Tender For Servicing / Maintenance / Repair Of External Water Supply Lines And Allied Works At Mh Jodhpur And Ce Office Complex And Servicing / Maintenance / Repairing Of Internal / External Electrification, Summer / Winter Appliances And Allied Wor, jodhpur-Rajasthan

Military Engineer Services-MES has published Tender For Servicing / Maintenance / Repair Of External Water Supply Lines And Allied Works At Mh Jodhpur And Ce Office Complex And Servicing / Maintenance / Repairing Of Internal / External Electrification, Summer / Winter Appliances And Allied Wor. Submission Date for this Tender is 29-12-2023. Rough Finishing Tools Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

40783159
Corrigendum : Tender For Servicing / Maintenance / Repair Of External Water Supply Lines And Allied Works At Mh Jodhpur And Ce Office Complex And Servicing / Maintenance / Repairing Of Internal / External Electrification, Summer / Winter Appliances And Allied Wor
Open Tender
Indian
Rajasthan
jodhpur
29-12-2023

Tender Details

Servicing / Maintenance / Repair Of External Water Supply Lines And Allied Works At Mh Jodhpur And Ce Office Complex Andservicing / Maintenance / Repairing Of Internal / External Electrification, Summer / Winter Appliances And Allied Works At Dad Complex Jodhpur Under Ge ( Army ) No 2 Jodhpur; 1 Taking Up / Down Old Di / Gi Tubing Connection Of 20Mm Bore Including Clearing ( From Trenches / Wall / Roof ) Complete All As Spsecified And As Directed. 2 All As Per Item No 01 Above But For 25Mm Bore 3 All As Per Item No 01 Above But For 40Mm Bore 4 All As Per Item No 01 Above But For 50Mm Bore 5 All As Per Item No 01 Above But For80mm Bore 6 All As Per Item No 01 Above But For 100Mm Bore 7 All As Per Item No 01 Above But For150mm Bore 8 Supply And Laying For 20 Mm Bore Galvanised Steel Tubing Medium Grade With All Fittings And Fixtures Laid In Trench Or Ceiling Or Laying In Floors Complete All As Spsecified And As Directed. 9 All As Per Item No 2 Above But 25 Mm Dia Bore. 10 All As Per Item No 2 Above But 40 Mm Dia Bore. 11 All As Per Item No 2 Above But 50 Mm Dia Bore. 12 All As Per Item No 2 Above But 80 Mm Dia Bore. 13 All As Per Item No 2 Above But 100 Mm Dia Bore. 14 Material And Labour Di Pipes Of Size 100Mm Dia With Spigot And Socket End Centrifugally Cast Class K- 9 , In Any Length Laid In Trenches / On Surface / Over Masonary Pillar And Connection To Old Or New Position Complete All As Spsecified And As Directed.. 15 Material And Labour Di Pipes Of Size 150Mm Dia With Spigot And Socket End Centrifugally Cast Class K- 9 , In Any Length Laid In Trenches / On Surface / Over Masonary Pillar And Connection To Old Or New Position Complete All As Spsecified And As Directed.. 16 Taking Up / Down Old Unserviceable Gate Valve / Ball Valve Of Size 20 / 25 / 40 / 50 Mm Bore Complete All As Spsecified And As Directed. 17 Supply And Fix Gun Metalgatevalve Heavy Duly Isi Marked With Iron Wheel Head Screwed Both Ends For Iron Pipes 20 / 25 Mm Bore Dia Complete All As Spsecified And As Directed. 18 All As Per Item No 11 Above But 40 Mm Size. 19 All As Per Item No 11 Above But 50 Mm Size. 20 Taking Up Old Unserviceable / Defective Cast Iron Non Return Valveand Sluice Valve Flanged Type Of Any Make 80 To 150 Mm Bore Dia Complete All As Spsecified And As Directed. 21 Supply And Fix 80 Mm Dia Bore Cast Iron Non Return Valve Flanged Type Heavy Duty Conforming To Is With Rubber Gasket Joints Including Bolts, Nuts, Etc Complete All As Spsecified And As Directed. 22 All As Per Item No 15 Above But 50 Mm Dia Bore. 23 Supply And Fix Cast Iron Sluice Valve Of Size 150 Mm Dia Flanged Of Class Pn 1.6 Confirming To Is With Rubber Gasket Joints Bolts Nuts Etc Complete All As Spsecified And As Directed. 24 All As Per Item No 17 Above But Sluice Valve Of Size 100 Mm Dia. 25 All As Per Item No 17 Above But Sluice Valve Of Size 80 Mm Dia. 26 Supply And Fix In Repairs Cast Ironfoot Valve With Leather Flap Scaling Clamped On Cast Iron Disc Plates Of Size 100 Mm Dia Complete All As Spsecified And As Directed. 27 All As Per Item No 20 Above But 80 Mm Dia. 28 Taking Down Carefully Spindle Of Cast Iron Sluice Valve Of Size 80Mm Boredismantling Parts And Reassembling By Replacement Of Newbrass Spindle Suitable For 80Mm Dia Sluice Valve, Class Pn 1.0, And Refixing In Original Position Including Provision Of Nuts, Bolts, Washers, Rubbers Gaskets Etc Complete All As Spsecified And As Directed. 29 M&L For Replacement Of Pressure Gauge To Read In Is / Bsunit Type 0 To 10 Kg / Cm2 And 0 To 150 Psi Including Taking Down Old One Complete All As Spsecified And As Directed. 30 M&L For Painting Of Sluice Valve / Nrv Upto 80Mm Dia As Per Existing Colour Complete All As Spsecified And As Directed. 31 M&L For Painting Of Valve Chambar Plaster Portion With Cement Base And Steel Portion With Synthetic Enamel Paint Of Any Size Complete All As Spsecified And As Directed. 32 S&F In Replacement Ci Butterfly Valve 80 Mm Dia With Lever Operated Ci Disc Nitrile / Epdm Rubber Lining Test Pressure Pn-1.6 And Ms Nut Bolt And Washers And Pair Of Rubber / Fibers Required For The Work Will Be Supplied By Contractor For Fixing In Position Complete All As Directed. 33 All As Per Item No-26 Above But 100 Mm Dia 34 All As Per Item No-26 Above But 150 Mm Dia 35 M&Lfor Ruber Gas Ket Joint / Tyton Jointfor Ci / Di Pipe Of Size 80 Mm Bore Complete All As Spsecified And As Directed. 36 M&Lfor Ruber Gas Ket Joint / Tyton Jointfor Ci / Di Pipe Of Size 100 Mm Bore Complete All As Spsecified And As Directed. 37 M&Lfor Ruber Gas Ket Joint / Tyton Jointfor Ci / Di Pipe Upto Size 150 Mm Bore Complete All As Spsecified And As Directed. 38 M&L For Construction Of Valve Chembers With Ms Cover 3 Mm Thick Of Valve Pit Of Size 1200X1200x1200 Mm ( Internal Dimensions ) Including Necessary Excavation, Earth Work 150 Mm Thickpcc 1:4:8 Type D2 As In Foundation, Pcc 1:2:4 Type B1 In Coping Plastering 15 Mm Thick In Cm 1:4, And Angle Iron Frame4ox40x6 Mm And Locking Arrangement Including Painting With Two Coat Of Synthetic Enameled Paint Over A Coat Of Redoxide Primer After Preparation Of Surface Complete All As Spsecified And As Directed. 39 M&L For Construction Of Valve Chembers With Ms Cover 3 Mm Thick Of Valve Pit Of Size 900X900x900 Mm ( Internal Dimensions ) Including Necessary Excavation, Earth Work 150 Mm Thickpcc 1:4:8 Type D2 As In Foundation, Pcc 1:2:4 Type B1 In Coping Plastering 15 Mm Thick In Cm 1:4, And Angle Iron Frame4ox40x6 Mm And Locking Arrangement Including Painting With Two Coat Of Synthetic Enameled Paint Over A Coat Of Redoxide Primer After Preparation Of Surface Complete All As Specified And Directed 40 M&L For Construction Of Valve Chembers With Ms Cover 3 Mm Thick Of Valve Pit Of Size 600X600x600 Mm ( Internal Dimensions ) Including Necessary Excavation, Earth Work 150 Mm Thickpcc 1:4:8 Type D2 As In Foundation, Pcc 1:2:4 Type B1 In Coping Plastering 15 Mm Thick In Cm 1:4, And Angle Iron Frame40x40x6 Mm And Locking Arrangement Including Painting With Two Coat Of Synthetic Enameled Paint Over A Coat Of Redoxide Primer After Preparation Of Surface Complete All As Specified And Directed 41 M&L P:C:C 1:2:4 Type B1 ( 20 Mm Graded Stone Agg ) As In Sub Base 200 Mm Thick As Per Tank Size Including 15 Mm Thick Cement Plaster On Top Side Of Concrete Surface Including Necessary Form Work For Pcccomplete All As Specified And Directed 42 Supply And Fixing Pvc Float Valve ( Ball Cock Bady With Epoxy Coated Aluminium Rod & Hd Ball ) Of Size 15 / 20 Mm Dia.Including All Fittings And Taking Down Unserviceable Complete All As Spsecified And As Directed. 43 All As Per Item No 36 But 35 / 40 Mm Dia 44 Excavation In Trenches Not Exc 1.5 Meter Wide & Not Exc 1.5 Mtr In Depth: For Foundationetc Or For Manholes, Laying Of Pipe In Soft And Loose Of Soil And Getting Out Complete All As Specified And Directed 45 Returing Filling In Trenches Including Watering And Well Ramming In Layer Not Exc 25 Cm Thick In Soft / Loose Soil Complete All As Spsecified And As Directed. 46 Removing Excavated Material ( Soil ) To A Distance Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above Starting Point Complete All As Spsecified And As Directed. 47 Supply And Fixing In Replacement Of Battery 12 Volt 180 Ah Maintenance Free Complete All As Spsecified And As Directed. 48 M & L For Cutting The Existing Bituminous Road / Pcc Road Or Path As Per Site Requirment In 20 Cm Depth Including Refilling And Consolidating The Disturbed Portion Using Pcc / Bituminous For Making Good As Existing Surface Complete All As Spsecified And As Directed. 49 Earthing Complete With Galvanised Steel Earth Plate Electrode 60×60Cm× 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not LessThan 1.5 Metres Below Normal Ground Level, Connected To Galvanised Iron Strip 25×4Mm Size Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel Check Nuts And Washers Of Brass Including Necessary Earth Work, Pcc Chamber , Ci Cover With Frame, Funnel Wire Mesh, Earth Lead Protection Pipe 40 Mm Dia, Watering Pipe 15 Mm Dia, 7.5 Meter Earth Lead Etc All As Shown In Electrical Plate No 5 In Ssr Part-I And Connected To Earth Test Point / Lt Panel / Pump Including Testing On Completion Complete All As Spsecified And As Directed. 50 Dewatering By Using Pump As Required And , Removal Of Mud And Settled Silt Including Scrapping Of Complete Inner Surface With The Help Of Wire Brush Etc And Therefore Cleaning By Water And Bleaching Of The Following Oh Tank / Ug Sumps At Mh Jodhpur / Ce ( Army ) Jodhpur Area And Apply Two Coat Of Lime Wash To All Internal Surface Of Wall / Bottom / Ceiling And Two Coat Of Apex Emulsion Painting To All External Surface Including Top Surface And Painting To Oblitering Labels Shall Be Not Less Than 60X40 Cm Using Black Paint To Match With Existing Dimension And Writing Particulars Such As Capacity Of Sump , Date / Due Date Of Cleaning Etc Useing White Paint . Including Disposal Of Mud Silt Etc Obtained After Cleaning Up To 50 M Away Complete All As Spsecified And As Directed. :- ( A ) Oh Tank Of Capacity 5000 To 10000 Glns ( B ) Ug Sump Capacity 50000 To 600000 Glns 51 S&F In Replacement Nut, Bolt, Washer Of Different Size Isi Marked 52 S&F In Replacement Gland Dori Of Different Sizesisi Marked 53 Supply Only Greaseisi Marked 54 M&L For Disconnecting Carefully The Centrifugal Pump Set Of Capacity 15 / 20 Hp And Rewinding Of Copper Winding Of Motor With Super Enamelled Copper Wire With Existing Size And Gauge Including Varnishing, Heating And Testing, Commissioning And Reconnecting All As Required To The Entire Satisfaction Complete All As Spsecified And As Directed. 