Tender For Addition /Alteration To Existing Jcos And Ors Accommodation At Kamlesh Vihar Dhar Road Udhampur., udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Addition /Alteration To Existing Jcos And Ors Accommodation At Kamlesh Vihar Dhar Road Udhampur.. Submission Date for this Tender is 06-01-2024. Septic Tank Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40784344
Corrigendum : Tender For Addition /Alteration To Existing Jcos And Ors Accommodation At Kamlesh Vihar Dhar Road Udhampur.
Open Tender
Indian
Jammu And Kashmir
udhampur
06-01-2024

Tender Details

Tender For Addition / Alteration To Existing Jcos And Ors Accommodation At Kamlesh Vihar Dhar Road Udhampur.; 1 Demolition Of Brick Work Built In Cement Mortar Including All Quions, Arches, Pillars Etc But Excluding Ashlarfacings Dressed Stone Work And Precast Concrete Articles Complete All As Specified And Directed. 2 Brick Work With Sub Class “B” Bricks ( Using Old Size Bricks ) Straight Or Curved On Plan Exc 6M Mean Radius Build In Cement Motar 1:6 Using All As Specified Complete All As Specified And Directed. 3 All As Per Item No 02 But Except Bricks Complete All As Specified And Directed. 4 Brick Work With Sub Class “B” Bricks ( Using Old Size Bricks ) Straight Or Curved On Plan To Any Radius In Half Brick Thick Wall, Built In Cement Mortar 1:4 Complete All As Specified & Directed. 5 Taking Down Cement Plaster On Brick Or Stone Wall Etc Including Racking Out Joints, Hacking For Key Scrubbing Down With Water Etc To Receive New Plaster Etc, Complete All As Specified And Directed. 6 Rendering 15Mm Thick Onfair Faces Of Brick Work Or Concrete Surfaces In Cement Motar 1:6 Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 7 Rendering 15Mm Thick On Surface Other Than Fair Faces Of Brick Work Or Concrete Surfaces In Cement Motar 1:4 Finished Using Water Proofing Compound As Per ManufactureS Instruction, ( Wpc To Bepaid Measured And Seperately As Supply Only ) Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 8 Supply Only Integral Water Proofing Compound Complete All As Specified And Directed. 9 Rendering 10 Mm Thick In Cm 1:3 Over Concrete Surface As On Ceiling, Chhajja, Shelves Etc To Match With Existing Surfaces Finish Even And Smooth W / O Using Extra Cement Complete All As Specified And Directed. 10 Preparing Newlyplasteredsurfaces Of Walls And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Primer Complete All As Specified And Directed. 11 Preparation Of New Plastered Surfaces Of Wall And Applying Three Coat Of White Washing, Complete All As Specified And Directed. 12 Preparation Of New Plastered Surfaces And Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm , Complete All As Specified And Directed. 13 Preparation Of New Plastered Surfaces Of Ceiling And Applying Three Coat Of White Washing, Complete All As Specified And Directed. 14 Complete Removal Ofexisting Treatmenton Wall And Applying Two Coats Of Oil Bound Distemper Over A Coat Ofprimer On Plasterd Surfaces Of Wall Complete All As Specified And Directed. 15 Preparation Of New Plastered Surfaces Of Wall And Applying 3Mm Thick Wall Care Putty In Two Coats And Smoothening The Surfaces With Sand Paper / Mechanised Sanding Complete All As Specified And Directed. 16 Complate Removal Of Existing Treatement And Preparation Of Surfaces And Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives @ 1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm , Complete All As Specified And Directed. 17 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc, Complete All As Specified And Directed. 18 Dismantling Floor Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. 19 Non Skid Colouredceramic Tiles ( Joint Free ) 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11Sqm, In Floor Jointed In Neat Cement Slurry And Pointed With Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Or Bedding In Cement Motar 1:4 In Floors Etc , Complete All As Specified And Directed . 20 Glazed Ceramic Tiles Jointless Light Coloured Of Size 300X600x7mm As In Vertical Surfaces Such As Skirting / Dado Etc., Set And Jointed In Neat Cement Slurry And Pointed With White Cement And Pigment To Match, Laid Over And Including 10Mm Thick Plastering In Cement Mortar 1:4., Complete All As Specified And Directed . 21 Non Skid Colouredceramic Tiles ( Joint Free ) 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.36 Sqm, In Floor Jointed In Neat Cement Slurry And Pointed With Coloured Cement To Match Over And Including 15Mm Thick Screed Bed Or Bedding In Cement Motar 1:4 In Floors Etc , Complete All As Specified And Directed . 22 Non Skid Colouredceramic Tiles ( Joint Free ) 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.18 Sqm But Not Exceeding 0.36 Sqm, As In Vertical Surfaces Such As Skirting / Dado Etc., Set And Jointed In Neat Cement Slurry And Pointed With White Cement And Pigment To Match, Laid Over And Including 10Mm Thick Plastering In Cement Mortar 1:4., Complete All As Specified And Directed . 23 Machine Cut Kota Stone Slab Flooring With White Boarder Lining 20Mm Thick As Per Sample Kept In Ge’S Office, Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of Slab, As Inin Skirting, Dados, Risers To Steps Etc, Laid Over And Including 10Mm Thick Rendering In Cement Mortar 1:4 , Cutting, Rubbing, Grinding And Polishing To Achieve Mirror Finish Complete, All As Specified. 24 20 Mm Thick Granite ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Window Cills, Cooking Platforms And Like In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Including Cutting And Mirror Finish Polishing Over And Including 20 Mm Thick Screed Bedding / Backing Layer In Cm 1:3Including Providing Nosing To Edges Of Slab And Drilling Of Hole For Gas Pipe Using Mechanical Method, Complete All As Specified And As Directed By Engineer-In-Charge.Note: Granite Stone Slab Shall Be In Single Piece. 25 Marble 18-20 Mm ( Green / Any Colour Shade Approved By Ge ) Thick Over Cement Screed Bed Laid On 15 Mm Thick Cm 1:6 Andjointed With White Cement Slurry Mixed With Pigment Ot Match The Shadeto Flooring / Window Cills / Steps, Riserincl Rubbing And Polishingincl Rounding To Edge Of Marble, Complete All As Specified And As Directed. 26 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Not Exc 1.50 Sqm Each And Removing From Site Complete All As Specified And Directed. 27 Taking Down Chowkats Or Frames With Shutters ( Without Taking Off Shutters From The Frames ) Exc 1.50 Sqm Eachand N Exc 4 Sqm And Removing From Site Complete All As Specified And Directed. 28 35 Mm Thick2nd Class Hard Wood ( Sal / Hollock ) Glazed & Skeleton Factory Made Shutters, Open Rebated And Prepared To Receive Glass, Gauze Etc ( Without Sash Bars ) , Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitered Beads For Securing Glass, Etc, Sizes Of Members Ofdoor Shutters As Specified In Ssr- 2009Part-I Section 8.24 ( A ) , Complete All As Specified And Directed. 29 30 Mm Thickflush Shutters, Solid Core Construction, With Particleboard Core And Plywood Face Panels, Both Sides Laminated With Decorative Face Veneer With Lipping / Frame To Match , Complete All As Specified And Directed. 30 Solid Pvc Door Frames Of Size 50Mm X47mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed. 31 Factory Made Solid Pvc Moulded Door Shutter 28Mm - 30Mmthick ( Stiles ) With Particle Board Core With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Prelam Pvc Sheet On The Front Face And 2Mm Thick Plain Colour Pvc Sheet On Back Face Complete All As Specified And Directed. 32 Door Eye Viewer, Viewing Angle 180 Degree, Mounting Diameter 14Mm, Total Size 4 X 2.5Cm ( Lxd ) With Good Quality Glass Eye Lens, Brass Chromium Plated Fixed In Position For Door Shutters , Complete All As Specified And Directed. 33 Door Seal Brush ( Aluminium Plate With Nylon Brush ) Of Required Length For Any Size Of Doors, Fixed With Stainless Steel Screw, Complete All As Specified And Directed.Make : Harrison Or Equivalent. 34 18Mm Thick Mdfboard For Kitchencabinet / Cup Board Shutter / Partation / Shelves Etc In Required Size At Site Made Out Of 18Mm Thick Mdfboard Both Side Decorative Lamination Pvc Sheet Complete All Required Etc.The Panels Shall Be Fabricated Using Adhesive And Secure As Required.All Edges Shall Be Covered With 2Mm Thick Edge Bonding Taps Or 90° Edge Bent Finish As Per Manufacturers Instructions. 35 Pressed Steel Frames Of Size 105Mmx60mm For Doors With One Or More Rebates Fabricated Out Of 1.25Mm Thick Mild Steel Sheets Including Necessary Fixing Lugs, Butt Hinges ( 100Mm Medium Weight-03 Nos ) , Lock Strike Plate With And Including Filling Of Hollow Portion In Pcc 1:3:6 Type C1 Using 20Mm Graded Crushed Stone Aggregate And Making Good The Existing Surface In Cement Mortar 1:6., Complete All As Specified And Directed. 36 Pressed Steel Frames Of Size 125Mmx60mm For Doors With One Or More Rebates Fabricated Out Of 1.25Mm Thick Mild Steel Sheets Including Necessary Fixing Lugs, Butt Hinges ( 100Mm Medium Weight-03 Nos ) , Lock Strike Plate With And Including Filling Of Hollow Portion In Pcc 1:3:6 Type C1 Using 20Mm Graded Crushed Stone Aggregate And Making Good The Existing Surface In Cement Mortar 1:6, Complete All As Specified And Directed. 37 Pressed Steel Frames Of Size 75Mmx60mm For Cupboard Frames With One Or More Rebates Fabricated Out Of 1.25Mm Thick Mild Steel Sheets With And Including Necessary Fixing Lugs, Continuous ( Piano ) Hinges Mild Steel Bright Finished Or Electrogalvanised Width Of Flaps ( When Open ) 30Mm And Fixed With Chowkhat By Rebated And Welded, Lock Strike Plate With And Including Filling Of Hollow Portion In Pcc 1:3:6 Type C1 Using 20Mm Graded Crushed Stone Aggregate And Making Good The Existing Surfacein Cement Mortar 1:6, Complete All As Specified And Directed. 38 Powder Coated Aluminium Windows / Ventilator Complete All As Specified And As Shown On Drawing Ceuz / Td-1564 / 2016 Sheet No. 1 / 2 To 2 / 2 For Various Sizes And Pattern With Following Powder Coated Aluminium Sections :-Notes :-A. The Rates Quoted For Powder Coated Aluminium Sections Shall Be Deemed To Include The Following:- ( I ) Rubber Gasket For Fixing Glass To Window / Vent Shutters. ( Ii ) Fixing Of Window With And Including Min 75X10 Gi Screws All Around @ 300 C / C ( Min 2 Nos On One Side ) With Pvc Rawl Plugs / Sleeves. ( Iii ) Rollers, Concealed Lock Cum Handle & Othe Fittings For Sliding Shutters Shall Be Provided As Per Manufactures Instructions And Approved By Ge. ( Iv ) Silicone Sealant Shall Be Applied On Internal As Well As External Periphery Of Window And Masonry Joint To Avoid Water Seepage. ( V ) All Other Sundries All As Per Manufacturer Instructions And As Directed. B. The Rates Quoted For Powder Coated Sections Shall Exclude The Cost Following And Shall Be Paid Seerately Under Respective Items Of Sch A / Boq:- ( I ) Glass And Wire Mesh ( Ii ) 40X40x3 Aluminium Angle Provided On All Corners Of The Windows. ( C ) Aluminum -U-Channel Shall Be Provided For Fixing Of Wire Mesh. ( D ) Powder Coated Aluminum Handles And Hinges For Fixing Of Openable Shutters C. Other ( I ) No Allownace For Wastage / Overlaps Shall Be Considered For Payment. ( Ii ) Range Of Dimension Of Opening Size Has Been Mentioned. The Same Shall Be Fixed As Per Measurements Of Opening Of Windows As Per Site Requirement By The Ge During Execution Of Work. ( Iii ) Powder Coated Aluminuim Section Shall Be Provided All As Shown On Drawings And As Directed. 39 Three Track Powder Coated Aluminium Section As In Window / Vents Frame For Sliding Shutters, Complete All As Shown On Drawings And As Directed. 40 Powder Coated Aluminium Sections As In Window / Vents Frame For Openable Shutters , Complete All As Shown On Drawings And As Directed. 41 Powder Coated Aluminium Sections As In Sliding Window Shutters, Complete All As Specified And As Directed. 42 Powder Coated Aluminium Sections As In Openable Window Shutter , Complete All As Specified And As Directed. 43 Powder Coated Aluminium Tower Bolts 75Mm Long, Complete All As Specified And As Directed. 44 Powder Coated Aluminium Butt Higes 75Mm, Complete All As Specified And As Directed. 45 Powder Coated Aluminium Handle 75Mm, Complete All As Specified And As Directed. 46 Powder Coated Aluminium Plate Type Ii Gate And Shutter, Hook And Eyes 100Mm And Fixed , Complete All As Specified And As Directed. 47 Sheet Glass 4.8 Mm Thick Ordinary Quality And Glazing With Oil Putty In Squares N.Exc 0.5 Sqm Each Pane Complete All As Specified And Directed. 48 5Mm Thick, Frosted Glasspin Head Type And Glazing With Oil Putty In Squares N.Exc 0.5 Sqm Each Pane Complete All As Specified And Directed. 49 Galvanised Mild Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm Dia And Fixed With Tinned Tacks Or Galvanised Mild Steel Staples Complete All As Specified And Directed. 50 30 Mm Continuous ( Piano ) Hinges, Mild Steel, Bright Finish Or Electro Galvanised , Complete All As Specified And Directed. 51 Magnetic Catcher Suitable For Kitchen Cabinet Shutters , Complete All As Specified And Directed.. 52 Hasp And Staple Alumniumanodised Lncluding Bolt To Hinges Plate 100Mm Sizewith Mild Steel Hinge Pin Including Bolt To Hinge Plate And Fixed With Screws. Complete All As Specified And Directed. 53 Aluminium Anodized 150Mm Long Barrel Tower Bolt Of Extruded Section And Fixed Complete All As Specified And Directed. 54 250Mm Long Aluminium Alloy, Anodized Sliding Door Bolt With Hasp Stapple ( Bolt Type ) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminium Alloy And Fixed Complete All As Specified And Directed. 55 Aluminium Handles Cast Type Anodizedof Size 150 Mm Complete All As Specified And Directed. 56 Preparing New Wooden Surfaces And Applying Two Coat Of Synthetic Enamel Paint Over A Coat Of Pink Primer On Wooden Surfaces Of Any Description, Not Otherwise Described Over 10 Cm Width Or Girth, Complete All As Specified And Directed. 57 Preparing New Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint On Steel Surfaces Over A Coat To Red Oxide / Zinc Oxide Primer Any Description, Not Otherwise Described Over 10 Cm Width Or Girth Complete All As Specified And Directed. 58 Preparing Of Old Steel Surfaces And Applying One Coats Of Synthetic Enamel Paint On Steel Surfaces , Not Otherwise Described Over 10 Cm Width Or Girth Complete All As Specified And Directed. 59 Viterous China Squating Pan Of ( Orrissa Pattern ) Size 580X440 Mm White With P Or S Trap Front Or Back Inlet And Integral Foot Rest ( Excluding Flushing Cisteern And Flush Pipe ) , Fixed In Repair Including Lime Concrete Bedding As Required Complete All As Specified And Directed. 60 Pvc Valveless, With Top Button Double Action Type, Syphonic Action Type Flushing Cistern, 10 Litres Capacity, Low Level, White With Inlet, Ball Valve, Float And Handle, 32 Mm Dia Pvc Long Bend Flush Pipe, Fixed In Repairs Complete All As Specified And Directed. 61 Vitreous China Wash Basin, White, Flat Back, Size 550 X 400 Mm Excluding Taps, Waste Chain And Plug And Porcelain Stopper But Including Brackets Complete All As Specified And Directed. 62 Mirror Cabinet Ptmt Of 400Mm X 500 Mmwith Magnetic Looking Arrangements Fixed With And Inclduling Wooden Plugs With Chromium Plated Brass Screws, Complete All As Specified And Directed 63 Bevelled Edge Mirror, Size 600X 450 Mm Of Selected Qualityglass, Mounted On 6 Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Complete All As Specified And Directed. 64 Brass Chromium Plated Tubular Towel Rail 20 Mm Dia, D Type, 60 Cms Long Between Flanges With And Including Chromium Plated Brass Brackets, Brass Screws , Complete All As Specified And Directed. 65 Towel Ring Brass Chromium Plated, Fixed With Brass Screws And Plugs , Complete All As Specified And Directed. 66 Chromium Plated Soap Dish, Fixed To Plugs With Chromium Platwd Brass Screws Complete All As Specified. 67 Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12 Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long , Complete All As Specified And Directed. 68 Bib Tap Chromium Plated Fancy Type Long Body 15 Mm Bore, Screwed Down Screwed To Iron Pipe, Fixed In Repair, Complete All As Specified And Directed. 69 Stop Cock / Angle Chromium Plated Fancy Type Long Body 15 Mm Bore, Screwed Down Screwed To Iron Pipe, Fixed In Repair , Complete All As Specified And Directed. 70 Wall Mixer With Provision For Overhead Shower With 115 Mm Long Bend Pipe On Upper Side, Connecting Legs And Wall Flanges. Make: Ess Cat Part No Ec-10 Or Equivalent. 71 Brass Centre Hole Mixer Chromium Plated Without Pop Up Waste System 15Mm Bore For Mixing Hot And Cold Water Screwed Down For Iron Pipe For Whb, Complete All As Specified And Directed. 72 Sink Mixer With Regular Spout Wall Mountatedwith Connectings Legs & Wall Flanges And Including All Necessary Fittings , Complete All As Specified And Directed. 73 Sinks With Drainage Boardmade Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar On To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe, Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Incl 32Mm Waste Fittings Brass Chromium Plated Etc Fixed In Repair, Complete All As Specified And Directed. 74 Stainless Steel Plate Racks Of Size 775Mm X 900 X 250Mm And Thickness Of Ss Strip Of 1Mm Fixed On Wall Etc , Complete All As Specified And Directed. 75 Shower Rose Brass Chrominium Plated 125Mm With Arm And Without Swivel Joints To Steel Pipe Size, Fixed In Repair, Complete All As Specified And Directed. 76 Pvc Connections 15 Mm Size Of Superior Quality With Ptmt Nuts Both Sideof Length 600Mm Fixed In Repair Complete All As Specified And Directed. 77 Rotational Moulded Polyethylene Water Storage Tank 500 Ltrs Capacity ( Isi Marked ) Cylinderical Vertical With Closed Top, Hoisted And Fixed In Position With Ball Brass Valve, High Pressure With 20 Mm Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe And Fixed. ( Minimum Weight 20Mm - 210 Gms ) Complete And Making Connections With Existing Water Supply Line, Fixed In Repairincluding Dismantaling Of Existing Water Tank, Complete All As Specified And Directed. 78 Disconnecting Existing Tanks Capacity 500Ltr, Setting Aside ( Or Lowering If Required ) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position And Cleaning And Removing All Scale And Dirt, Etc, From Tanks And From Mouths Of Circulating Pipes, Including 20 Mm Dia Float Valve , Complete All As Specified And Directed.. 79 Rotational Moulded Polyethylene Water Storage Tank 1000 Ltrs Capacity ( Isi Marked ) Cylinderical Vertical With Closed Top, Hoisted And Fixed In Position With Ball Brass Valve, High Pressure With 20 Mm Ball Valves High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball Screwed For Iron Pipe And Fixed. ( Minimum Weight 20Mm - 210 Gms ) Complete And Making Connections With Existing Water Supply Line Fixed In Repair Including Dismantaling Of Existing Water Tank, Complete All As Specified And Directed. 80 Disconnecting Existing Tanks Capacity 1000Ltr, Setting Aside ( Or Lowering If Required ) For Repairs, Cleaning, Etc. And Hoisting If Required Reconnecting And Re-Fixing In Position And Cleaning And Removing All Scale And Dirt, Etc, From Tanks And From Mouths Of Circulating Pipes, Including 20 Mm Dia Float Valve , Complete All As Specified And Directed. 81 Peg Set Of Six, Stainless Steel Of Suitable Length, Complete All As Specified And Directed. 82 Curtain Rod 25 Mm Dia Decorative / Fancy Type Stainless Steel With With Brackets And Knobs At Both Ends As Per Site Requirement Incl Taking Down Old Existing Pipes With Accessories Complete All As Directed. 83 Taking Down Steel Tubing And Connection Of 15Mm Bore Of Pipe , Complete All As Specified And Directed. 84 15Mm Bore Gi Tubingmedium Grade With All Fittings And Fixed Complete To Wall And Ceiling Or Laid In Floors Etc Including Cutting Chases In Brick Wall Pinning In Making Good In Cm 1:3 To Facings Where Required, Incl 10Cm Exc But Not Exc 20Cm In Girth. 85 15Mm Bore Gi Tubing ( Medium Grade ) With All Fittings And Fixed Complete Fixed Complete To Walls And Ceiling Or Laid In Floors / Roofs, Complete All As Specified And Directed. 86 Re-Fixing Old Steel Tubing And Connection 15 Mm Dia Bore To Wall And Laid In Floors , Complete All As Specified And Directed. 87 Taking Down Steel Tubing And Connection Of 20Mm Bore Of Pipe , Complete All As Specified And Directed. 88 20Mm Bore Gi Tubing ( Medium Grade ) With All Fittings And Fixed Complete Fixed Complete To Walls And Ceiling Or Laid In Floors / Roofs, Complete All As Specified And Directed. 89 Re-Fixing Old Steel Tubing And Connection 20Mm Dia Bore To Wall And Laid In Floors , Complete All As Specified And Directed. 90 Taking Down Steel Tubing And Connection Of 25Mm Bore Of Pipe , Complete All As Specified And Directed. 91 25Mm Bore Gi Tubing ( Medium Grade ) With All Fittings And Fixed Complete Fixed Complete To Walls And Ceiling Or Laid In Floors / Roofs, Complete All As Specified And Directed. 92 Re-Fixing Old Steel Tubing And Connection 25Mm Dia Bore To Wall And Laid In Floors , Complete All As Specified And Directed. 93 Taking Down Unservicable Gun Metal Globe Orgate Valve 20Mm Or 25Mm Dia Bore , Complete All As Specified And Directed. 94 Gun Metal Globe Orgate Valve With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixedbore Dia Of Pipe 20 Mm Complete All As Specified And Directed. 95 Gun Metal Globe Orgate Valve With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixedbore Dia Of Pipe 25 Mm , Complete All As Specified And Directed. 96 110Mm Bore Pvc Pipes Single Socketed Pressure Rating @4Kg / Sq Cm With Rubber Ring Joint, Fixed To Walls With Dash Ture Nut And Ms Ring ( 25X6 Fi Used ) Bolt At Every 1.5 Mtrs Length Complete, Including Taking Out Old Pipe With All Fittings , Complete All As Specified And Directed. 97 110Mm Bore Pvc Pipes Single Socketed Pressure Rating @4Kg / Sq Cm With Rubber Ring Joint, Laid In Treanch Or In Floor With Dash Ture Nut And Ms Ring ( 25X6 Fi Used ) Bolt At Every 1.5 Mtrs Length Complete, Including Taking Out Old Pipe With All Fittings, Complete All As Specified And Directed. 98 75Mm Bore Pvc Pipes Single Socketed Pressure Rating @4Kg / Sq Cm With Rubber Ring Joint, Fixed To Walls With Dash Ture Nut And Ms Ring ( 25X6 Fi Used ) Bolt At Every 1.5 Mtrs Length Complete, Including Taking Out Old Pipe With All Fittings, Complete All As Specified And Directed. 99 75Mm Bore Pvc Pipes Single Socketed Pressure Rating @4Kg / Sq Cm With Rubber Ring Joint, Laid In Treanch Or In Floor With Dash Ture Nut And Ms Ring ( 25X6 Fi Used ) Bolt At Every 1.5 Mtrs Length Complete, Including Taking Up / Down Out Old Pipe With All Fittings , Complete All As Specified And Directed. 100 Pvc ( Swr ) Bends / Junction ( Any Radius ) For 110Mm Bore Complete All As Specified And Directed. 101 Pvc ( Swr ) Bends / Junctionwith Access Door ( Any Radius ) For 110Mm Bore Complete All As Specified And Directed. 102 Pvc ( Swr ) Bends / Junctionwith Access Door ( Any Radius ) For 75Mm Bore Complete All As Specified And Directed. 103 Pvc ( Swr ) Branch Pieces Single ( Single Y ) Equal Or Unequal For 110Mm Bore , Complete All As Specified And Directed. 104 Pvc ( Swr ) Floor Trap With Grating Including Jointing To Waste Pipe In Solvent For 75Mm Bore Including Cp Grating Cover With Or Without Hole Complete All As Specified And Directed. 105 Pvc ( Swr ) Multi Floor Trap With Grating Including Jointing To Waste Pipe In Solvent For 75Mm Bore Including Cp Grating Cover With Or Without Hole, Complete All As Specified And Directed. 106 Taking Down Existing Roof Treatmentof Any Description And Any Type And Position And Removing The Deberis From Site Outside Md Land , Complete All As Specified And Directed. 107 Rendering 15Mm Thick In Cm 1:4 On Fair Faces Of Brick Work Or Concrete Surface Including Brushing Neat Cement Slurry With 3Kg Of Cement Per Sqm Finish Ever And Smooth ( W / O Using Extra Cement ) Including Wpc As Per Manufacture Instruction At Any Height Etc. ( Wpc Will Be Measured And Paid Separately As Supply Only ) , Complete All As Specified And Directed. 108 Roof Treatment For Non Accessible Roof :- Priming The Roof Surface With Bituminous Primer Conforming To Is-3384 @ 0.30 Ltrs / Sqm And Applying A Coat Of Hot Blown 85 / 25 Grade Bitumen Conforming To Is-702 @ 1.20 Kg / Sqm And Thereafter Provide Polymeric Water Proofing Membrane ( Five Layered ) Of Weight Not Less Than 3 Kg / Sqm With Centre Layer Core Of 90 Micron High Molecular Density Polyethylene Film Followed By Another Coat Of Semi Hot Blown 85 / 25 Grade Bitumen @ 1.20 Kg / Sqm Blinded With Fine Sand In Dry Condition @ 0.50 Kg / Sqm, Top Surface Of Roof After Carrying Out Treatment Shall Be Provided With Two Coats Of Aluminium Paint Over A Coat Of Primer Complete All As Specified And Directed. 109 Chicken Wire Mesh Of Size 12.5 Mm And Wire Dia 0.51 Mm ( 24 Swg ) Hexagonal Construction, Stretched Firmly For Roof Treatment , Complete All As Specified And Directed. 110 Pcc 1:2:4 Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) , 40Mm Thick, As In Padding Finished Even And Smooth Witout Using Extra Cement , Complete All As Specified And Directed. 111 Taking Down Old Pcc Tiles From Roof And Removing Bedding At Any Position And Removing The Deberis Outside The Md Land , Complete All As Specified And Directed. 112 Roof Tretment For Accessible Roof :- Priming The Roof Surface With Bituminous Primer Conforming To Is-3384 @ 0.30 Ltrs / Sqm And Applying A Coat Of Hot Blown 85 / 25 Grade Bitumen Conforming To Is-702 @ 1.20 Kg / Sqm And Thereafter Provide Polymeric Water Proofing Membrane ( Five Layered ) Of Weight Not Less Than 3 Kg / Sqm With Centre Layer Core Of 90 Micron High Molecular Density Polyethylene Film Followed By Another Coat Of Semi Hot Blown 85 / 25 Grade Bitumen @ 1.20 Kg / Sqm Blinded With Fine Sand In Dry Condition @ 0.50 Kg / Sqm , Complete All As Specified And Directed. 113 Cement Concrete Tiles, Coloured, Machine Pressed, Factory Made Of Size 20Cmx20cm, 20Mm Thick, With Grey Cement And Pigment, Set, Jointed And Pointed In Neat Cement Slurry, Laid Over And Including 15Mm Thick Screed Layer In Cm 1:4 Over Roofs, Complete All As Specified And Directed. 114 Pcc 1:2:4 Type B-0 ( Using 12.5Mm Graded Crushed Stone Aggregate ) , Wpc Along Side Wall Adjoining To Roof In Concave Shape , Complete All As Specified And Directed. 115 Water Proofing Treatment To Floor & Vertical Surfaces Of Sunken Portion Complete Comprising The Following: - ( A ) After Demolition Of Floor & Lime Concrete Etc. Remove All Loose Particles Along With Existing Water Proofing Treatment ( Any No. Of Layers ) With Wire Brushes And Cleaning The Surfaces With Water. ( B ) Brushing Cement Slurry With 1.2 Kg Of Cement Per Square Metre Duly Blended With & Including Water Proofing Compound. ( C ) 15 Mm Thick ( Average Thickness ) Plaster In Cement Mortar ( 1:3 ) Mixed With Wp Compound On Sunken Surface Including Walls. The Corner Of Sunken Portion Shall Be Rounded In Concave Shape And Adequate Slope Shall Be Made During Plastering To Accommodate Sump Pipe And Curing The Sunken Portion With Water Minimum For 48 Hrs By Ponding. ( D ) Applying Self Adhesive Type App Based Polymeric Membrane Minimum Weighing Not Less Than 3.6 Kg / Sq. M And Minimum 3 Mm Thick Reinforced With Polyester Non-Woven Fabric ( Weight Not Less Than 150 Gm / Sq. M ) , ( E ) M&L Forpcc 1:7 :12 For Filling Of Sunken Portion After Conceling All Menbrane And Sealing All Joints To The Entire With Broken Bats And Light Weight, Complete All As Specified And Directed. 116 Expanded Metal, Cut To Length, Bent To Shape Required And Tying With And Including Annealed Mild Steel Wire Not Less Than 0.9Mm Dia Or Fixed With Galvanized Steel Staples Supplied And Fixed Completeto Wood Or Steel Member, Weight Exc 4 Kg Per Sqm , Complete All As Specified And Directed. 117 Framed Work Rolled Section As In Framing Compound Girder Staging For End Bars, Shouldered And Riveted, Forged Into Spikes, Framed Guard Bars, Dooriron, Ladders Walk Rails, Railings, Frame Work For Tanks, Water Tank, Cooler Frameas And The Like Built Up From Two Or More Beam Or Channel Section Or Angles With Plates Stiffeners Etc Conforming To Fe-290Grade E-165 , Complete All As Specified And Directed. 118 Framed Work As In Safety Doors Fabricated Out Of Mild Steel Hollow Sections Of Sheet Thickness Not Less Than 1.6Mm Thick, Ms Square Bars Or Other Section With, Rails, Braces, Sliding Door Bolt Fabricated Out Of 16Mm Ms Round Bar, Staple Etc With And Including Provn For Fixing Of Wire Mesh, Complete And Fixed To Mild Steel Pressed Chowkhats. Note: ( Ii ) Sketch Drawing For Safety Door Shall Be Provided By The Ge During Execution Of Work. ( Ii ) Wire Mesh Shall Be Measured And Paid For Seperately 119 Demolition Of Reinforced Cement Concrete Of Any Description And Any Position Not Other Wise Specifically Provided, Complete All As Specified And Directed. 120 Rcc 1:2:4 Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like, Complete All As Specified And Directed. 121 Rcc 1:2:4 Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) As In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span , Complete All As Specified And Directed. 122 Use & Waste Of Form Work To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs Landings And Similar Work, Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) For Rough Finished Surfaces Of Concrete, Complete All As Specified & Directed. 123 Use & Waste Of Form Work To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs Landings And Similar Work, Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) For Rough Finished Surfaces Of Concrete, Complete All As Specified & Directed. 124 Hard Core Of Broken Stone Or Boulders Of Gauge Not Exc 63 Mm Deposited , Spread And Leveled In Layer Not Exc 15 Cm Thick Complete All As Specified And Directed. 125 Pcc 1:3:6 ( Nominal Mix ) Type C-1 ( Using 20Mm Graded Crushed Stone Aggregates ) As In Hold Fastcomplete All As Specified And Directed. 126 Brick Work With Sub Class “B” Bricks ( Using Old Size Bricks ) Straight Or Curved On Plan Exc 6M Mean Radius Build In Cement Motar 1:6 Using All As Specified Complete All As Specified And Directed. 127 Rcc 1:2:4 Type B-0 ( Using 12.5Mm Graded Crushed Stone Aggregate ) As Incoping / Benching And All Other Similar Works Including Necessary Formwork, Complete All As Specified And Directed. 128 Rcc 1:2:4 Type B-1 ( Using 20Mm Graded Crushed Stone Aggregate ) As In Surface Channel & Drain, Complete All As Specified And Directed. 129 Extra For Forming Fair Finished Drain Or Channel 30 Cm Inner Girth Of Cement Concrete Using Extra Cement Including Forms Moulds, Mitred / Stopped Endsetc, Complete All As Specified And Directed. 130 Providing Precast Cement Concrete ( 1:2:4 ) Type B-1 Using 20Mm Graded Crushed Stone Aggregate As In Cover Slaband Similar Articles Including Necessary Moulds / Formwork Set In Cement Mortar ( 1:6 ) Complete All As Specified And Directed. 131 Tmt Steel Bars 10Mm Dia And Over As In Reinforcement For Concrete, Cut To Length, Bent To Shape Requuired, Including Cranking, Bending Spirally For Hooping For Columns, Hooping Endand Binding With Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia, Complete All As Specified 132 Tmt Steel Bars 6 To 8Mm Dia As In Reinforcement For Concrete, Cut To Length, Bent To Shape Requuired, Including Cranking, Bending Spirally For Hooping For Columns, Hooping Endand Binding With Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia, Complete All As Specified 133 All As Per Srl Item No 124 Above But5mm Dia And Over Upto And Including 10Mm In Stirrups, Spacers And Binders Complete All As Specified 134 Demolition Of Cement Concrete ( Unreinforced ) Of Any Description And Any Position Not Other Wise Specifically Provided, Complete All As Specified And Directed. 135 40Mm Thick Pcc 1:2:4 C-2 ( Using 20Mm Graded Crushed Stone Aggregate ) As In Plinth Protection / Path / Any Paved Area Finishing Cement Concrete Surface Even And Smooth Complete All As Specified And Directed. 136 25Mm Thick, Pcc 1:2:4, Type B-0 ( Using 12.5Mm Graded Crushed Stone Aggregates ) As In Floor Finish, Surface Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 137 Providing Anti Termite Treatment Post Construction Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron, Complete All As Specified And Directed. 138 Anti Termite Treatment Postconstruction Of Soil Under Existing Floors Using Emulsion @ One Litre Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 ( 1 Cement: 2 Coarse Sand ) To Match The Existing Floors, Complete All As Specified And Directed. 139 Excavation In Trenches, Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exceeding 10 Sqm On Plan And Not Exceeding 1.5 Mtr In Depth And Getting Out In Any Type Ofsoil, Complete All As Specified And Directed. 140 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm, Complete All As Specified And Directed. 141 Removing Excavated Materials / Soils, Not Exceeding 50Mtrs And Depositing Where Directed At A Level Not Exceeding 1.50Mtrs, Complete All As Specified And Directed. 142 Reinforced Concrete Pipe, 450Mm Dia Class Np3, Laid And Jointed, Complete All As Specified And Directed. 143 Reinforced Concrete Pipes, Class Np3, Laid In Trenches, Jointing And Testing And Jointed, Complete With Collarsdrain Pipe, 150Mm Bore Conforming To Is At Any Depth After They Are Laid And Tested. Including Demolition And Breaking Up Old Drain Pipes ( Salt Glazed Ware, Ac Or Reinforced Concrete ) Set In Cement Mortar, Complete All As Specified And Directed. 144 Concrete Bed To Drain Pipes Laid To Falls Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested In Cement Concrete 1:3:6 Type C-2 ( Using 40Mm Graded Crushed Stone Aggregate ) For 150Mm Bore Pipe Complete All As Specified And Directed. 145 Construction Of Septic Tank For 100 Users ( Brick Constructions ) Complete All As Specified And As Shown On Drawing No. Ceuz / Td / 1585 / 21 Sheet No. 1 / 4 Toto 4 / 4 146 Construction Of Soakage Well 1.80M Dia And 4.50M Deep ( Internal Dimensions ) ( Brick Construction ) , Complete All As Specified And As Shown On Drawing No.Ceuz / Td / 1585 / 21 Sheet No. 1 / 4 Toto 4 / 4 147 Cement Concretetype D2 1:4:8 ( 40Mm Graded Crushed Stone Aggregate ) , 75Mm Thick As In Sub Base Complete All As Specified And Directed. 148 Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness, M-35 Grade With Grey Cement And Pigment Laid Over And Including 25Mm Thick Sand Cushioning, Joints Of Tiles Filled With Dry Sand And Compacted With Mechanical Vibrator , Complete All As Specified And Directed. 149 Factory Made Pre-Cast Cement Concrete Block Type B1, 1:2:4 As In Kerb Stone Made To Shape As Directed, Exc. 10 Cm In Width And Setting In Mortar 1:4 Including Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm ) , Including Making Drainage Opening Wherever Required, Complete All As Specified And Directed. 150 Taking Down Carefully Copper / Aluminium, Point Wiring ( Light, Fan, Socket Or Power ) Complete Including Fittings And Fixtures Such As Light Fittings, Switches, Ceiling Roses, Pendants, Regulators, Sockets Etc. And Making Good Disturbed Surfaces Of Wall, Ceiling, Floors Etc, Complete All As Specified And As Directed. 151 Taking Down Old Unserviceable Submain Wiring Any Size 4 / 6 Sq Mm 02 Run Copper Conductor Single Phase With Earth Wire Including Pvc Conduit Complete All As Specified And As Directed. 152 Concealed Point Wiring On Wall And Ceiling / Roof With Necessary Fixing Arrangements Withpvc-Frls Insulated And Unsheathed Heavy Duty Copper Multi-Stranded Conductor Of Size 1.5 Sqmm, 1100 Volts Grade Drawn In And Including Rigid Non Metallic White / Ivory Pvc Conduit Medium Grade Isi Marked Not Less Than 20 Mm Dia With All Conduit Accessories / Fittings Such As Junction Boxes, Bends, Tee, Elbow Etc Including Anodized Ms Sunken Boxes Made Out Of Ms Sheet Of Thickness Not Less Than 1.6 Mm With Earth Dollyand Bakelite Laminated Sheet 3Mm Thick Isi Marked For Fixing Of Switches / Sockets, Fan Regulators, Wall Mountingfittings, Door Bell & Bulkhead Etc With Ms Screw And Cup Washers Including Pvc-Frls Insulated And Unsheathed Copper Multi-Stranded Conductor Of Size 1.5 Sqmm, 1100 Volts Grade For Continuous Earthing Including Cutting The Chases And Making Good The Surface By Cement Mortar ( 1:3 ) And For Matching / Finishing Of New Surfaces Either By Means Of Plaster Of Paris / Putti Or Distemper / Colour Wash With Same Existing Colour Surfaces, One Light / Exhaust Fan / Ceiling Fan & One Bell / Buzzer Point Controlled By One Switch6 / 5 Amp One Way Single Pole. All As Specified And Directed By Engineer-In-Charge 153 All As Per Item No 144 Above Here-In-Beforebut One Switch Socket Outlet Point 3 Pin 5 Amps On Independentboard Complete All As Specified And Directed. 154 All As Per Item No 144 Above Here-In-Beforebut One Switch Socket Outlet Point 3 Pin 5 Amps On Same Board Complete All As Specified And Directed. 155 All As Per Item No 144 Above Here-In-Before But One Light Point Controlled By Two 2-Way Switches, With Cables 1.5 Sq. Mm Size Complete All As Specified And Directed. 156 All As Per Item No 144 Above Here-In-Beforebut For Power Point Wiring With 2.5 Sqmmpvc-Frls Insulated, Unsheathed, Copper Conductor, Stranded 1100 Volt Grade Cable And 2.5 Sqmm Pvc-Frls Insulated, Unsheathed, Copper Conductor, Stranded 1100 Volt Grade Cable As Continuous Earth Lead. 157 Fan Speed Regulator, Electronic Steptype, Suitable For Single Phase Ac, 240 Volts, 50 Hz Stepped Type Electronic Fan Regulator Flush Type On The Existing Phenolic Laminated Sheet Etc. As Reqd, All As Specified And As Directed. 158 Socket Outlet 2 In 1, 3 Pin, 6A Isi Mark Complete All As Specified And Directed 159 Switch Piano, Flush Type Single Pole, One Way 6 Amp, 230 Volt Isi Mark Complete All As Specified And Directed 160 Switch Piano, Flush Type Single Pole, Two Way 6 Amp, 230 Volt Isi Mark Complete All As Specified And Directed 161 Socket Outlet 2 In 1, 3 Pin, 6 , 16A Isi Mark Complete All As Specified And Directed 162 Switch Piano, Flush Type Single Pole, One Way 16 Amp, 230 Volt Isi Mark , Complete All As Specified And Directed. 163 Bell Push Flush Type 240 Volt Ac , Complete All As Specified And Directed. 164 Ceiling Rose, Surface Bakelite, 65Mm X 50Mm, Two To Three Terminalscomplete All As Specified And As Directed. 165 Batten Angle Lamp Holder Insulatedbodywith Back Plate Suitable For Batten Fittings Including Complete All As Specified And As Directed. 166 Ding Dong Sound Door Call Bell Electric Ac 240 Volt, 50 Hz Ding Dong Type, Complete All As Specified And As Directed. 167 Tv Socket , Complete All As Specified And As Directed. 168 Non Metallic Rigid Pvc Conduit, Isi Marked, Conforming To Is 9537, Medium Grade Of Size 25 Mm Dia Including All Fittings Like Bends, Elbow Reducer, Junction Boxes, Tee Bell Mouth All Fixing Accessories Such As Coupler Lock, Nuts, Saddles Pipe Hooks Etc Complete Including Cutting & Chasing Required On Brick Wall Not Exceeding 10 Cm Girth For Concealed Conduit Wiring And Making Good To Disturbed Surface With Cement Mortar 1:3, Complete All As Specified And Directed. 169 Sub Main Wiring With Two Run Of Frls Pvc Insulated Unsheathed Flexible Copper Conductor ( Multistrands ) , Single Core Of Size6.0 Sqmm, 1100 Volts Grade And One Run Of 6 Sqmm Frls Pvc Insulated Unsheathed As Earth ( In Green Colour ) , Flexible Copper Conductor ( Multistrands ) For Continuous Earthing Conforming To Is 694 With Latest Amendmentsincluding Pvc Conduit And Draw In Pvc Rigid Conduit 25 Mm Dia , Connecting Incoming / Outgoing Electric Connections By Using Required Size Copper Lugs / Thimblescomplete In All Respect All As Specified And Directed.Note :- 1. Two Run Of Single Core Cable With One Run Of Contineous Earth Wire Of Copper Conductor Wire Flexible ( Multistrand ) Of Frls Pvc Insulatedand Pvc Conduit 25 Mm Dia Shall Be Measured And Paid As One Unit Length 170 Spn Distribution Box, Double Door Of Protection Grade Ip 43, Powder Coated, Matt Finish With Best Crca Sheet, Fitted With Shrouded Neutral, Insulated Pin Type Copper Bus Bar, Din Rail, Earth Bar Of 12 Way, Confirming To Is 13032 & 8623 Complete All As Specified And Directed. 171 Spn Distribution Box, Double Door Of Protection Grade Ip 43, Powder Coated, Matt Finish With Best Crca Sheet, Fitted With Shrouded Neutral, Insulated Pin Type Copper Bus Bar, Din Rail, Earth Bar Of 8 Way, Confirming To Is 13032 & 8623 Complete All As Specified And Directed. 172 Mcb Spn, 40 To 63 Amps 240 Volts, Ac , 10 Ka Breaking Capacity C Series, Isi Marked And Conforming To Is 8828 / Iec 60898-1, Complete All As Specified And Directed. 173 Mcb Sp, 06 To 32 Amps 240 Volts, Ac , 10 Ka Breaking Capacity C Series, Isi Marked And Conforming To Is 8828 / Iec 60898-1, Complete All As Specified And Directed. 174 Mcb Tpn, 63 Amps 415 Volts, Ac , 10 Ka Breaking Capacity C Series, Isi Marked And Conforming To Is 8828 / Iec 60898-1, Complete All As Specified And Directed. 175 Tpn Distribution Boxdouble Door Of Protection Grade Ip 43, In Fine Powder Coated, Matt Finish With Best Crca Sheet, Fitted With Shrouded Neutral, Insulated Pin Type Copper Bus Bar, Din Rail, Earth Bar Of 4Way, Confirming To Is 13032 & 8623 Including Chasing / Cutting Of Wall And Concealed And Making Good As Existing Surface Complete All As Specified And Directed. 176 Wall Mounted Led Batten 18 / 20 Watt With 01 No Led Tube Rod, Extruded Aluminium Heat Sink Provided For Efficient Heat Dissipation And Integrated Electronic Drivercomplete All As Specified And Directed. 177 Taking Down Old Unserviceable / Serviceable Led Batten 18 / 20 Watt Complete All As Specified And Directed . 178 Re Fixing / Fixing Only Of Old Serviceable Existingled Batten 18 / 20 Watt Complete All As Specified And Directed 179 Wall Mounted Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Integrated Electronic Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size, Complete All As Specified And Directed. 180 Decorative Wall Mounnted Luminaire With & Including 09 Watt Led Lamp Complete As Directed And Specified 181 Led Building Security Light 25 Watt, 230V Complete With All Accessories And Including Connecting Up To Ceiling Rose With 0.5 Sqmm Three Core Copper Flexible Conductor Cable, One Gi Medium Grade Suitable Size Dia Bracket Of Total Length 50 Cm And Fixed To Wall With 2 Nos Ms Clamp And Fastenerall As Specified And Directed. 182 Led Light Fitting 1X9w / 1X10wbulkhead Luminaires Including Led Light Driver Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size , Complete All As Specified And Directed. 183 Taking Down Existing Ceiling Fan Serviceable / Unserviceable Type And Deposite Mes Safe Coustedy, Complete All As Specified And Directed. 184 Refixing / Hanging Of Existing Serviceableceiling Fan Any Size From Mes Store Yard Along With New Connection Wire 3 Core And New Clamp Properly , Complete All As Specified And Directed. 185 Taking Downexisting Exhaust Fan Serviceable Type And Deposite To Mes For Safe Coustedy And Refixing After Plaster Work Alongwith New Fashnut, Mosquto Net And Louvers , Complete All As Specified And Directed. 186 Refixing Of Existing Serviceableexhaust Fan Any Size From Mes Store Yard Along With New Connection Wire 3 Core And New Clamp Properly , Complete All As Specified And Directed. 187 Ceiling Fans Complete With Blades, Down Rods, Electronic Regulator And Accessories, 230 V, 1200 Mm Sweep. Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current Motor ( Bldc ) 188 Exhaust Fans Ac Single Phase 230 / 240 V Of Size 300 Mm Sweep 900 Rpmwith Louver, Mosquto Net Including Cutting Of Hole Of Adequate Size Including Making Good Existing Surfaces Including Fixing With Ms Faster , Complete All As Specified And Directed. 189 Taking Downof Existing Serviceablegeyser Any Size From Qtrs Safely And Deposite To Mes Stroe Yard In Safe Coustady, Complete All As Specified And Directed. 190 Refixing Of Old Serviceable Geysers After Completed Ofthe Plaster And Painting Works Alongwith Fasnut Nut / Bolt Washers Etc And Connection With New 02 Nos Pvc Connections 15Mm Size With Ptmt Nuts Of Both Side Of Length 450Mm Long, Complete All As Specified And Directed. 191 Taking Down Old Unserviceable / Defective Or Serviceable Energy Meter Upto 60 Amps Any Type Any Capacity And Deposite To Mes E / M Store Allas Specified And Directed 192 Refixing Of Serviceable Electric Meter Above 25 Amp Allas Specified And Directed 193 Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cmx60cmx6mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metre Deep Below Normal Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Metre Below Ground Level, Connecting To Galvanised Iron Wire 4.0Mm Dia ( As Earth Lead Wire ) , By Means Of Bolt, Nuts, Check Nuts And Washer Of Galvanised And Earth Wire Protected By Provision Of Galvanised Iron Pipe Light Grade, 15Mm Bore Including Provn Of Concrete Pit In Pcc M-15, Type B-I Using 20Mm Graded Crushed Stone Aggregates With 40Mm Thick Precast Cover Of Size 550 Mm X 550 Mm X 75 Mm Of Rcc ( 1:2:4 ) , Type B-I, Reinforced With Xpm ( Weight Not Less Than 4 Kg / Sqm ) And Frame Of Angle Iron 25X25x3mm With Lugs 2 Nos And With 6Mm Dia Mild Steel Bar Handle Made To Shape, Galvanised Iron Medium Grade 20Mm Bore Pipe For Watering Perforated At Bottom 1.75 Metre Long Placed On Top Edge Of Earth Plate, Common Salt And Charcoal Filling, Test Point Made Out Of Phosphorous Bronze With Fixingarrangement, Funnel, Wire Mesh And Including Earth Work In Any Type Of Soil, Returning Filling In And Removal Of Surplus Soil To A Distance Not Exceeding 50 Metre, All As Per Electricalplate No. 3 Of Ssr 2009 Part-I And Connection To Earth Test Point All As Specified And Testing On Completion. 194 Invertor Point Wiring With One Run Of 1.5 Sqmm Single Core Pvc Insulated Frls Copper Conductor Wire And Draw In Pvc Condit Connected With Switch Boards As Required , Complete All As Specified And Directed .Note :- Pvc Conduit Has Already Been Considered Under Point Wiring Items 195 Deduction To Be Made From Boqfor Sch A Part - Ii ( Schedule Of Credit ) Amount Of Rs. 966959.00 During Aoc.Note: Tenderers Shall Not Quote For This Schedule.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-2023 CorrNo01 Date 26-12-2023
2 19-Dec-2023 CorrNo02 BOQ 26-12-2023
3 19-Dec-2023 CorrNo03 Date 30-12-2023
4 30-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-01-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 665000.0 /-
Tender Value
INR 6.80 Crore /-

BOQ Items

Name of Work: ADDITION / ALTERATION TO EXISTING JCOs AND OR ACCN AT KAMLESH VIHAR, DHAR ROAD UDHAMPUR
Sl. No. Item Description
1Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlarfacings dressed stone work and precast concrete articles complete all as specified and directed.
2Brick work with sub class “B” bricks (using old size bricks) straight or curved on plan exc 6M mean radius build in cement motar 1:6 using all as specified complete all as specified and directed.
3All as per item No 02 but except bricks complete all as specified and directed.
4Brick work with sub class “B” bricks (using old size bricks) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified & directed.
5Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc, complete all as specified and directed.
6Rendering 15mm thick onfair faces of brick work or concrete surfaces in cement motar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
7Rendering 15mm thick on surface other than fair faces of brick work or concrete surfaces in cement motar 1:4 finished using water proofing compound as per manufacture"s instruction, ( WPC to bepaid measured and seperately as supply only)even and smooth without using extra cement complete all as specified and directed.
8Supply only integral water proofing compound complete all as specified and directed.
9Rendering 10 mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed.
10Preparing newlyplasteredsurfaces of walls and applying two coats of oil bound distemper over a coat of Primer complete all as specified and directed.
11Preparation of new plastered surfaces of wall and applying three coat of white washing, complete all as specified and directed.
12Preparation of new plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm , complete all as specified and directed.
13Preparation of new plastered surfaces of ceiling and applying three coat of white washing, complete all as specified and directed.
14Complete removal ofexisting treatmenton wall and applying two coats of oil bound distemper over a coat ofprimer on plasterd surfaces of wall complete all as specified and directed.
15Preparation of new plastered surfaces of wall and applying 3mm thick wall care putty in two coats and smoothening the surfaces with sand paper/mechanised sanding complete all as specified and directed.
16complate removal of existing treatement and preparation of surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm , complete all as specified and directed.
17Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc,complete all as specified and directed.
18Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
19Non skid colouredceramic tiles(Joint free) 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm,in floor jointed in neat cement slurry and pointed with coloured cement to match over and including 15mm thick Screed bed or bedding in cement motar 1:4 in floors etc ,complete all as specified and directed .
20Glazed ceramic tiles jointless light coloured of size 300x600x7mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match,laid over and including 10mm thick plastering in cement mortar 1:4.,complete all as specified and directed .
21Non skid colouredceramic tiles(Joint free) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,in floor jointed in neat cement slurry and pointed with coloured cement to match over and including 15mm thick Screed bed or bedding in cement motar 1:4 in floors etc ,complete all as specified and directed .
22Non skid colouredceramic tiles(Joint free) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match,laid over and including 10mm thick plastering in cement mortar 1:4.,complete all as specified and directed .
23Machine cut kota stone slab flooring with white boarder lining 20mm thick as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as inin skirting, dados, risers to steps etc, laid over and including 10mm thick rendering in cement mortar 1:4 , cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified.
2420 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 20 mm thick screed bedding/ backing layer in CM 1:3including providing nosing to edges of slab and drilling of hole for gas pipe using mechanical method,complete all as specified and as directed by Engineer-in-Charge.Note: Granite stone slab shall be in single piece.
25Marble 18-20 mm (green/any colour shade approved by GE)thick over cement screed bed laid on 15 mm thick CM 1:6 andjointed with white cement slurry mixed with pigment ot match the shadeto flooring / Window cills / steps,riserincl rubbing and polishingincl rounding to edge of marble,complete all as specified and as directed.
26Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and directed.
27Taking down chowkats or frames with shutters (without taking off shutters from the frames)exc 1.50 sqm eachand n exc 4 sqm and removing from site complete all as specified and directed.
2835 mm thick2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members ofdoor shutters as specified in SSR- 2009Part-I Section 8.24(a) ,complete all as specified and directed.
2930 mm thickflush shutters, solid core construction, with particleboard core and plywood face panels,both sides laminated with decorative face veneer with lipping/frame to match ,complete all as specified and directed.
30Solid PVC Door Frames of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
31Factory made solid PVC moulded door shutter 28mm - 30mmthick (stiles) with particle board core with 2,4,or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face complete all as specified and directed.
32Door eye viewer, viewing angle 180 degree, mounting diameter 14mm, total size 4 x 2.5cm (LxD) with good quality glass eye lens, brass chromium plated fixed in position for door shutters , complete all as specified and directed.
33Door seal brush (Aluminium plate with nylon brush) of required length for any size of doors, fixed with stainless steel screw, complete all as specified and directed.Make : Harrison or equivalent.
3418mm thick MDFboard for Kitchencabinet/cup board shutter/Partation/Shelves etc in required size at site made out of 18mm thick MDFboard both side decorative lamination PVC sheet complete all required etc.The panels shall be fabricated using adhesive and secure as required.All edges shall be covered with 2mm thick edge bonding taps or 90° edge bent finish as per manufacturers instructions.
35Pressed steel frames of size 105mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, butt hinges (100mm medium weight-03 Nos), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6., complete all as specified and directed.
36Pressed steel frames of size 125mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, butt hinges (100mm medium weight-03 Nos), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6,complete all as specified and directed.
37Pressed steel frames of size 75mmx60mm for cupboard frames with one or more rebates fabricated out of 1.25mm thick mild steel sheets with and including necessary fixing lugs, continuous (Piano) hinges mild steel bright finished or electrogalvanised width of flaps (when open) 30mm and fixed with chowkhat by rebated and welded, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surfacein cement mortar 1:6, complete all as specified and directed.
38Powder coated Aluminium windows/ventilator complete all as specified and as shown on drawing CEUZ/TD-1564/2016 sheet No. 1/2 to 2/2 for various sizes and pattern with following powder coated aluminium sections :-Notes :-A. The rates quoted for powder coated aluminium sections shall be deemed to include the following:- (i) Rubber gasket for fixing glass to window/vent shutters.(ii) Fixing of window with and including min 75x10 GI screws all around @ 300 c/c (Min 2 Nos on one side) with PVC RAWL PLUGS/Sleeves.(iii) Rollers, concealed lock cum handle & othe fittings for sliding shutters shall be provided as per manufactures instructions and approved by GE.(iv) Silicone sealant shall be applied on internal as well as external periphery of window and masonry joint to avoid water seepage.(v) All other sundries all as per manufacturer instructions and as directed. B. The rates quoted for powder coated sections shall exclude the cost following and shall be paid seerately under respective items of Sch "A"/BOQ:-(i) Glass and wire mesh (ii) 40x40x3 aluminium angle provided on all corners of the windows. (c) Aluminum -U-channel shall be provided for fixing of wire mesh. (d) Powder coated aluminum handles and hinges for fixing of openable shutters C. OTHER (i) No allownace for wastage/overlaps shall be considered for payment. (ii) Range of dimension of opening size has been mentioned. the same shall be fixed as per measurements of opening of windows as per site requirement by the GE during execution of work.(iii) Powder coated aluminuim section shall be provided all as shown on drawings and as directed.
39Three track powder coated aluminium section as in window/vents frame for sliding shutters,complete all as shown on drawings and as directed.
40Powder coated aluminium sections as in window/vents frame for openable shutters ,complete all as shown on drawings and as directed.
41Powder coated aluminium sections as in sliding window shutters,complete all as specified and as directed.
42Powder coated aluminium sections as in openable window shutter ,complete all as specified and as directed.
43Powder coated aluminium tower bolts 75mm long, complete all as specified and as directed.
44Powder coated aluminium butt higes 75mm, complete all as specified and as directed.
45Powder coated aluminium handle 75mm, complete all as specified and as directed.
46Powder coated aluminium plate type II gate and shutter, hook and eyes 100mm and fixed ,complete all as specified and as directed.
47Sheet glass 4.8 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
485mm thick, frosted glasspin head type and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
49Galvanised mild steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm dia and fixed with tinned tacks or galvanised mild steel staples complete all as specified and directed.
5030 mm Continuous (piano) hinges, mild steel, bright finish or electro galvanised ,complete all as specified and directed.
51Magnetic catcher suitable for kitchen cabinet shutters ,complete all as specified and directed..
52Hasp and staple Alumniumanodised lncluding bolt to hinges plate 100mm sizewith mild steel hinge pin including bolt to hinge plate and fixed with screws. complete all as specified and directed.
53Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed complete all as specified and directed.
54250mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
55Aluminium handles cast type anodizedof size 150 mm complete all as specified and directed.
56Preparing new wooden surfaces and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description, not otherwise described over 10 cm width or girth, complete all as specified and directed.
57Preparing new steel surfaces and applying two coats of synthetic enamel paint on steel surfaces over a coat to red oxide/zinc oxide primer any description, not otherwise described over 10 cm width or girth complete all as specified and directed.
58Preparing of old steel surfaces and applying one coats of synthetic enamel paint on steel surfaces , not otherwise described over 10 cm width or girth complete all as specified and directed.
59Viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with "P" or "S" trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe), fixed in repair including lime concrete bedding as required complete all as specified and directed.
60PVC valveless, with top button double action type,syphonic action type flushing cistern, 10 litres capacity, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe, fixed in repairs complete all as specified and directed.
61Vitreous China wash basin, white, flat back, size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets complete all as specified and directed.
62Mirror cabinet PTMT of 400mm x 500 mmwith magnetic looking arrangements fixed with and inclduling wooden plugs with chromium plated brass screws, complete all as specified and directed
63Bevelled edge mirror,size 600x 450 mm of selected qualityglass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers ,complete all as specified and directed.
64Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges with and including chromium plated brass brackets, brass screws ,complete all as specified and directed.
65Towel ring brass chromium plated, fixed with brass screws and plugs ,complete all as specified and directed.
66Chromium plated soap dish, fixed to plugs with chromium platwd brass screws complete all as specified.
67Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long ,complete all as specified and directed.
68Bib tap Chromium plated fancy type long body 15 mm bore,screwed down screwed to iron pipe,fixed in repair,complete all as specified and directed.
69Stop cock /angle Chromium plated fancy type long body 15 mm bore,screwed down screwed to iron pipe,fixed in repair ,complete all as specified and directed.
70Wall mixer with provision for overhead shower with 115 mm long bend pipe on upper side, connecting legs and wall flanges. Make: ESS cat part No EC-10 or equivalent.
71Brass centre hole mixer chromium plated without pop up waste system 15mm bore for mixing hot and cold water screwed down for iron pipe for WHB,complete all as specified and directed.
72Sink mixer with regular spout wall mountatedwith connectings legs & wall flanges and including all necessary fittings ,complete all as specified and directed.
73Sinks with drainage boardmade of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm incl 32mm waste fittings brass chromium plated etc fixed in repair,complete all as specified and directed.
74Stainless steel plate racks of size 775mm x 900 x 250mm and thickness of SS strip of 1mm fixed on wall etc ,complete all as specified and directed.
75Shower rose brass chrominium plated 125mm with arm and without swivel joints to steel pipe size, fixed in repair,complete all as specified and directed.
76PVC connections 15 mm size of superior quality with PTMT nuts both sideof length 600mm fixed in repair complete all as specified and directed.
77Rotational moulded polyethylene water storage tank 500 Ltrs capacity(ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.(Minimum weight 20mm - 210 gms)complete and making connections with existing water supply line,fixed in repairincluding dismantaling of existing water tank,complete all as specified and directed.
78Disconnecting existing tanks capacity 500ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position and Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes,including 20 mm dia float valve ,complete all as specified and directed..
79Rotational moulded polyethylene water storage tank 1000 Ltrs capacity(ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.(Minimum weight 20mm - 210 gms)complete and making connections with existing water supply line fixed in repair including dismantaling of existing water tank,complete all as specified and directed.
80Disconnecting existing tanks capacity 1000ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position and Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes,including 20 mm dia float valve ,complete all as specified and directed.
81Peg set of six, stainless steel of suitable length,complete all as specified and directed.
82Curtain rod 25 mm dia decorative/fancy type stainless steel with with brackets and knobs at both ends as per site requirement incl taking down old existing pipes with accessories complete all as directed.
83Taking down steel tubing and connection of 15mm bore of pipe ,complete all as specified and directed.
8415mm bore GI tubingmedium grade with all fittings and fixed complete to wall and ceiling or laid in floors etc including cutting chases in brick wall pinning in making good in CM 1:3 to facings where required, incl 10cm exc but not exc 20cm in girth.
8515mm bore GI tubing (medium grade) with all fittings and fixed complete fixed complete to walls and ceiling or laid in floors/roofs, complete all as specified and directed.
86Re-fixing old steel tubing and connection 15 mm dia bore to wall and laid in floors ,complete all as specified and directed.
87Taking down steel tubing and connection of 20mm bore of pipe ,complete all as specified and directed.
8820mm bore GI tubing (medium grade) with all fittings and fixed complete fixed complete to walls and ceiling or laid in floors/roofs, complete all as specified and directed.
89Re-fixing old steel tubing and connection 20mm dia bore to wall and laid in floors ,complete all as specified and directed.
90Taking down steel tubing and connection of 25mm bore of pipe ,complete all as specified and directed.
9125mm bore GI tubing (medium grade) with all fittings and fixed complete fixed complete to walls and ceiling or laid in floors/roofs, complete all as specified and directed.
92Re-fixing old steel tubing and connection 25mm dia bore to wall and laid in floors ,complete all as specified and directed.
93Taking down unservicable Gun metal globe orgate valve 20mm or 25mm dia bore ,complete all as specified and directed.
94Gun metal globe orgate valve with iron wheel head, screwed both ends for iron pipe and fixedbore dia of pipe 20 mm complete all as specified and directed.
95Gun metal globe orgate valve with iron wheel head, screwed both ends for iron pipe and fixedbore dia of pipe 25 mm ,complete all as specified and directed.
96110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm with rubber ring joint, fixed to walls with dash ture nut and MS ring (25x6 FI used) bolt at every 1.5 mtrs length complete, including taking out old pipe with all fittings ,complete all as specified and directed.
97110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm with rubber ring joint, laid in treanch or in floor with dash ture nut and MS ring (25x6 FI used) bolt at every 1.5 mtrs length complete, including taking out old pipe with all fittings, complete all as specified and directed.
9875mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm with rubber ring joint, fixed to walls with dash ture nut and MS ring (25x6 FI used) bolt at every 1.5 mtrs length complete, including taking out old pipe with all fittings, complete all as specified and directed.
9975mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm with rubber ring joint, laid in treanch or in floor with dash ture nut and MS ring (25x6 FI used) bolt at every 1.5 mtrs length complete, including taking up/down out old pipe with all fittings ,complete all as specified and directed.
100PVC (SWR) Bends/junction (any radius) for 110mm bore complete all as specified and directed.
101PVC (SWR) Bends/junctionwith access door (any radius) for 110mm bore complete all as specified and directed.
102PVC (SWR) Bends/junctionwith access door (any radius) for 75mm bore complete all as specified and directed.
103PVC (SWR) Branch pieces single( Single Y) equal or unequal for 110mm bore ,complete all as specified and directed.
104PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete all as specified and directed.
105PVC (SWR) multi floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole,complete all as specified and directed.
106Taking down existing roof treatmentof any description and any type and position and removing the deberis from site outside MD land ,complete all as specified and directed.
107Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface including Brushing neat cement slurry with 3kg of cement per sqm finish ever and smooth (w/o using extra cement) including WPC as per manufacture instruction at any height etc. (WPC will be measured and paid separately as supply only) ,complete all as specified and directed.
108Roof treatment for Non Accessible Roof :- priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm, Top surface of roof after carrying out treatment shall be provided with two coats of aluminium paint over a coat of primer complete all as specified and directed.
109Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment ,complete all as specified and directed.
110PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate),40mm thick, as in padding finished even and smooth witout using extra cement ,complete all as specified and directed.
111Taking down old PCC tiles from roof and removing bedding at any position and removing the deberis outside the MD land ,complete all as specified and directed.
112Roof tretment for accessible roof :- priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm ,complete all as specified and directed.
113Cement concrete tiles, coloured, machine pressed, factory made of size 20cmx20cm, 20mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid over and including 15mm thick screed layer in CM 1:4 over roofs,complete all as specified and directed.
114PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate),WPC along side wall adjoining to roof in concave shape ,complete all as specified and directed.
115Water proofing treatment to floor & vertical surfaces of sunken portion complete comprising the following: - (a) After demolition of floor & lime concrete etc. remove all loose particles along with existing water proofing treatment (any no. of layers) with wire brushes and cleaning the surfaces with water. (b) Brushing cement slurry with 1.2 kg of cement per square metre duly blended with & including water proofing compound. (c) 15 mm thick (Average thickness) plaster in cement mortar (1:3) mixed with WP compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 Hrs by ponding.(d) Applying self adhesive type APP based polymeric membrane minimum weighing not less than 3.6 kg/ Sq. m and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gm/Sq. m),(e) M&L forPCC 1:7 :12 for filling of sunken portion after conceling all menbrane and sealing all joints to the entire with broken bats and light weight,complete all as specified and directed.
116Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixed with galvanized steel staples supplied and fixed completeto wood or steel member, weight exc 4 kg per Sqm ,complete all as specified and directed.
117Framed work rolled section as in framing compound girder staging for end bars, shouldered and riveted, forged into spikes, framed guard bars, dooriron, ladders walk rails, railings, frame work for tanks, water tank,cooler frameas and the like built up from two or more beam or channel section or angles with plates stiffeners etc conforming to Fe-290grade E-165 ,complete all as specified and directed.
118Framed work as in safety doors fabricated out of mild steel hollow sections of sheet thickness not less than 1.6mm thick, MS square bars or other section with, rails, braces, sliding door bolt fabricated out of 16mm Ms round bar, staple etc with and including provn for fixing of wire mesh, complete and fixed to mild steel pressed chowkhats. Note: (ii) Sketch drawing for safety door shall be provided by the GE during execution of work. (ii) Wire mesh shall be measured and paid for seperately
119Demolition of reinforced cement concrete of any description and any position not other wise specifically provided,complete all as specified and directed.
120RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate)as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like,complete all as specified and directed.
121RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate)as in beams, cantilevers, bressummers, lintels over 1.5m span ,complete all as specified and directed.
122Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
123Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
124Hard core of broken stone or boulders of gauge not exc 63 mm deposited ,spread and leveled in layer not exc 15 cm thick complete all as specified and directed.
125PCC 1:3:6 (nominal mix) type C-1(using 20mm graded crushed stone aggregates) as in hold fastcomplete all as specified and directed.
126Brick work with sub class “B” bricks (using old size bricks) straight or curved on plan exc 6M mean radius build in cement motar 1:6 using all as specified complete all as specified and directed.
127RCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate)as incoping/benching and all other similar works including necessary formwork,complete all as specified and directed.
128RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate)as in surface channel & drain,complete all as specified and directed.
129Extra for forming fair finished drain or channel 30 cm inner girth of cement concrete using extra cement including forms moulds, mitred/ stopped endsetc, complete all as specified and directed.
130Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slaband similar articles including necessary moulds/formwork set in cement mortar (1:6) complete all as specified and directed.
131TMT steel bars 10mm dia and over as in reinforcement for concrete, cut to length, bent to shape requuired, including cranking, bending spirally for hooping for columns, hooping endand binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified
132TMT steel bars 6 to 8mm dia as in reinforcement for concrete, cut to length, bent to shape requuired, including cranking, bending spirally for hooping for columns, hooping endand binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified
133All as per Srl item No 124 above but5mm dia and over upto and including 10mm in stirrups, spacers and binders complete all as specified
134Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided,complete all as specified and directed.
13540mm thick PCC 1:2:4 C-2 (using 20mm graded crushed stone aggregate) as in plinth protection / path/ any paved area finishing cement concrete surface even and smooth complete all as specified and directed.
13625mm thick, PCC 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregates)as in floor finish,surface finished even and smooth without using extra cement complete all as specified and directed.
137Providing anti termite treatment post construction along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron,complete all as specified and directed.
138Anti termite treatment postconstruction of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors,complete all as specified and directed.
139Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type ofsoil, complete all as specified and directed.
140Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed.
141Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
142Reinforced concrete pipe, 450mm dia class NP3, laid and jointed, complete all as specified and directed.
143Reinforced concrete pipes, class NP3, laid in trenches, jointing and testing and jointed, complete with collarsdrain pipe, 150mm bore conforming to IS at any depth after they are laid and tested. Including demolition and breaking up old drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar,complete all as specified and directed.
144Concrete bed to drain pipes laid to falls including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) for 150mm bore pipe complete all as specified and directed.
145Construction of septic tank for 100 users (Brick constructions) complete all as specified and as shown on drawing No. CEUZ/TD/1585/21 sheet No. 1/4 toto 4/4
146Construction of soakage well 1.80m dia and 4.50m deep (internal dimensions) (Brick construction), complete all as specified and as shown on drawing No.CEUZ/TD/1585/21 sheet No. 1/4 toto 4/4
147Cement concretetype D2 1:4:8 (40mm graded crushed stone aggregate), 75mm thick as in sub base complete all as specified and directed.
148Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator ,complete all as specified and directed.
149Factory made Pre-cast cement concrete block type B1, 1:2:4 as in kerb stone made to shape as directed, exc. 10 cm in width and setting in mortar 1:4 including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required,complete all as specified and directed.
150Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling,floors etc, complete all as specified and as directed.
151Taking down old unserviceable submain wiring any size 4/6 Sq mm 02 run copper conductor single phase with earth wire including PVC conduit complete all as specified and as directed.
152Concealed point wiring on wall and ceiling/roof with necessary fixing arrangements withPVC-FRLS insulated and unsheathed heavy duty copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white/ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dollyand Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mountingfittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/Putti or distemper / colour wash with same existing colour surfaces,One light /Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch6/5 Amp one way single pole. all as specified and directed by Engineer-in-Charge
153All as per item No 144 above here-in-beforebut One switch socket outlet point 3 pin 5 Amps on Independentboard complete all as specified and directed.
154All as per item No 144 above here-in-beforebut One switch socket outlet point 3 pin 5 Amps on same board complete all as specified and directed.
155All as per item No 144 above here-in-before but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size complete all as specified and directed.
156All as per item No 144 above here-in-beforebut for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
157Fan speed regulator, electronic steptype, suitable for single phase AC, 240 volts, 50 Hz stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd, all as specified and as directed.
158Socket outlet 2 in 1, 3 pin, 6A ISI Mark complete all as specified and directed
159Switch piano, flush type single pole, one way 6 Amp,230 Volt ISI Mark complete all as specified and directed
160Switch piano, flush type single pole, two way 6 Amp,230 Volt ISI Mark complete all as specified and directed
161Socket outlet 2 in 1, 3 pin, 6 , 16A ISI Mark complete all as specified and directed
162Switch piano, flush type single pole, one way 16 Amp,230 Volt ISI Mark ,complete all as specified and directed.
163Bell Push flush type 240 volt AC ,complete all as specified and directed.
164Ceiling rose, surface bakelite, 65mm x 50mm, two to three terminalscomplete all as specified and as directed.
165Batten angle lamp holder insulatedbodywith back plate suitable for batten fittings including complete all as specified and as directed.
166Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type,complete all as specified and as directed.
167TV socket ,complete all as specified and as directed.
168Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3,complete all as specified and directed.
169Sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size6.0 Sqmm, 1100 Volts grade and one run of 6 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendmentsincluding PVC conduit and draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimblescomplete in all respect all as specified and directed.Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FRLS PVC insulatedand PVC conduit 25 mm dia shall be measured and paid as one unit length
170SPN Distribution Box, double door of protection grade IP 43, powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way, confirming to IS 13032 & 8623 complete all as specified and directed.
171SPN Distribution Box, double door of protection grade IP 43, powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed.
172MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity "C" Series,"ISI marked and conforming to IS 8828/IEC 60898-1, complete all as specified and directed.
173MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity "C" Series,"ISI marked and conforming to IS 8828/IEC 60898-1,complete all as specified and directed.
174MCB TPN, 63 Amps 415 volts, AC , 10 KA breaking capacity "C" Series,"ISI marked and conforming to IS 8828/IEC 60898-1,complete all as specified and directed.
175TPN Distribution Boxdouble door of protection grade IP 43,in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.
176Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic drivercomplete all as specified and directed.
177Taking down old unserviceable/serviceable LED batten 18/20 watt complete all as specified and directed .
178Re fixing/fixing only of old serviceable existingLED batten 18/20 watt complete all as specified and directed
179Wall mounted LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with integrated electronic driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed.
180Decorative wall mounnted luminaire with & including 09 watt LED lamp complete as directed and specified
181LED building security light 25 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastenerall as specified and directed.
182LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size ,complete all as specified and directed.
183Taking down existing ceiling fan serviceable/unserviceable type and deposite MES safe coustedy,complete all as specified and directed.
184Refixing/hanging of existing serviceableceiling fan any size from MES store yard along with new connection wire 3 core and new clamp properly ,complete all as specified and directed.
185Taking downexisting Exhaust fan serviceable type and deposite to MES for safe coustedy and refixing after plaster work alongwith new fashnut, mosquto net and louvers ,complete all as specified and directed.
186Refixing of existing serviceableexhaust fan any size from MES store yard along with new connection wire 3 core and new clamp properly ,complete all as specified and directed.
187Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
188Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep 900 RPMwith louver, mosquto net including cutting of hole of adequate size including making good existing surfaces including fixing with MS faster ,complete all as specified and directed.
189Taking downof existing serviceablegeyser any size from qtrs safely and deposite to MES stroe yard in safe coustady,complete all as specified and directed.
190Refixing of old serviceable geysers after completed ofthe plaster and painting works alongwith fasnut nut/ bolt washers etc and connection with new 02 Nos PVC connections 15mm size with PTMT nuts of both side of length 450mm long,complete all as specified and directed.
191Taking down old unserviceable / defective or serviceable energy meter upto 60 Amps any type any capacity and deposite to MES E/M store allas specified and directed
192Refixing of serviceable electric meter above 25 Amp allas specified and directed
193Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
194Invertor point wiring with one run of 1.5 Sqmm single core PVC insulated FRLS copper conductor wire and draw in PVC condit connected with switch boards as required ,complete all as specified and directed .Note :- PVC conduit has already been considered under point wiring items
195Deduction to be made from BOQfor Sch "A" Part - II (Schedule of credit) Amount of Rs. 966959.00 during AOC. Note: Tenderers shall not quote for this schedule.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy