| 1 | SafeLoading, Carriage and then safeunloading of the following material from Store Centres Under the jurisdiction of EE ESD Ayodhaya to dump site proper stacking. |
| 2 | PCC pole 9 Mtr. |
| 3 | STP 11 Mtr. |
| 4 | M.S. Top Channel 125x65mm 3200 mm |
| 5 | M.S. Angle 65x65x6 mm Bracing, 4300 mm |
| 6 | MS Angle for guarding 65x65x6 mm, 3500 mm long |
| 7 | GI Wire 8 SWG |
| 8 | GI Wire 6 SWG |
| 9 | 33 KV Disc Insulator B & S Type polymer |
| 10 | 33 KV V Type channel cross arm |
| 11 | 33 KV Pin Insulator polymer type |
| 12 | Stay Wire 7/8 SWG |
| 13 | ACSR Dog Conductor |
| 14 | 33 KV 3x120 sq mm XPLE Cable |
| 15 | 33 KV Outdoor jointing Kit for 3x120 sq mm XLPE Cable |
| 16 | 33 KV S/T Jointing kit |
| 17 | Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Channel Cross Arm,3 NO. Pin insulator as per norms. (Contractor shall providenecessary clamps, F-brackets, Nut - Bolts, Washers etc.) |
| 18 | Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm,3 NO. Pin insulatoras per norms. (Contractor shall provide, necessary clamps, F-brackets, Nut - Bolts, Washers etc.) |
| 19 | Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection forSectional Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm,6 No. Disc. Fitting , Bracing angle 1 set., Disc insulator 6 No. and 3 No. Pin insulator as per norms. (Contractor shall provideE- Bracket , necessary clamps, Disc Fitting, Nut - Bolts etc.) |
| 20 | Erection of single stud pole support on PCC Pole 9.0 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washersetc) |
| 21 | Cradle Guarding of 33 KV line at road crossing, 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting. (Contractor shall provide Necessary clamps for fitting of guarding angle and 6 No. Eye Bolt 12x110 mm etc.) |
| 22 | Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material and stay set, stay clamp will be arranged by the contractor except stay wire) |
| 23 | Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point. (Contractor shall provide necessary PG clamps etc) |
| 24 | Laying & Dressing of 3x300 sq. mm XLPE Cable underground single Circuit.Laying of singlecircuit 3x300 sq .mm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and stone slab. The inter axial spacing between two cables should be in between 0.25 to 0.04 M. After laying the cable refilling and ramming of the left out soil,closing the trench and leveling. |
| 25 | Installation of Heat Shrinkable Type cable jointing kits of following types/sizes for 33 XLPE Cable. |
| 26 | (a) Fixing of 33 KV 3x300 sq. mm Straight Throughjoints. (jointing kit supplied by dept.) |
| 27 | (b) Fixing of 33 KV 3x300 sq. mm Outdoor End Terminations(jointing kit supplied by dept.) |
| 28 | High Pressure testing to which 33 KV Line & cable to be stand for duration of 5 minutes after completion of Laying, Stringing, sagging, binding and Jumpering of ACSR Dog conductor. ( Testing equipment will be arranged by the contractor) |
| 29 | Hoisting of 33 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x300 sq mm cable fixing of proper support and its clamping, providing long barral lugs 6 nos and P.G. Clamps & \"Y\" shapejumpering properly and 02 nos. supporting angle 65X65X6, 2240 mm long and making connection including supply of jumpering cable ,mounting clamps as per RESSPO Norms. (All material will be supplied by the contractor like M.S Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65X6, 2240 mm and jumpering cable suitable for 33KV jumper). |
| 30 | Grouting of following structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering. |
| 31 | 11 Mtr ST Poles |
| 32 | 9.0 Mtr PCC pole |
| 33 | Supply and fixing of a stone pad of size 300x300x75 mm at PCC/STP Bottom of the pit ( Contractor shall provide all materials) |
| 34 | Fixing of barbed wire on poleSupply and fixing of barbed wire on the pole above 2750 mm ground level. Barbed wirewrapped for a distance of 0.9 mtr. with apitch of 13.mm at a height. (All materials supplied by the contractor) |
| 35 | Fixing of Danger board .Supply and fitting of Danger board of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55 |
| 36 | Fixing of Number plate .Supply and fitting of Number plate of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55 |
| 37 | Replacement of old and damage pin insulator with all fittings by new pin insulator at required places (except pin insulator) |
| 38 | Fixing of additional V-type X arm with clamp, nut & bolts etc. at required places. (Contractor shall provide clamp nut & bolts etc). |
| 39 | Fixing of additional Bracing angle 65x65x6 4300 mm with clamp, nut & bolts etc. at required places. (Contractor shall provide clamp nut & bolts etc). |
| 40 | Fixing of additional disc insulator B&S with clamp, nut & bolts etc. at required places. (Contractor shall provide clamp nut & bolts, 33 kV disc fitting etc.) |
| 41 | Angle for Cross arm Support at Angle Location 65x65x6 mm 1600 mm long with clamps and nut & bolt. (All materials will be supplied by the contractor) |
| 42 | Petrolling in feet from starting to end and removal/lopping and chopping of tree branches which are lying in routre of 33 KV overhead line. |
| 43 | Providing and fixing at the top of the pole Pcc & Stp Extension piece 1.5 mtr channel 125x65 mm and required places ( crossing of lines etc) and supporting with clamp and all fittings. (All materials will be supplied by the contractor). |
| 44 | Opening of binding of loose old ACSR DOG Conductor, Tightening, stringing, binding and Jumpering ofloose old ACSR Dogconductor in all respect. 3 Phase of 33KV Line including fixing,mounting of P.G.clamp suitable for Dog Conductor at sectional point.(All the material will be arrange by the contractor) |
| 45 | Straightening of additional existing erected/tilted pole with Digging & grouting at required places(All the civil material will be arranged by the contractor) Grouting ofstructure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering. |
| 46 | Providing of HDPE 6\"Dia Pipe PN-6 Specification |
| 47 | Laying of cable & HDPE PipeLaying of Single circuit 33 KV 3x300 Sq mm XLPE cable and HDPE Pipe by drilling method below NHAI road crossing. The cable be laid at the depth of 3 mtr from the under surface in HDPE pipe (200 mm. dia.) casing. |
| 48 | Permission of NHAI/PWD etc. for road crossing..( Final settlement of the payment will be done after providing receipt, agreement and permission paper) which is less coted by contractor of demand by NHAI/PWD. |
| 49 | Painting of poles Painting of poles with one coat of red oxide, two coats of enamel paint ISI mark. (All required material will be supplied by the contractor) |
| 50 | Faultlocator for old and existing 33 kv line and repairing of the calbe by installing S/T jointing kit if requerd upto energisging the 33 kv line. |