Tender For Supplying, Fixing, Testing And Commissioning Of Split Ac At Mass Spectrometry Facility Lab (Ciri) At Main Campus., Srinagar-Jammu And Kashmir

University Of Kashmir (Jammu) has published Tender For Supplying, Fixing, Testing And Commissioning Of Split Ac At Mass Spectrometry Facility Lab (Ciri) At Main Campus.. Submission Date for this Tender is 30-11-2023. Air Conditioner Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

40737827
Corrigendum : Tender For Supplying, Fixing, Testing And Commissioning Of Split Ac At Mass Spectrometry Facility Lab (Ciri) At Main Campus.
Open Tender
Indian
Jammu And Kashmir
Srinagar
30-11-2023

Tender Details

Supplying, Fixing, Testing And Commissioning Of Split Ac At Mass Spectrometry Facility Lab ( Ciri ) At Main Campus. , Supply, Fixing, Testing And Commissioningof Wall Mount Split Ac With Cooling Capacity 5000 W & Heating Capcity 6000W, Power Consumption Cooling / Heating 1.45Kw / 1.69Kw ( 4Star Ratting ) Split Fully Inverter Type With Heat Pump, Fan Coil Unitand Condensing Unit Hot And Cold Operation Temperature Range Should Be Minimum -15 ( Minus ) To 46 Degree C Inverter Technology . Including Control Wiring, Ac Remote With Cells, Refrigerant Gas Filling If Requriredcomlete In All Respects. With Two Years Warrenty Period. , Supply, Fixing, Testing And Commissioningofof Copper Piping ( Soft ) With 9Mm Nitrite Rubber Insulation On Both Pipes With Steel Clamps And Including Fully Gi Tapping , Supply And Fixing Offixing Of Pvc Flexible Pipe For Drain Pipe , Supply And Fixing Ofcontrol And Power Cable For Connection Of Indoor And Outdoor Units As Per Specifications Of Oem , Supply And Fixing Ofof M.S Stands For Outdoor Unitsas Per Specifications Of Oem , Supply And Fixing Ofof 5Kva Automatic Voltage Regulator ( Avr ) Air Cooled Copper Wounded Wall Mounted Having Input Line Voltage From 90 Volts To 260 Volts With Time Hi, Low Cut And Delay Protections. Including Required Length Of Recommended Leads , Providing And Fixing Of Ac Points Using 6 Sq Mm Pvc Frlsinsulated Copper Wire Ofincluding Through 1 Inch Heavy Duty Pvc Conduit Pipe And Providing And Fixing Of 32 Amp Dp Mcb 10Ka C Curve With Enclosure Including Providing And Fixing Of 6 Sq. Mm Pvc Insulated Copper Wire As Earth Wire, Point Taken Up To D.B. Duly Tested And Commissioned In All Respects Complete. , Note. The Quoted Percentage ( %Age ) Should Preferably Be In Fractional Form In Order To Minimize Concurrence Of Similar Quoted Rates

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Nov-2023 Date Extension Date 30-11-2023

Key Value

Document Fees
INR 200 /-
EMD
INR 4080.0 /-
Tender Value
INR 2.04 Lakhs /-

BOQ Items

Name of Work: Supplying, Fixing, Testing and Commissioning of split AC at Mass Spectrometry facility Lab (CIRI) at Main Campus (Advertised cost Rs. 2.04Lacs)
Sl. No. Item Description
1Supply, fixing,testing and commissioningof wall mount Split AC with Cooling capacity 5000 W & Heating Capcity 6000W, power consumption cooling/heating 1.45KW/1.69KW (4star Ratting)split fully inverter type with Heat Pump, fan coil unitand condensing unit Hot and Cold operation temperature range should be minimum -15(minus) to 46 degree C Inverter technology . including control wiring, AC remote with cells, Refrigerant Gas filling if requriredcomlete in all respects. with two years warrenty period.
2Supply, fixing,testing and commissioningofof copper piping (soft) with 9mm nitrite rubber insulation on both pipes with steel clamps and including fully GI Tapping
3Supply and fixing offixing of PVC flexible pipe for drain pipe
4Supply and fixing ofcontrol and power cable for connection of indoor and outdoor units as per specifications of OEM
5Supply and fixing ofof M.S Stands for outdoor unitsas per specifications of OEM
6Supply and fixing ofof 5KVA Automatic Voltage Regulator (AVR) Air cooled Copper wounded wall mounted having input line voltage from 90 volts to 260 volts with time hi, low cut and delay protections. Including required length of recommended leads
7Providing and fixing of Ac points using 6 sq mm PVC FRLSinsulated copper wire ofincluding through 1 inch heavy duty PVC conduit pipe and providing and fixing of 32 Amp Dp MCB 10KA C curve with enclosure including providing and fixing of 6 sq. mm PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned in all respects complete.
8Note. The quoted percentage (%age) should preferably be in fractional form in order to minimize concurrence of similar quoted rates