| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-12-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-12-2023 |
| Sl. No. | Item Description |
| 1 | Demolition of stone tiles/slabs of any description orthickness in floors , approns laidbedded and pointed in any mortar all as specified and directed by Engineer-in-charge. . |
| 2 | Demolition of brick work orstone/boulder masonry built in cement mortor or cement lime mortor incl all quoins,arches,pillars etc all as specified and directed by Engineer-in-charge. |
| 3 | Surface excavation n. exc. (not exceeding 30 cm deep and avg 15 cm deep) and getting out in sof/loose soil and removing the site all as specified and directed by Engineer-in-charge. |
| 4 | M&L for filling of Moorum/red bajri filling in floors or pavings laid in layers n exc 15cm thick, spread levelled and rammed including watering complete all as specified and directed. |
| 5 | M & L Hardcore of gauge n exc. 63 mm in floor or paving, laidin layers n exc. 15 cm thick spread levelled and rammed including watering and rolled to true surface with consolidated 8 to 10 ton cpacity power roller to well compacting complete all as specified and directed by Engineer-in-charge. |
| 6 | M&L 75 mm thick PCC type B-1, 1:2:4(20mm graded stone aggt) as in path, hard standing, parking floors etcincluding necsessary joint completeall as specified and directed by Engineer-in-charge.. |
| 7 | M&L coloured concrete parking paver cementtiles 400 x 400mm x 25mm thick set, jointed and pointed in neat slurry in floors with grey cement and pigments over and incl 15mm thick screed bed or bedding layer of motar for laying floor finishes in cement plaster 1:4completeall as specified and directed by Engineer-in-charge. |
| 8 | M&L forcement concrete inkerbs type B1, 1:2:4(20mm rounded or chamfered on edges graded aggregate) havingrounded or chamfered on edges including,excavation,pcc& necessary formwork all as specified and directed by Engineer-in-charge. |
| 9 | M&LFormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed by Engineer-in-charge. |
| 10 | M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed by Engineer-in-charge. |
| 11 | M&L for Reinforced cement concrete (nominal mix) Type A-1 1:1.5 :3 (using 20mm graded Aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed by Engineer-in-charge.. |
| 12 | M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape as reqd , incl crancking bending ,spirally for hooping columnshooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as in reinforcement of drain over slab all as specified and directed by Engineer-in-charge.. |
| 13 | All as per item No. 12 here in before but 5mm dia and over upto and including 10mm dia a sin stirrup, spacer and binders complete all as specified and directed |
| 14 | Dismantling steel work including door.gates, fencing complete all as specified and directed by Engineer-in-charge |
| 15 | Fixing only (Refixing) Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work all as specified and directed by Engineer-in-charge. |
| 16 | Excavating in post holes(or similar holes) each n exc 0.5cum , getting out, returnin , filling in and ramming earth or broken rubble mixed with earth arround, in layers not exceeding 25cm in soft/loose soil all as specified and directed by Engineer-in-charge. |
| 17 | M&L for walling of squared rubble stone masonary un coursed or brought up to course , well bonded , bedded and solidly hearted, built in CM 1:6 complete all as specified and directed by Engineer-in-charge |
| 18 | M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in copings including necessary form work complete all as specified and directed by Engineer-in-charge |
| 19 | M&L for flush pointing to squared rubble masonaryuncoursed or brought upto course CM 1:4 complete all as specified and directed by Engineer-in-charge |
| 20 | M&L preparing new surface on walls and applying 2 coats of cement paint over one coat of primer complete all as specified and directed by Engineer-in-charge. |
| 21 | M&L for preparation of old steel surfaces exc 10 cm in width or girth and applying 1 coats synthetic enamel paint complete all as specified and directed by Engineer-in-charge. |
| 22 | M&L PCC (1:4:8) type D-2 using 40mm graded stone agg as in fdn filling mass concrete complete all as specified and directed by Engineer-in-charge. |
| 23 | S& F joist,channels,angles , Box section,flat irons, or T section fixed independently ,with out coonecting plates etc including all necessary nut and bolts in Fe 410-w (Gde E-250) Quality A |
