Military Engineer Services-MES has published Tender For Repair And Maintenance Of Water Supply Lines Incl Main Pipe Line, Valves, Valve Chambers, Ro Plants, Hot Water Plants Lagging Etc At Jak Li Rc Under Ge 970 Ews. Submission Date for this Tender is 22-12-2023. Valve Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Dec-2023 | No-1 | BOQ | 15-12-2023 |
2 | 15-Dec-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-12-2023 |
Sl. No. | Item Description |
1 | Excavationintrenchesnotexc 1.5 M wideandnotexc1.5 Mindepthandgettingoutin any type ofsoil for taking out/laying of pipes complete allasspecifiedanddirected. |
2 | Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cm complete allasspecifiedanddirected. |
3 | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed. |
4 | Taking up or down old GI/PPR pipe of following sizes from excavated trenches including removing of fittings all as directed for necessary replacement/relaying of serviceable pipe complete all as specified and directed. |
5 | 100 mm bore |
6 | 80 mm bore |
7 | 50 mm bore |
8 | 40 mm bore |
9 | 25 mm bore |
10 | 20 mm bore |
11 | 15 mm bore |
12 | Relaying of serviceable pipe retrieved from item no 04 after removal of scaling, cleaning and flushing etc including supply and fixing of new fittings any grade in trenches and testing for following sizes complete all as specified and directed. |
13 | 100 mm bore |
14 | 80 mm bore |
15 | 50 mm bore |
16 | 40 mm bore |
17 | 25 mm bore |
18 | 20 mm bore |
19 | 15 mm bore |
20 | Refixing only serviceable GI pipe of following sizes in short lenth (less than 03 mtr) after removal of scaling, cleaning and flushing etc including supply and fixing of new fittings suitable grade, in wall, floor or in ceiling and testing for following sizes complete all as specified and directed. |
21 | 50 mm bore |
22 | 40 mm bore |
23 | 25 mm bore |
24 | 20 mm bore |
25 | 15 mm bore |
26 | Supply, fixing and testing of GI pipe of medium grade including all GI fittings (such as bend, tee, elbow, socket etc. ) laid in trenchesfor the following sizes complete all as specified and directed. |
27 | 100 mm bore |
28 | 80 mm bore |
29 | 50 mm bore |
30 | 40 mm bore |
31 | 25 mm bore |
32 | 20 mm bore |
33 | 15 mm bore |
34 | Repair/maint of water leakage from GI/PPR pipe joint in ground and open carefully the joint portion of the of the pipe line after excavated the trench or along the wall of multy story bldgs by providing necessary ladder and opening existing fittings for repair/replacement and provision of new GI/PPR fittings if required to make the joint 100% water leak proof including returning, filling and ramming the excavated materials or fixing with wall by clamps after satisfactory, joint/leak checking complete all as specified and directed for following bore of GI/PPR pipe line :- |
35 | 80 mm bore pipe line. |
36 | 50 mm bore pipe line. |
37 | 40 mm bore pipe line. |
38 | 25 mm bore pipe line. |
39 | 20 mm bore pipe line. |
40 | 15 mm bore pipe line. |
41 | Supply and fixing in replacement of PPR pipes 3- layer SDR 7.4 of outer diameter of pipes as following UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PPR plain & brass threaded polypropylene random fittings laid in trenches including fittings and testing complete all as specified and directed. (Note : Excavation, earthwork & fittings shall deemed to be include in quoted unit rate) |
42 | 20 mm dia. |
43 | 25 mm dia. |
44 | 32 mm dia. |
45 | 50 mm dia. |
46 | 63 mm dia. |
47 | 90 mm dia. |
48 | M&L for Construction of Brick Masonary valve chamber of size 600mmx600mmx600mm (Internal dimensions) with PCC 1:4:8 type D-2 foundation 150mm thick, brick work built in CM 1:6, PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal and exposed surfaces including excavation earthwork in any type of soil, MS sheet cover 3.15mm thick and MS equal angle iron 40mmx40mmx5mm frame as per existing sizewith locking arrangement embedded in PCC and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc including demolition of old/damaged valve pit complete all as specified and directed. |
49 | Description all as per item No. 10 here-in-before but of size 900 mm x 900 mm x 900mm (internal dimension) . |
50 | Making connection of PPR distribution branch with PPR main ofsizes 16 mm to 40 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
51 | Making connection of PPR distribution branch with PPR main ofsizes 50 mm to 75 mm by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
52 | Supply and fixing in replacement of gun metal gate valve of size 15mm dia including connection and testing complete all as specified and directed. |
53 | Supply and fixing in replacement of gun metal gate valve of size 20mm dia including connection and testing complete all as specified and directed. |
54 | Supply and fixing in replacement of gun metal gate valve of size 25mm dia including connection and testing complete all as specified and directed. |
55 | Supply and fixing in replacement of gun metal gate valve of size 40mm dia including connection and testing complete all as specified and directed. |
56 | Supply and fixing in replacement of gun metal globe or gate valve of size 50mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
57 | Supply and fixing in replacement of gun metal globe or gate valve of size 80mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
58 | Supply and fixing in replacement of PPR gate valve (brass insert) of size 20 mm dia including connection and testing complete all as specified and directed. |
59 | Supply and fixing in replacement ofPPR gate valve (brass insert) of size 25 mm dia including connection and testing complete all as specified and directed. |
60 | Supply and fixing in replacement of PPR gate valve (brass insert) of size 32 mm dia including connection and testing complete all as specified and directed. |
61 | Supply and fixing in replacement ofPPR gate valve (brass insert) of size 50 mm dia including connection and testing complete all as specified and directed. |
62 | Supply and fixing in replacement ofPPR gate valve (brass insert) of size 63 mm dia including connection and testing complete all as specified and directed. |
63 | Supply and fixing in replacement of bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
64 | Lagging on pipe of internal dia 15 mm, used in external water supply or plumbing all round with 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauge, 20mm mesh and finally covering with plaster of paris including taking down existing lagging, complete all as specified and directed. |
65 | Description all as per item No. 26but on 20 mm bore pipe -ditto- |
66 | Description all as per item No. 26but on 25 mm bore pipe -ditto- |
67 | Description all as per item No. 26but on 40mm bore pipe -ditto- |
68 | Description all as per item No. 26but using 40mm thick bonded mineral wool and on 50mm bore pipe -ditto- |
69 | Description all as per item No. 26but for 80mm bore GI/CI pipe with 40mm thick bonded mineral wool -ditto- |
70 | Description all as per item No. 26but for 100mm bore GI/CI pipe with 40mm thick bonded mineral wool -ditto- |
71 | Description all as per item No. 26but for 150mm bore GI/CI pipe with 40mm thick bonded mineral wool -ditto- |
72 | Taking up cast iron water main of size 80mmbore (including all fittings), with spigot and socket ends complete all as specified and directed. |
73 | Taking up cast iron water main of size 100mmbore (including all fittings), with spigot and socket ends complete all as specified and directed. |
74 | Taking up cast iron water main of size 150mmbore (including all fittings), with spigot and socket ends complete all as specified and directed. |
75 | M & L for replacement of joints for spigot and socket CI pipe with run lead joint for the following size of pipes:- |
76 | 80mm bore pipe line |
77 | 100mm bore pipe line |
78 | 150mm bore pipe line |
79 | CI fittings like bend (any type radius and angle), taper any type (straight, bends, increasing, decreasingor double socket etc) Tee pieces single branch "Y" junction, double branch cross (all socket or socket and spigot) collars caps and plugs etc upto size 200mm bore of pipe complete all as specified and directed. |
80 | Repair/maint of water leakage from CI/DI pipe joint in ground and open carefully the joint portion of the pipe line after excavated the trench and burn out the defective run lead joint in existing CI pipe/fitting and provision of new lead joint at site using the retrieved lead as obtaining from burning out of joint and adding of fresh lead if required to make the joint 100% water leak proof including returning, filling and ramming the excavated material after satisfactory, joint/leak checking complete all as specified and directed for the following bore of CI pipe line :- |
81 | 150 mm bore pipe line. |
82 | 100 mm bore pipe line. |
83 | 80 mm bore pipe line. |
84 | Supply and fixing in replacement of cast iron sluice valve (ISI marked) with both end flanged with iron wheel handle for clockwise closing brass spindle heavy duty PN-1.6 class. including gaskit joint nut, bolts & washers all as requirement of site complete all as specified and directed for the followingsize :- |
85 | 80 mm bore |
86 | 100 mm bore |
87 | 150 mm bore |
88 | Material and labour for replacement of brass spindle for sluice valve (ISI marked) matching with existing make complete with collar neck nuts and all as per existing type of sluice valves for the following size complete all as specified and directed |
89 | 150 mm bore pipe line. |
90 | 100 mm bore pipe line. |
91 | Relaying of serviceable CI water main pipe with spigot & socket ends retrieved from item No. 34 to 36 here-in before with joints and jointing material for the following size of pipes |
92 | 80 mm bore |
93 | 100 mm bore |
94 | 150 mm bore |
95 | Supplying and laying synthetic Rubber insulated matt 10 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, suitable for electrical shock safety of size 2m x 1m complete all as specified and directed |
96 | Supply and fixing in replacement of single phase preventor 25 KA, 415 V, complete all as specified and directed. |
97 | Supply only bleaching powder of superior quality with latest lot and test certificate from authorized laboratory with minimum 30% active chlorine (in 25 Kg bags) complete all as specified and directed. |
98 | Supply only granular chlorine (60% of chlorine conten) disinfectant superior quality for mixing with drinking water for water treatment, complete all as specified and directed. |
99 | Supply only allum, crystal type, superior quality for water treatment, complete all as specified and directed. |
100 | Collecting the water / sewage samples in the sterilised container from the different locations at JAK LI RC, GE 970 EWS in the sealed container in presence of concerned dept rep and transport to National / State Govt Authorised laboratory such as PHE/NTH or any Govt approved agenises and carrying out the Physical / Chemical / Biological analysis and submitting the details report as per standard parameters in duplicate to this office complete all as specified and directed. |
101 | M&L for mechanical joint forCI/DI pipe with clamp and rubber or fiber board gasket for the following sizes of pipe with necessary nut, bolts, washers etc including dismantling complete all as specified and directrd. |
102 | 80 mm bore |
103 | 100 mm bore |
104 | 150 mm bore |
105 | S&F in replacement of battery 12 V, 180 AH Make: Exide/Amron/ Tata |
106 | Supply ,laying, filling in layers of Pea Gravel as per IS 154097-1967 of assorted size M around annular space between the casing pipe and the well surface has to be filled with a gravel pack to act as filter medium in tube well spacing and the size of gravel will be 5 to 10mm, complete all as specified and directed . |