55 M & L For Repairing / Overhauling Ofthe Following Spit Cage Centrifugal Pump Set Coupled With Motor By Replacing Of Unserviceable Parts Like Bearings, Sleeves Bushes, Bearings Housing Shaft, Gunmetal Impeller Etcassembling The Pump With New Packing Materials, Nuts And Bolts, Washers And Checking The Alignment Connectingup With Delivery, Suction Pipes And Testing For Pump Set Ofpump Set Of 15 / 20 Hp Capacity Complete All As Specified And Directed 56 All As Per Srl Item No 49 Above But For Pump Set Of 7.5 Hp Capacity. 57 All As Per Srl Item No 49 Above But For Pump Set Ofpump Set Of 10 Hp Capacity. 58 M&L For Disconnecting Carefully The Sewage Pump Set Of Capacity 7.5 Hp And Rewinding Of Copper Winding Of Motor With Super Enamelled Copper Wire With Existing Size And Gauge Including Varnishing, Heating And Testing, Commissioning And Reconnecting All As Required To The Entire Satisfaction Complete All As Specified And Directed 59 M&L For Disconnecting Carefully The Mono Block Pump Set Of Capacity 5 Hp To 8 Hp And Rewinding Of Copper Winding Of Motor With Super Enamelled Copper Wire With Existing Size And Gauge Including Varnishing, Heating And Testing, Commissioning And Reconnecting All As Required To The Entire Satisfaction Complete All As Specified And Directed 60 Dismantling, Removingpump Set Of Capacity 5 Hp Pump Set And Taking Out Electrical Connection Taking For Servicing Of Pump Motor To Workshop For Machining, Complete Greasing. Changing Gland Packing, Minor Parts Like Rubber / Steel Bushing, Bearing , Nut Bolts And Re Fixing The Same To There Same Position With Necessary Fixing Arrangement Complete All As Specified And Directednote- All Required T&P Will Be Included In Above Quated Rates. 61 All As Per Srl Item No 56 But Submersible Pump Set Of 3 Hp 62 S&F In Replacement Fully Automatic Star Delta Motor Starter Suitable For 15 Hp , With Single Phase Protectionac-3, 415V, 50 Hz, 3 Phase Suitable For Existing In Panel Complete All As Specified And Directed 63 S&F In Replacement Fully Automatic Star Delta Motor Starter Suitable For 7.5Hp, With Single Phase Protection, Ac-3, 415V, 50 Hz, 3 Phase Suitable For Existing Lt Panel Complete All As Specified And Directed 64 S&F In Replacement Fully Automatic Star Delta Motor Starter Suitable For 10Hp, With Single Phase Protection, Ac-3, 415V, 50 Hz, 3 Phase Suitable For Existing Lt Panel Complete All As Specified And Directed 65 M&L For Site Clearance Complete All As Specified And Directed 66 M&L 100 Mm Hardcore Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed 67 M&L For Pcc ( 1:4:8 ) Type C-2 Using 40Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And Directed 68 M&L For 80 Mm Thick Factory Made Pre Cast Cement Concrete Rubber Moulded Laquer Finish Using Chemical And Admixure Inter Locking Tiles Having Compressive Strength Not Less Than 400 Kg / Sqcm, Of Shape And Colour As Approved By Ge , Laid Over And Including 25Mm Thickcompacted Approved Sand Cushioned Surface, Joints Filled By Fine Sand And Compacting The Top Surfaces Of Paver Blocks After Laid Etc Of Approved Make Complete All As Specified And Directed 69 Supply And Fix Pvc Insulated Submersible Cable 3 Core Flat Copper Conductor ( Including Jointing Material ) Size 6 Sqm 1100 Volt Complete All As Specified And Directed 70 M&L For Repair Of Leakage Of Pipe Line 80 To 150Mm Dia Any Size / Type Incl Exacavation, Dewatering, Cleaning, Repairing Of Pipe Line Leakage Including All Reqd Items For Repair At Site And Returning / Filling And Matching As Per Existing Complete All As Specified And Directed. 71 M&L For Repair Of Leakage Of Pipe Line 20 To 50 Mm Dia Any Size / Type Incl Exacavation, Dewatering, Cleaning, Repairing Of Pipe Line Leakage With Reqd All Accessories At Site And Returning And Matching As Per Existing Complete All As Specified And Directed. 72 S&F Pvc Insulated 2.5 Sqmm Unsheathed 3 Core Round Copper Conductor Stranded Cable Wire 1100 V Grade Isi Marked With Suitable Size Of Pvc Conduit With Proper Fixing On Wall / Piller Complete All As Specified And Directed 73 Supply And Fixing In Replacement Of Rotational Moulded Polyethylene Water Storage Tanks 500 Lts ( Cylindrical Vertical With Closed Top ) Hoisted And Fixed In Position, Complete All As Specified And Directed 74 S& F In Replacement Single Phase Preventer For 3 Phase Motor Fixed For Star Delta Starter Complete All As Specified And Directed 75 S& F Volt Meter 0-500 Volts Square / Round Digital Type Incl Taking Down Old One Complete All As Specified And Directed 76 S& F Amp Meter 0-200 Amps Square / Round Digital Type Incl Taking Down Old One Complete All As Specified And Directed 77 S&F In Replacement 3 Pole Power Contactor For Starter Incl Taking Down Complete All As Specified And Directed 78 M&L For Spray Painting Of Complete Water Pumpset Of Cap 7.5 Hp To 20 Hp With Two Coats Of Synthetic Enameled Paint Of Specified Colour After Preparation Of Surface And Writing Letters And Numbers Complete All As Specified And Directed 79 S&F Bib Taps Of 20Mm Dia Bore, Cast Copper Alloy With Clutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specifed And Directed 80 M&L For Cross Arms, Bracings, Supports, Clamps, Angle Iron, Flats And Back Plates Febricated From Ms Structural Steel Sections Including Nuts, Bolts And Washers Of Suitable Sizes Including Welding, Bending ( Cold Or Hot ) , Drilling Holes For Bolts In Any Shape Or Size As Indicated Or Directed And Inclusive Of Two Coats Of Aluminum Paint Over One Coat Of Red Oxide Primer Complete All As Specified And Directed 81 Dismantling, 500 Lph Reverse Osmosis Plant For Servicing / Repair And Replacement Of Unserviceable Parts For Smooth Functioning Of System And Re-Fixing The Same To It Same Position With Necessary Fixing Arrangement Of Ro Plant Complete All As Directed At Site. Note:- Servicing Of Ro Plant Will Be Carried Out Twice In One Year Complete All As Specified And Directed 82 Repair / Replacement Of Membarane For 500 Lph Ro Plant Of 250 Ltr Capacity Complete All As Directed At Site. Make : Hydranautics, Dow, Aqua ( Each Plant Having 2 Nos 250 Ltrs Of Membarane ) 83 Antiscalant Liquidchemicals Are Supplied By The Contractor For Dosing And Cleaning Of Reverse Osmosis Plant ( Ro ) In Daily Basis Complete All As Specified And Directed 84 Hydro Chloric Acid Chemicals Are Supplied By The Contractor For Dosing And Cleaning Of Reverse Osmosis Plant ( Ro ) In Daily Basis Complete All As Specified And Directed 85 Micron Sediment Filter 20 X 4 Of Size Chemicals Are Supplied By The Contractor For Dosing And Cleaning Of Reverse Osmosis Plant ( Ro ) In Daily Basis Complete All As Specified And Directed 86 Carbon 1100 Silver Id Chemicals Are Supplied By The Contractor For Dosing And Cleaning Of Reverse Osmosis Plant ( Ro ) In Daily Basis Complete All As Specified And Directed 87 Multi Grade Media Filter ( Stone Gravels ) Are Supplied By The Contractor For Dosing And Cleaning Of Reverse Osmosis Plant ( Ro ) In Daily Basis Complete All As Specified And Directed 88 Repair / Rewinding And Servicing Of High Pressure Motor Pump Installed At 500 Lph Ro Plant, Including All Pvc Pipe Lines To Be Checking / Servicing Will Be Done And Broken Parts Of Pvc Pipe Will Be Replaced Complete All As Specified And Directednote : Pvc Pipe Rates Are Incuded In The Quoted Rates. 89 Dismantling, Aquaguard Ro Water Filter Servicing / Repair And Replacement Of Unserviceable Parts For Smooth Functioning Of System And Re-Fixing The Same To It Same Position With Necessary Fixing Arrangement Complete All As Directed At Site. Note:- 1.Servicing Of Aquaguard Ro Will Be Carried Out Twice In One Year As Per Directed 2.Rates Shall Be Included For Sediment Filter 90 Taking Down Carefully Alluminium / Copper Point Wiring Complete For Light, Fan, Socket Or Power Point Etc With Fittings Fixtures Such As Ceiling Rose, Holders, Electric Fittings, Switchs, Sockets, Aluminium Conductor Cable With And Incl Wooden Batten Or Fr Pvc Conduit And Its Accessories Such As Wooden Gutties, Rawl Plugs, Gi Screws, Aluminium Clips, Nails Etc Complete And Removing The Material From Site And Making Good The Disturbed Surface Of Wall / Floor / Ceiling Etc As Original I.E. Brick Work, Plastering, White Washing, Obd Etc As Required, Complete All As Specified And Directed. 91 Taking Down Carefully Unsv Main Switch And DbS Including Mcbs Of Any Size Make, Type And Capacity Omplete All As Specified And Directed. 92 M&L For Point Wiring ( Concealed Modular ) Complete For One Light Point / Fan Point / Exhaust Fan Point / Bell Point Controlled By One 1-Way Switch / Bell Push, With 1.5 Sq Mm ( Nominal Area ) Frls Pvc Insulated Un-Sheathed And Stranded Copper Conductor Cable Isi Marked And Pvc Concealed Conduit Isi Marked Of Size 20 Mm Dia Medium Grade And Pvc Conduit Fittings Such As Tees, Bends, Elbow, Reducers With And Including Frls Pvc Insulated Unsheathed 1.5 Sqmm Copper Earth Wire, Connecting To Common Earth Dolly With And Incl Metal Flush Box Of Suitable Size For Fixing Modular Switches / Sockets Etc And Making Good Surface By Wall Panelling Etc, Complete All As Directed. Make Of Wire : Kei / C&S / Finolex / Havells / Rr Kable / Polycab. Note : 1. The Cost Of Modular Type Metal Flush Boxes And Modular Accessories Like Inner / Outer Cover Plates Etc Is Deemed To Be Included In Quoted Rate. 2.The Cost Of Cutting Chases On Wall And Making Good Surface On Wall Are Deemed To Be Included In The Quoted Rate 93 All As Per Srl Item No. 86 Here-In-Before But For One Socket Outlet 3 Pin, 5 Amps On Independent Board. 94 All As Per Srl Item No. 86 Here-In-Before But For One Socket Outlet 3 Pin, 5 Amps On Same Board. 95 All As Per Srl Item No. 83 Here-In-Before But With Single Core Multistranded Cable Of Size 4.0 Sqmm For One 15 Amp Sockets Outlet On Independent Borad And Multistranded Insulated Copper Eart Continuity Conductor Of Size 4.0 Sqmm All As Specified And Directed By Engr-In-Charge 96 S & F In Replacementmodularswitch1way 6A , 1Module Size Complete All As Directed. 97 S & F In Replacementmodularswitch1way 16A , 2Module Size Complete All As Directed. 98 S & Fin Replacement Modular Bell Push Way 6A With 2 Module Size With Indicator Complete All As Directed. 99 S & Fin Replacement Modularsocket , 6 A , 5 Pin , 2Module Size Complete All As Directed. 100 S & F In Replacementmodularsocket , 6 A / 16 A , 5 Pin , 2Module Size Complete All As Directed. 101 S & F In Replacement Of Modular Type Fan Regulator 2 Module A / C 240 Volts.Note:Make Ofmodular Switches / Sockets And Other Accessories : Mk ( By Honeywell ) / Legrand ( Myrius ) / Havells ( Crabrtee ) 102 M&L Point Wiring ( Concealed Normal ) Complete With Single Core Frls Pvc Insulated, Unsheathed, Multi Stranded Copper Conductor Cables 1.5 Sqmm 1100 Volts Grade, With And Incl 1.5 Sqmm Frls Pvc Insulated, Unsheathed, Multi Stranded Copper Conductor Cables As Continuous Earth Wire Connected To Metallic Bodies Of Luminaries / Fans Etc At One End And To Common Earth Dolly At Other End, Complete Wiring Drawn Through & Pvc Casingand Cappingof 25 Mm And Above ( As Per Conductor Run ) Medium Grade, Isi Marked, Incl All Accessories & Fittings / Junction Boxes / Inspection Covers Etc, With And Incl Concealed Ms Sunken Box Of Suitable Size Flush With Wall Surface, Covered With & Incl 3 Mm Thick Bakelite, Laminated Hylem Sheet / Gang Box For Top Cover Suitable For Fixing Of Piano Type Switches / Sockets Etc, Complete All As Specified And Directed For One Light / Fan / Bell / Exhaust Fan Point Controlled By One No, 1-Way, 5 Amps Switch. ( Note :The Cost Of Ms Sunken Box With 3 Mm Thickbakelite, Laminated Hylem Sheet Top Cover Is Deemed To Be Included In Quoted Rate. ) Make Of Wire : Kei / C&S / Finolex / Havells / Rr Kable / Polycab 103 All As Per Items Ser No 96 Above But For One Socket Outlet 3 Pin, 5 Amps On Independent Board, Controlled By One No 5 Amp Switch. 104 All As Per Items Ser No 96 Above But For One Socket Outlet 3 Pin 5 Amps On The Same Board Controlled By One No 5 Amp Switch. 105 All As Per Srl Item No. 96 Here-In-Before But With 2.5 Sq Mmfrls Copper Wire With 1.5 Sqmm Frls Copper Earth Wire For Indpendent 15 Amp Point. 106 S&F In Replacement Of Switch Piano Type, Single Pole, One Way, 5 Amps, 230 Volts, Complete All As Specified And Directed. Make : Ssk / Havells ( Reo ) / Gold Medal 107 S&Fin Replacement Of Socket, Two-In-One, 5 Pin, 5 Amp, Universal Type, 230 Volts, Complete All As Specified And Directed. Make : Ssk / Havells ( Reo ) / Gold Medal 108 S&Fin Replacement Of Switch Piano Type, Single Pole, One Way, 15 Amps, 230 Volts, Complete All S Specified And Directed. Make : Ssk / Havells ( Reo ) / Gold Medal 109 S&Fin Replacement Of Socket, 6 Pin, 5 / 15Amp, Multipurpose Shutter Type, 230 Volts, Complete All As Specified And Directed. Make : Ssk / Havells ( Reo ) / Gold Medal 110 S&F In Replacement Of Resistance Type Fan Regulator A / C 240 Volts. Make : Gold Medal / Havells ( Reo ) / Ssk 111 S&Fin Replacement Of Bell Push, Flush Type 5 Amps, 230 Volts. Make : Ssk / Havells ( Reo ) / Gold Medal 112 S&Fin Replacement Of Electric Call Bell Ding Dong Ac 230 Volts Single Pole.Make : Gold Medal / Havells / Crompton 113 S&F Of Modular Ceiling Rose, Two To Three Terminals, Bakelite Body, 230 Volts, Complete All As Specified And Directed.Make : Havells / Ssk / Gold Medal 114 S&Fin Replacement Of Lamp Holder, Metal Cased, Bakelite Body, 230 Volts, With 9W Led Lamp Complete All As Specified And Directed. Make : Ssk / Havells ( Reo ) / Gold Medal 115 Supply And Fixing Led Light Fitting Mirror Type With Ligh Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete 116 Supply And Fixing Led Lights Fitting 1X 18W, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete 117 Supply And Fixing Led Emergency Batten Lights Fitting 10 Watt, 220V Ac With High Quality Polycarbonate And Translucent Serrated Milky White Diffuser To Get Glare Free, Smooth Light Distribution , Thermoplastic / Aluminium Housing Enhances Safety And Luminaire Is Pre-Wired With High Efficiency Electronic Driver And Led Lamp, Power Backup Of 3 To 4 Hr Including Up With Three Core Flexible Copper Conductor Cable Suitable Size Complete All As Specified And Directed. 118 Supply And Fixing Led Emergency Batten Lights Fitting 20 Watt, 220V Ac With High Quality Polycarbonate And Translucent Serrated Milky White Diffuser To Get Glare Free, Smooth Light Distribution , Thermoplastic / Aluminium Housing Enhances Safety And Luminaire Is Pre-Wired With High Efficiency Electronic Driver And Led Lamp, Power Backup Of 3 To 4 Hr Including Up With Three Core Flexible Copper Conductor Cable Suitable Size Complete All As Specified And Directed. 119 S&F Of Plastic Ventilating Fan 200 Mm Sweep Plastic Body Including Louvers With Cutting Chases On Brick Wall And Grounting With Nut Bolts On Aluminium Frame Complete All As Specified And Directed. Make : Crompton / Havells / Orient Note : Rates Are Deemed To Be Included For Cutting Chasing On Wall Or Window, Grouting With Nut Bolts Etc 120 S&F Of Exhaust Fan 300 Mm Sweep Steel Body Including Louvers With Cutting Chases On Brick Wall And Grounting With Nut Bolts On Aluminium Frame Complete All As Specified And Directed. Make : Crompton / Havells / Orient Note : Rates Are Deemed To Be Included For Cutting Chasing On Wall Or Window, Grouting With Nut Bolts Etc 121 S&F Of Distribution Board, Double Door, Made Out Of Crca Mild Steel Sheet Surface With Insulated Material Like Polyester Or With Epoxy Powder Coating And Ip 43 & Ik 09 Protection, Spn 08 Way ( Concealed Flush To Wall ) , 240 Volts With Bus Bar Rating 200 Amps, Dust And Vermin Proof, Suitable For Incorporation Of Mcb’S And Isolators Etc And Making All Necessary Connections, Duly Flush Of Wall Surface, Complete All As Specified And Directed.Make : Havells / Schneider Elect / Legrand / Abb / Hager 122 Supply And Fixing Double Doormanufacturer Mcb Db Tpn 04 Way Flush In Wall Comprising Of Sheet Metal Enclosure Powder Coated Fitted With Bus Bar 250 Amps 415 Volts. 123 S&Fof Mcb, C Curve Type, 25 Ka, 63 Amp To 100 Amp, Tpn With Over Load And Short Circuit Protection, Complete All As Directed. Make : Schneider Elect / Legrand / Abb / Havells 124 Supply And Fixing Mccb Fp 125 Amp, 25 Ka C Curve 415 Volts. 125 S&Fof Mcb, C Curve Type, 10 Ka, 63Amp, Spn With Over Load And Short Circuit Protection, Complete All As Directed. Make : Schneider Elect / Legrand / Abb / Havells 126 Supply And Fixing In Repair 240V, 10 Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Single Poles And Current Carrying Capacity 5 To 32 Amp, In The Mcb Db Complete With Connection. Make : Schneider Elect / Legrand / Abb / Havells 127 Taking Down Old Sub Main Wiring And M&L For Concealed Sub Main Wiring With 2 Run Of 16 Sqmm Frls, Pvc Insulated, Unsheathed And Stranded Copper Conductor Cable With And Incl 16 Sqmm ( Nominal Area ) Frls, Pvc Insulated, Unsheathed And Stranded Copper Conductor Cable As Earth Wire Connected With Thimble From Main Db To Sub Main Db, Drawn In To Separate Concealed Medium Grade, Isi Marked, Non Metallic Pvc Conduit 20 Mm Dia Size Incl All Conduit Accessories & Fittings / Junction Boxes / Inspection Covers Etc, With And Incl Cutting Chasing And Making Good Of Disturbed Surface Of Wall / Floor / Ceiling Etc As Original By Brick Work, Plastering, White Washing, Obd Etc As Required, Complete All As Directed. Note : Tworun Of 10 Sq.Mm. And One Run Of 10 Sq.Mm ( Earth Wire ) Cableincuding One Run Of Conduit Pipe Will Be Measured As One Length Including Making Good The Disturbed Surfaces. Make Of Wire : Finolex / Havells / Kei, Make Of Pvc Conduit : Finolex / Modi / Polycab. 128 All As Per Srl Item No. 39 Here-In-Before But With 2 Run Of 6.0 Sq Mm Frls Copper Wire With One Run 6 Sqmm Frls Copper Cable As Earth Wire. 129 All As Per Srl Item No. 39 Here-In-Before But With 2 Run Of 4.0 Sq Mm Frls Copper Wire With One Run 4 Sqmm Frls Copper Cable As Earth Wire. 130 M&L For Earthing With Galvanized Steel Earth Plate Electrode Of Size 600 X 600 X 6 Mm Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtr Below Of Normal Ground Level With Top Edge Of Earth Plate Should Not Less Than 1.5 Mtr Below Normal Ground Level And Connected To Galvanized Iron Earth Lead Wire Of Size 4 Mm Dia By Means Of Bolts, Nuts, Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No.3 Of Mes Ssr Part I Connecting To Earthing Test Point On Completion With And Including 15 Mm Bore Gi Light Grade Protection Pipe ( 7.5 Mtr Long ) For Earth Lead Gi Lead Wire 4Mm Dia ( 7.5 Mtr Long ) , Pcc Pit With Cover In Pcc 1:2:4 Type B-1 Reinforced With 8 Mm Dia Tor Bars @ 80Mm C / C, 20Mm Dia Medium Grade Watering Pipe With Funnel, Wire Mesh, Common Salt, Charcoal, Necessary Excavation And Earth Work, Complete All As Specified And Directed. 131 Servicing / Maintenance / Repair Of Dg Set Of 200Kva Installed At Dad Complex Forrepair / Replacment Of The Following Components All As Specified And Directed By Engr-In -Charge. ( A ) Checking Water Temperature Safety Control ( B ) Checking And Correcting Impeller Of Water Pump For Excess Play. ( C ) Checking And Correcting Turbocharger, Any Oil Leakage, Tightening Of Mounting Screws And Nutsetc. ( D ) Cleaning, Tightening All Electrical Connection Of Engine ( E ) Checking And Cleaning Of Generator Bushes ( Alternator ) Andcommutator ( F ) Cleaning Of Entire Engine. ( G ) Checking Exhaust And Inlet Manifold Bolts And Capscrew ( H ) Checking Engine Blow By ( H1 ) Cleaning Of Radiator Inside And Outside By Removing And Refixing After Cleaning. ( J ) Checking And Adjusting Injector And Valves. ( K ) Cleaning Fuel Inlet Connections And Screw, ( L ) Checking Of Oil. ( M ) Replacing Of Radiator Hoses Of Different Sizes With Clamps ( N ) Checking Of Vibration Damper 132 -Ditto- As Above Item No 43 But For 50 Kva Dg Set Note : Item Nos 43 & 44 : Any Following Item Required For Servicing / Preventive Maintenance Will Be Measured And Paid Separately Under Respective Items 133 Supply Onlyoil Filter Suitable For 200 Kva Dg Set 134 Supply Only Oil Filter Suitable For 50 Kva Dg Set 135 Supply Onlyk-Oil Super Suitable For 200 / 50 Kva Dg Set 136 Supply Only Fuel Filter Suitable For 200 / 50 Kva Dg Set 137 Supply Only Set Of Hose Suitable For 200 Kva Dg Set 138 Supply Onlyelement Suitable For 200 / 50 Kva Dg Set 139 Supply Only Element Air Cleaner Suitable For 200 / 50 Kva Dg Set 140 Supply Only V Fan Belt Suitable For Gen Set 200 / 50 Kva 141 Supply Only Coolant 142 Dismantling The Pt / Fi Pump Assembly, Repair / Overhauling / Calibrating In Authorised Lab Including Replacing Tornoutrings, Plunger, Damper Plate Gasket Etc. Including, Refixing, Reconnecting, Testing & Commissioning Complete As Specified And Directed. 143 Taking Down Ceiling Fan, Exhaust Fan, Wall Mounting Fan, Padestal Fan Etc Of Any Make, Type & Sweep Including Checking The Serviceabilty Of Ceiling Fan, Exhaust Fan, Wall Mounting Fan, Padestal Fan Etc In The Presence Of Mes Representative, Transporting The Same To Work Shop And Refixing The Same After Replacing Of Unserviceable Parts All As Directed By Engr-In-Charge.Note : Any Unsv Parts Reqd For Replacement Shall Be Measured And Paid Separately Under Respective Item Of Schedule As Supply Only. 144 Dismantling And Removing Old Burnt Copper Wire Winding Of Ceiling Fans Of Any Size & Sweep Of Any Make And Rewinding With New Enameled Super Copper Wire Of Existing Gauge As Per Old Copper Winding Incl Providing Insulation By Varnishing ( Golden ) , Cleaning, Oiling, Greasing Etc All As Specified And Directed By Engr-In-Charge. 145 All As Per Item No 48As Above But For Exhaust Fan Of Any Size & Sweep Of Any Make. Note : For Srl No 48 & 49 : The Super Enameled Winding Wire Is To Be Provided Shall Be Any One Make Of Devidayal / Usha / Chetak Of Appropriate Gauge As Directed By Engr-In-Charge. 146 Supply Only Capacitor For Ceiling Fans / Exhaust Fan / Cabin Fan / Table Fan Ofcapacity / Isi Marked2.5 Mfd. 147 All As Per Item Ser No 50 Above But For4.0 Mfd. 148 Supply Only Ball Bearing Suitable For Ceiling / Exhaust Fans Of Following Size Complete All As Specified And Directed By Engr-In-Chargefor Ball Bearing For Any Type Of Ceiling Fan. Make:- Skf / Nbc / Tata 149 Ball Bearing For Any Type Of Exhaust Fan, Make:- Skf / Nbc / Tata 150 Supply Only Ms Clamps ( Standard Size ) With Rubber Real With Ms Nut, Bolts, Check Nut & Split Pin Complete. 151 Supply Only Canopy For Ceiling Fans. Make:- Usha / Khaitan / Crompton 152 Supply Only Fan Blade For Ceiling Fan Of Any Type & Size. Make:- Usha / Khaitan / Crompton 153 Supply Only Fan Blade For Exhaust Fan Of Any Type & Size. 154 Supply And Fixing In Repair Single Pole And Neutral Enclosure With A Three Pin And Earth Plug And Socket Complete With One Single Mcb Sp 20 Amps. Make Legrand / C&S / Havells 155 Supply And Fix In Replacement Fornew Heating Element Including Rubber Ring, Washer, Holding Clamps And Nuts Of Following Capacity1.5 Kw Complete All As Specified & Directed. Make : Bajaj / Recold 156 All As Per Item Ser No 149 Above Bur For2 Kw 157 Supply And Fix In Replacement New Thermostat Of Temperature Variating Ranging From 25° Centigrade, Suitable For 15 / 25 Litre Capacity Geyser Complete All As Specified & Directed.Make : Bajaj / Recold 158 Supply Fix Inreplacement New Pvc Connection ( Heavy Duty ) Of 15 Mm Dia With Required Length With 2 Nos Of Brass, Chromium Plated Nuts Of Approved Make & Quality Complete All As Specified & Directed. 159 Supply And Fix In Replacement Safety Valve Isi Marked. 160 Supply And Fix In Replacementpressure Realizing Valve Fo Size 15 Mm Dia. 161 Supply And Fix In Replacement Geyser Bottom And Top Plate Suitable For Geyser Of Any Make, Size & Type Duly Painted 25 Ltrs Capacity Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fix In Replacement Of Indicator Lamp Assembly For Geyser Complete All As Specifed And Directed By Engr-In-Charge. 163 Maintenance, Servicing And Testing Of Split Type / Window Type Ac, Capacity Upto 2 Tons, Any Make, By Cleaning Cooling Coil, Condenser Fins, Blowing Of Dust From Machines / Air Filters Cleaning With Viniclean Solution Using Pressure Jet System With Water , Checking And Decarbonising All Electric System Oiling / Greasing Of Blower Motor, Checking And Removing Any Vibration And Leakage In The Equipment Including Checking / Repair To Inter Locking Device For Winter / Summer To Ensuretaking Down And Refixing In Position Complete All As Directed By Engineer-In-Charge.Note - Cost Of Minor Repair, Replacement Of Petty Items Such As Nuts, Bolts, Washers, Screws, Rubber Mounting Pads Of Compressor Etc, Transportation Of Equipment To Workshop And Back Is Deemed To Be Inclusive In The Unit Rates Quoted By The Contractor. 164 S&F, In Replacement, New Compressor For Split Type Ac 1.5 / 2 Ton Capacity Including Disconnecting, Opening Up, Taking Out Burnt Compressor By Cutting / Opening The Pipe Connections, Fixing In Position, Reassembling, Testing And Commissioning Including Gas & Oil Charging After Flushing The Line With Co2 Gas To Avoid Trapping The Water Vapour Ensuring Leak Proof System Complete All As Specified And Directed.Make: Shriram / Kirloskar / Voltas / Carrier / Whirlpool 165 M&L For Finding Out Leakage With The Pressure Testing Of The Condensor / Cooling Unit / Compressor Of Window Type / Split Type Ac Of 1.5 / 2 Toncap Including Dismantling The Same For Recharging With R-22 Gas Or As Per ManufacturerS Instruction And Stop Leakage By Brizing / Soldering Including Charging The Gas To Required Level And Testing The Ac For The Entire Satisfaction Of Eic. 166 S&Fnylon Type Filter Pad20 Micron For Window Type Ac Of Capacity Up To 2 Ton Including Taking Out Unserviceable Filter Pad Complete All As Specified And Directed. 167 S&F, In Replacement, Running Capacitor 5 Mfd 230 Volts For Blower Motor Complete All As Specified And Directed. Make : Keil / Asian / Tesla. 168 Supply And Fixing In Replacementstarting Capacitor Clip Type Of Cap. 80-100 Mfd, 440 Suitable For 1.5 / 2 Ton Capacity Window / Split Type Ac Complete All As Directed By Engineer-In-Charge Make- Kell / Tesla / Sharda / Escop 169 S&F In Replacement Ofrunning Capacitor, 36 / 45 / 50 Mfd Suitable For 1.5 / 2.0 Ton Capacity Window / Split Type Ac Of Approved Make. 170 S&F In Replacement Ofindoor Unit Complete Set Suitable For 2.0 Ton Capacity Make : Voltas / Whirlpool / Blue Star 171 Supply And Fixing In Replacement, External / Outdoor Unit Complete Including Compressor For Split Type Ac 2.0 Ton Capacity, Complete All As Specified And Directed 172 S&F, In Replacement, Starting Relay Suitable For Split Type Ac Of Capacity Up To 2 Ton Complete All As Specified And Directed. Make : Shriram / Renutrol 173 S&F, In Replacement, Condensing Fan Motor 1 / 8 Hp, Single Phase Suitable For Split Type Ac Up To 2 Ton Capacity Including Testing Complete All As Specified And Directed.Make: Khaitan Or Universal. 174 S&F, In Replacement, Power Circuit Breaker ( Pcb ) Kit For Split / Window Type Ac Complete All As Specified And Directed. 175 Supply, Fixing & Testing New Compressor For Water Cooler Of Capacity 60 / 120 Ltr, Including Disconnecting, Opening Up, Taking Out Burnt Compressor By Cutting / Opening The Pipe Connections, Fixing In Position, Reassembling, Testing And Commissioning Including Gas & Oil Charging After Ensuring Entire System Leak Proof Complete All As Specified And Directed. Make Kirloskar, Or Shriram 176 S&F, In Replacement, Thermostat Switch Suitable For Water Cooler, Any Capacity / Make Including Taking Down Unserviceable Thermostat Switch Complete All As Specified And Directed.Make: Shriram Or Ranutroll Or Indofoss. 177 S&F, In Replacement Capillary Filter Driver 2 Way Suitable For Water Cooler Including Taking Out Old Unserviceable Capillary Filter Complete All As Specified Anddirected 178 S&F In Replacement Drain Out Pipe Of Split Type Ac Complete All As Directed By Engineer-In-Charge. 179 S & F Single Phase Preventor With Accessories Suitable For Electric Motor 5-15 Hp Capacity With Necessary Electrical Connection By Using Proper Size Of Single Core Copper Wire Complete Incl Taking Down / Removing Old U / Swith Necessary Electrical Connection Complete As Directed. Make :Minilec Cat No-Vsp1 Ast / L &T / Simens 180 Supply And Fixing Analog Voltmeter 0-500Volt Rage Of Size 2.5X2.5, 3 Phase, 415 Voltsuitable Forthe Lt Panel Board Where Directed Including Taking Out Old Burnt Out Voltmeter Including Electrical Connection Withsuitable Size Of Copper Wire Complete All As Directed & Specified , Make:L&T / Ae / Meco Or Equiv 181 Supply And Fixing Digital Ammeter 0-150 Amps Of Size 4X4, Capacity , 3 Phase, 415 Volt With Operating Voltage 210 Vnos Suitable Forthe Lt Panel Board Where Directed Including Taking Out Old Burnt Out Ammeter Including Electrical Connection Withesuitable Size Of Copper Wire Complete All As Directed & Specified , Make:L&T / Schenider / Hpl , Cat No-Pamebrita 32 Or Equiv 182 Supply And Fixing Indicator Assy 3 Pcs Per Set Suitable For 230 Volt Matching With Exisisting One Forthe Lt Panel Board Where Directed Including Taking Out Old U / S Indicator Assy Including Electrical Connection Withesuitable Size Of Copper Wire Complete All As Directed & Specified , Make:Ae / Hpl Or Equiv 183 Prevantivemaintenance Andcleaning Of Filtersincluding Minor Replacement Of Defective Parts Of Air Coolerplants- 06Nos. Electrically Operatedinstalled At Dad Completeall As Specified And Directed Of The Following Capacities Note : ( I ) Servicing And Cleaning Of All Air Cooling Plant Will Be Carried Out One In Two Months As Per Directed By Engr-In-Charge. ( A ) Air Cooling Plant 4500 Cfm- 02 Nos. ( B ) Air Cooling Plant 12000 Cfm - 02 Nos. ( C ) Air Cooling Plant 9000 Cfm - 02 Nos. 184 M & L For Taking Down Unserviceable Electric Motor From 3 To 7.5 Hp Capacity From Foundation Dismantling Pump Motor For Servicing / Replacement Of Unserviceable Bearing, And Rewinding Of Motor Reassembling After Repair / Servicing Reinstall On Existing Location & Testing On Full Load Complete. 185 All As Per Item No 188 Above But Capacity Of Pump Motor 2 Hp For Air Cooling Plant 186 M & L For Taking Down Unserviceable Electric Motor Pump Set Upto 1.5 Hp Capacity From Foundation Dismantling Pump Motor For Servicing / Replacement Of Unserviceable Bearing, Gland Bush And Rewinding Of Motor Reassembling After Repair / Servicing Reinstall On Existing Location & Testing On Full Load Complete. 187 Material & Labour For Taking Down Unserviceable Mono Block Pump-Motor Of 15Hp Capacity From Foundation, Dismantle The Pump- Motor For Servicing / Replacement Of Unserviceable Bearing, Gland Bush, And Rewinding Of Motor, Reassemble After Repair / Servicing Reinstall On Existing Location & Testing On Full Load Complete After Completion. 188 M&L Pre Air Filter Wire Mesh For Fresh Airfor Air Cooling Unit Including Taking Down Unserviceable And As Per Directed. 189 M&L13 Mm Thick Nitriel Rubber Insulation With Glass Cloth And Ub Paint For Xpose Duct Including Taking Down Unserviceable As Per Dircted By Engr-In-Charge. 190 M&L For Filter Honey Bee Pad / Filter For Air Cooling System Installed Various Location At New Mh As Per Existing Including Taking Down Unserviceable. 191 Supply And Fixing Complete Canvas Clothes ( Zip Arrangement ) With S / S Body Frame Of Suitable Size Of Any Description As Per Existing And Directed By Engr-In-Charge 192 Taking Out Old Lt Under Ground Cable From Trenches / Floor / Road / Wall / Pipe / Pole Of Any Size And Description Incl Joint, Complete All As Specified And Directed By Engr-In-Charge. 193 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 16 Sqmm 4 Core 194 Supply, Laying And Testing Cable Xlpe Insulated , Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 95 Sqmm 3.5Core 195 Excavationin Trenches Nexc1.5 M Wideand Nexc1.5M In Depth And Getting Out In Soft / Disintegrated Rock Laying Of / Pipes Etcas Directed By By Engr-In-Charge. 196 Returning, Filling In Soft / Loose Soils Including Spreading, Levelling, Watering And Well Rammingin Layers Not Exceeding25 Cm Thick Each All Asdirected By Engineer-In Charge. 197 Removing Surplusexcavated Rock To A Distancenot Exc 50 Manddepositing Where Directedat A Level N.Exc. 1.5 M Above The Starting Point Complete All As Specified And Directed. 198 Supplying And Layingun-Reinforced Precast Concrete Cable Cover, Isi Marked , Class Lt, Type 1, Size 250Mm X 150Mm X 40Mmduly Embossed With Lt Cable 1100 Volts, Cable Size Insqmm Allas Specified And As Directed. 199 M &L For Dry Clean Fine River Sand As In Sand Cushioning To Undeground Cableincluding Punning Down Of Sand With Layer Of Sand 8 Cm Thick Before Laying Of Cable And 15 Cm After Laying Cable In Trenches All As Specified And Directed Note:- Punned Thickness Shall Only Be Measured And Paid. 200 S&F In Replacement Of Dol Starter In Sheet Steel Enclosure Type Mk-1 Suitable For Motor 3 Phase, 415 Volts 5 / 7.5 Hp Complete All As Specified And Directed By Engr-In-Charge. 201 Supply And Fixing Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Complete 202 S&F Of Gi Pipe Of 50 Mm Nominal Dia Light Grade Fixed To Poles With Clamps Nuts, Bolts And Washers Or Laid Under Road Crossing Or Fixed To Wallincluding Painting With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Paint Complete All As Directed. Note : The Cost Of Ms Clamp, Nut, Bolt, Washer And Gi Fittings Etc Shall Be Inclusive In The Item Rate. 203 S & F Street Light Poles Painting With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Paint Complete All As Directed. 204 Taking Up / Down Old Gi Tubing Connection Including Clearing ( From Trenches / Wall / Roof ) 50 Mm Bore Complete As Directed By Engr-In-Charge 205 Supply And Lay 50 Mm Bore Galvanised Steel Tubing Medium Grade With All Fittings And Fixtures Laid In Trench Or Ceiling Or Laying In Floors Complete All As Directed. 206 Supply And Fix Gun Metalgatevalve Heavy Duly Isi Marked With Iron Wheel Head Screwed Both Ends For Iron Pipes 50 Mm Bore Dia. 207 Supply, Laying, Testing And Commissioning Of Semi Conducting Compound Conductor Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured Xlpe Insulated Heavy Duty 11000 Volts Grade With Stranded Aluminium Conductor Of Size 95 Sqmm X 3 Core Confirming To Is 7098 Part-Ii, Suitable For Earthed System Complete All As Direcrted. Make : Havells / Finolex / Polycab / Keinote : 1. The End Termination Joint Shall Be Measured And Paid Separately Under Respective Items.2. Excavation, Earth Work, Sand Cushioning And Protection Cover Will Be Measured And Paid For Separately. 208 Supply Jointing And Testing Outdoor Type Cable End Termination Joint ( Heat Shrinkable ) Suitable For Aluminium Conductor Cable Of Size 95 Sqmm X 3 Core, 11000 Volts Grade, Complete All As Directed.Make : Raychem / Densons / M Seal 209 Dehydration / Filtration Of Transformer Oil Of Transformersof Various Capacities Installed At Dad Sub Station By Disconnecting Plants Electrically For Recirculation Existing Transformer Oil And Dielectric Strength Is Up Torange 40 Kv To 50Kv Note- :- ( I ) Test Result Will Be Recorded Before & After Filtration Of Oil. ( Ii ) Contractor Should Make His Own Arrangement For Oil Filtration Plant Including Transportation Complete. ( Iii ) Transformer Oil For Topping Up Will Be Measured And Paid In Relavant Item As Required. 210 Supply Andfilling Transformer Oil Of Good Quality For Topping Up Transformers 400 Kva Having Dielectric Strength Not Less Than 50 Kv , Flash Point Not Less Than 135 Degree C , Having Low Viscosity For Filling Or Replacing The Old Oil Complete All As Specified And Directed By Engr In Charge. Make - Servo / Power Oil / Hp 211 Supply, Installing And Testing 180Ah, 12V Maintanances Free Battery For Dg Set Make: Exide / Amaron Or Equivalent 212 Dismantling & Taking Down Of Air Break Gang Operated Switches Vertical / Horizontal Mounted Including Insulators And Operating Mechanism For Repair / Replacement Of Broken / Worn Out Components And Insulators Etc. 213 Supply & Install 11 Kv 3 Phase Gang Operated Air Break Switch With Drop Out Fuses Set ( Consisting 12 Nos Post Insulator ) 400 Amp Capacity, Vertical Mounting With Fixed And Moving Contacts Complete With Locking Arrangement And Fixing The Gang Operated Switch On Existing Two / Four Pole Structure Including Making All Jumper Connections With Insulated Leads Of Suitable Size With Line Tops Etc, All As Specifed And Directed.Make - Jaipuria / Rashtriya / Petco 214 Dismantling & Taking Down Insulator Any Type Any Size From Ht Pole. 215 M&L For Preparing Old Painted Steel Or Iron Surfaces Of Lt Panel Of Any Size And Description By Cleaning Dirt, Oil, Grease Etc, Removing The Old Paint, Rust By Scratching With Wire Brush / Emery Paper Etc, With And Incl Repairing / Refixing Of Existing Panel Doors With Hinges, By Using Of Gas Welding Or Fixing New Panel Door Of Same Size And Shape Made Of 2.0 Mm Thick Steel Sheel, As Per Site Requirement, With And Incl All Kind Of Machine Work I.E. Cutting, Bending, Pressing, Threading, Welding, Jointing Etc, After Disconnecting Lt Electric Connection And Apply Two Coat Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer Etc And Making All Electric Connections And Testing The Same, Complete All As Specified And Directed By Engr-In-Charge. 216 S&F In Repairs 3 Pole Power Contactor 1No+2Nc As Per Sample Of Makel & T, M / S Havells / Siemens / Standara / Legrandall As Specified And Directed. 217 S&F, In Replacement, Mccb, 415 Volts, 04 Pole, 630 Amps, 50 Ka, Ics = 100% Icu, With Thermal - Magnetic Release, Including Spreader Terminals, Phase Barriers, Complete All As Specified And Directed By Engr-In-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells 218 S&F, In Replacement, Mccb, 415 Volts, 04 Pole, 400 Amps, 36 Ka, Ics = 100% Icu, With Thermal - Magnetic Release, Including Spreader Terminals, Phase Barriers, Complete All As Specified And Directed By Engr-In-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells 219 S&F, In Replacement, Mccb, 415 Volts, 04 Pole, 250 Amps, 36 Ka, Ics = 100% Icu, With Thermal - Magnetic Release, Including Spreader Terminals, Phase Barriers, Complete All As Specified And Directed By Engr-In-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells 220 Supply And Fixing Security Light Termination Box, Weather Proof, Along With Connector For 3 Phases And Mcb Sp 6 Amps Incl 4 Aluminium Strip Bus Bar Mounted On Insulator Of Size 200X250x150mm. Make : Sintex / Hensel

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-12-2023
2 21-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-12-2023
3 26-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 54000.0 /-
Tender Value
INR 27 Lakhs /-

BOQ Items

Name of Work: SERVICING / MAINTENANCE / REPAIR OF EXTERNAL WATER SUPPLY LINES AND ALLIED WORKS AT MH JODHPUR AND CE OFFICE COMPLEX ANDSERVICING / MAINTENANCE / REPAIRING OF INTERNAL / EXTERNAL ELECTRIFICATION, SUMMER / WINTER APPLIANCES AND ALLIED WORKS AT DAD COMPLEX JODHPUR UNDER GE (ARMY) NO 2 JODHPUR
Sl. No. Item Description
1Taking up / down old DI/GI tubing connection of 20mm bore including clearing (from trenches/wall/roof) complete all as spsecified and as directed.
2All as per item No 01 above but for 25mm bore
3All as per item No 01 above but for 40mm bore
4All as per item No 01 above but for 50mm bore
5All as per item No 01 above but for80mm bore
6All as per item No 01 above but for 100mm bore
7All as per item No 01 above but for150mm bore
8Supply and laying for 20 mm bore galvanised steel tubing medium grade with all fittings and fixtures laid in trench or ceiling or laying in floors complete all as spsecified and as directed.
9All as per item No 2 above but 25 mm dia bore.
10All as per item No 2 above but 40 mm dia bore.
11All as per item No 2 above but 50 mm dia bore.
12All as per item No 2 above but 80 mm dia bore.
13All as per item No 2 above but 100 mm dia bore.
14Material and labour DI pipes of size 100mm dia with spigot and socket end centrifugally cast class "K- 9" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as spsecified and as directed..
15Material and labour DI pipes of size 150mm dia with spigot and socket end centrifugally cast class "K- 9" , in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as spsecified and as directed..
16Taking up/down old unserviceable gate valve/Ball Valve of size 20/25/40/50 mm bore complete all as spsecified and as directed.
17Supply and fix gun metalgatevalve heavy duly ISI marked with iron wheel head screwed both ends for iron pipes 20/25 mm bore dia complete all as spsecified and as directed.
18All as per item No 11 above but 40 mm size.
19All as per item No 11 above but 50 mm size.
20Taking up old unserviceable/defective cast iron non return valveand sluice valve flanged type of any make 80 to 150 mm bore dia complete all as spsecified and as directed.
21Supply and fix 80 mm dia bore cast iron non return valve flanged type heavy duty conforming to IS with rubber gasket joints including bolts, nuts, etc complete all as spsecified and as directed.
22All as per item No 15 above but 50 mm dia bore.
23Supply and fix cast iron sluice valve of size 150 mm dia flanged of class PN 1.6 confirming to IS with rubber gasket joints bolts nuts etc complete all as spsecified and as directed.
24All as per item No 17 above but sluice valve of size 100 mm dia.
25All as per item No 17 above but sluice valve of size 80 mm dia.
26Supply and fix in repairs cast ironfoot valve with leather flap scaling clamped on cast iron disc plates of size 100 mm dia complete all as spsecified and as directed.
27All as per item No 20 above but 80 mm dia.
28Taking down carefully spindle of cast iron sluice valve of size 80mm boredismantling parts and reassembling by replacement of newbrass spindle suitable for 80mm dia sluice valve, class PN 1.0, and refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as spsecified and as directed.
29M&L for Replacement of pressure gauge to read in IS/BSunit type 0 to 10 KG/cm2 and 0 to 150 psi including taking down old one complete all as spsecified and as directed.
30M&L for painting of sluice valve/NRV upto 80mm dia as per existing colour complete all as spsecified and as directed.
31M&L for painting of Valve Chambar plaster portion with cement base and steel portion with synthetic enamel paint of any size complete all as spsecified and as directed.
32S&F in replacement CI Butterfly valve 80 mm dia with lever operated CI Disc Nitrile/EPDM Rubber Lining test pressure PN-1.6 and ms nut bolt and washers and pair of rubber/fibers required for the work will be supplied by contractor for fixing in position complete all as directed.
33All as per item No-26 above but 100 mm dia
34All as per item No-26 above but 150 mm dia
35M&Lfor ruber gas ket joint/ tyton jointfor CI/DI pipe of size 80 mm bore complete all as spsecified and as directed.
36M&Lfor ruber gas ket joint/ tyton jointfor CI/DI pipe of size 100 mm bore complete all as spsecified and as directed.
37M&Lfor ruber gas ket joint/ tyton jointfor CI/DI pipe upto size 150 mm bore complete all as spsecified and as directed.
38M&L for construction of valve chembers with MS cover 3 mm thick of valve pit of size 1200x1200x1200 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame4ox40x6 mm and locking arrangement including painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as spsecified and as directed.
39M&L for construction of valve chembers with MS cover 3 mm thick of valve pit of size 900x900x900 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame4ox40x6 mm and locking arrangement including painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed
40M&L for construction of valve chembers with MS cover 3 mm thick of valve pit of size 600x600x600 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame40x40x6 mm and locking arrangement including painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed
41M&L P:C:C 1:2:4 Type B1 (20 MM graded stone agg) as in sub base 200 mm thick as per tank size including 15 mm thick cement plaster on top side of concrete surface including necessary form work for PCCcomplete all as specified and directed
42Supply and fixing PVC float valve (ball cock bady with epoxy coated aluminium rod & HD ball) of size 15/20 mm dia.including all fittings and taking down unserviceable complete all as spsecified and as directed.
43All as per item No 36 but 35/40 mm dia
44Excavation in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in soft and loose of soil and getting out complete all as specified and directed
45Returing filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as spsecified and as directed.
46Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as spsecified and as directed.
47Supply and fixing in replacement of Battery 12 volt 180 AH maintenance free complete all as spsecified and as directed.
48M & L for cutting the existing bituminous road/PCC road or path as per site requirment in 20 cm depth including refilling and consolidating the disturbed portion using PCC/bituminous for making good as existing surface complete all as spsecified and as directed.
49Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm Size means of bolts, nuts, check nuts and washers of galvanised iron or steel check nuts and washers of brass including necessary earth work, PCC chamber , CI cover with frame, funnel wire mesh, Earth lead protection pipe 40 mm dia, watering pipe 15 mm dia, 7.5 Meter Earth Lead etc all as shown in electrical plate No 5 in SSR Part-I and connected to earth test point/LT Panel/pump including testing on completion complete all as spsecified and as directed.
50Dewatering by using pump as required and , removal of mud and settled silt including scrapping of complete inner surface with the help of wire brush etc and therefore cleaning by water and bleaching of the following OH tank / UG sumps at MH Jodhpur / CE (Army) Jodhpur area and apply two coat of lime wash to all internal surface of wall/bottom/ceiling and Two coat of apex emulsion painting to all external surface including top surface and painting to oblitering labels shall be not less than 60x40 cm using black paint to match with existing dimension and writing particulars such as capacity of sump , date/ due date of cleaning etc useing white paint . Including disposal of mud silt etc obtained after cleaning up to 50 m away complete all as spsecified and as directed. :- (a)OH tank of capacity 5000 to 10000 GLNS (b)UG sump capacity 50000 to 600000 GLNS
51S&F in replacement Nut, bolt, washer of different size ISI marked
52S&F in replacement gland dori of different sizesISI marked
53Supply only greaseISI marked
54M&L for Disconnecting carefully the centrifugal pump set of capacity 15/20 HP and rewinding of copper winding of motor with super enamelled copper wire with existing size and gauge including varnishing, heating and testing, commissioning and reconnecting all as required to the entire satisfaction complete all as spsecified and as directed.
55M & L for repairing/overhauling ofthe following spit cage centrifugal pump set coupled with motor by replacing of unserviceable parts like bearings, sleeves bushes,bearings housing shaft, gunmetal impeller etcassembling the pump with new packing materials, nuts and bolts, washers and checking the alignment connectingup with delivery, suction pipes and testing for Pump set ofPump set of 15/20 HP Capacity complete all as specified and directed
56All as per srl item No 49 above but for Pump set of 7.5 HP Capacity.
57All as per srl item No 49 above but for Pump set ofPump set of 10 HP Capacity.
58M&L for Disconnecting carefully the sewage pump set of capacity 7.5 HP and rewinding of copper winding of motor with super enamelled copper wire with existing size and gauge including varnishing, heating and testing, commissioning and reconnecting all as required to the entire satisfaction complete all as specified and directed
59M&L for Disconnecting carefully the mono block pump set of capacity 5 HP to 8 HP and rewinding of copper winding of motor with super enamelled copper wire with existing size and gauge including varnishing, heating and testing, commissioning and reconnecting all as required to the entire satisfaction complete all as specified and directed
60Dismantling, removingpump set of capacity 5 HP Pump set and taking out electrical connection taking for Servicing of pump motor to workshop for machining, complete greasing. changing gland packing,minor parts like rubber/steel bushing, bearing ,nut bolts and re fixing the same to there same position with necessary fixing arrangement complete all as specified and directed Note- all required T&P will be included in above quated rates.
61All as per srl item No 56 but submersible pump set of 3 HP
62S&F in replacement Fully Automatic star delta motor starter Suitable for 15 HP , with single phase protectionAC-3, 415V,50 Hz, 3 Phase suitable for existing in Panel complete all as specified and directed
63S&F in replacement Fully Automatic star delta motor starter Suitable for 7.5HP, with single phase protection, AC-3, 415V,50 Hz, 3 Phase suitable for existing LT Panel complete all as specified and directed
64S&F in replacement Fully Automatic star delta motor starter Suitable for 10HP, with single phase protection, AC-3, 415V,50 Hz, 3 Phase suitable for existing LT Panel complete all as specified and directed
65M&L for Site Clearance complete all as specified and directed
66M&L 100 mm Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
67M&L for PCC (1:4:8) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed
68M&L for 80 mm thick factory made pre cast cement concrete rubber moulded laquer finish using chemical and admixure inter locking tiles having compressive strength not less than 400 kg/Sqcm,of shape and colour as approved by GE , laid over and including 25mm thickcompacted approved sand cushioned surface, joints filled by fine sand and compacting the top surfaces of paver blocks after laid etc of approved make complete all as specified and directed
69Supply and fix PVC insulated submersible cable 3 core flat copper conductor (including jointing material) size 6 Sqm 1100 Volt complete all as specified and directed
70M&L for repair of leakage of pipe line 80 to 150mm dia any size/type incl exacavation, dewatering, cleaning, repairing of pipe line leakage including all reqd items for repair at site and returning/filling and matching as per existing complete all as specified and directed.
71M&L for repair of leakage of pipe line 20 to 50 mm dia any size/type incl exacavation, dewatering, cleaning, repairing of pipe line leakage with reqd all accessories at site and returning and matching as per existing complete all as specified and directed.
72S&F PVC insulated 2.5 Sqmm unsheathed 3 core round copper conductor stranded cable wire 1100 V grade ISI Marked with suitable size of PVC conduit with proper fixing on wall / piller complete all as specified and directed
73Supply and fixing in replacement of rotational moulded polyethylene water storage tanks 500 lts (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed
74S& F in replacement single phase preventer for 3 phase motor fixed for star delta starter complete all as specified and directed
75S& F volt meter 0-500 volts square/round digital type incl taking down old one complete all as specified and directed
76S& F Amp meter 0-200 amps square/round digital type incl taking down old one complete all as specified and directed
77S&F in replacement 3 pole power contactor for starter incl taking down complete all as specified and directed
78M&L for spray painting of complete water pumpset of cap 7.5 HP to 20 HP with two coats of synthetic enameled paint of specified colour after preparation of surface and writing letters and numbers complete all as specified and directed
79S&F Bib taps of 20mm dia bore, cast copper alloy with clutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specifed and directed
80M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer complete all as specified and directed
81Dismantling, 500 LPH Reverse Osmosis Plant for servicing / repair and replacement of unserviceable parts for smooth functioning of system and re-fixing the same to it same position with necessary fixing arrangement of RO plant complete all as directed at site. Note:- Servicing of RO plant will be carried out twice in one year complete all as specified and directed
82Repair / Replacement of Membarane for 500 LPH RO Plant of 250 Ltr capacity complete all as directed at site. Make : Hydranautics, Dow, Aqua (Each plant having 2 Nos 250 Ltrs of Membarane)
83Antiscalant LiquidChemicals are supplied by the contractor for dosing and cleaning of Reverse Osmosis Plant (RO) in daily basis complete all as specified and directed
84Hydro chloric acid Chemicals are supplied by the contractor for dosing and cleaning of Reverse Osmosis Plant (RO) in daily basis complete all as specified and directed
85Micron Sediment Filter 20" x 4" of size Chemicals are supplied by the contractor for dosing and cleaning of Reverse Osmosis Plant (RO) in daily basis complete all as specified and directed
86Carbon 1100 Silver ID Chemicals are supplied by the contractor for dosing and cleaning of Reverse Osmosis Plant (RO) in daily basis complete all as specified and directed
87Multi grade media filter (Stone gravels)are supplied by the contractor for dosing and cleaning of Reverse Osmosis Plant (RO) in daily basis complete all as specified and directed
88Repair / rewinding and servicing of high pressure motor pump installed at 500 LPH RO plant, including all PVC pipe lines to be checking / servicing will be done and broken parts of PVC pipe will be replaced complete all as specified and directed Note : PVC pipe rates are incuded in the quoted rates.
89Dismantling, Aquaguard RO water filter servicing / repair and replacement of unserviceable parts for smooth functioning of system and re-fixing the same to it same position with necessary fixing arrangement complete all as directed at site. Note:- 1.Servicing of Aquaguard RO will be carried out twice in one year as per directed 2.Rates shall be included for sediment filter
90Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
91Taking down carefully UNSV main switch and DB"s including MCBs of any size make, type and capacity omplete all as specified and directed.
92M&L for point wiring (Concealed modular) complete for one light point / fan point / exhaust fan point / bell point controlled by one 1-way switch / bell push, with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers with and including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. Make of Wire : KEI / C&S / Finolex / Havells / RR Kable/Polycab. Note : 1. The cost of modular type Metal flush boxes and modular accessories like inner/outer cover plates etc is deemed to be included in quoted rate. 2.The cost of cutting chases on wall and making good surface on wall are deemed to be included in the quoted rate
93All as per srl item no. 86 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board.
94All as per srl item no. 86 here-in-before but for one socket outlet 3 pin, 5 Amps on same board.
95All as per srl item no. 83 here-in-before but with single core multistranded cable of size 4.0 sqmm for one 15 Amp sockets outlet on independent borad and multistranded insulated copper eart continuity conductor of size 4.0 sqmm all as specified and directed by Engr-in-Charge
96S & F in replacementModularswitch1way 6A , 1module size complete all as directed.
97S & F in replacementModularswitch1way 16A , 2module size complete all as directed.
98S & Fin replacement Modular Bell push way 6A with 2 module size with indicator complete all as directed.
99S & Fin replacement ModularSocket , 6 A , 5 Pin , 2module size complete all as directed.
100S & F in replacementModularSocket , 6 A / 16 A , 5 Pin , 2module size complete all as directed.
101S & F in replacement of modular type fan regulator 2 module A/C 240 Volts. Note:Make ofModular switches / sockets and other accessories : MK(by Honeywell) / Legrand (Myrius) / Havells (Crabrtee)
102M&L point wiring (Concealed Normal) complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casingand cappingof 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl concealed MS sunken box of suitable size flush with wall surface, covered with & incl 3 mm thick bakelite, laminated hylem sheet / Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for One light / fan / bell / exhaust fan point controlled by one no, 1-way, 5 Amps switch. (Note :The cost of MS sunken box with 3 mm thickbakelite, laminated hylem sheet top cover is deemed to be included in quoted rate.)Make of wire : KEI / C&S / Finolex / Havells / RR Kable/Polycab
103All as per items ser No 96 above but for one socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
104All as per items ser No 96 above but for one socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
105All as per srl item no. 96 here-in-before but with 2.5 sq mmFRLS copper wire with 1.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
106S&F in replacement of Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
107S&Fin replacement of Socket, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
108S&Fin replacement of Switch piano type, single pole, one way, 15 amps, 230 volts, complete all s specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
109S&Fin replacement of Socket, 6 pin, 5/15Amp, multipurpose shutter type, 230 volts, complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
110S&F in replacement of resistance type Fan regulator A/C 240 Volts. Make : Gold Medal / Havells (Reo) / SSK
111S&Fin replacement of Bell push, flush type 5 amps, 230 volts. Make : SSK / Havells (Reo) / Gold Medal
112S&Fin replacement of electric call bell ding dong AC 230 volts Single Pole. Make : Gold Medal / Havells / Crompton
113S&F of modular Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.Make : Havells / SSK / Gold Medal
114S&Fin replacement of Lamp holder, metal cased, bakelite body, 230 volts, with 9W LED lamp complete all as specified and directed. Make : SSK / Havells (Reo)/ Gold Medal
115Supply and fixing LED light fitting mirror type with ligh out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
116Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
117Supply and fixing LED emergency batten lights fitting 10 watt,220v AC with high quality polycarbonate and translucent serrated milky white diffuser to get glare free, smooth light distribution , thermoplastic/aluminium housing enhances safety and luminaire is pre-wired with high efficiency electronic driver and LED lamp, power backup of 3 to 4 hr including up with three core flexible copper conductor cable suitable size complete all as specified and directed.
118Supply and fixing LED emergency batten lights fitting 20 watt,220v AC with high quality polycarbonate and translucent serrated milky white diffuser to get glare free, smooth light distribution , thermoplastic/aluminium housing enhances safety and luminaire is pre-wired with high efficiency electronic driver and LED lamp, power backup of 3 to 4 hr including up with three core flexible copper conductor cable suitable size complete all as specified and directed.
119S&F of plastic ventilating fan 200 mm sweep plastic body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and directed. Make : Crompton / Havells / Orient Note : Rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc
120S&F of exhaust fan 300 mm sweep steel body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and directed. Make : Crompton / Havells / Orient Note : Rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc
121S&F of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 08 way (Concealed flush to wall), 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.Make : Havells / Schneider Elect / Legrand / ABB / Hager
122Supply and fixing double doormanufacturer MCB DB TPN 04 way flush in wall comprising of sheet metal enclosure powder coated fitted with bus bar 250 Amps 415 volts.
123S&Fof MCB, C Curve type, 25 kA, 63 Amp to 100 Amp, TPN with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / ABB / Havells
124Supply and fixing MCCB FP 125 Amp, 25 KA C Curve 415 volts.
125S&Fof MCB, C Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed. Make : Schneider Elect / Legrand / ABB / Havells
126Supply and fixing in repair 240V, 10 KA "C" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection. Make : Schneider Elect / Legrand / ABB / Havells
127Taking down old sub main wiring and M&L for concealed sub main wiring with 2 run of 16 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 16 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : Tworun of 10 Sq.mm. and one run of 10 Sq.mm (earth wire) cableincuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. Make of wire : Finolex/Havells/KEI, Make of PVC conduit : Finolex/Modi/Polycab.
128All as per srl item no. 39 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with one run 6 Sqmm FRLS copper cable as earth wire.
129All as per srl item no. 39 here-in-before but with 2 run of 4.0 sq mm FRLS copper wire with one run 4 Sqmm FRLS copper cable as earth wire.
130M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
131Servicing/maintenance/Repair of DG SET of 200KVA installed at DAD Complex forrepair/replacment of the following components all as specified and directed by Engr-in -charge.(a) Checking water temperature safety control (b) Checking and correcting impeller of water pump for excess play. (c) Checking and correcting turbocharger, any oil leakage,tightening of mounting screws and nutsetc.(d) Cleaning,tightening all electrical connection of engine (e) Checking and cleaning of generator bushes(Alternator) andcommutator(f) Cleaning of entire engine.(g) Checking exhaust and inlet manifold bolts and capscrew (h) Checking engine blow by(h1) Cleaning of radiator inside and outside by removing and refixing after cleaning. (j) Checking and adjusting injector and valves.(k) Cleaning fuel inlet connections and screw, (l) Checking of oil. (m) Replacing of radiator hoses of different sizes with clamps(n) Checking of vibration damper
132-Ditto- as above item No 43 but for 50 KVA DG Set Note : Item Nos 43 & 44 : Any following item required for servicing / preventive maintenance will be measured and paid separately under respective items
133Supply onlyOil filter suitable for 200 KVA DG set
134Supply only Oil filter suitable for 50 KVA DG set
135Supply onlyK-Oil Super suitable for 200 / 50 KVA DG set
136Supply only Fuel Filter suitable for 200 / 50 KVA DG set
137Supply only Set of hose suitable for 200 KVA DG set
138Supply onlyElement suitable for 200 / 50 KVA DG set
139Supply only Element air cleaner suitable for 200 / 50 KVA DG set
140Supply only V fan belt suitable for Gen Set 200 / 50 KVA
141Supply only Coolant
142Dismantling the PT/FI pump assembly, repair / overhauling / calibrating in authorised lab including replacing tornoutrings,plunger,damper plate gasket etc. including, refixing, reconnecting, testing & commissioning complete as specified and directed.
143Taking down ceiling fan, exhaust fan, wall mounting fan, Padestal fan etc of any make, type & sweep including checking the serviceabilty of ceiling fan, exhaust fan, wall mounting fan, Padestal fan etc in the presence of MES representative, transporting the same to work shop and refixing the same after replacing of unserviceable parts all as directed by Engr-In-Charge. Note : Any unsv parts reqd for replacement shall be measured and paid separately under respective item of Schedule as supply only.
144Dismantling and removing old burnt copper wire winding of ceiling fans of any size & sweep of any make and rewinding with new enameled super copper wire of existing gauge as per old copper winding incl providing insulation by varnishing (golden), cleaning, oiling, greasing etc all as specified and directed by Engr-in-Charge.
145All as per Item No 48as above but for Exhaust fan of any size & sweep of any make. Note : For Srl No 48 & 49 : The super enameled winding wire is to be provided shall be any one make of Devidayal / Usha / Chetak of appropriate gauge as directed by Engr-in-Charge.
146Supply only capacitor for ceiling fans / exhaust fan / Cabin fan / Table fan ofcapacity / ISI marked2.5 mfd.
147All as per item ser No 50 above but for4.0 mfd.
148Supply only ball bearing suitable for ceiling/exhaust fans of following size complete all as specified and directed by Engr-in-Chargefor Ball bearing for any type of ceiling fan. Make:- SKF/NBC/TATA
149Ball bearing for any type of exhaust fan, Make:- SKF/NBC/TATA
150Supply only MS clamps (Standard size) with rubber real with MS nut, bolts, check nut & split pin complete.
151Supply only canopy for ceiling fans. Make:- Usha/Khaitan/Crompton
152Supply only fan blade for ceiling fan of any type & size. Make:- Usha/Khaitan/Crompton
153Supply only fan blade for Exhaust fan of any type & size.
154Supply and fixing in repair single pole and neutral enclosure with a three pin and earth plug and socket complete with one single MCB SP 20 Amps. Make Legrand / C&S / Havells
155Supply and fix in replacement fornew heating element including rubber ring, washer, holding clamps and nuts of following capacity1.5 KW complete all as specified & directed. Make : Bajaj/Recold
156All as per item ser No 149 above bur for2 KW
157Supply and fix in replacement new thermostat of temperature variating ranging from 25° centigrade, suitable for 15/25 litre capacity geyser complete all as specified & directed.Make : Bajaj/Recold
158Supply fix inreplacement new PVC connection (heavy duty) of 15 mm dia with required length with 2 Nos of brass, chromium plated nuts of approved make & quality complete all as specified & directed.
159Supply and fix in replacement safety valve ISI marked.
160Supply and fix in replacementpressure realizing valve fo size 15 mm dia.
161Supply and fix in replacement geyser bottom and top plate suitable for geyser of any make, size & type duly painted 25 ltrs capacity complete all as specified and directed by Engr-in-charge.
162Supply and fix in replacement of indicator lamp assembly for geyser complete all as specifed and directed by Engr-in-charge.
163Maintenance, servicing and testing of split type/window type AC, capacity upto 2 Tons, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters cleaning with VINICLEAN solution using pressure jet system with water , checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensuretaking down and refixing in position complete all as directed by Engineer-in-Charge. Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor.
164S&F, in replacement, new compressor for split type AC 1.5/2 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed. Make: Shriram/ Kirloskar/Voltas/Carrier/Whirlpool
165M&L for finding out leakage with the pressure testing of the condensor/cooling unit/ compressor of window type/Split type AC of 1.5/2 Toncap including dismantling the same for recharging with R-22 gas or as per manufacturer"s instruction and stop leakage by brizing/soldering including charging the gas to required level and testing the AC for the entire satisfaction of EIC.
166S&Fnylon type filter pad20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed.
167S&F, in replacement, running capacitor 5 MFD 230 volts for blower motor complete all as specified and directed. Make : Keil / Asian /Tesla.
168Supply and fixing in replacementstarting capacitor clip type of cap. 80-100 MFD,440 suitable for 1.5/2 Ton capacity window/Split type AC complete all as directed by Engineer-in-Charge make- Kell/Tesla/Sharda/Escop
169S&F in replacement ofrunning capacitor, 36/45/50 MFD suitable for 1.5 / 2.0 Ton capacity window/split type AC of approved make.
170S&F in replacement ofindoor unit complete set suitable for 2.0 Ton capacity Make : Voltas / Whirlpool / Blue Star
171Supply and fixing in replacement, external/outdoor unit complete including compressor for split type AC 2.0 Ton capacity, complete all as specified and directed
172S&F, in replacement, starting relay suitable for split type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol
173S&F, in replacement, condensing fan motor 1/8 HP, single phase suitable for split type AC up to 2 ton capacity including testing complete all as specified and directed. Make: Khaitan or Universal.
174S&F, in replacement, power circuit breaker (PCB) kit for split/window type AC complete all as specified and directed.
175Supply, fixing & testing new compressor for water cooler of capacity 60/120 Ltr,including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make Kirloskar, or Shriram
176S&F, in replacement, thermostat switch suitable for water cooler, any capacity/make including taking down unserviceable thermostat switch complete all as specified and directed.MAKE: SHRIRAM or RANUTROLL or INDOFOSS.
177S&F, in replacement capillary filter driver 2 way suitable for water cooler including taking out old unserviceable capillary filter complete all as specified anddirected
178S&F in replacement drain out pipe of split type AC complete all as directed by Engineer-in-Charge.
179S & F single phase preventor with accessories suitable for electric motor 5-15 HP capacity with necessary electrical connection by using proper size of single core copper wire complete incl taking down/ removing old U/Swith necessary electrical connection complete as directed. make :Minilec Cat No-VSP1 AST/ L &T/Simens
180Supply and fixing Analog voltmeter 0-500volt rage of size 2.5x2.5",3 phase, 415 voltsuitable forthe LT Panel board where directed including taking out old burnt out Voltmeter including electrical connection withsuitable size of copper wire complete all as directed & specified , Make:L&T/ AE/MECO or Equiv
181Supply and fixing digital Ammeter 0-150 Amps of size 4x4", capacity ,3 phase, 415 volt with operating voltage 210 Vnos suitable forthe LT Panel board where directed including taking out old burnt out Ammeter including electrical connection withEsuitable size of copper wire complete all as directed & specified ,Make:L&T/ Schenider / HPL ,cat no-PAMEBRITA 32 or Equiv
182Supply and fixing Indicator assy 3 pcs per set suitable for 230 volt matching with exisisting one forthe LT Panel board where directed including taking out old U/S indicator assy including electrical connection withEsuitable size of copper wire complete all as directed & specified , Make:AE/ HPL or Equiv
183Prevantivemaintenance andcleaning of filtersincluding minor replacement of defective parts of Air coolerplants- 06Nos. electrically operatedinstalled at DAD completeall as specified and directed of the following capacities Note : (i) Servicing and cleaning of all Air cooling plant will be carried out one in two months as per directed by Engr-in-Charge. (a) Air cooling plant 4500 cfm- 02 Nos. (b) Air cooling plant 12000 cfm - 02 Nos. (c) Air cooling plant 9000 cfm - 02 Nos.
184M & L for taking down unserviceable Electric motor from 3 to 7.5 HP capacity from foundation dismantling pump motor for servicing/ replacement of unserviceable bearing,and rewinding of motor reassembling after repair/servicing reinstall on existing location & testing on full load complete.
185All as per item No 188 above but capacity of pump motor 2 HP for air cooling plant
186M & L for taking down unserviceable Electric motor pump set upto 1.5 HP capacity from foundation dismantling pump motor for servicing/ replacement of unserviceable bearing, gland bush and rewinding of motor reassembling after repair/servicing reinstall on existing location & testing on full load complete.
187Material & Labour for taking down unserviceable mono block pump-motor of 15HP capacity from foundation, dismantle the pump- motor for servicing / replacement of unserviceable bearing, gland bush, and rewinding of motor, reassemble after repair / servicing reinstall on existing location & testing on full load complete after completion.
188M&L Pre Air Filter wire mesh for fresh Airfor Air Cooling Unit including taking down unserviceable and as per directed.
189M&L13 mm thick Nitriel rubber insulation with glass cloth and UB paint for xpose duct including taking down unserviceable as per dircted by Engr-in-Charge.
190M&L for filter Honey Bee Pad/filter for air cooling system installed various location at New MH as per existing including taking down unserviceable.
191Supply and fixing Complete Canvas Clothes (Zip arrangement) with S/S body frame of suitable size of any description as per existing and directed by Engr-in-Charge
192Taking out old LT under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by Engr-in-Charge.
193Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core
194Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5Core
195Excavationin trenches nexc1.5 m wideand nexc1.5m in depth and getting out in soft /disintegrated rock laying of /pipes etcas directed by by Engr-in-Charge.
196Returning, filling in Soft/ loose soils including spreading, levelling, watering and well rammingin layers not exceeding25 cm thick each all asdirected by Engineer-in Charge.
197Removing surplusexcavated rock to a distancenot exc 50 manddepositing where directedat a level n.exc. 1.5 m above the starting point complete all as specified and directed.
198Supplying and layingun-reinforced precast concrete cable cover,ISI marked ,class LT, type 1, size 250mm x 150mm x 40mmduly embossed with "LT Cable 1100 Volts, cable size inSQMM" allas specified and as directed.
199M &L for dry clean fine river sand as in sand cushioning to undeground cableincluding punning down of sand with layer of sand 8 cm thick before laying of cable and 15 cm after laying cable in trenches all as specified and directed Note:- Punned thickness shall only be measured and paid.
200S&F in replacement of DOL starter in sheet steel enclosure type MK-1 suitable for motor 3 phase, 415 Volts 5/7.5 HP complete all as specified and directed by Engr-in-Charge.
201Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
202S&F of GI pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
203S & F Street light poles painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed.
204Taking up / down old GI tubing connection including clearing (from trenches/wall/roof) 50 mm bore complete as directed by Engr-in-Charge
205Supply and lay 50 mm bore galvanised steel tubing medium grade with all fittings and fixtures laid in trench or ceiling or laying in floors complete all as directed.
206Supply and fix gun metalgatevalve heavy duly ISI marked with iron wheel head screwed both ends for iron pipes 50 mm bore dia.
207Supply, laying, testing and commissioning of semi conducting compound conductor screened PVC bedded galvanized steel strip or wire armoured XLPE insulated heavy duty 11000 Volts grade with stranded aluminium conductor of size 95 Sqmm x 3 core confirming to IS 7098 Part-II, suitable for earthed system complete all as direcrted. Make : Havells/Finolex/Polycab/KEI Note : 1. The end termination joint shall be measured and paid separately under respective items.2. Excavation, earth work, sand cushioning and protection cover will be measured and paid for separately.
208Supply jointing and testing outdoor type cable end termination joint (Heat shrinkable) suitable for aluminium conductor cable of size 95 Sqmm x 3 Core, 11000 Volts grade, complete all as directed.Make : Raychem/Densons/M seal
209Dehydration/filtration of transformer oil of Transformersof various capacities installed at DAD Sub Station by disconnecting plants electrically for recirculation existing transformer oil and dielectric strength is up torange 40 KV to 50KV Note- :- (I) Test result will be recorded before & after filtration of oil.(ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.(iii)Transformer oil for topping up will be measured and paid in relavant item as required.
210Supply andFilling Transformer Oil of good quality for Topping Up transformers 400 KVA having dielectric strength not less than 50 KV , flash point not less than 135 degree C , having low viscosity for filling or replacing the old oil complete all as specified and directed by Engr in Charge. Make - Servo / Power Oil / HP
211Supply, installing and testing 180AH,12V maintanances free battery for DG set Make: Exide/Amaron or equivalent
212Dismantling & taking down of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc.
213Supply & install 11 KV 3 Phase Gang operated air break switch with drop out fuses set (consisting 12 Nos Post Insulator ) 400 amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, all as specifed and directed.Make - Jaipuria / Rashtriya / Petco
214Dismantling & taking down insulator any type any size from HT pole.
215M&L for preparing old painted steel or iron surfaces of LT Panel of any size and description by cleaning dirt, oil, grease etc, removing the old paint, rust by scratching with wire brush / emery paper etc, with and incl repairing/refixing of existing panel doors with hinges, by using of gas welding or fixing new panel door of same size and shape made of 2.0 mm thick steel sheel, as per site requirement, with and incl all kind of machine work i.e. cutting, bending, pressing, threading, welding, jointing etc, after disconnecting LT electric connection and apply two coat of synthetic enamel paint over one coat of red oxide primer etc and making all electric connections and testing the same, complete all as specified and directed by Engr-in-Charge.
216S&F in repairs 3 pole power contactor 1No+2NC as per sample of makeL & T, M/s Havells/Siemens/Standara / legrandall as specified and directed.
217S&F, in replacement, MCCB, 415 volts, 04 pole, 630 Amps, 50 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells
218S&F, in replacement, MCCB, 415 volts, 04 pole, 400 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells
219S&F, in replacement, MCCB, 415 volts, 04 pole, 250 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells
220Supply and fixing security light termination box, weather proof, along with connector for 3 phases and MCB SP 6 Amps incl 4 aluminium strip bus bar mounted on insulator of size 200x250x150mm. Make : Sintex / Hensel
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail