Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #40765408

Tender For Exterior Painting Work Of Laboratory Building And Other Campus Development Works At Centre Of Plasma Physics-Institute For Plasma Research , Nazirakhat, Sonapur-782402

Issued by Boards / Undertakings / PSU · sonapur, Assam
Tender Value
22.43 Lakhs
Estimated cost
Bid Submission
11 Dec 2023
0 days left
EMD
44900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sonapur → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Exterior Painting Work Of Laboratory Building And Other Campus Development Works At Centre Of Plasma Physics-Institute For Plasma Research , Nazirakhat, Sonapur-782402

BOQ

Name of Work: Exterior Painting works of Laboratory Building and Miscellaneous Civil Works at CPP-IPR, Nazirakhat , Sonapur-782402
Sl. No. Item Description
1Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
2Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead as per direction of Engineer-in-charge.: Of area 3 sq. metres and below
3Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
4Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick
512 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
615 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)
7Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete as per direction of Engineer-in-Charge.
8Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per direction of Engineer-in-Charge.
9Finishing walls with Acrylic Smooth exterior paint of required shade:(Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) complete as per direction of Engineer-in-Charge.
10Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade complete as per direction of Engineer-in-Charge. : Two or more coats on new work
11Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture complete as per direction of Engineer-in-Charge.
12Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface as per direction of Engineer-in-charge. :Water thinnable cement primer
13Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work as per direction of Engineer-in-charge.
14Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture as per direction of Engineer-in-charge.
15Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry complete as per direction of Engineer-in-Charge.
16Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior/exterior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
17Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
18Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire complete as per direction of Engineer-in-Charge.
19Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete as per direction of Engineer-in-Charge.. 0.45 mm thick with zinc coating
20Renewing glass panes, with putty and nails wherever necessaryincluding racking out the old putty. Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) complete in all respect as per the direction of Engineer-in-Charge.
21Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality complete as per direction of Engineer-in-Charge. 1.0 mm thick
22Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
23Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
24Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer as per direction of Engineer-in-charge. Frame size 65 x 150 mm
25Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick
26Providing and fixing bright finished brass butt hinges with necessary screws etc. complete as per direction of Engineer-in-charge.:125x85x5.5 mm (heavy type)
27Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete as per direction of Engineer-in-charge.:200x10 mm
28Providing and fixing bright finished brass handles with screws etc. complete as per direction of Engineer-in-charge.: 125 mm
29Providing and fixing bright finished brass door latch with necessary screws etc. complete as per direction of Engineer-in-charge. 300x16x5 mm
30Providing and fixing heavy duty hydraulic door closer withtubular body type universal (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 70 kg ), with necessary accessories and screws etc. complete as per direction of Engineer-in-charge..
31Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete as per direction of Engineer-in-charge.
32Providing and fixing 5 mm glass mirrorwith 40 mm long screws, rawl plugs etc complete as per direction of Engineer-in-charge..
33Supplying and fixing of new Cat-6 LAN cable (wherever required) &Re- routing of existing lan cables with 25 mm PVC Casing capping around the lab building complete as per direction of Engineer-in-charge. Entangled wires are to be re-arranged/removed as per requirement.
34Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
35Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
36Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
37Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
38Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
39Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required5/6 A switch
40Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required15/16 A switch
41Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required3 pin 5/6 A socket outlet
42Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required6 pin 15/16 A socket outlet
43Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
44Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
45Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
46Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
47Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
48Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
4920 mm PVC junction box, two way
50Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
51Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
52Supply and fixing single pole blanking plate in the existing MCB DB complete etc. as required
53Supply and fixing following rating, double pole, 240V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required, as required63A
54Aluminium lugs for 6 sq. mm cable
55Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.100W
56Supplying and fixing Waterproof Die-Cast Aluminium Outdoor Pillar Light capable of operating at line voltage ranging from 140-270 V AC, 50 Hz. IP55/65 rated, providing excellent resistance against corrosion and rust, ensuring a long service life. It is constructed using preferred materials for outdoor lighting, presenting a modern minimalist design suitable for garden pillars. Shall be complete with all necessary accessories required for proper working of fixture including connectors etc. as required.
57Supplying and fixing 12W LED Waterproof Exterior Wall Light capable of operating at line voltage ranging from 140-270 V AC, 50 Hz. IP55/65 rated, providing excellent resistance against corrosion and rust, ensuring a long service life. It is constructed using preferred materials for outdoor lighting, presenting a modern minimalist design suitable for garden lighting. Shall be complete with all necessary accessories required for proper working of fixture including connectors etc. as required.
58Supplying and fixing 5W LED Waterproof Pathway Light capable of operating at line voltage ranging from 140-270 V AC, 50 Hz. IP55/65 rated, providing excellent resistance against corrosion and rust, ensuring a long service life. It is constructed using preferred materials for outdoor lighting, presenting a modern minimalist design suitable for garden steps lighting. Shall be complete with all necessary accessories required for proper working of fixture including connectors etc. as required.
59Supplying and fixing LED Waterproof Bollard Garden Light capable of operating at line voltage ranging from 140-270 V AC, 50 Hz. IP65 rated, providing excellent resistance against corrosion and rust, ensuring a long service life. It is constructed using preferred materials for outdoor lighting, presenting a modern minimalist design suitable for garden lighting. Shall be complete with all necessary accessories required for proper working of fixture including connectors etc. as required.

AI Tender Summary

OUR REF NO 40765408
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 22.43 Lakhs
LAST DATE 11-12-2023
Authority
Authority Name Institute For Plasma Research
Work Description Exterior Painting Work Of Laboratory Building And Other Campus Development Works At Centre Of Plasma Physics-Institute For Plasma Research , Nazirakhat, Sonapur-782402
Basic Detail
Tender No CPP-IPR/TN/CES/C/23-24/06
Bidding Type Tender
Location
City sonapur
State Assam
Key Dates
Publish Date 22 Nov 2023
Submission Date 11 Dec 2023
Open Date 13 Dec 2023
Finance
Tender Value 22.43 Lakhs
Tender Fee Ref. Documents
EMD 44900
Exemption Not Available
Document List
9c467581-e969-4d6f-8cb4-2608299767fe.html
BOQ_822153.xls
technicalbidexteriorpaint.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 22, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 11, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 13, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9c467581-e969-4d6f-8cb4-2608299767fe.html

xls

BOQ_822153.xls

pdf

technicalbidexteriorpaint.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders