| 1 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 5001 to 8000 ml/min- Static priming vol: 180 to 350 ml- Maximum Hardshell Reservoir Capacity: 4000 to 4500 ml- Minimum Hardshell Reservoir Capacity: 200 to 300ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 7000 to 8000 ml/min- Membrane Surface area: 1.8 to 2.5 m² |
| 2 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 5001 to 8000 ml/min- Static priming vol: 180 to 350 ml- Maximum Hardshell Reservoir Capacity: 4000 to 4500 ml- Minimum Hardshell Reservoir Capacity: 200 to 300ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 7000 to 8000 ml/min- Membrane Surface area: 1.8 to 2.5 m² |
| 3 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 4000 to 6000 ml/min- Static priming vol: 120 to 175 ml- Maximum Hardshell Reservoir Capacity: 3000 to 4200 ml- Minimum Hardshell Reservoir Capacity: 70 to 150 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 4000 to 5000 ml/min- Membrane Surface area: 1.0 to 1.5 m² |
| 4 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 4000 to 6000 ml/min- Static priming vol: 120 to 175 ml- Maximum Hardshell Reservoir Capacity: 3000 to 4200 ml- Minimum Hardshell Reservoir Capacity: 70 to 150 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 4000 to 5000 ml/min- Membrane Surface area: 1.0 to 1.5 m² |
| 5 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 2000 to 3000 ml/min- Static priming vol: 90 to 145 ml- Maximum Hardshell Reservoir Capacity: 1600 to 3000 ml- Minimum Hardshell Reservoir Capacity: 15 to 70 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 2000 to 3000 ml/min- Membrane Surface area: 0.6 to 1.5 m² |
| 6 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 2000 to 3000 ml/min- Static priming vol: 90 to 145 ml- Maximum Hardshell Reservoir Capacity: 1600 to 3000 ml- Minimum Hardshell Reservoir Capacity: 15 to 70 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 2000 to 3000 ml/min- Membrane Surface area: 0.6 to 1.5 m² |
| 7 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 801 to 1500 ml/min- Static priming vol: 46 to 90 ml- Hardshell Reservoir Capacity: 600 to 1500 ml- Cardiotomy filter: 20 to 40 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Membrane Surface area: 0.27 to 0.50 m² |
| 8 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 801 to 1500 ml/min- Static priming vol: 46 to 90 ml- Hardshell Reservoir Capacity: 600 to 1500 ml- Cardiotomy filter: 20 to 40 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Membrane Surface area: 0.27 to 0.50 m² |
| 9 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: upto 800 ml/min- Static priming vol: 30 to 45 ml- Hardshell Reservoir Capacity: upto 500 ml- Cardiotomy filter: 20 to 40 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Membrane Surface area: 0.20 to 0.26 m² |
| 10 | Membrane Oxygenator | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir and Cardiotomy Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: upto 800 ml/min- Static priming vol: 30 to 45 ml- Hardshell Reservoir Capacity: upto 500 ml- Cardiotomy filter: 20 to 40 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Membrane Surface area: 0.20 to 0.26 m² |
| 11 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 5001 to 8000 ml/min- Static priming vol: 180 to 350 ml- Maximum Hardshell Reservoir Capacity: 4000 to 4500 ml- Minimum Hardshell Reservoir Capacity: 200 to 300ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 7000 to 8000 ml/min- Membrane Surface area: 1.8 to 2.5 m²Specifications of Arterial Filter:- Maximum Blood flow rate: 6 to 8 lit/min- Low Priming Volume, Inlet and Outlet 3/8 For Adult |
| 12 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 5001 to 8000 ml/min- Static priming vol: 180 to 350 ml- Maximum Hardshell Reservoir Capacity: 4000 to 4500 ml- Minimum Hardshell Reservoir Capacity: 200 to 300ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 7000 to 8000 ml/min- Membrane Surface area: 1.8 to 2.5 m²Specifications of Arterial Filter:- Maximum Blood flow rate: 6 to 8 lit/min- Low Priming Volume, Inlet and Outlet 3/8 For Adult |
| 13 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 4000 to 5000 ml/min- Static priming vol: 120 to 175 ml- Maximum Hardshell Reservoir Capacity: 3000 to 4200 ml- Minimum Hardshell Reservoir Capacity: 70 to 150 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 4000 to 5000 ml/min- Membrane Surface area: 1.0 to 1.5 m²Specifications of Arterial Filter:- Maximum Blood flow rate: upto 5 lit/min- Low Priming Volume, Inlet and Outlet 3/8 For Small Adult |
| 14 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 4000 to 5000 ml/min- Static priming vol: 120 to 175 ml- Maximum Hardshell Reservoir Capacity: 3000 to 4200 ml- Minimum Hardshell Reservoir Capacity: 70 to 150 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 4000 to 5000 ml/min- Membrane Surface area: 1.0 to 1.5 m²Specifications of Arterial Filter:- Maximum Blood flow rate: upto 5 lit/min- Low Priming Volume, Inlet and Outlet 3/8 For Small Adult |
| 15 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 2000 to 3000 ml/min- Static priming vol: 90 to 145 ml- Maximum Hardshell Reservoir Capacity: 1600 to 3000 ml- Minimum Hardshell Reservoir Capacity: 15 to 70 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 2000 to 3000 ml/min- Membrane Surface area: 0.6 to 1.5 m²Specifications of Arterial Filter:- Maximum Blood flow rate: 3.2 to 5 lit/min- Low Priming Volume, Inlet and Outlet 3/8 For Paediatric |
| 16 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 2000 to 3000 ml/min- Static priming vol: 90 to 145 ml- Maximum Hardshell Reservoir Capacity: 1600 to 3000 ml- Minimum Hardshell Reservoir Capacity: 15 to 70 ml- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 2000 to 3000 ml/min- Membrane Surface area: 0.6 to 1.5 m²Specifications of Arterial Filter:- Maximum Blood flow rate: 3.2 to 5 lit/min- Low Priming Volume, Inlet and Outlet 3/8 For Paediatric |
| 17 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 800 to 2000 ml/min- Static priming vol: 35 to 70 ml- Maximum Hardshell Reservoir Capacity: 700 to 1500 ml- Minimum Hardshell Reservoir Capacity: 15 to 30 ml,- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 800 to 2000 ml/min- Membrane Surface area: 0.3 to 0.7 m²Specifications of Arterial Filter:- Maximum Blood flow rate: 0.7 to 2.5 lit/min- Low Priming Volume, Inlet and Outlet 1/4 For Infant and Neonatal |
| 18 | Membrane Oxygenator with Integrated Arterial Filter | Membrane Oxygenator Efficient Heat Exchanger with Surface coating- With Hardshell Venous Reservoir, Cardiotomy Filter- Integrated Arterial Filter- With temperature probe and stand whenever Required- Recommended Max Blood flow rate: 800 to 2000 ml/min- Static priming vol: 35 to 70 ml- Maximum Hardshell Reservoir Capacity: 700 to 1500 ml- Minimum Hardshell Reservoir Capacity: 15 to 30 ml,- Venous Reservoir filter: 20 to 47 µ- Suction inlet No.: minimum 4- Filtered quick prime No.: minimum 1- Filter luer No.: minimum 2- Venous blood flow: 800 to 2000 ml/min- Membrane Surface area: 0.3 to 0.7 m²Specifications of Arterial Filter:- Maximum Blood flow rate: 0.7 to 2.5 lit/min- Low Priming Volume, Inlet and Outlet 1/4 For Infant and Neonatal |
| 19 | Membrane Oxygenator with Leucocyte and Lipid Reduction Filter | Reservoir Capacity: 4000 to 4500 ml- Suitable For VAVD- Venous Inlet, 1/2" with 3/8" AdapterVenous Reservoir Outlet 3/8"- Vented / Vaccum Port 1/4"- 4 Filtered Ports 1/4", 1 of those with 1/4" Luer Lock Adapter- 2 Filtered Port 3/8"- 2 Filtered Luer Lock Ports- 2 Filtered Post Lock - Luer Lock- 1 Non Filtered Luer Lock |
| 20 | Membrane Oxygenator with Leucocyte and Lipid Reduction Filter | Reservoir Capacity: 4000 to 4500 ml- Suitable For VAVD- Venous Inlet, 1/2" with 3/8" AdapterVenous Reservoir Outlet 3/8"- Vented / Vaccum Port 1/4"- 4 Filtered Ports 1/4", 1 of those with 1/4" Luer Lock Adapter- 2 Filtered Port 3/8"- 2 Filtered Luer Lock Ports- 2 Filtered Post Lock - Luer Lock- 1 Non Filtered Luer Lock |
| 21 | Leukocyte Arterial Filter | Maximum Blood Flow Rate: up to 6 lit/min, - Low Priming Volume- Inlet and Outlet 3/8- Filter: 40µ- Polyester- Leukocyte Reducing Media |
| 22 | Leukocyte Arterial Filter | Maximum Blood Flow Rate: up to 6 lit/min, - Low Priming Volume- Inlet and Outlet 3/8- Filter: 40µ- Polyester- Leukocyte Reducing Media |
| 23 | Tissue Stabilizer With Canister Tubing Set (For Off pump CABG) - Metallic | - |
| 24 | Tissue Stabilizer With Canister Tubing Set (For Off pump CABG) - Metallic | - |
| 25 | Non Sternotomy Cardiac Stabilizer (MIDCABG) | - |
| 26 | Non Sternotomy Cardiac Stabilizer (MIDCABG) | - |
| 27 | Non Metallic Cardiac Stabilizer | - |
| 28 | Non Metallic Cardiac Stabilizer | - |
| 29 | Heart Positioners (For Off pump CABG) | - |
| 30 | Heart Positioners (For Off pump CABG) | - |
| 31 | Heart Positioner for MIDCABG | - |
| 32 | Heart Positioner for MIDCABG | - |