| 1 | Dismantling of old Exisiting plaster I/C disposal ofrefuse as directed by Engineer-in-charge. PWD- 706 |
| 2 | Dismentling of old Door or windows i/cchaukhats with hold fast I/C stacking of material asa directed be the eng.-in-charge. PWD - 703 |
| 3 | Dismantling of Reinforced cement concrete or reinforcrd brick work including stacking of material as directed by Engineer-in-charge.Si no-696 |
| 4 | Dismantling brick work or stone work in lime or cement mortar & I/C stacking of material asa directed be the eng.-in-charge.Si no-PWD - 696 |
| 5 | Dismantling cement concrete or brick work or granolithic floors I/C base conc. All comp. of work.Si no-697. |
| 6 | M-150 class brick work (1:6) with cement & fine sand mortar in sub-structure foundation plinth I/c all comp of work ………. As per si no 303+309+310 |
| 7 | M-150 class brick work (1:6) with cement & fine sand mortar in sub-structure foundation plinth I/c all comp of work ………. As per si no 303+309+310 |
| 8 | M-150 class brick work (1:6) with cement & fine sand mortar in sup-structure foundation plinth I/c all comp of work ………. As per si no 303+309+310 |
| 9 | R.C.C. (1:1.5:3) with cement ,approved coarse sand &2 cm gauge stone girt for BeamSI no-284(A) |
| 10 | R.C.C. (1:1.5:3) with cement ,approved coarse sand & 2 cm gauge stone girt forSlabSI no-289 |
| 11 | M.S. item work such as R.C.C. Completion of work as per S.I. No. 504 |
| 12 | 12 mm thick cement plaster (1:6) cement & fine sand on fair side of wall i/c propercompletion of work. PWD LKO - 13.4.2 |
| 13 | 12 mm thick plaster (1:6) Cement &finesandmortar on outer roughside wallI/C all CompletionPWD LKO - 13.5.2 |
| 14 | S/F 4\" Dia Rain water conduct Pipes I/C all material, labour T & P. etc.Si no-730a |
| 15 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge PWD - 10.14.1 |
| 16 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. .Providing & fixing of hold fasts. PWD - 502 |
| 17 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.. Providing & fixing of door / windows grill. PWD -502 b |
| 18 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. Z-Section steel windows (openable) PWD -502 c |
| 19 | Fixing of Door, windows/ventilators chaukhats in position. Door Chaukhats |
| 20 | Fixing of Door, windows/ventilators chaukhats in position. Windows Chaukhats |
| 21 | Fixing of Door, windows/ventilators chaukhats in position. Ventilators Chaukhats |
| 22 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (Rates Without Gst and labour Cess) . D.S.R. 9.20.1 |
| 23 | Fixing panes of glass with equal or equivalent I.S.I. marked quqlity putty, brads and springs and including supply of all materials and labour etc complete.si no-730 N.I c |
| 24 | P/ Fixing Galvanized mosquios proof heavy qualilty jali S.S wire gauge i/c all comp. of work. 9.51.1 |
| 25 | 4cm Thick and cement Concrete consisting of 1 part cement and 2 part approve Coarse sand and 4 parts approved 13mm(1/2inch) graded stone grit and including water proofing material as ordered by the engineer-in-charge in the proportion as specified by the manufacturer. PWD - 470a |
| 26 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .DSR - 9.96.2 |
| 27 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete 250x10mmDSR 9.97.2 |
| 28 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete 200x10mm DSR 9.97.3 |
| 29 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm D.S.R. -9.165.1 |
| 30 | Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. DSR - 14.34 |
| 31 | Supply and fixing 8 mm thick ivory light shaded vitrefied tiles 600x600mm size in flooring and skirting eath 1:3 cement and coarse sand i/c all comp. of work.PWD -N.I. 5 |
| 32 | P/ Laying ( Brick coba ) 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement & coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water proofing compound filled gaps of coba & top of coba mortar i/c all comp. of work.Si no-548 (N.Item) |
| 33 | Laying of 25mm thick Kota stone of size 45x45 cm and above flooring over previously prepared base with 2cm thick 1:3 cement mixed with pigment required for matching the shade of floor as per the direction of EIC i/c all comp. of work.N.I.-3 |
| 34 | Mild steel or Iron work in heavy sizes such as trusses,builtup gates,door frames,roof work etc.PWD - 504 |
| 35 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. |
| 36 | Supply & Fixing 80 mm thick Precast cement concrete I-Shape interlocking paver block a with top layer of minimum 8mm thickness having plan dimension 200x(160+120mm) of O.P. cement, Smooth high gloss finish, skid reditant. manufactured from rubber moulds through vibro-compression machanism. The compressive strength of concrere paver block shall not be less than 30MPA (M-30) and wight 5kg per no confirming to IS; 15658-2006 with a 4 cm thick layer of fine sand including cost of material, labour, T & P TAXES etc requried for proper completion of the work as directed by Enginner-in-charge.(1) Grey color |
| 37 | SANITARY FIXTURES - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 17.1.1 |
| 38 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter 12.41.2 |
| 39 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm12.43.2 |
| 40 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 90 mm O.D. NEW |
| 41 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 110 mm O.D. NEW |
| 42 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. NEW |
| 43 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 90 mm NEW |
| 44 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735 Size 110 mm NEW |
| 45 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735.Size 90x90x90 mm NEW |
| 46 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735 Size 110x110x110 mmNEW |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work) Exposed on wall20mm dia nominal outer dia pipes. 18.7.2 |
| 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(internal work) Exposed on wall 25mm dia nominal outer dia pipes. 18.7.3 |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Eng.in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes 18.8.1 |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Eng.in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes 18.8.2 |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Eng.in Charge. Concealed work including cutting chases and making good the walls etc. 25mm dia nominal outer dia pipes 18.8.3 |
| 52 | Providing & fixing CP brass bib cock of approved quality conforming to IS 893115mm nominal bore 18.49.1 |
| 53 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore 18.51.1 |
| 54 | Providing and fixing gun metal gate valve with wheel of approved quality.. 25 mm dia nominal bore 18.17.1 |
| 55 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore 18.17.2 |
| 56 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 18.48 |
| 57 | Septic Tank(Size :- L = 5.0 M. W = 2.00M Total D =3.00M) Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth PWD 251 |
| 58 | Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth In all kind of soil upto 1.5m to 3.0m. Depth PWD 251 |
| 59 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20 mm nominal size) 279 |
| 60 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) PWD 307a |
| 61 | Reinforced cement concrete work in slab with 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stoneaggregate 20mm normal size). 284a |
| 62 | Reinforcement for R.C.C. work including, straightening, cutting bending binding and placing in position complete. 504 |
| 63 | 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 course sand) 13.5.1. |
| 64 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.19.15.1 |
| 65 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. 7087 |
| 66 | Providing & fixing 75mm dia vent pipes. 17.35.2.1 |
| 67 | Providing & fixing of 75mm dia cast iron terminal guard. 17.56.2.1 |
| 68 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.. M.D. -10- Circular shape 500mm internal diameter 19.19.2.2 |
| 69 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.. M.D. -2.5- Circular shape 450mm internal diameter 19.19.1.3 |
| 70 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 19.32.1 |
| 71 | Electrification - Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash 138( C) +187(A) |
| 72 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitwith modular typeswitch, G.P. Box & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash.140( C) +187(A) |
| 73 | Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & socket etc, complete in all respect including matching colour wash.141( C) +187(C) |
| 74 | Supplyfixingand concealing of25mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. ( T.V. /Telephone)149(A) |
| 75 | Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect.1307(C) |
| 76 | Supply & wiring of submains with two number4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect.221(C) |
| 77 | Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copperearth contunity wire including colour wash etc. complete in all respects. 222(C) |
| 78 | Supply and wiring of submain 2 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in25mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 6.0 Sqmm FRLSH PVC Multistand copperearth contunity wire including colour wash etc. complete in all respects. 223(C) |
| 79 | Supply and wiring of submain with 4 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 4 sq. mm FRLSH PVC insulated multistrand copper earth contunity wire drawn inside the conduitcomplete in all respect.277© |
| 80 | Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects.278(C) |
| 81 | Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required. 412Cat. A |
| 82 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.1 X 22 WCAT-AAA1413 |
| 83 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.. BEE 5 Star rated-1200mm sweep 1501 |
| 84 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve5 - 32 amps.Cat. A 1002 |
| 85 | Supply and fixing of 6Amp to 32 Amp DP MCB(10KA)C Curve 32 Amp. DP MCB(10KA) C Curve-Cat. A 1009 |
| 86 | Supply and fixing of flush/surface mounting distribution boardswith additional metal door without MCBcomplete in all respects. 8 Way SPN Cat. A 1024(A) |
| 87 | Supply and fixing of single pole MCB blanking plate CAT B 1034(B |
| 88 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work.1139(A) |
| 89 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. 1116 |
| 90 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. 1149 |
| 91 | Supplyfixingofelectronic fan regulator (Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 1203(C) |
| 92 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sqmm 3.5 core 501(k) |
| 93 | Scraping old white wash or colour wash I/C disposal of refuse as directed by Engineer-in-charge.Si no-708. |
| 94 | Providing wall Cement Based Putty on New surface with approval quality material of berger/J.K./Birla or Similar make 2 coats. |
| 95 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 96 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 97 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 98 | Adjustment for Say |