) Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 160 | b) Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 161 | Item No.11Supplying and erecting GI sheet 1.6 mm (16 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.0.75x0.75x0.25=1.87 |
| 162 | Item No.12Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.20 kg |
| 163 | Item No.13Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. Up to 7.5 HP |
| 164 | Item No.14Main Switch metal clad 16 A upto 6 Hp , 32A upto 10 Hp, 63 A upto 20 Hp, 100 A MCCB for 25 Hp LT - 7 P.No. 39 |
| 165 | Item No.15Supplying and erecting bank of All Polypropylene capacitors with the standard capacities of 1,2,3,5,7,12.5,15,20 and 25 KVAR units of power factor correction for operation on 3 phase, 50 Hz, 400 V+/- 10% with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected and |
| 166 | Item No.16 Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc |
| 167 | Item No.17Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 168 | Item No.18Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 169 | Item No.19For Labour charges for internal wiring of panels including all material Add as below1) Up to 5 HP twin set panel Rs. 1995/- 2) 6 to 10 HP twin set panel Rs. 2658/- 3) 11 to 30 HP twin set panel Rs. 3323/- 4) For connected load more than 60 HP Add Rs.61/- per HP |
| 170 | Subwork No.8- Switch Romm @ DhonewadiItem No.1Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 171 | Item No.2Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc complete. |
| 172 | Item No.3Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. |
| 173 | Item No.4Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. orTor Reinforcement |
| 174 | Item No.4Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 175 | Item No.5Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted ) |
| 176 | Item No.6Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) |
| 177 | Item No.7Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) |
| 178 | Item No.8Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement. |
| 179 | Item No.9Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar of following proportion superstructure including striking out & racking out joint watering and scafolding etc complete. |
| 180 | Item No.10Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 181 | Item No.11Providing and laying Rough shahabad stone flooring upto 40 mm. thick and of required width in plain / diamond pattern on a bed of bed 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. |
| 182 | Item No.12Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete |
| 183 | Item No.13Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete. |
| 184 | Item No.14Providing and applying washable powder distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat) etc .complete |
| 185 | Item No.15Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete |
| 186 | Item No.16Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x40 x 25 mm shutter single sheet of 24 gauge single leaf joined by fusion welding atappropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first and last rib should be 60 mm away from vertical edge of the shutter. the shutter shall be welded, with angle to from the periphery of the shutter. At the center of the frame there shall be angle welded to bifurcate the frame into segments with two leaf shutter square 12 mm square guard bars at 120 mm centerwith all accessories |
| 187 | Item No.17Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. |
| 188 | Subwork No.9- Switch Romm @ BhosalewadiItem No.1Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 189 | Item No.2Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc complete. |
| 190 | Item No.3Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. |
| 191 | Item No.4Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. orTor Reinforcement |
| 192 | Item No.4Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 193 | Item No.5Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted ) |
| 194 | Item No.6Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) |
| 195 | Item No.7Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) |
| 196 | Item No.8Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement. |
| 197 | Item No.9Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar of following proportion superstructure including striking out & racking out joint watering and scafolding etc complete. |
| 198 | Item No.10Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 199 | Item No.11Providing and laying Rough shahabad stone flooring upto 40 mm. thick and of required width in plain / diamond pattern on a bed of bed 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. |
| 200 | Item No.12Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete |
| 201 | Item No.13Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete. |
| 202 | Item No.14Providing and applying washable powder distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat) etc .complete |
| 203 | Item No.15Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete |
| 204 | Item No.16Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x40 x 25 mm shutter single sheet of 24 gauge single leaf joined by fusion welding atappropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first and last rib should be 60 mm away from vertical edge of the shutter. the shutter shall be welded, with angle to from the periphery of the shutter. At the center of the frame there shall be angle welded to bifurcate the frame into segments with two leaf shutter square 12 mm square guard bars at 120 mm centerwith all accessories |
| 205 | Item No.17Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. |
| 206 | Subwork No.10 - RCC ESR Capacity 25000 L Item No.1Designing (aesthetically), and constructing RCC Elevated Service Reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R. having capacity 500 m3 & not more than 6 m c/cfor E.S.R.having capacity above 500 m3 including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material chargesincluding lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design. providing and fixing accessories such as Stainless steel ladder inside and M.S. ladder with G.I. railingoutside, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, M.S.Grill gate of 2 Mtrs height with locking arrangement, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylic emulsion with silicon additives paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for underground parts of the structures and giving satisfactory water tightness test as per I.S. code The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge.The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.)The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 / 1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks.For design having more than 6 columns, provision of internal bracing is obligatory.Externalbracingsisalso obligatory.The entire structure shall be in M-300 mix only.Plainroundmildsteelbarsgrade-I conformingtoI.S.432part-I or high yield strength deformed bars conformingtoI.S.1786orI.S.1139 shall be used, grade-II mild steel bars will not be allowed.Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level.These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity.Staging shall have to be designed with stresses of M-200 concrete for ESR. Howeverall RCCconstructionshould be done in M-300.Theseratesare includingthe costof uplift pressure if any and entire dewatering during execution. In case of waterloggingareawherewateris stretch at shallow depth, extra provision of dewatering shall be made as per site condition.AllconditionsgivenintheMember Secretary\"sCircularNo. MJP/ TS-I/ 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed andadditional cost, if any, due to these conditionsis includedin the rates mentioned below.75%partrateshallbepayablefor reinforcementconcreteand plastering items of containers of E.S.R. till satisfactoryhydraulictesting for water tightnessisgiven;andtillthatwork shall be treated as incomplete.Theratesindicatedinthetableare excludingthecostofpipes,specials andvalvesrequiredforinlet,outlet, washout, overflow and bypass arrangement. The scope of work, however, includes costoferecting, laying and jointing of pipes and valves including cost of jointing materials upto 5Mbeyondouterfaceof outermost column.ForESRupto500cumcapacityC.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall beused.ForESRabove500cum capacityC.I./M.S.pipeassemblywith minimum 8 mm thickness upto 500 mm diaandminimum10mmthickness above 500 mm dia can be used with properanti-corrosiveepoxy treatment from inside and outside.Belowmentionedratesarefor foundations with individual footing with bearing capacity of20tonnes per squaremetre.Forraft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is morethan5 MT/sqmandupto10 MT/sqm.This%of5%or 7.5%is applicable for estimationof amount of lumpsumitem of ESR. For extra item due to change from individual foundationtoraft, actualincreasein concreteandsteelbepaidasper relevant DSR item.The rate shall be increased by 30% for bearing piles upto depth of 10 M and for further increased in depth by 5 M each, it shall be increasedby another10%. These rates are applicable where raft is not feasible. For pile foundations sulphate resistant cement shall only be used. Single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of ESR.The rates are applicable for staging heightof 12 M. Theseratesshallbe increasedor decreasedfor per metre variation in this staging height as below:Following rates are for seismic zone III. For zone IV, these rates shall be increased by 5% and for zone II, these rates shall be decreased by 5%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. (Seismic maps attached in this CSR). |
| 207 | Item No.2Providing & supplying ISI standard CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance , unloading from railway wagon, loading into truck transport to stores, unloading etc. complete as directed by Engineer-in-charge. Inlet80 mm dia.CI.D./F pipes |
| 208 | Outlet150 mm dia.CI.D./F pipes |
| 209 | Overflow80 mm dia.CI.D./F pipes |
| 210 | Washout80 mm dia.CI.D./F pipes |
| 211 | Item No.3Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeSluice valves PN-1 without bye-pass arrangement150 mm dia. Sluice valve - Outlet/Distribution |
| 212 | 80 mm dia. Sluice valve - Inlet/Bypass |
| 213 | 150 mm dia. Sluice valve - Washout |
| 214 | Item No.4Providing and making flanged joints to flanged C.I./M.S. pipes of all classes/specials etc. including cost of all jointing materials (rubber packing, nut bolts, etc.), labour, hydraulic testing etc. complete.80 mm |
| 215 | 150 mm |
| 216 | Item No.5Providing and supplying ISI standard CI flanged / S& S specials including all statutory duties & taxes such as GST levied by GOI & GOM in all respect, railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store /site, unloading stacking etc. complete. |
| 217 | Subwork No.11- WTPDesigning (aesthetically), providing, fabricating, Package Water Treatment Plant. At the shop, transporting to site, installing, testing and commissioning at the site, giving necessary one month’s free test and trial run with guarantee for one year, etc. complete.Prefabricated Package Water Treament Plant comprising following1.Rapid mixing Channelin M.s.Sheets and M.S. baffle.2.Flocculatornot less than 10 minutes detention, in M.S. prefabricated box, flocculation being achived either by glass pebbles of graded size or PVC tetrapod or equivalvent arrangement to ensure good floc formation. |
| 218 | Subwork No.12 - Distribution SystemItem No.1Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GSTlevied by GI & GOM in all respect etc. complete.HDPE 75 ø 4kg/cm2 |
| 219 | HDPE 90 ø 4kg/cm2 |
| 220 | HDPE 110 ø 4kg/cm2 |
| 221 | HDPE 140 ø 4kg/cm2 |
| 222 | HDPE 160 ø 4kg/cm2 |
| 223 | Item No.2Providing & Supply of Electro Fusion Fittingsin accordance with BS EN12201: Part-3 suitablefor drinking water with in black/ blue colourmanufactured from compounded PE80/ PE100virgin polymer and compatible with PE80/PE100pipes, in pressure rating SDR11 with min PN12.5rated for water application and shall be inclusive ofall cost such as testing, inspection charges,transportation up to store, transit insurance,loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.Couplers 75 |
| 224 | Couplers 90 |
| 225 | Couplers 110 |
| 226 | Couplers 140 |
| 227 | Couplers 160 |
| 228 | Equal Tee 75 |
| 229 | Equal Tee 90 |
| 230 | Equal Tee 110 |
| 231 | Equal Tee 140 |
| 232 | Equal Tee 160 |
| 233 | Reducer 90x75 |
| 234 | Reducer 110x90 |
| 235 | Reducer 140x110 |
| 236 | Reducer 160x140 |
| 237 | LNPE 75 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 238 | LNPE 90 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 239 | LNPE 110 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 240 | LNPE 140 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 241 | LNPE 160 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 242 | Item No.3Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe65 ø |
| 243 | 80 ø |
| 244 | 100 ø |
| 245 | 125 ø |
| 246 | 150 ø |
| 247 | Item No.4Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete.Without by pass arrangement - PN-1.65 ø |
| 248 | 80 ø |
| 249 | 100 ø |
| 250 | 125 ø |
| 251 | 150 ø |
| 252 | LABOURItem No.5Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 |
| 253 | Item No.6Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 |
| 254 | Item No.7Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in_x0002_charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.5 |
| 255 | Item No.8Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259)Lift 0 to 1.5 |
| 256 | Item No.9Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) from excavated stuff |
| 257 | Item No.10Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part IIHDPE 75 ø 4kg/cm2 |
| 258 | HDPE 90 ø 4kg/cm2 |
| 259 | HDPE 110 ø 4kg/cm2 |
| 260 | HDPE 140 ø 4kg/cm2 |
| 261 | HDPE 160 ø 4kg/cm3 |
| 262 | Item No.11Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position...HDPE 75 ø 4kg/cm2 |
| 263 | HDPE 90 ø 4kg/cm2 |
| 264 | HDPE 110 ø 4kg/cm2 |
| 265 | HDPE 140 ø 4kg/cm2 |
| 266 | HDPE 160 ø 4kg/cm3 |
| 267 | Item No.12Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe65 ø |
| 268 | 80 ø |
| 269 | 100 ø |
| 270 | 125 ø |
| 271 | 150 ø |
| 272 | Item No.13Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe65 ø |
| 273 | 80 ø |
| 274 | 100 ø |
| 275 | 125 ø |
| 276 | 150 ø |
| 277 | Item No.14Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )65 ø |
| 278 | 80 ø |
| 279 | 100 ø |
| 280 | 125 ø |
| 281 | 150 ø |
| 282 | Item No.15Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete100 mm x 225 mm (20 kg) |
| 283 | Item No.16Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)For Road Reconstruction PCC M150 |
| 284 | Item No.17Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.Net volume of refilling |
| 285 | Item No.18Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores80 mm |
| 286 | 100 mm |
| 287 | Item No.19Providing and supplying ISI standard CI flanged / S& S specials including all statutory duties & taxes such as GST levied by GOI & GOM in all respect, railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store /site, unloading stacking etc. complete. |
| 288 | Subwork No.13 - INFORMATORY SIGN BOARDS, TRIAL RUNItem No.1Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Chargewith two coats of greystove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground levelas per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete. |
| 289 | Subwork No.14 - Trial RunCommissioning, running and maintaining the scheme to quantities, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month |
| 290 | Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer inA) Household Connection without water meter (Comression Saddle+ISI Mark Ferrul) for HDPE & PVC pipeFor MDPE/UPVC Pipe Service Connection on Disribution main.(Without Road Crossing)For 15 mm Service connection |
| 291 | For MDPE/UPVC Pipe Service Connection on Disribution main.(With Road Crossing)For 15 mm Service connection |
AI Tender Summary
Tender Timeline
Nov 28, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedDec 05, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 07, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender