Military Engineer Services has published Tender For Repair/Maintenance Of Focus/Flood Lights Highmast Light And Allied Works At Nda Khadakwasla.. Submission Date for this Tender is 25-12-2023. Couplers Tenders in khadakwasla Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

40818886
Corrigendum : Tender For Repair/Maintenance Of Focus/Flood Lights Highmast Light And Allied Works At Nda Khadakwasla.
Tender
Indian
Maharashtra
Khadakwasla
25-12-2023

Tender Details

Tender For Repair / Maintenance Of Focus / Flood Lights Highmast Light And Allied Works At Nda Khadakwasla.; 1 Taking Down The Existing Light Fittings On Multi Mounting Brackets From 16 / 21 Mtrs Highmast Pole By Taking On Ground Repairs / Replacing The Defective Parts Like Electronic Drivers Connection Wires And Refixing The Same To Its Original Position Complete All As Specified And Directed.Note: ( I ) Cost Of Spares , Electronic Drivers, Connection Wires Replaced Against Above Mentioned Item Above Mentioned Item Will Be Measured & Paid For Separately Under Respective Items Of Sch A Here-In-Below. ( Ii ) The Defects / Repair Of The Floodlight Making Them Functional After Handing Over Defective Floodlights Of Highmast ( Iii ) Maintaining Proper Record Of Repair / Maint In A Binded Register Duly Bringing Out The Details Of Spares Replaced On Each And Every Flood Light And Gettingit Authenticated. ( Iv ) Safety Of His Men Engaged For Executing The Work Along With Safety Equipment And Clothes For The Men Shall Be Maintained. ( V ) Vehicle Mounted Hydraulic Ladder Shall Be Provided On ContractorS Request Which Will Be Measured Separately Under Schedule C. 2 Supply Only Following Flood Light Spares Of Branded Make As Mentioned In The List Of Make Enclosed With Particular Specifications For Replacement :- Mcb Tpn 230 Volts C Curve 63 Amps 3 Ditto All As Per Item No 2 Above But Mcb Tpn 230 Volts C Curve 40 Amps Make : L&T / Indoasian / Legrand 4 Ditto All As Per Item No 2 Above But Digital Time Switch, Din Type Daily / Weekly With 2 Change Over ( Co ) , 16 Amps 230 Volts Make : L&Tor Legrand / Indoasian 5 Ditto All As Per Item No 2 Above But Power Contactor 16 / 18 Amps 3 Pole A.C. With 230 Volts Coil 6 Ditto All As Per Item No 2 Above But Power Contactor 40 Amps 3 Pole A.C. With 230 Volts Coil. 7 Ditto All As Per Item No 2 Above But Pvc Insulated Copper Conductor Frls Grade Two Core Cable 2.5 Sqmm, Isi Marked 8 Ditto All As Per Item No 2 Above But Pvc Insulated Aluminium Conductor Frls Grade Two Core Cable 2.5 Sqmm, Isi Marked 9 Ditto All As Per Item No 2 Above But Mccb 63 Amps 4 Pole 415 V 10 Ditto All As Per Item No 2 Above But Mcb Dp 230 Volts B Curve 6-32 Amps 11 Ditto All As Per Item No 2 Above But Electronic Driverfor 200 Watts Flood Lights Make Should Be As Per The Existing Manufacturer 12 Ditto All As Per Item No 2 Above But Electronic Driverfor 150 Watts Flood Lights Make Should Be As Per The Existing Manufacturer 13 Ditto All As Per Item No 2 Above But Electronic Driverfor 100 Watts Flood Lights Make Should Be As Per The Existing Manufacturer 14 Ditto All As Per Item No 2 Above But Electronic Driverfor 50 Watts Flood Lights Make Should Be As Per The Existing Manufacturer 15 Ditto All As Per Item No 2 Above But Surge Protection Device ( Spd ) Of Capacity 10 / 20 Kv Compatible With Industrail & Outdooor Led Fixtures Make Should Be As Per The Existing Manufacturer 16 Dismantling / Taking Down Thepole Upto 16 / 21 Metre Height Of High Mast Light By Engaging Suitable Crane And Repairing By Replacing The Unserviceable Top Pully Of Pole And Other Part Such As Winch Motor, Steel Wire, Power Cable And Servicing , Toping Of Oil And Greasing The Gear Wheel Assemblyand Hoisting, Refixing And Connecting Up Complete All As Specified And Directed.Note : ( A ) The Repair Oflight Fittings And Light Fitting Spares Are Measured And Paid Separately. ( B ) Spares Such As Steel Wire, Power Cable Etc Will Be Measured And Paid Separately. ( C ) The Entire Work Shall Be Carried Out With Well Experienced Professionals Who Undertake The High Mast Poles Dismantling / Repair Works. ( D ) The Quoted Rate Shall Includes Provn Of Minor Spares Such As Screws, Bolt / Nuts, Grease Etc 17 Supply Onlystainless Steel Rope Twisted Of Size10mm / 6 Mm Dia With Necessary Connections Proper Binding On Both Sides From Bottom Drum Mast Top Connecting Hook Complete All As Specified And Directed. 18 Supply Only Gear Box Oil Of Grade Ep 90 / 140 In Standard Packed / Sealed Container Including Drain Out Old Gear Box And Filling Up New Gear Box Oil Complete All As Specified And Directed.Make : Hp / Servo / Valvoline 19 Disconnecting Electric Connectionand Taking Down Carefullyfractional Motor From Highmast Housing Of Any Type And Capacity As Described Below: -Removing The Burnt Winding Ofmotor Rewinding With Super Enameled Copper Winding Wire Of Suitable Gauge Or Of Matching Size To The Exisiting Wires Including All Insulating Material Such As Insulation Paper Sleeve, Tape, Varnishing Etc And Reassembling, Testing, Transporting Back To Site And Refixing To Original Position Complete All As Specified And Directed. 20 Supply Only3 Phase Induction Motor Of 1Hp Heavy Duty 415 V Ac50 Hz 1500 Rpm Suitable For Lifting Of Highmast Winch Complete All As Specified And Directed. 21 Supply & Laying, Jointing & Testing Of Ug Lt Cables Xlpe Insulated, Aluminium Conductor Multi Stranded Armoured Heavy Duty 1100 Volt Grade Cross Sectional Area 16 Sqmm 4 Core Laid In Trenches / Ducts / Along Poles / Through Pipe Under Road Etc With New Aluminium Lugs Of Cable Size Including Taking Out Of Existing Unserviceable Cable Complete All As Specified And Directed. 22 Ditto All As Per Item No 21 Above But Size 10 Sqmm 4 Core 23 Ditto All As Per Item No 21 Above But Size 4 Sqmm 3 Core 24 Excavation In Trenches In Hard / Dense Soil N.Exc 1.5 M Wide And Not Exceeding 1.5 Mts In Depth In Wide For Laying Of Cables And N Exc 1.5 Mtr In Depth And Getting Out Incl Dressing / Trimming Sides And Levelling / Grading And Ramming Of Bottom Of Excavation Complete All As Specified And Directed. 25 Returning, Filiing In Incl Spreading, Leveling Watering And Well Ramming Excavated Soil Inlayers Not Exceeding 25 Cm Thick Each, Filling Back In Trenches After Cables Have Been Laid And Tested Complete All As Specified And Directed. 26 Removing Excavated Surplus Soil Obtained From Excavation To A Distance Not Exceeding 1.5 M Above The Starting Point Complete All As Specified And Directed. 27 Supply And Laying 40 Mm Outer Dia, Double Walled Corrugated ( Dwc ) Hdpe Duct Pipe Confirming To Is-16205 Pt-24 With Antirodent And Non Flame Propogating Properties Of Approved Colour Complete With Fittings I.E Coupler, Tee, Elbow Clamp For Cable Protection Including Taking Down Old Unserviceable Pipe Complete All As Specified And Directed. 28 Supply And Fix In Replacement Of Sintex Box Thermo Plast ( Weather Proof ) Ip 66, On Flood Light Poles Made Out Of Thermoplastic Of Size 140Mm X 140 Mm X 95 Mm Size Withconnector For Connecting Incomming And Outgoing Of Cableincluding 01 No Of Mcb Sp 6 Amps To Control The Pole Light Circuit Andms Brackets Made Out Of 32 X 4 Mm Flats For Fixing The Box On Post Complete With Nuts, Bolts And Wahers And Suitable Size Of Double Compression Cable Glands For Incomming, Outgoing Of Cable Complete All As Specified And Directed.Make: Sintex Cat Pat No Gsjb-1414 Or Equivalent In Makes As Mentioned At Makes List In Ps 29 S&F Distribution Box 2 Module 230V, 5 Hz, Ip-65 & Ik-09 Class-Ii, Weatherproof Cabinets, Door And Cabinet Fully Reversible, Removable Chassis And Faceplates, Including Weatherproof Glands, Rails Qty-1 Nos, Coppper Fork Type 100 A Busbars As Short Link Including End Caps Complete All As Specified And Directed. 30 S&F In Replacement Mcb Db 02 Way Spn ( Single Door ) Sheet Metal Enclosure Factory Made Suitable For Mcb DbS 240 Voltswith 200 Amp Rated Busbar, Neutral & Earthing Link Bar, Surface Mounting Complete Including Mcb Spn 06 Amp 230V, 50 Hz Complete All As Specified And Directed. 31 M&L For Cutting Hard Standing By Providing Suitable T&P To Make Suitable Size Bore For Supply & Fixing 32 Mm Dia Pipe In Road / Cutting Hard Etc. Including The Cost Of Making Good The Disturbed Surface And Matching With Existing ( Chequered Tiles / Road / Pcc ) Complete All As Specified And Directed.Note : Quoated Rate Shall Includes Supply Of 32 Mm Dia Gi Pipe 32 S & F In Replacementof 100 Watts Flood Light White In Colour, Lm6 Aluminium Or Higher Grade Powder Coated And Water Proof Pressure Die Cast Aluminium Enclosure, With Inbuilt Electronic Drivers And Ip 66 Protection Complete , Single Phase, Suitable For Highlighting Architectural Facade And General Purpose Lighting Etc Fixing In Ms Chanel By Drilling Hole Of Suitable , Size, Using Nut, Bolts And Washers Of Suitable Size Including Suitable Mounting Structureas Reqd At The Site Complete All As Specified And Directed. Make: Havells Cat Part No. Jetaalbafloodlight100w Or Equivalent In Makes As Mentioned At Makes List In Ps 33 S & F In Replacement Of 150 Watts Flood Light White In Colour, Lm6 Aluminium Or Higher Grade Powder Coated And Water Proof Pressure Die Cast Aluminium Enclosure, With Inbuilt Electronic Drivers And Ip 66 Protection Complete , Single Phase Suitable For Highlighting Architectural Facade And General Purpose Lighting, Etc Fixing In Ms Chanel By Drilling Hole Of Suitable Size, Using Nut, Bolts And Washers Of Suitable Size Including Suitable Mounting Structure As Reqd At The Sitecomplete All As Specified And Directed. Make:Havells Cat Part No Jetaairisfl150wled757arnbltg Or Equivalent In Makes As Mentioned At Makes List In Ps 34 S & Fin Replacement Of 200 Watt Led Flood Light Luminaire With Separate Driver Assemble Boxwith Secondary Optics Made In Pressure Die Cast Housing And Heat Sink In Aluminium Extrusion And Ip 66, With Suitable Mounting Structure As Per Site Requirement Complete All As Specified And Directed. Make : Havells - Cat Part No Jetavalourfl200wled757modnbltg Or Equivalent In Makes As Mentioned At Makes List In Ps 35 Suply & Fixing In Replacement Of 300 Watt Led Flood Light Luminaire With Separate Driver Assemble Boxwith Secondary Optics Made In Pressure Die Cast Housing And Heat Sink In Aluminium Extrusion And Ip 66, With Suitable Mounting Structure As Per Site Requirement Ccomplete All As Specified And Directed.Make : Havellscat Part No Jetavalourfl300wled757modnbltg Or Equivalent In Makes As Mentioned At Makes List In Ps 36 Supply & Fix In Replacement Of 400 Watt Led Flood Light Luminaire With Separate Driver Assemble Boxwith Secondary Optics Made In Pressure Die Cast Housing And Heat Sink In Aluminium Extrusion And Ip 66, With Suitable Mounting Structure As Per Site Requirement Complete All As Specified And Directed.Make: Havells Cat Part No Jetavalourfl400wled757modnbltg Or Equivalent In Makes As Mentioned At Makes List In Ps 37 Supply And Fix In Replacement Of Integral Led Aviation Light Comprising Housing With Polycarbonate Enclosure, Aviation Light Is To Be Fixed On Highmast Light Frame Complete All As Specified And Directed.Make: Bajaj Cat Part No: Bgav302led Or Equivalent In Makes As Mentioned At Makes List In Ps 38 Supply And Fix In Replacement Of 1X18 Watt Ww ( 3000K ) Led Bollard Outdoor Gate Lightwith Polycarbonate Diffuser And Ip 65 Protection Incl Demolition Of Existing Pcc And Make Suitable Pcc For New Bollard As Per Site Requirement And Fixing Arrangements Complete All As Specified And Directed.Make : Luker Cat Part No: Lglrbge-27 Or Equivalent In Makes As Mentioned At Makes List In Ps 39 Supply And Fix In Replacement Of 1X10 Watt Ww ( 3000K ) Led Outdoor Gate Lightwith Polycarbonate Diffuser And Ip 65 Protection Incl Demolition Of Existing Pcc And Make Suitable Pcc For New Bollard As Per Site Requirement And Fixing Arrangements Acomplete All As Specified And Directed.Make Luker Cat Part No: Lglsmd Or Equivalent In Makes As Mentioned At Makes List In Ps 40 S&F In Replacement Of Led Rope Light Out Door 12 W 24V Ip 68 With Warm White Incl 2 Pin Power Supply Connector, Connector Pin, And End Cap As Per Site Requirement Fixing At Roof Of The Bldg With Suitable Pvc Saddles For Every One Mtr On Rope. Make : Luker Cat Part No Lso68 Or Equivalent In Makes As Mentioned At Makes List In Ps 41 S & F In Repairs Connector Suitable For Ledstrip Outdoor 12 W 24 V Ip 68 Fittings Complete All As Specified And Directed. 42 S&F In Repairs Connector Pin Suitable For Ledstrip Outdoor 12 W 24 V Ip 68 Fittings Complete All As Specified And Directed. 43 Supply And Fix In Replacement 10 Wattsturdy Ip 65 Led Bollard With Excellent Light Out Put Through Its Pmma Window Ensuring Maximum Illumination Aspect In Surrounding. Incl Demolition Of Existing Pcc And Make Suitable Pcc ( 1:2:4 ) Type B1 For New Bollard As Per Site Requirement And Fixing Arrangements Complete All As Specified And Directed.Make Havells Cat Part No Mountbl10wled830psymtopmma Or Equivalent In Makes As Mentioned At Makes List In Ps Note: Quoated Rate Shallincludes Provn Of Pcc Work To Bollard 44 Suply & Fixing In Replacement Of 60 Wled Stellar Led Post-Top Offering Combination Of Sturdy Design, Execllent Illumination And Aesthetics In One Go. Ip 66 And Ik 10 Rating Ensures It Stands Tall Amid Varid Environemtnal Conditions , Incl Suitable Arrangements For Pole 3.5 Mtr Decorative Pole Complete All As Specified And Directed.Make Havells Cat Part No Nebulapt60wled857psymtopc Or Equivalent In Makes As Mentioned At Makes List In Ps 45 Suply & Fixing In Replacement Of 40 Wled New Generation, Ip 65 Led Post-Top Family, Energy Saving, Environmental Friendly, Long Life Aesthetically Designed With Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire With High Power Leds As Light Source. Clear Cover Offers Bright Illumination For Different Applications , Incl Suitable Arrangements For Pole 3.5 Mtr Decorative Polecomplete All As Specified And Directed.Make Havells Cat Part No Rubypt40wled757psymtopc Or Equivalent In Luker / Cromopton / Philips / Halonix / Benlo / Bajaj Or Any Other Approved Makes 46 Supply And Fix In Replacement Integral 25 Watt Ledpost Top Lantern Black / Copper Dust Painted Cast Aluminium Spigot, Spun Aluminium Canopy With Clear Acrylic Cover And Accessorieson On Existing Gi Pipe Of Diameter Complete All As Specified And Directed. Make : Havells Cat Part No Coralpt25wled757psymtopc Or Equivalent In Makes As Mentioned At Makes List In Ps 47 M&L For Straight Through Joint ( Epoxy ) For16 Sqmm To 35 Sqmm 3.5 Core Pvc Insulated And Sheathed Aluminium Conductor Under Ground Cableincl Freud , Thimbles, Nut & Bolts, Washers Etc And Testing Afterjointing Complete All As Specified And Directed.Make: M-Seal / Raychem / Cabseal / Denson 48 S&F Pvc Insulated Multistranded Copper Conductor 3 Core 10 Sqmm For Connection Of Floodlighton Rooftopand Fixing With Suitable Size Clamp And Connecting With Suitable Size Copper Lugs Including Taking Down Of Exisitng Old U / S Conductor Complete All As Specified And Directed. 49 S&F Pvc Insulated Multistranded Copper Conductor 4 Core 10 Sqmm For Connection From Panel To High Mast Fitting, And Connecting With Suitable Copper Lugs Including Taking Down Of Exisitng Old U / S Conductor Complete All As Specified And Directed. 50 S & F In Replacement Busbar Panel Weather Proof Outdoor Type Single Door, Fabricated Out Of3.15 Mm Thick Crcasheet With Epoxy Powder Coating Of Ral-7035 ( Siemens Gray ) Shade With Matt Finishwith Seven Tank Pre Treatment Process.The Panel Shall Be Compartmentized Design Totally Enclosed, Dust And Vermin Proof, Conforming To Degree Of Protection Ip-55, Gaskets Between All Adjacent Units And Beneath All Covers Shall Be Provided To Render The Joints Dust Proof.All Doors And Covers Shall Be Provided With Cylindrical Panel Locks And Shall Be Fully Gasketed With Neoprene Rubber And Shall Be Lockable. The Panel Shall Be Provided With Aluminium Bus Bars, 300Mmx40mmx 5Mm ( Thickness ) Electrolytic Grade Of Adequate Rating.The Bus Bars And Interconnecting Links Shall Be Insulated With Heat Shrinkable Pvc Sleeve With 4. Ryb & Black Colour Coding And Fix Horizontally. The Bus Bars Shall Be Supported On Unbreakable, Non-Hygroscopic Smc Insulated Supports At Sufficiently Close Intervals To Prevent Busbars Sag And Shall Be Housed In A Dedicated Compartment. Including Incoming And Outgoing Cable Connection, Glands, Thimbles All Joints And Connection Shall Be Done With Galvanised Or Codmium Plated High Tensile Nuts, Bolts And Washers. The Panel Shall Be Provided With 04 Nos 25Mmx25mmx3mm Thick Angle Iron Supports Of Not Less Than Each 0.6 Mtr Height Duly Painted With Anti Corrosive Black Paint And Grouted On Wall And Suitable Fixing Arranement As Per Site Requirement. The Overall Size Of The Busbar Panel Shallbe 350Mmx200mmx 400Mm ( Lxbxh ) .Including Pcc 1:3:6 Complete All As Specified And Directed. 51 Supply, Install, Commission And Testing Cubical Type Lt Panel Board, Outdoor Type, Manufactured By A Cpri Approved Factory, Floor Mounted, Dust & Vermin Proof, Front And Rear Operated Doorwithnecessary Locking Arrangement Made Of 50 X 6Mm Ms Angle Iron Frame Work And Crca Sheetof 3.15Mm Thick Duly Painted With Two Coats Of Powder Coated Paint Of Approved Shade After Seven Tank Treatment Process Both Internally And Externally. The Panel Shall Be Suitable For 415 Volts, 50 Hz, 3 Phase 4 Wire System And Shall Be Complete With Suitable Capacity Aluminium Bus Bar ( 1.5 Times The Incoming Switch Gear Current Rating ) With Suitable Size Of Pvc Insulated Copper Conductor, Thimbles Glands Including Dismantling Of Exting U / S Panel Board Complete All As Specified And Directed With The Following Accessories : ( A ) Mccb 63 A 4 Pole 415 V 25 Ka - 01 No ( Incoming ) ( B ) Mcb 40A Sp Pole 10 Ka L&T - 04 Nos ( C ) Street Light Timer Digital Switch - 1 No ( D ) Power Contracts 32 Mnx 3 Pole - 1 No ( E ) Aluminium Bus Bar 4 Strip ( F ) Internal Wiring For Panel Incl Insulators, Sleeves Etc ( G ) Painting And Treatment As Per Cpri 52 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode 600X600x6.3Mm Thick, Burried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metres Below Normal Ground Level, Connected To Galvanised Iron Strip 32 X 6 Mm Of 15M Length By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No 3 In Ssr Part-I Connected To Earthing Test Point All As Specified Or Indicated Including Provision Of Earthing Lead Protection Pipe, Pcc Earth Pit With Cover, Excavation & Earth Work, Testing On Completion Etc Complete All As Specified And Directed 53 Supply & Fix Replacement Of Gi Tubing Light Grade 40 Mm Dia Isi Marked Appx 1 Mtr To 1.5 Mtr Long With Flat Iron Base For Mounting Of Flood Lightwith All Fittings Inclnut, Bolt, Washers Suitable Size And Also Make The Hole For Pole For Entry Of The2.5 Sqmm Pvc Conductor Complete All As Specified And Directed 54 S&F In Replacement Of Cylindrical Panel Locks Of Suitable Size Or As Per Sample Including Drilling, Cutting And Welding Etc In Panel Sheets Without Disturbing To Other Existing Fitments And Complete All As Specified And Directed 55 S&F In Repalcement Of Old Broken Cold Rolled Mild Steel Hinges Of Existing Busbar Etc Of Suitable Size Or As Per Sample Including Welding And Painting To Match With Existing Colour Of Panel Sheet Etc Complete All As Specified And Directed 56 Disconnecting Exisitng Incoming And Outgoing Cables From Existing Busbar After Taking Proper Shutdown And Excercising All Safety Precautions, Human Safety, Removing The Old Busbarpanel Complete With Its Accessories And Setting A Side At Safe Place And M&L In Replacement Of Crca Sheet Of Thickness 2Mm Thick With Epoxy Powder Coating Of Ral 7032 ( Smoke Grey ) Busbars Angle Iron Supports Etc Including All Cables Re-Terminated According To Existing System With Busbar Panel All As Specified And Directednote: ( A ) The Quoted Rate Shall Includes Preparation Of Existing Surface Of Busbar And Supporting Surface Angle Iron Of Busbar By Scraping Down, Peeled Off Old Paint, Cleaning Etc And Applying One Coat Of Smoke Grey Paint To Busbar Incluidng Clenaing Of Busbars From Inside By Blowing Compressed Air Etc Complete ( B ) Size And Design Of Item Shall Be Executed As Per Site Requirement And Also Approved By Engr-In-Charge

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 18-12-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
INR 23.99 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail