Tender For Renovation Of Core Lab Extension 401H ( Sh: Civil & Electrical Works ) ; 1 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With Thefollowing Sizes Of Frls Pvc Insulated, Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Reqired. 2 4 X 6 Sqmm. + 2 X 06 Sqmm Earth Wire 3 4 X 10 Sqmm. + 2 X 06 Sqmm Earth Wire 4 Supplying & Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable Inthe Existing Surface / Recessed Steel / Pvc Conduit As Reqd. 5 1 X 1.5 Sq.Mm.. 6 3 X 1.5 Sq.Mm.. 7 3 X 2.5 Sq. Mm 8 3 X 4 Sq.Mm.. 9 S & F Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In The Front I / C Painting Etc As Reqd. 10 250 Mm X 300 Mm X 100 Mm Deep 11 Supply, Fixing, Following Modular Type Switch / Socket On Existing Modular Plate & Switch Box Including Connectins But Excluding Modular Plate Etc. As Reqd. 12 5 / 6 Amp Switch 13 15 / 16 Amp. Switch 14 3 Pin 5 / 6 Amp. Socket Outlet 15 6 Pin 15 / 16 Amp. Socket Outlet. 16 Blanking Plate 17 S / F Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Reqd. 18 1 Or 2 Module 19 3 Module 20 4 Module 21 6 Module 22 8 Module 23 12 Module 24 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 Volts, C Series, Mcb Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Reqd. 25 Single Pole 26 Single Pole & Neutral 27 Triple Pole 28 Triple Pole & Neutral 29 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 30 Supplying And Fixing Tp Sheet Steel Enclosure On Surface / Recess Along With 16 / 25 / 32 A 415 V C Curve Tp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 31 P & F 6 Swg Dia Gi Wire On Surface Or In Recess For Loop Earthing Asreqd. 32 Supplying And Making Indoor End Termination With Brass Compression Gland, Aluminum Lugs For Following Size Of Pvc Insulated & Pvc Sheathed / Xlpe Aluminum Cable Of 1.1Kv Grade As Reqd. 33 3½ X 70 Sq. Mm ( 38Mm ) 34 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Of Virtical Three Phase Distribution Board With Provision For 4 Ploe Mccb Upto 160A As Incommer , Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mccbs ( Includung Up To With 160A Mccbs As Incomer ) Complete As Required And Instructed By Engineer In Charge. 35 8-Way ( Tmaxxt1+24 ) Double Door 36 Supplying And Fixing Following Size / Surface Mounting Plastic Boxas Required.Make Havells Or Equivalent Approved Make. 37 1 / 2 Module 38 3 Module 39 4 Module 40 6 Module 41 Providing And Fixing Dlp Plastic Trunking Of Size 105 Mm X 50 Mm Without Cover On Surface As Reqd. 42 Providing And Fixing 85 Mm Width Flexible Cover Of Dlp Plastic Trunking. ( Size 105 Mm X 50 Mm. ) 43 Supply And Fixing Of Following Items For Plastic Trunking Accessories Suitable For Size 105 Mm X 50 Mm. 44 End Cap 45 Internal Angle. 46 Flat Junction 47 Base Joint 48 Supplying, Installation Dlp Mini- Trunking 32Mm X 20Mm And Accessories White-System With Independent Cover- Without Central Partion Etc. As Reqd. 49 Mini- Trunking 50 End Cap Left Or Right 51 Internal / External Angle 52 Flat Angle 53 Flat Junction 54 S & Laying Of One No.Xlpe Cable Aluminum Conductor Steel Armoured Power Cable Of 1.1Kv Grade Of Size3-1 / 2X70 Sq.Mm. In Following Manners. 55 In Open Duct 56 On Surface With Ms Clamp 57 S&F, Copper Tube / Reducer / Lugterminals Suitable For Following Size Of Conductor. 58 10 Mm 59 16 Mm 60 35 Mm 61 Dismentaling And Refixing Of Light Fittings Of Any Sizess On Surfaceor In Recessed Etc As Reqd. 62 Dismantling & Refixing Of Any Size Fan With Fasner From Normal Height 63 Ceiling Fan 64 Supplying & Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable Inthe Existing Surface / Recessed Steel / Pvc Conduit As Reqd. 65 4 X 16 Sq.Mm.. 66 3 X 35 Sq.Mm.. 67 S & F 40 Amp To 63 Amp Rating 240 Volts C Curve 10 Ka Mcb Of Following Pole In The Existing Mcb Db Complete With Connection, Testing & Commissioning Etc As Reqd. 68 Single Pole 69 Double Pole 70 Triple Pole 71 Four Pole 72 Supplying And Fixing Of Clip-On Frame With Finishing Plate For 85Mm Cover For Dlp Plastic Trunking 105Mmx50mmetc As Required To Complete Of Approved Make ( Arteor Model Of Legrand Or Equivalent ) . 73 1 Or 2 Module 74 3 Module 75 6 Module 76 Supplying And Fixing Of Following Modular Switch / Sockets On The Existing Clip-On 85Mm Cover Of 105Mmx50mm Dlp Plastic Trunkingincluding Connection Etc As Required Complete Of Approved Make ( Arteor Model Of Legrand Or Equivalent ) . 77 6 Amp Switch 78 20 Amp. Switch 79 6 Amp. 2 / 3 Pin Socket Outlet 80 6 / 16 Amp. Threepin Two Module Socket Outlet. 81 S & F Metal Enclosure Suitable For Dp / Tpn / Fp Mcb / Dp Elcb On Surface Or Recessed Etc As Reqd. 82 Laying Utp Cable Enhanced Cat 5 / Cat 6 Cable In Existing Steel Conduit Pipe / Gi Pipe / Raceway / Rcc Pipe As Reqd. The Cost Shall Also Include Numbering Of Networking Wire From Room To Rack As Reqd. ( Wire Will Be Supplied By Dept ) 83 Fixing Of Rj-45 Modular Box With Cover Plate Or I / O Box For Interneton Surface / Recessed Cutting The Wall Making Good The Same As Required. ( Box And Cover Plate Will Be Supplied By Dept. ) 84 Reinforced Cement Concrete 85 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) . 86 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For 87 Shelves ( Cast In Situ ) 88 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. 89 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 90 Masonry Work 91 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. 92 Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 93 Cladding Work 94 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. 95 Raj Nagar Plain White Marble / Udaipur Green Marble / Zebra Black Marble 96 Area Of Slab Upto 0.50 Sqm 97 Extra For Providing Opening Of Required Size & Shape For Wash Basin / Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble / Granite / Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. 98 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 99 Wood And P. V. C. Work 100 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 101 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws 102 Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 103 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) , With Necessary Accessories And Screws Etc. Complete. 104 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 105 250X10 Mm 106 Providing And Fixing Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 107 125 Mm 108 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. 109 Twin Rubber Stopper 110 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock, Isi Marked, With Six Levers And A Pair Of Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Aluminium Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 111 Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board, Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed / Roll Form G.I. Sheet With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) , Consisting Of Floor And Ceiling Channel 50Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Ceiling At The Spacing Of 610 Mm Centre To Centre With Dash Fastener Of 12.5 Mm Dia Meter 50 Mm Length Or Suitable Anchor Fastener Or Metal Screws With Nylon Plugs And The Studs 48 Mm Wide Having One Flange Of 34 Mm And Other Flange 36 Mm And 0.50 Mm Thick Fixed Vertically Within Flanges Of Floor And Ceiling Channel And Placed At A Spacing Of 610 Mm Centre To Centre By 6 Mm Dia Bolts And Nuts, Including Fixing Of Studs Along Both Ends Of Partition Fixed Flush To Wall With Suitable Anchor Fastener Or Metal Screws With Nylon Plugs At Spacing Of 450 Mm Centre To Centre, And Fixing Of Boards To Both Side Of Frame Work By 25 Mm Long Dry Wall Screws On Studs, Floor And Ceiling Channels At The Spacing Of 300 Mm Centre To Centre. The Boards Are To Be Fixed To The Frame Work With Joints Staggered To Avoid Through Cracks, M.S. Fixing Channel Of 99 Mm Width ( 0.9 Mm Thick Having Two Flanges Of 9.5 Mm Each ) To Be Provided At The Horizontal Joints Of Two Boards, Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corners ( 25 Mm X 25 Mm X 0.5 Mm ) , Joint Finisher And Two Coats Of Primer Suitable For Board As Per ManufactureS Specification And Direction Of Engineer In Charge All Complete. 112 75 Mm Overall Thickness Partition With 12.5 Mm Thick Double Skin Fire Rated Glass Reinforced Gypsum ( Grg ) Plaster Board Conforming To Is: 2095: Part 3 ( Board With Bis Certification Marks ) 113 Providing And Fixing Sliding Arrangement In Racks / Cupboards / Cabinets Shutter By With Stainless Steel Rollers To Run Inside C Or E Aluminium Channel Section ( The Payment Of C Or E Channel Shall Be Made Separately ) 114 Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt / Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality. 115 1.0 Mm Thick 116 Providing And Fixing Plain Lining With Necessary Screws / Nuts & Bolts / Nails, Including A Coat Of Approved Primer On One Face, And Fixed On Wooden / Steel Frame Work, Complete As Per Direction Of Engineer-In- Charge ( Frame Work Shall Be Paid For Separately ) . 117 12Mm Thick Commercial Ply Conforming To Is : 1328 Bwr Type 118 Providing And Fixing Frame Work For Partitions / Wall Lining Etc. Made Of 50X50x1.6 Mm Hollow Ms Tube, Placed Along The Walls, Ceiling And Floor In A Grid Pattern With Spacing @ 60 Cm Centre To Centre Both Ways ( Vertically & Horizontally ) Or At Required Spacing Near Opening, With Necessary Welding At Junctions And Fixing The Frame To Wall / Ceiling / Floors With Steel Dash Fasteners Of 8 Mm Dia, 75 Mm Long Bolt, Including Making Provision For Opening For Doors, Windows, Electrical Conduits, Switch Boards Etc., Including Providing With Two Coats Of Approved Steel Primer Etc. Complete, All As Per Direction Of Engineer-In-Charge. 119 Steel Work 120 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 121 In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 122 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron ) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade ( Yield Strength 480 N / Mm2 ) , Counter Sunk Head, Comprising Of 10 Mm Dia Polyamide Pa 6 Grade Sleeve, Including Drilling Of Hole In Frame , Concrete / Masonry, Etc. As Per Direction Of Engineer-In-Charge. 123 10 X 60 Mm 124 Flooring 125 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqmincluding Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 126 Size Of Tile 600X600 Mm 127 Roofing 128 Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg / M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. 129 Finishing 130 6 Mm Cement Plaster Of Mix : 131 1:3 ( 1 Cement : 3 Fine Sand ) 132 Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per ManufacturerS Specification. 133 Two Or More Coats On New Work 134 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 135 Distempering With 1St Quality Acrylic Distember ( Ready Mix ) Having Voc Content Less Than 50 Grams / Litreof Approved Brand And Manufacture To Give An Even Shade : 136 Old Work ( One Or More Coats ) 137 Dismantling And Demolishing 138 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. 139 For Thickness Of Tiles 10 Mm To 25 Mm 140 Sanitary Installations 141 Providing And Fixing White Vitreous China Laboratory Sink Including Making All Connections Excluding Cost Of Fittings : 142 Size 600X450x200 Mm 143 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. 144 Semi Rigid Pipe 145 32 Mm Dia 146 Water Supply 147 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. Internal Work - Exposed On Wall 148 15 Mm Nominal Dia Pipes 149 20 Mm Nominal Dia Pipes 150 40 Mm Nominal Dia Pipes 151 Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : 152 25 To 40 Mm Nominal Bore 153 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) : 154 20 Mm Nominal Bore 155 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 156 15 Mm Nominal Bore 157 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 158 15Mm Nominal Bore 159 Aluminium Work 160 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fastenersto Be Paid For Separately ) : 161 For Fixed Portion 162 Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15 ) 163 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) 164 Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15 ) 165 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer- In-Charge. 166 Pre-Laminated Particle Board With Decorative Lamination On Both Sides 167 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : 168 With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 169 Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6 Levers Without Pair Of Handles ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete. 170 Minor Civil Maintenance Work: 171 Providing And Fixing Vertical Venition Blinds Vista Make Dustguard ( Classic / Select ) 100 Mm Wide On Windows.