| 24 | M&L for preparation of new or previously untreated surfaces of any description , not otherwise described over 10 cm width or girth for gates or like painting with two coats of synthetic enamel over acoat of red oxide primer. |
| 25 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 26 | S&F Pre- painted galvatume aluminum zinc coating GI based plainsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 27 | Material and labour for 75mm thick sand filling under floors including watering and consolidation complete all as specified and directed by the Eng-in-Charge. |
| 28 | M & L RCC M20 type A1 (1:1:5:3) using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams plinth beams bases for coloumns, etc., basement slabs, under-reamed piles and mass concrete complete all as speciified and as directed |
| 29 | M & L RCC M20 type A1 (1:1:5:3) using 20mm graded stone aggregate as coloumns, pillers, piers, posts, struts complete all as speciified and as directed |
| 30 | M & L RCC M20 type A1 (1:1:5:3) using 20mm graded stone aggregate as beams, cantilevers, bressummers, lintels over 1.5m span complete all as speciified and as directed |
| 31 | M & L RCC M20 type A1 (1:1:5:3) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, dec slabs and in shelves and the likecomplete all as speciified and as directedNote: Re-inforcement shall be measured and paid separately. |
| 32 | M & L RCC M20 type A1 (1:1:5:3) (using 20mm graded stone aggregate) as in chajjas, etc complete all as speciified and as directedNote: Re-inforcement shall be measured and paid separately. |
| 33 | Formwork to sides of concrete foundation, footings, bases of columns, raft & raft beams, sides & soffits (if any) of foundation & similar works, vertical of to batter, rough finished surfaces of concrete flat complete all as specified and directed |
| 34 | Formwork to sides of pillars posts, struts, piers, columns and stanchoins, rough finished square surfaces of concrete complete all as specified and directed |
| 35 | Formwork to sides soffits of floor or roof beams, lintels, cantilevers etc, rough finished surfaces of concrete flat complete all as specified and directed |
| 36 | M & L for brick work with sub class \"B; brick straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed |
| 37 | M&L for 20 mm thick rendering inbrick or concrete surface in cement mortar (1:4)double layer over external surfaces complete all as directed (in two layer of 10mm each using WPC as per manufacturers instruction) |
| 38 | M&L for rendering 15 mm thick with CM 1:6 on other than fair face incl finishing even and smooth w/o using extra cement complete. |
| 39 | Supply only water proofing compound (integral) complete all as specified and directed. |
| 40 | M&L for mild steel rolled sections conforming to Fe - 290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. |
| 41 | M&L mild steel rolled sections conforming to Fe - 290 (Gde E-165) inRoof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc completed. |
| 42 | Supply and fix MS flat iron as in Bands, straps, supports or stays for hold fasts, clamps for eaves board/facia etc, conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 43 | Material and labour for 12mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, exc 15cm and n exc 22.5cm long completeall as specified and directed by the Engr-in-Charge. |
| 44 | S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock, strick plate, etc complete as specified, supplied and fixed.Size of frame Size of frame 105 x 60 mm including providing one shop coat of zinc chrome primer . |
| 45 | Supply & fix 30 mm thick Flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and fitted to chowkats.NOTE: All builder\"s hardware shall be measured and paid separately. |
| 46 | S&F steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded including one shop coat of Zinc Chrome primercomplete all as specified. |
| 47 | All as per item No. 46 above hereinbefore but without glazing bars for gauzed shutter including one shop coat of Zinc Chrome primer complete all as specified and directed. |
| 48 | S&F sheet glass in ordinary quality 3mm thck and glazing with oil putty and securing pins not exceeding 0.50sqm each pane complete all as specified and directed. |
| 49 | Supply and fix 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed by the Engr-in-Charge. |
| 50 | Supply and fix aluminium alloy anodised sliding door bolts 250 mm long with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section. |
| 51 | Supply & fix Aluminium handles, 150 mm size, cast type, anodised. |
