Supply, Installation & Commissioning Of Modern Scientific And Electronic Instruments For Monitoring, Operation And Collecting Hydrometric Data Of Reservoir, Both Indravati And Muran Composite Dam, Podagada Earth Dam & Kapur Earth Dam Including Security Su, khatiguda-Odisha

Dam Division has published Supply, Installation & Commissioning Of Modern Scientific And Electronic Instruments For Monitoring, Operation And Collecting Hydrometric Data Of Reservoir, Both Indravati And Muran Composite Dam, Podagada Earth Dam & Kapur Earth Dam Including Security Su. Submission Date for this Tender is 11-12-2023. Civil Work Tenders in khatiguda Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

40750663
Supply, Installation & Commissioning Of Modern Scientific And Electronic Instruments For Monitoring, Operation And Collecting Hydrometric Data Of Reservoir, Both Indravati And Muran Composite Dam, Podagada Earth Dam & Kapur Earth Dam Including Security Su
Open Tender
Indian
Odisha
khatiguda
11-12-2023

Tender Details

Supply, Installation & Commissioning Of Modern Scientific And Electronic Instruments For Monitoring, Operation And Collecting Hydrometric Data Of Reservoir, Both Indravati And Muran Composite Dam, Podagada Earth Dam & Kapur Earth Dam Including Security Surveillance System, Uidc, Khatiguda.- 1 DATA REPORTING & VISUALIZATION • Data Visualization Dashboard • Customization of Reports & Parameters• Data analytics in Graphical format and reports in tabular format (xlsx, csv, PDF)• Mobile based Notifications / AlertsAutomated historical Data back-up & recovery system in case of loss of data.1.01) Non-contact type Radar water level sensor (35 M ) 2 Data Acquisition System:• Communication Option : 4G, WIFI• Supporting Protocols: MQTT,TCP/IP,HTTP,UDP• Firmware and configuration Update : Over the Air.• Internal Flash Memory : 32MB• Processor: 32 Bit ARM Cortex Processor• Protection :With Encloser: IP 68 3 Installation, Testing & Commissioning 4 Application Software:•Real Time Data reporting to Concerned Authority through Web app, Android/iOS app and customisation of report as per end users requirement. •Integration of DAS with Code analyzer Server Installed at Dam safety Office, Bhubaneswar.•Reporting to Field staffs and flood cell division through SMS facility. 5 V-Notch:- Supply and installation Fiberglass Reinforced Plastic (FRP) an improved “Venturi” plateconformed to IS: 9108 for accurate measurement of water flowing through channels comprisingof masonry construction provided with pre-fabricated glass fiber lining on both sides, a side chamber provided in one side masonry wall of the said flume on the upstream side, a pipe provided at the bottom of the chamber connecting the said chamber with the water flowing through the notch, a float means provided in the said chamber, enabling recording the rising or falling level of water in the said chamber such as a scale provided in the said chamber, moulded engraved gauge marking in lit/sec and also in centimeter including moulded and engraved discharge table, capacity marking, flow direction, manufacturer name and M.S pipe stiffeners, hold fasts, sand treatment on the backside of plate, compatible for installation of Digital Recorder for auto discharge measurement with M-100 concrete for 0.15 M bed concrete below V-Notch, 0.15 M side wall concrete of both sides of V-Notch length and 0.15 M transition in upstream and downstream side of V-Notch with smooth plastering only at top side of concrete wall etc. complete as directed as per drawing enclose. For any extra civil work other than mentioned above if require as per site condition for installation of V-Notch shall be executed by department with their agency at their cost.2.01) Seepage drain - 15 Lit./sec. V-Notch 6 Seepage drain - 60 Lit./sec. V-Notch 7 Calibration Marks:- Providing & fixing of polymers compositesimproved calibration markswith contact molding process, both side finish, M.S. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with marking in reduced levels, sill, FSL, FRL, MWL as per the demand of Engineer-in-charge etc. complete3.01) At Dam Wall of Muran & Indravati:- MWL- DSL (642- 625) = 17.5m approximately =17.5 x 0.3 w x 2set= 10.50 Sqm 8 Presentation Charts: - Providing & fixing of polymers composites improved calibration marks with contact molding process, both side finish, M.S. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with engraved marking of salient features, chainages, numbers and instructions in eye pleasant colour combinations as per the demand of Engineer-in-charge etc. Complete for given size and location including M.S. frame and concrete work etc. complete as directed by Engineer-in-charge.4.01) Salient feature board :- 1.5m x 2.0m x 4 nos.=12 sqm 9 Chainage boards:-0.30 x 0.30 x 57nos. (Dams -45 nos+Gates-12 nos = 57nos ) =5.13 sqm 10 Instruction Board:- 1.0 x0.60 x4nos.= 2.4 sqm 11 Direction Board:- 1.5 x 1.0 x 4Nos =6 sqm 12 TOTAL WEATHER STATION TAG TO SERVER:-Providing, fixing, testing,training, and commissioning of Total Weather Station Tag to Server with SMS facility which Installed at Dam Safety Office Bhubaneswar with 4G communication Interface. Metrological Station, IMD Approved monitoring of hourly data of temperature, humidity, wind velocity and rain gauge of data transfer through sms for 4 mobile numbers, android & iOS mobile application and tag to Code Analyser Server with software,solar power system will be deployed for 15 days backup, mounting, etc. complete as directed by Engineer-in-charge. Parameters: In SMS• Location, date, time• Rainfall in user-defined time interval and cumulative rain fall.• Temperature: Minimum and Maximum in a day.• Relative Humidity: Minimum and Maximum in a day.• Wind Speed: Minimum and Maximum in a day.5.01) TOTAL WEATHER STATION TAG TO SERVER 13 Providing and fixing, fencing to recorder cabin for Extra protection for TWS including 50/50/6 MS angle structure covered with MS mesh of size 2.5/2.5cm with anticorrosive epoxy coats etc complete as directed by Engineer-in-charge. 14 Ordinary/Standard Rain gauge made of fiber as per ISS225:1970 15 Casagrande Porous Tube Piezometer 27mm OD, 17mm ID, 1m/3m long, with all accessories considering maximum depth up to 18mtr, including drilling, back filling, minor civil work and fencing (construction ofsmall platform 0.5X0.5 m & 0.8/0.9 m height steel/GI mesh barricade and with one gated entry point) etc. as per the advice of Engineer-in-Charge.(A) Casagrande Pours Tube Piezometer made of carborundum or alundum, 38mm outer dia, 25mm inner dia, 600mm long with 3nos tie rod and brass adapter as per IS Standard -7356 (Part-1) (B) Semi rigged plastic standpipe, 27mm OD 17 MM ID Length- 3mt (C) Top plug with nipple. (D) Coupler for joining. (E) Protective pipe 100mm dia. × 1m long with lockable cap. 16 Readout Unit For PiezometerElectronic Water Level Indicator, forDepth up to 50mtr with sensor dia 10mm, 9-volt dry battery, audio visual indicator and accuracy up to 02mm. 17 Providing & fixing Block Joint Meter with below detailed specificationincluding cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge.a) Range: 0 - 50 mm, b) Accuracy : +/- 0.5 % FS, c) Resolution: 0.05 mm, d) emp limit: 10 to 70 deg C, e) Thermister: YSI-44005 or equivalent, Material: Stainless steelf) Materials: Stainless steel, g)Type: VW Triaxial type 18 4 core jelly filled cable 19 40 core jelly filled cable 20 Data Acquisition System. DAS consistsMaximum Sensor Capacity: 150 to 180 sensors / channels with thermistors and above Analog Channels 16 analog input channels (expandable to 320*) Each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or Three common referenced 2-wire inputs. The following maximums apply. Two wire with common reference terminal: 48 (expandable to 960*) Two wire isolated: 32 (expandable to 640*) Three and four wire isolated: 16 (expandable to 320*) Accuracy Measurement at ... 5°C to 40°C – 45°C to 70°C DC Voltage 0.1% 0.35% DC Current 0.15% 0.45% DC Resistance 0.1% 0.35% Frequency 0.1% 0.25% Sampling Integrates over 50/60Hz line period for accuracy and noise rejection. Maximum sample speed: 25Hz Effective resolution: 18 bits Linearity: 0.01% Common mode rejection: >90dB Line series mode rejection: >35dB Limited to, those listed below. A wide range of sensor scaling and line arising facilities including polynomials, expressions and functions. Vibrating Wire Frequency range: 500 to 5kHz Coil resistance: 50 to 200O Stimulation method: single pulse pluck Thermistors Types: YSI 400xx Series, other types* Resistance range: <10kO** Relay Output 1 latching relay, contacts (max: 30Vdc, 1A) Alarms Condition: high, low, within range and outside range Delay: optional time period for alarm response Actions: set digital outputs, transmit message.Data Storage Internal Store Capacity: 128MB = approx 10,000,000 data points Removable USB store device (optional accessory) Types: compatible with USB 1.1 or USB 2.0 drives, e.g. Flash drive. Capacity: approx. 90,000 data points per megabyte. Communication Interfaces Ethernet Port Interface: 10BaseT (10Mbps) Protocol: TCP/IP, Modbus (Master and Slave) USB Port Interface: USB 1.1 (virtual COM port) Protocol: ASCII command Display and Keypad Type: LCD, 2 line by 16 characters, backlight. Display Functions: channel data, alarms, system status. Keypad: 6 keys for scrolling and function execution. Status LEDs: 4 for sample, disk, attention and power. 21 Cable-splicing Kit 22 Junction Box 1:10 23 Providing & fixing PH Meter ( Portable) 3 1/2 digit LCD display in ABS plastic body with touch switches and combination PH electrode of following salient features with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. a) Measurers PH, MV and Temperature 5 point Calibration. b) 16 x 2 line Alphanumeric LCD with backlit.c) Auto Buffer Recognition Facility. d) Storage Up to 1000 samples. e) Attachment for Centronics Dot Matrix Printer. 24 Supply, installation & monitoring of STRONG MOTION ACCELEROMETER (SMA) Specification – SMA including Small Hut for protection from weather -- Real Time monitoringAccelerograph Including Instrument room with seismic pier for mounting of SMA and Accessories: Truly Triaxial Orthogonal, Broadband, Digital Accelerometer with flexible gain option; Response: DC to 315 Hz; Variable Gain Option: ±4 g, ±2 g, ±1 g or ±0.5 g; On board coloured Touch-sensitiveLCD screen for real time viewing & configuration;Dual redundant 64 GB micro SD cards.Humidity & Temperature also can be monitor from SMA Master GPS: GNSS PTP Grandmaster clock with external GPS antenna for control room Real-time Monitoring Network : 6 core armoured Optical Fiber Cable 1200 meter & Laying converter OR Outdoor Wi-Fi Network can be used instead of Optical Fiber Network. Purpose: For Local Vibration monitoring. Suitable for structural health monitoring for Dam for generation of PGA, PGV & PGD and time series recording for long time monitoring. 25 Supplying & fixing Digital Display Portable ISI marked Stop Watch with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. 26 Tilt Meter – Vibrating Wire type (Uniaxial) (Provision for connect to DAS) Sensor type: Vibrating Wire or MEMS Type Range : ±10°Accuracy : ± 0.1% FSCoil Resistance: 140 - 160 ohmInsulation: > 500 ohm at 12V DC Resistance Temperature : – 10° to +70° C. Over range : 150%Effect Humidity : 0 to 100% RHMaterial : Stainless steelMeets IP - 68, weather protection clauseCable : 2 - Core shielded, 1 m 27 Automatic X-Y Plumb-line Coordinator(Direct Plumbline): Automatic measurement of X and Y axes are taken along the wire, using a portable optical readout or. an automatic CCD (Charged Coupled Device) system. For both Inverted and Hanging Pendulum, vertical (Z axis) measurements can optionally be taken by using a CCD system in conjunction with a reference mark on the wire. The Inverted Pendulum uses identical measuring device, but the wire is anchored in stable ground beneath the structure, and the float fixed to the upper end of the wire which floats in a water tank, tensioning the wire and keeping it vertical. Displacement relative to the wire is measured using a portable optical readout OR, for a remote reading, an automatic CCD system is used. The reading arrays are corrected for temperature, and an external digital display can be connected to the readout unit to display the X and Y position in millimeters. Range: X =± 25 mm & Y=±25 mm. Resolution: 0.01 mm. Repeatability: ± 0.1 mm. Accuracy: ±0.1 mm. Operating humidity: 100 % RH non condensing. Temperature: - 15 to + 60deg C. Communication: RS485 Analog Output: 4-20 mA Power supply: AC 85V-230 V, 50 Hz Dimensions: 380 mmX330 mmX145 mm. Portable Pendulum Readout: Range: X=±75mm,Y=±75mm Resolution: 0.1 mm. Repeatability: ±0.1 mm. Accuracy: ± 0.1 mm.Accessories:* Anchoring Plate with Collet for Suspension wire.* Suspension Weight : 10 Kg* Suspension Wire -Stainless Steel 50 m* Bucket for Oil (PVC 40 litter’s capacity).* Damping Oil (S.A.E Oil 40 or equivalent).Purpose: Dam Tilt measuring system (With reference to the dam top monitoring the deflection of the Dam structure) 28 Supplying & fixingHigh Resonance CC TV Camera system, Gorilla Type, with 8 Ch 4 K net work video recorder, 8 channel IP camera input, H.265/H.264 dual video formats,support 4 K resolution up to 8 MP recording, 80 Mbps incoming/ outgoing bandwidth, support 1SATA HDDs up to 8TB, 3USB ports, support multi-brand network cameras, mobile software: Android, iOS,CMS Software : IVMS etc; with following accessories with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. 20.01) CPPLUS/HIKVISION16 CH NVR 2 SATA 29 CPPLUS/HIKVISION2 MP IP PTZ (Moving camera) 30 CPPLUS/HIKVISION 3 MP IP MOTORISED VERRY FOCAL (Fixed Camera) 31 8 PORT POE SWITCH SFP PORT (Fiber Port) 140wt. 32 4 PORT POE SWITCH SFP PORT ( Fiber Port) 33 SURVILANCE HDD 4 TB SV 34 CAT 6 CABLE 35 RJ 45 CLIPS 36 FIBER ARMOURED CABLE 37 NORMAL 8 PORT DESKTOP SWITCH 38 For CC TV Display (55” 4k) with all accessories 39 Power backup unit for CC TV with all accessories. 40 DIGISOL RACKMOUNT LIU 6 PORT 41 DIGISOL SC TO LC CABLE 42 4U RACK 43 9U RACK 500 DEPTH 44 1000 SINGLE MODE FIBER MODULE 45 FIBER SPICEING 46 ADD CESS 47 INSTALLATION CHARGE

Key Value

Document Fees
INR 10000 /-
EMD
INR 185000.0 /-
Tender Value
INR 1.84 Crore /-

BOQ Items

Name of Work: "Supply,Installation & Commissioning of Modern Scientific and Electronic Instruments for Monitoring, Operation and collecting Hydrometric data of Reservoir, Both Indravati and Muran Composite Dam, Podagada Earth Dam & Kapur Earth Dam including Security Surveillance System, UIDC, Khatiguda."
Sl. No. Item Description
1DATA REPORTING & VISUALIZATION • Data Visualization Dashboard • Customization of Reports & Parameters • Data analytics in Graphical format and reports in tabular format (xlsx, csv, PDF) • Mobile based Notifications / Alerts Automated historical Data back-up & recovery system in case of loss of data.1.01) Non-contact type Radar water level sensor (35 M )
2Data Acquisition System: • Communication Option : 4G, WIFI • Supporting Protocols: MQTT,TCP/IP,HTTP,UDP • Firmware and configuration Update : Over the Air. • Internal Flash Memory : 32MB • Processor: 32 Bit ARM Cortex Processor • Protection :With Encloser: IP 68
3Installation, Testing & Commissioning
4Application Software: •Real Time Data reporting to Concerned Authority through Web app, Android/iOS app and customisation of report as per end users requirement. •Integration of DAS with Code analyzer Server Installed at Dam safety Office, Bhubaneswar. •Reporting to Field staffs and flood cell division through SMS facility.
5V-Notch:- Supply and installation Fiberglass Reinforced Plastic (FRP) an improved “Venturi” plateconformed to IS: 9108 for accurate measurement of water flowing through channels comprisingof masonry construction provided with pre-fabricated glass fiber lining on both sides, a side chamber provided in one side masonry wall of the said flume on the upstream side, a pipe provided at the bottom of the chamber connecting the said chamber with the water flowing through the notch, a float means provided in the said chamber, enabling recording the rising or falling level of water in the said chamber such as a scale provided in the said chamber, moulded engraved gauge marking in lit/sec and also in centimeter including moulded and engraved discharge table, capacity marking, flow direction, manufacturer name and M.S pipe stiffeners, hold fasts, sand treatment on the backside of plate, compatible for installation of Digital Recorder for auto discharge measurement with M-100 concrete for 0.15 M bed concrete below V-Notch, 0.15 M side wall concrete of both sides of V-Notch length and 0.15 M transition in upstream and downstream side of V-Notch with smooth plastering only at top side of concrete wall etc. complete as directed as per drawing enclose. For any extra civil work other than mentioned above if require as per site condition for installation of V-Notch shall be executed by department with their agency at their cost.2.01) Seepage drain - 15 Lit./sec. V-Notch
6Seepage drain - 60 Lit./sec. V-Notch
7Calibration Marks:- Providing & fixing of polymers compositesimproved calibration markswith contact molding process, both side finish, M.S. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with marking in reduced levels, sill, FSL, FRL, MWL as per the demand of Engineer-in-charge etc. complete3.01) At Dam Wall of Muran & Indravati:- MWL- DSL (642- 625) = 17.5m approximately =17.5 x 0.3 w x 2set= 10.50 Sqm
8Presentation Charts: - Providing & fixing of polymers composites improved calibration marks with contact molding process, both side finish, M.S. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with engraved marking of salient features, chainages, numbers and instructions in eye pleasant colour combinations as per the demand of Engineer-in-charge etc. Complete for given size and location including M.S. frame and concrete work etc. complete as directed by Engineer-in-charge.4.01) Salient feature board :- 1.5m x 2.0m x 4 nos.=12 sqm
9Chainage boards:-0.30 x 0.30 x 57nos. (Dams -45 nos+Gates-12 nos = 57nos ) =5.13 sqm
10Instruction Board:- 1.0 x0.60 x4nos.= 2.4 sqm
11Direction Board:- 1.5 x 1.0 x 4Nos =6 sqm
12TOTAL WEATHER STATION TAG TO SERVER:-Providing, fixing, testing,training, and commissioning of Total Weather Station Tag to Server with SMS facility which Installed at Dam Safety Office Bhubaneswar with 4G communication Interface. Metrological Station, IMD Approved monitoring of hourly data of temperature, humidity, wind velocity and rain gauge of data transfer through sms for 4 mobile numbers, android & iOS mobile application and tag to Code Analyser Server with software,solar power system will be deployed for 15 days backup, mounting, etc. complete as directed by Engineer-in-charge. Parameters: In SMS • Location, date, time • Rainfall in user-defined time interval and cumulative rain fall. • Temperature: Minimum and Maximum in a day. • Relative Humidity: Minimum and Maximum in a day. • Wind Speed: Minimum and Maximum in a day.5.01) TOTAL WEATHER STATION TAG TO SERVER
13Providing and fixing, fencing to recorder cabin for Extra protection for TWS including 50/50/6 MS angle structure covered with MS mesh of size 2.5/2.5cm with anticorrosive epoxy coats etc complete as directed by Engineer-in-charge.
14Ordinary/Standard Rain gauge made of fiber as per ISS225:1970
15Casagrande Porous Tube Piezometer 27mm OD, 17mm ID, 1m/3m long, with all accessories considering maximum depth up to 18mtr, including drilling, back filling, minor civil work and fencing (construction ofsmall platform 0.5X0.5 m & 0.8/0.9 m height steel/GI mesh barricade and with one gated entry point) etc. as per the advice of Engineer-in-Charge.(A) Casagrande Pours Tube Piezometer made of carborundum or alundum, 38mm outer dia, 25mm inner dia, 600mm long with 3nos tie rod and brass adapter as per IS Standard -7356 (Part-1) (B) Semi rigged plastic standpipe, 27mm OD 17 MM ID Length- 3mt (C) Top plug with nipple. (D) Coupler for joining. (E) Protective pipe 100mm dia. × 1m long with lockable cap.
16Readout Unit For PiezometerElectronic Water Level Indicator, forDepth up to 50mtr with sensor dia 10mm, 9-volt dry battery, audio visual indicator and accuracy up to 02mm.
17Providing & fixing Block Joint Meter with below detailed specificationincluding cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge.a) Range: 0 - 50 mm, b) Accuracy : +/- 0.5 % FS, c) Resolution: 0.05 mm, d) emp limit: 10 to 70 deg C, e) Thermister: YSI-44005 or equivalent, Material: Stainless steelf) Materials: Stainless steel, g)Type: VW Triaxial type
184 core jelly filled cable
1940 core jelly filled cable
20Data Acquisition System. DAS consistsMaximum Sensor Capacity: 150 to 180 sensors / channels with thermistors and above Analog Channels 16 analog input channels (expandable to 320*) Each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or Three common referenced 2-wire inputs. The following maximums apply. Two wire with common reference terminal: 48 (expandable to 960*) Two wire isolated: 32 (expandable to 640*) Three and four wire isolated: 16 (expandable to 320*) Accuracy Measurement at ... 5°C to 40°C – 45°C to 70°C DC Voltage 0.1% 0.35% DC Current 0.15% 0.45% DC Resistance 0.1% 0.35% Frequency 0.1% 0.25% Sampling Integrates over 50/60Hz line period for accuracy and noise rejection. Maximum sample speed: 25Hz Effective resolution: 18 bits Linearity: 0.01% Common mode rejection: >90dB Line series mode rejection: >35dB Limited to, those listed below. A wide range of sensor scaling and line arising facilities including polynomials, expressions and functions. Vibrating Wire Frequency range: 500 to 5kHz Coil resistance: 50 to 200O Stimulation method: single pulse pluck Thermistors Types: YSI 400xx Series, other types* Resistance range: <10kO** Relay Output 1 latching relay, contacts (max: 30Vdc, 1A) Alarms Condition: high, low, within range and outside range Delay: optional time period for alarm response Actions: set digital outputs, transmit message.Data Storage Internal Store Capacity: 128MB = approx 10,000,000 data points Removable USB store device (optional accessory) Types: compatible with USB 1.1 or USB 2.0 drives, e.g. Flash drive. Capacity: approx. 90,000 data points per megabyte. Communication Interfaces Ethernet Port Interface: 10BaseT (10Mbps) Protocol: TCP/IP, Modbus (Master and Slave) USB Port Interface: USB 1.1 (virtual COM port) Protocol: ASCII command Display and Keypad Type: LCD, 2 line by 16 characters, backlight. Display Functions: channel data, alarms, system status. Keypad: 6 keys for scrolling and function execution. Status LEDs: 4 for sample, disk, attention and power.
21Cable-splicing Kit
22Junction Box 1:10
23Providing & fixing PH Meter ( Portable) 3 1/2 digit LCD display in ABS plastic body with touch switches and combination PH electrode of following salient features with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. a) Measurers PH, MV and Temperature 5 point Calibration. b) 16 x 2 line Alphanumeric LCD with backlit.c) Auto Buffer Recognition Facility. d) Storage Up to 1000 samples. e) Attachment for Centronics Dot Matrix Printer.
24Supply, installation & monitoring of STRONG MOTION ACCELEROMETER (SMA) Specification – SMA including Small Hut for protection from weather -- Real Time monitoring Accelerograph Including Instrument room with seismic pier for mounting of SMA and Accessories: Truly Triaxial Orthogonal, Broadband, Digital Accelerometer with flexible gain option; Response: DC to 315 Hz; Variable Gain Option: ±4 g, ±2 g, ±1 g or ±0.5 g; On board coloured Touch-sensitiveLCD screen for real time viewing & configuration;Dual redundant 64 GB micro SD cards.Humidity & Temperature also can be monitor from SMA Master GPS: GNSS PTP Grandmaster clock with external GPS antenna for control room Real-time Monitoring Network : 6 core armoured Optical Fiber Cable 1200 meter & Laying converter OR Outdoor Wi-Fi Network can be used instead of Optical Fiber Network. Purpose: For Local Vibration monitoring. Suitable for structural health monitoring for Dam for generation of PGA, PGV & PGD and time series recording for long time monitoring.
25Supplying & fixing Digital Display Portable ISI marked Stop Watch with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge.
26Tilt Meter – Vibrating Wire type (Uniaxial) (Provision for connect to DAS) Sensor type: Vibrating Wire or MEMS Type Range : ±10°Accuracy : ± 0.1% FSCoil Resistance: 140 - 160 ohmInsulation: > 500 ohm at 12V DC Resistance Temperature : – 10° to +70° C. Over range : 150%Effect Humidity : 0 to 100% RHMaterial : Stainless steelMeets IP - 68, weather protection clauseCable : 2 - Core shielded, 1 m
27Automatic X-Y Plumb-line Coordinator(Direct Plumbline): Automatic measurement of X and Y axes are taken along the wire, using a portable optical readout or. an automatic CCD (Charged Coupled Device) system. For both Inverted and Hanging Pendulum, vertical (Z axis) measurements can optionally be taken by using a CCD system in conjunction with a reference mark on the wire. The Inverted Pendulum uses identical measuring device, but the wire is anchored in stable ground beneath the structure, and the float fixed to the upper end of the wire which floats in a water tank, tensioning the wire and keeping it vertical. Displacement relative to the wire is measured using a portable optical readout OR, for a remote reading, an automatic CCD system is used. The reading arrays are corrected for temperature, and an external digital display can be connected to the readout unit to display the X and Y position in millimeters. Range: X =± 25 mm & Y=±25 mm. Resolution: 0.01 mm. Repeatability: ± 0.1 mm. Accuracy: ±0.1 mm. Operating humidity: 100 % RH non condensing. Temperature: - 15 to + 60deg C. Communication: RS485 Analog Output: 4-20 mA Power supply: AC 85V-230 V, 50 Hz Dimensions: 380 mmX330 mmX145 mm. Portable Pendulum Readout: Range: X=±75mm,Y=±75mm Resolution: 0.1 mm. Repeatability: ±0.1 mm. Accuracy: ± 0.1 mm. Accessories: * Anchoring Plate with Collet for Suspension wire. * Suspension Weight : 10 Kg * Suspension Wire -Stainless Steel 50 m * Bucket for Oil (PVC 40 litter’s capacity). * Damping Oil (S.A.E Oil 40 or equivalent). Purpose: Dam Tilt measuring system (With reference to the dam top monitoring the deflection of the Dam structure)
28Supplying & fixingHigh Resonance CC TV Camera system, Gorilla Type, with 8 Ch 4 K net work video recorder, 8 channel IP camera input, H.265/H.264 dual video formats,support 4 K resolution up to 8 MP recording, 80 Mbps incoming/ outgoing bandwidth, support 1SATA HDDs up to 8TB, 3USB ports, support multi-brand network cameras, mobile software: Android, iOS,CMS Software : IVMS etc; with following accessories with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. 20.01) CPPLUS/HIKVISION16 CH NVR 2 SATA
29CPPLUS/HIKVISION2 MP IP PTZ (Moving camera)
30CPPLUS/HIKVISION 3 MP IP MOTORISED VERRY FOCAL (Fixed Camera)
318 PORT POE SWITCH SFP PORT (Fiber Port) 140wt.
324 PORT POE SWITCH SFP PORT ( Fiber Port)
33SURVILANCE HDD 4 TB SV
34CAT 6 CABLE
35RJ 45 CLIPS
36FIBER ARMOURED CABLE
37NORMAL 8 PORT DESKTOP SWITCH
38For CC TV Display (55” 4k) with all accessories
39Power backup unit for CC TV with all accessories.
40DIGISOL RACKMOUNT LIU 6 PORT
41DIGISOL SC TO LC CABLE
424U RACK
439U RACK 500 DEPTH
441000 SINGLE MODE FIBER MODULE
45FIBER SPICEING
46ADD CESS
47INSTALLATION CHARGE
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail