Uttar Pradesh Power Transmission Corporation Limited-UPPTCL has published Supply Of Hardware And Fittings, Clamps Etc & Erection Of Structure & Equipments For Extention Of 132Kv Main+Transfer Bus And Adding 01 Nos 132Kv Bay For M/S Amba Shakti Steels Limited At 220Kv Substation Nara Under Electricity Transmission Division Muzaf. Submission Date for this Tender is 05-12-2023. Transmission Line Tenders in Muzaffarnagar Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Dec-2023 | Corrigendum in BOQ | Other | 05-12-2023 |
2 | 04-Dec-2023 | Corrigendum in BOQ | Financial Bid | 05-12-2023 |
Sl. No. | Item Description |
1 | SCHEDULE Q-1(WORK ) |
2 | Erection of Main & Auxiliary structure consisting of AKR, BKR, ABR, APR, YMR, BBL, BCT, ALP etc. including all allied works complete in all respect. Department shall provide structure & nut and bolts etc. The works shall be strictly carried out as per drawing & technical specification. |
3 | Erection of 145 KV SF-6 Circuit Breaker. |
4 | Erection of 145 KV PT |
5 | Erection of 145 KV Current Transformer. |
6 | Erection of 145 KV Control & Relay panel |
7 | Erection of 120 KV Lightning Arrester |
8 | Erection and mounting of145 KVCT/PT Junction Box. |
9 | Erection of 145 KV Bus & Line Isolator |
10 | Erection of 145 KV Post Insulator for support. |
11 | Erection of cable termination kit |
12 | Laying of 40 mmdiaM S round bar below the ground level upto earthing earth mat by the cutting, straightening, welding, painting, excavation of tench back filling of trench after laying of earthmat including shifting of MS round bar from storeplace at the Sub-Station to switchyard. |
13 | Fabrication of 3 meter long electrode with 40 mm dia M S round bar having 150 mm long conical shape by digging cutting, striaghtening etc. and then placing it verticall. inside the ground with Top 700mm below the ground level including shifting of MS round bar from storage place at the Sub-Staiton to switchyard. |
14 | Making of cross joint of above laid 40 mm dia M S roundbelow the ground level by duc welding at all 4 corners includingwelding of suitable size 2 no M S angle pieces on opposite corners of the corssjoint. |
15 | Making of end joint of above laid 40 mm dia M S round bar with Top of the already vertically pierced M S electrodes 700 mm below thegournd level by duc welding. |
16 | Making of 300 mm long lap joint of above already laid round bar to connecting existing earth mat of the Sub-station. |
17 | Earthing of equipments by cutting straightening, bending, laying 700 mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipments structure.Excavation of trenches, its back filling and all other associated work as required to complete the work. |
18 | Laying of MS Flat of size 75x10 mm |
19 | Laying of MS Flat of size 50x6 mm |
20 | Laying of MS Flat of size 25x6 mm |
21 | Stringing of variousThree Phase Jack Bus ,Main Bus & Transfer bus with ACSR Moose/panther/tarantulla conductor as mentioned below. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification. |
22 | 132 KV Main Bus |
23 | 132 KV Transfer Bus |
24 | 132 KV Jack Bus |
25 | Jumpering, interconnection of equipment with specified conductor of various 132 KV equipments with main/Transfer/Jack Bus Bar of ACC Tarantulla / ACSR Moose/Zebra/Panther conductor. The work includes cutting of conductor, bending in proper shap, clamping with the help of clamps and all other associated work to complete the work. |
26 | Laying of following size control cable in trench/cable trays from different control room equipments to 220/132 KV CB, CT,CVT and their juntion boxes. Transformer marshaling box, isolators box and other outdoor equipments installed in 220/132 KV switch yard as per cable schedule including carriage of cable drum from storeand all other associated work. |
27 | 2 core x 2.5 mm2 |
28 | 4 core x 2.5 mm2 |
29 | 6 core x 2.5 mm2 |
30 | Termination of following size control cable as laid above as per cable schedule including making necessory holes in glands plate or box where ever required fixing of cable glands of appropriate size ,lugging and ferruling of each core and other associated work to complete the job satisfactorily.(the rates of termination of control cable including all cores of cable at both end.) |
31 | 2 core x 2.5 mm2 |
32 | 4 core x 2.5 mm2 |
33 | 6 core x 2.5 mm2 |
34 | Ring earthing(120KV LA) of 3 meter long 40mm ms round having 150mm conical shape.Its peicing vertically inside the ground below 700mm.All 06 rod arrenge in rectangular manner and connecting all 06 nos electrode with 75x10/50x6mm ms flat laid on its edge(all above work in one job) |
35 | SCHEDULE Q-2(SUPPLY ) |
36 | single Tension fitting for PANTHERConductor suitable for 132KV Discinsulator without turn buckle. |
37 | single Tension fitting for PANTHERConductor suitable for 132KV Discinsulator with turn buckle. |
38 | single Tension fitting for ZEBRAConductor suitable for 132KV Discinsulator without turn buckle. |
39 | single Tension fitting for ZEBRAConductor suitable for 132KV Discinsulator with turn buckle. |
40 | Boltedtype TensionfittingforTwin Tarantulla conductor without turn buckle for 132 KVMain Bus suitable for each disc stringing 10 Nos, 70 KN disc insulators with hardware fitting D shackle, eye socket, Ballhook.Yorkplate, I-cleveistensionclampetc.aspertechnical specification. |
41 | Boltedtype TensionfittingforTwin Tarantulla conductorwith turn buckle for 132 KVMain Bus suitable for each disc stringing 10 Nos, 70 KN disc insulators with hardware fitting D shackle, eye socket, Ballhook. |
42 | Single Suspension fitting for PANTHER Conductor. |
43 | Single Suspension fitting for ZEBRA Conductor. |
44 | MS Flat of 75x10 mm |
45 | MS Flat of 50x6 mm |
46 | MS Flat of 25x6 mm |
47 | 4 Bolted Type PG clamp suitable for Tarantulla to Tarantulla Conductor Complete with HDG nut bolt & washer. |
48 | 4 Bolted Type PG clamp suitable for Tarantulla TO panther Conductor Complete with HDG nut bolt & washer. |
49 | 4 Bolted Type PG clamp suitable for Zebra to Zebra Conductor Complete with HDG nut bolt & washer. |
50 | 4 Bolted Type PG clamp suitable for Zebra to Panther Conductor Complete with HDG nut bolt & washer. |
51 | 4 Bolted Type PG clamp suitable for panther to panther Conductor Complete with HDG nut bolt & washer. |
52 | Bus Post clamp suitable for panther conductor complete with hot dip galvanized nut, bolts & washer. |
53 | GI pipe 1.25 inch |
54 | Name plate as per sample |
55 | phase plate as per sample |
56 | danger plate as per sample |
57 | Fire Extinghusher foam type 50 ltr |
58 | Fire Extinghusher CO2 type 11KG |
59 | Fire Extinghusher CO2 type 4.5KG |
60 | sand buckets |
61 | stand for sand buckets as per sample |
62 | Providing 150 Watt LED flood light fitting complete with all accessories of standard (ISI) make like Anokhi/Syska/ Greatwhite. |