| 52 | S&F of 100mm size mild steel butt hinges medium weight. |
| 53 | M &L Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 15mm thick screed bed with CM 1:6 complete . |
| 54 | All as per item No 53 here-in-before but as in skirting/dado over and including 10mm thick rendering in CM 1:4 as backing layer complete. |
| 55 | Materials and labour for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate)as in sub-base of floor over and including 50 micron polythene film laid completeall as specified and as directed by the Engr-in-Charge. |
| 56 | Material & labour for hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface using broken stone or boulders. |
| 57 | M&L for preparation of new plastered surfaces of walls and applying two coats of colour wash, over a primary coat of white wash complete |
| 58 | M&L preparing new surface on walls and applying 2 coats of cement paint over one coat of primer on external walls. |
| 59 | M & L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces exc 10cm width or girth over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed. |
| 60 | M&L for applyingthree coat of white washing including preparation of new or previously untreated surface of ceiling. |
| 61 | M&L for 75mm thick PCC type C-2 (1:3:6) using 40 mm graded agg in plinth protection path/hardstanding finished cement concrete surfaces fair and even all as directed by Engineer-in-Charge. |
| 62 | M&L for 5mm thick in CM 1:3 in ceiling finishing the surfaces even and smooth without using extra cement. |
| 63 | S&FFloor door stopper of aluminium alloy anodised,with rubber at bottom of required sizefixed in door with screws etc complete all as specified . |
| 64 | Material and labour for chequred cement concrete tiles 300x300x20-22mm thick set, jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed by Engr-in-charge. |
| 65 | M & L for 2 coat of plastic emulsion over a coat of primer after Complete removal of existing treatment on surfaces of any description over 10cm girth or width, not otherwise described |
| 66 | M & L for 150 mm dia asbestos cement socketed rain water pipes with cement joints complete all as specified and as directed by Engr-in-charge. |
| 67 | Material and labour for complete removal of existing treatment and applyingfor two coat of white wash on ceiling complete all as specifled and directed |
| 68 | Material and labour for complete removal of existing treatment and applyingfor two coat of white wash on walls complete all as specifled and directed |
| 69 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles. |
| 70 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the permises etc., complete all as specified and as directed by Engr-in-charge. |
| 71 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but n exc 4 sq. m each |
| 72 | Taking up or down 15 mm bore steel tubingand connections, including cleaning for refixing or removal to store |
| 73 | Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water, etc. |
| 74 | M &L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 including finishing even and smooth without extra cement complete all as specified and as directed. |
| 75 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level). |
| 76 | M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:4 complete all as specified and as directed by Engr-in-charge. |
| 77 | M&L Rendering 10mm thickfor laying wall finishes with cement mortar 1:3 complete all as specified and as directed by Engr-in-charge. |
| 78 | M&L for Joint free Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-charge. |
| 79 | M&L for Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed by Engr-in-charge. |
| 80 | Material and labour for preparation of new plastered surfaces and applying three coat of white wash on walls complete all as specifled and directed |
| 81 | S & F Glass shelf assemblycomplete all as specified and as directed by Engr-in-charge. |
| 82 | S & F stainless steel coat hooks, solid body, 200 to 250 mm length complete all as specified and as directed by Engr-in-charge. |
| 83 | Material and labour for two coat of synthetic enamel painting on old painted wood surfaces of any description, not otherwise described over 10cm width or girth including preparation complete all as specified and as directed by Engr-in-charge. |
| 84 | Material and labour for preparation of old painted surfaces by complete removal of existing treatment and application of two coat of synthetic enamel painting over a coat of pink primer on wood surfaces of any description, not otherwise described over 10cm width or girth including preparation complete all as specified and as directed by Engr-in-charge. |
| 85 | M&L for 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations/plain sheetside lap fixed with coach screw and washer in roof, wall etc. |
| 86 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 87 | Material and labour for preparation of new or untreated steel surfaces and application of two coat of synthetic enamel painting over one coat of red oxide primer of any description, not otherwise described over 10cm width or girth including preparation complete all as specified and as directed by Engr-in-charge. |
| 88 | Material and labour for preparation of new or untreated steel surfaces and application of two coat of synthetic enamel painting over one coat of red oxide primer of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint including preparation complete all as specified and as directed by Engr-in-charge. |
| 89 | M&L for Excavating soft/ loose soil in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 90 | Material and labour for plain cement concrete type C-2, 1:3:6 (Using 40mm graded stone aggregates) as in sub base complete all as specified and as directed by Engr-in-charge. |
| 91 | Material and labour for two coat of Aluminium painting on old painted steel surfaces of any description, not otherwise described over 10cm width or girth including preparation complete all as specified and as directed by Engr-in-charge. |
| 92 | Material and labour for two coat of Aluminium painting on old painted steel surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint including preparation complete all as specified and as directed by Engr-in-charge. |
| 93 | S & F in repair Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg, Aluminium die cast body and fixed complete all as specified and as directed by Engr-in-charge. |
| 94 | Material and labour for complete removal of existing treatment and applyingfor two coat of colour wash on walls complete all as specifled and directed |
| 95 | S & F 0.4- 0.8 sqm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specifled and directed |
| 96 | Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc. complete all as specified and as directed. |
| 97 | Supply and fix powder coated anodised sliding/hung type aluminium door, window and ventilator shutters (minimum thickness of powder coating 50 micron), without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2Nos) suitable handle (1 No), aluminium tower bolt 100 mm (1No)etc. complete all as specified and as directed |
| 98 | S&F 5.5 mm thickSheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 99 | Supply and fix for powder coated anodised aluminiumgrill of 8x 8mm bars size of opening 10cms size mesh with aluminium channel \"F\" angle 20x 15mm aluminium frame workcomplete all as specified and as directed |
| 100 | M & L clean sawn Second class hard-wood in scantlings repairs, to replace old anddecayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store |
| 101 | M& L for french polishing on surfaces of any description, width or girth including cleaning and preparing the surfaces including a coat of wood filter on new/old works with two or more coats complete all as specified and as directed by Engr- In- Charge. |
| 102 | Demolition of cement concrete ( unreinforced) in ground floors and paving n. exc 15 cm thick ( below & above ground level) and removal & rubish of Premises exc 250 m but n exc 500 m complete all as specified |
| 103 | Material and labour for chequred cement concrete tiles 300x300x20-22mm thick set, jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed by Engr-in-charge. |
| 104 | Material and labour for complete removal of existing treatment of walls and applying two coats of oil bound distemper white or tinted over a coat of chalk whitening primer complete all as specified and as directed by Engr-in-charge. |
| 105 | Material and labour for Point wiring with 1.5 sqmm (Nominal area) unsheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non metallic rigid PVC conduitof 20 mm dia concealed wiringthrough Wall/Ceiling/Flore along with FRLS 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly and including 2 mm thick terminal boxes MS sheet flush mounted with 3 mm thick laminated hylem sheet fixed with camium plated iron screwsfor mountling switches, socket, fan regulators etc complete for for One Light point controlled by one switch. and making good disturbed surfaces matching with existing paint complete all as specified and as directed. |
| 106 | Supply and fix high efficiency Wall mounted LED light fitting 4 feet white, 20W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old one and taken as credit complete all as specified and as directed. |
| 107 | S&F Ceiling rose three terminals/ PVC/ polycarbonate, isolated bodycomplete all as specified and as directed by Engr-in-Charge |
| 108 | S&F for Switch piano, flush type single pole , one way 5 amp as specified and as directed by Engr-in-Charge . |
| 109 | Material and labour for Sub main wiring with Two run single core 4 sqmm (for phase and neutral) and one run single core 4 sqmm (for earth wire) with multi stranded copper conductorPVC insulated unsheathed FRLS cable 1100 volts grade confirming to IS-694 continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia concealed wiring through wall/ceiling/floor/roof etc including conduit accessories including taking down old sub main wiring with PVC conduit and taken as credit complete all as specified and as directed.Notes: (i) The disturbed surfaces shall be made good with existing surface including finishes as applicale. (i) Two different color wires shall be used for phase and neutral . (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles .(iv) Three run of 2.5 Sqmm cable, and one run of PVC conduit will be measured as one unit. |
| 110 | Supply and fix for MCB SPN 230 V, 32 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-charge.Note : Including taking down old unserviceable. |
| 111 | Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed by Engr-in-chargeNote : Including taking down old unserviceable. |
| 112 | Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion |
| 113 | S&F DB for MCB SPN 4 waydouble door DB with 200 amps rated copper bus barin SS enclosure double door type having IP 43 and IK 09 protection Including taking down old u/s DB and MCB\"s all as specified and directed . Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule. |
| 114 | Excavation in trenches not exc 1.5m wide and n.exc1.5m depth of soft/loose soil for for foundation, laying of cables etc for shafts, wells, cesspits, manholes, pier holes etc and not exceeding 1.5m depth and getting out complete all as specified and as directed |
| 115 | Excavation in trenches each additional 1.5m or part thereof in depth beyond the first 1.5 mnot exc 1.5m wide and n.exc 1.5m depth of soft/loose soil for for foundation, laying of cables etc for shafts, wells, cesspits, manholes, pier holes etc and not exceeding 1.5m depth and getting out complete all as specified and as directed |
| 116 | Spreading riddled earthfor low thermal resistivity UG cable cushioning complete all as specified and directed |
| 117 | Supply and lay common burnt clay bricks of sub class \"B\", standard size for cable protection in trenches complete all as specified and as directed. |
| 118 | Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and as directed |
| 119 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed. |
| 120 | S&F LED Flood light fittings of 100 Watts made up of die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection including connection with street light feeder, testing complete all as specified and as directed by Engineer-in-Charge. |
| 121 | S&F LED Street light fittings of 60 Watts made up of die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection including connection with street light feeder, testing complete all as specified and as directed by Engineer-in-Charge. |
| 122 | S &F 19010 Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) |
| 123 | Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 16 sqmm 4 core, connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel / Street light boxes all as per site requirement , testingcomplete all as specified and directed. |
| 124 | S&F Pole junction box of size (300 x200 x 100) mm, IP 66, halogen free and weather proof for outdoor installation of street lights,with dimrail to termination Incl MCB SPN 20 ampsupply & fixing of M.S flat iron clamps of suitable size all as specified and as directed by Engineer-in-Charge. |
| 125 | S&F GI pipe 40 mm bore , medium grade, duly bend 1.2m long mounting bracket, fixing clamps bolts, nuts of suitable size for street light/ floodbracket etc complete all as specified and as directed by Engineer-in-Charge. |
| 126 | M & L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paintetc complete all as specified and as directed by Engineer-in-Charge. |
| 127 | S&F PVC medium grade conduit 20mm dia for drawing aluminium conductor cable between pole junction box and light fittings including fixing clamp made of 25X3mm GI strips and nut bolts (Minimum 3 clamps in each pole to be provided)etc including taking out old unserviceable conduit of any type and size complete all as specified and as directed by Engr In Charge.(For Street light) |
| 128 | Supply and fix1100 V grade heavy duty cable with PVC insulated Aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire and over all PVC sheathed 4 Sqmm3 corestranded conductor nominal cross section in service connection passing through PVC Conduit/GI pipe (from Junction Box to Street light/Flood light fitting) |
| 129 | Material and labour for cutting of bituminous road / floor for laying ofU/G cables/water linenot exceeding 1.5 meter wide and not exceeding 1.5meterdeep including refilling / with material and, watering well ramming / compacting and making good with PCC 1:3:6, 100mm thick complete all as specified anddirected by Eing-in-charge. Note :-PCCshall bemeasuredseparately. |
| 130 | M&L for laying 40 mm bore GI pipe, medium grade with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge. |
| 131 | M&L for PCC (1:4:8), type D-2, using 40 mm graded stone aggregateincluding necessary formwork for basement of poles etc complete all as specified and as directed . |
| 132 | M&L for PCC (1:3:6) type C-2,using 40mm graded aggregate as in foundation of poles /stay and filling of mass concrete including providing necessary form work for foundation of poles complete all as specified and as directed by the Engineer in charge |
| 133 | M&L for PCC (1:2:4), type B-2, using 20 mm graded stone aggregate as infoundation including rafts, footings, plinth beam,support blocks and mass concrete etc for Coping Work complete all as specified and directed |
| 134 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed |
| 135 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copperconductor wire drawn intoexistingconcealedconduit including provision of 1.5Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- |
| 136 | One light point controlled by one switch. |
| 137 | One fan point controlled by one switch. |
| 138 | One wall mounted/ Exhaust fan point controlled by one switch. |
| 139 | One 3 pin socket outlet 5 Amps, indipendentboardwith cables 1.5 Sqmm size. |
| 140 | All as per item ser no-135 above here in before but one 3 pin socket outlet 5/15 Amps, indipendentboardwith cables 4.0 Sqmm size. |
| 141 | Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copperconductor drawn into including PVC conduit /fixed on wall/roof/ceiling etc of size not less than 20 mm diaincluding provision of 1.5Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following |
| 142 | One light point controlled by one switch. |
| 143 | One fan point controlled by one switch. |
| 144 | All as per item ser no-136 above here in before but one 3 pin socket outlet 5/15 Amps, indipendentboardwith cables 4.0 Sqmm size. |
| 145 | M&L for sub main wiring for phase and neutral with PVC FRLS insulated unsheathed multi stranded along with earth wire FRLS PVC insulted copper conductor, single core cable in existingconcealedconduit of appropriate size as specified for the following sizes Note:- : 1. Cutting chases for concealed wiring shall be measured and paid seperately. 2. Rates are including taking down old unserviceable. |
| 146 | 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire |
| 147 | 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire |
| 148 | S&F for ceiling rose three terminals/ PVC/ polycarbonate, isolated body as specified and as directed |
| 149 | Supply and fixing in repair of GImetal flush box suitable for mounting moduler plate of following modules:- |
| 150 | 3 Module |
| 151 | 6 Module |
| 152 | 12 Module |
| 153 | Supply and fixingin repair of combined both frame and cover plates fixing on mounting boxes for following modules:- |
| 154 | Cover plate with frame,3 Module |
| 155 | Cover plate with frame,6 Module |
| 156 | Cover plate with frame, 12 Module |
| 157 | Supply and fixing in repair ofmodular switch one way 5/6 A white Active one module all as specified and as directed by the Engineer-in-Charge |
| 158 | Supply and fixing in repair ofmodular switch socket combination 16 A, 6 pin 3 module flush type Active white two module complete all as specified and as directed by the Engineer-in-Charge . |
| 159 | Supply and fixing in repair of socket 2M 6A-2/3 pin combined Active white all as specified and as directed by the Engineer-in-Charge. |
| 160 | Supply and fixing in repair ofmodular fan step regulator,120 W-2 module all as specified and as directed by the Engineer-in-Charge. |
| 161 | Supply and fix tube light batten prewired suitable for T8 LED Cat No SUB118 T8 LED including environmental friendly warmT8 LED tube not less than18W with 2100mlumen 4 ft including taking down old unserviceable fittings all as specified and as directed by Engr-in-Charge. |
| 162 | Supply and fix high efficiency wall mounted warm LED batten type not less than 10 Watt 2 ft LED light fitting and including taking down old unserviceable fittings all as specified and as directed by Engr-in-Charge . |
| 163 | Supply and fix surface mounted round down warm light 15 watts requiredr for Ceilingcomplete all as directed by Engr-in-Charge Note:- Including taking down the existing unserviceable fittings. |
| 164 | Supply and fix Surface/suspended mounted LED liner warm light 36 watt ,including taking down old unserviceable fittings all as specified and as directed by Engr-in-Charge. |
| 165 | M& L to fix Steam generator - Main PCB, Micro touch controller (Time & Temp digital display) , solinoid valve and heaters. Supply and fix Heating control system PCB for SAUNA, incl fix water line GI Fittings/UPVC fitting for installation, commisioning & TPT |
| 166 | Supply and fix heavy duty wall mounted fan 450 mm sweep, AC, single phase, 230/240 volts complete with push button switch control of 4 speed complete all as specified and as directed. |
| 167 | M&L for cutting chases on brick walls concrete surfaces not exc10cm girth and making good in cement mortar (1:3) the existing surfaceafter carryiing out the concealed wiring including necessary finishesall as directed. |
| 168 | Taking down ceiling fans from ceiling hook of any make and sweep by disconnecting complete for repairs, all as specified and as directed. |
| 169 | Taking down Exhaust fans from walls of any make and sweep by disconnecting complete for repairs, all as specified and as directed. |
| 170 | Hanging only ceiling fans after repairs to ceiling hook of any make and sweep by connecting with 3 core copper flexible round cable from ceiling rose to fan completeall as specified and as directed.Note:-Copper wire will be measured and paid separately as supply only under relevant items |
| 171 | Fixing only Exhaust fans after repairs/ fan of any make and sweep by connecting with 3 core copper flexible round cable from ceiling rose to fan completeall as specified and as directed.Note:-Copper wire will be measured and paid separately as supply only under relevant items |
| 172 | M&L for rewinding of burnt out fan motor with super enameled copper winding wire of suitable gauge/size including necessary tapping, varnishing etc, including taking down burnt copper winding and necessary transportation to workshop and back and testing incl painting of two coat deco paint before refixing complete all as directed of the following :- |
| 173 | Ceiling fan 1200/1400mm sweep |
| 174 | Exhaust fan 300mm sweep. |
| 175 | Supply and fix Air cooled split unit Air Conditioner electric driven single phase of capacity 1.5 TR with copper condenser coil and evaportor coil, green gas R32 or 407C, mounting stand will all accessorries 5 star rated inverter AC all as specified and as directed.Note: The rate quoted be the tenderer shall inclusive of the following provisons:-(i) UPVC drain pipe not less than 20mm dia from indoor unit (any floor) to upto ground level/near to drain to be fixed with proper size base plate with clamps complete.(ii) Copper pipe 20mm dia and 15 mm dia with 20SWG thickness refrigerant piping with 19mm thick closed cell rubber nitrile, class \"O\" - arm-flex insulation and including connection and extra length of copper wire and tubing as per site requirment to be included in the quoted rate.(iii) GI powder coated brackets 16 SWG of reuired size: 02 Nos including grouting with suitable size fastners for fixing of outdoor units as per site requirment.(iv) If any extra length of suction and delivery Copper pipes, drainage pipe and connection flexible cable (4 sp mm 3 core) is required at site up to 10 mtr.(v) After completion of installation of ACs, the MES No and SM stickers are to be pasted over the indoor and outdoor units of AC as per direction of Engr-in-charge. |
| 176 | Supply & installation Voltage Stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 90 Volt to 300 volt with output voltage stablized at 230 volt with accuracy +/- 2.5 % and capacity 4 KVA complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy