Housing Urban and Rular Development Government Departments Closing in 0 days TDR #40728221

Dtw Schemes Under Nabard Xxvii (Phase-Ii) Under South Tripura District During The Year 2022-23/ Sh:- Construction Of 02(Two) Nos. Semi-Permanent Pump House Of Size 4.00 Mtr X 3.00 Mtr, Installation Of Pump Motor In/C Panel Board, Electrical Equipments & L

Issued by Government Departments · South Tripura, Tripura
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Nov 2023
0 days left
EMD
49691
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
South Tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Dtw Schemes Under Nabard Xxvii ( Phase-Ii ) Under South Tripura District During The Year 2022-23 / Sh:- Construction Of 02 ( Two ) Nos. Semi-Permanent Pump House Of Size 4.00 Mtr X 3.00 Mtr, Installation Of Pump Motor In / C Panel Board, Electrical Equipments & Laying Of Upvc Distribution System Etc. For 2 ( Two ) Nos.Dtw Scheme I ) In The Land Of Nirmal Sarkar Under Durgapur G.P & Ii ) In The Land Of Ratan Aditya, Under South Srirampur G.P Rajnagar Rd Block

BOQ

Name of Work:DTW Schemes under NABARD XXVII (Phase-II) under South Tripura district during the year 2022-23/ SH:- Construction of 02(Two) nos. semi-permanent pump house of size 4.00 Mtr X 3.00 Mtr, Installation of pump motor in/c panel board, electrical equipments & laying of UPVC distribution system etc. for 2(Two) nos.DTW Scheme i) In the land of Nirmal Sarkar under Durgapur G.P & ii) In the land of Ratan Aditya, under South Srirampur G.P Rajnagar RD Block.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.- All kinds of soil
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
3Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
4Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level:
5i) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size)
6ii) 1:4:8 ( 1 Cement: 4 fine sand : 8 graded well burnt brick aggregate 40 mm nominal size)
7Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:
8a)1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brickaggregate of 20 mm nominal size)
9Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-
10i) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brickaggregate of 20 mm nominal size)
11First class brick work in foundation and plinth including cost of all materials as required complete:-
12i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).
13First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-
14In cement mortar 1:4 ( 1 cement : 4 fine sand )
15Extra for brick masonry work in triangular, square and rectangular pillars including cost of all materials as required complete.
16Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-
17i) In Cement mortar 1:4 ( 1 cement : 4 fine sand )
18Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.
19Thermo-Mechanically Treated bars of grade Fe 500D or more.
20Centering shuttering including struttings, propping etc. and removal of form work for:
21i) Foundations, footings, bases for columns etc. for mass concrete with timber plank
22ii) Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank
23Providing and fixing in position 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide sufficiently long at the top and bottom respectively, channels & with bolts, nuts, rivets, locking arrangement, stoppers, handles, hold fast including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.
24Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete
25i) 40 mm thick
26Providing and fixing corrugated G.S. Sheet roofing fixed with polymer coated J or L hooks 8 mm diameter, bolts and nuts 6 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with lead and including a coat of approved steel primer and two coats of approved epoxy paint on overlapping of sheets complete ( upto a pitch of 60 degrees ) over a built structure including all types of necessary scaffoldings etc.but excluding the cost of the purlins, rafters and trusses etc.as per clauses of Chapter - 12 of CPWD specification.
27i) 0.63 mm thick with zinc coating not less than 275 gm / m2
28Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
29i) With mild steel tubes Hot finished welded (HFW) type medium class.
3012 mm cement plaster of mix
31i.) Cement mortar 1:4 (1 cement : 4 fine sand)
3215 mm cement plaster on the rough side of single or half brick wall of mix:
33i. Cement mortar 1:4 (1 cement : 4 fine sand)
34Neat cement punning
35Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 3.84 kg/10 sqm) complete. [Payment shall be made after submission of Test Certificate issued by the Manufacturer.
36a)New work (two or more coats applied @ 3.84 kg/10 sqm)
37Distempering with oil bound washable distemper of approved brand and manufacture and of required shade on new work ( two or more coats ), over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]
38a)New work ( two or more coats) over and including water thinnable priming coat with cement primer.
39Providing and placing of G.I Pipe over the pump house on top portion of the RCC Column as per specification and the direction of the Engineer-in-charge. i) 150 mm dia
40Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
41i) 0.63mm thick with zinc coating not less than 275gm/m2
42Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square or round bars etc. all complete.
43Fixed to steel windows by welding.
44Providing and fitting fixing of 7500 GPH, 76 mtr head water lubricated submersible pump motor set of maximum 150 mm outer dia with maximum three (three) stage coupled with required wet and non-over loading submersible motor suitable for 340-440 volts 3-ph, 50 Hz AC supply and star delta method of starting along with 35 mtr 1x2x3x10 sqmm joint less PVC 3(three) core double length flat cable (continous length) of suitable size fitted with submersible motor, suction case, stainer, coulping key, verticle non return valve cum discharge case in/c supplying of 10 nos suitable guard with clips and nut and bolts, 2 pair MS column clamps in/c installation of submersible pump & motor up to the depth of 100 ft by G.I. pipe (Conforming to IS :1239 medium class) for column assembly which will be supplied by the agency at his own costs as per direction of the Engineer-In-Charge conforming to terms & conditions of the contract ( each pump motor shall consist of stainless closed type impeller, C.I. bowl, C.I. discharge cas,e pump shaft (stainless steel), bush (bronze) shaft sleve (Bronze/ Chromium) sand guard widening, motor, starter, counter thrust plate, thrust plate, thrust bearing segment etc. conforming to relevent BIS codes.
45Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inchx 9 feet ), nuts & bolts etc. for irrection of the same by1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and paintingtwo ormore coats & plastic paint as per specification and direction of the Engineer-in-charge.
46Providing and fitting fixing steel sheet enclosed switch fuse unit(suitable for DIN fuses), triple pole with Neutral Link (TPN), current range 63 Amps, 415/500 Volt, L & T / Havell\"s/HPL make etc. completeas per specification and direction of the Engineer-in-charge. i) 63 Amps
47Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of Thermal release range 25-32 Amps, 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge.i.25-32 Amps
48Supplying & fitting fixing manually operated oil immerged starter of approved quality.a) 30 Hp Osco/BCH Make
49Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
50Providing and fitting fixing of moving iron type, Range 0-100 V, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
51Providing andfitting, fixing of 3 phase indicating lamps fittedwith panel board with three different colour lamp complete with batten holder as per direction of the Engineer-in-Charge.
52Providing andfitting, fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge.i) 5-15 kVAr 440 V
53Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge. i. 95 sqmm
54Providing earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation ) , 2.50 mtr. Long , laying of 4 mm dia GI wire from earth electrode to panel,including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge. ii. for 3phase connection 4.00 mtr long G.I pipe
55Providing and fitting, fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range, 415+ V, 50 Hz (L & T, BCH, ABB make) as per direction of the Engineer-in-Charge. i. 50-63 Amps
56Excavating trenches of required width for pipes, cables, etc. including excavation for sockets and dressing of sides ramming of bottoms , depth minimum 1.25m including gettin out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil as directed within a lead of 50 m as per CPWD Specification & direction of Engineer-in-charge.A) All kinds of soil.
57a) Pipe , cables etc. exceeding 75mm dia but not exceeding 160 mm dia .
58Providing and laying different dia rigid UPVC pipes of Working Pressure 2.5 kg/4.0 kg/ sq.cm. complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineerin- charge.
59i) 160 mm dia
60ii) 140 mm dia
61iii) 110 mm dia
62iv) 90 mm dia
63Providing and fitting fixing of different dia rigid UPVC equal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in charge.
64i) 160x160x160 mm dia
65ii) 140x140x140 mm dia
66iii) 110x110x110 mm dia
67iv) 90x90x90 mm dia
68Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in charge.
69i) 160x160x140 mm dia
70ii) 160x160x110 mm dia
71iii) 160x160x90 mm dia
72iv) 140x140x110 mm dia
73v) 140x140x90 mm dia
74vi) 110x110x90 mm dia
75Providing and fitting fixing rigid UPVC Reducing socket (one size lower at one end, both end socketted) suitable for pipes of Working pressure 2.5/4.0 kg/sq.cm. as per CPWD Specification & direction of Engineer-in-charge.
76i) 160x140 mm dia
77ii) 140x110 mm dia
78iii) 110x90 mm dia
79Providing & fitting fixing rigid UPVC bend(30 degree,45 degree,60 degree, 90 degree) for UPVC pipes as per IS specification of Working pressure 2.5/4.0 kg/sq.cm as per CPWD Specification & direction of Engineer-in-charge.
80i) 160 mm dia
81ii) 140 mm dia
82iii) 110 mm dia
83iv) 90 mm dia
84Providing and fitting fixing of G.I hydrant suitable for PVC pipes as per standard specification complete as per direction of Engineer-incharge (Rate excluding the cost of NTP control valve).
85i) 80X50 mm dia
86Providing and fitting fixing of CI(Cast Iron) NTP control valve (40 mm) suitable for fitting fixing with GI hydrant point as per CPWD Specification & direction of Engineer-in-charge.
87Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
88Providing and fixing C.I. non-return valve of approved quality as per CPWD specification and direction of the Engineer - in - charge.
89i) 125 mm nominal bore
90Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
91i) 150 mm dia.A) P.N-1.6
92ii) 125 mm dia A) P.N-1.6
93iii) 100 mm dia. A) P.N-1.6
94iv) 80 mm dia. A) P.N-1.6
95Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
96i) 160 mm dia
97ii) 140 mm dia
98iii) 110 mm dia
99iv) 90 mm dia
100Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.A. External work.
101i) 125 mm dia. nominal bore
102ii) 100 mm dia. nominal bore
103Providing & fitting fixing of G.I flange (10mm wall thicknes) by welding with G.I / M.S pipe and placing position as per specification and the direction of the Engg-in-charge.
104i) 125 mm dia.
105i) 100 mm dia.
106Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.
107i) 125 mm dia.
108i) 100 mm dia.
109Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer incharge.
110Providing and fixing MS bolts including nuts andwashers complete as per standard design:-a) Upto 300mm length.

AI Tender Summary

OUR REF NO 40728221
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-11-2023
Authority
Authority Name Public Works Department
Work Description Dtw Schemes Under Nabard Xxvii ( Phase-Ii ) Under South Tripura District During The Year 2022-23 / Sh:- Construction Of 02 ( Two ) Nos. Semi-Permanent Pump House Of Size 4.00 Mtr X 3.00 Mtr, Installation Of Pump Motor In / C Panel Board, Electrical Equipments & Laying Of Upvc Distribution System Etc. For 2 ( Two ) Nos.Dtw Scheme I ) In The Land Of Nirmal Sarkar Under Durgapur G.P & Ii ) In The Land Of Ratan Aditya, Under South Srirampur G.P Rajnagar Rd Block
Basic Detail
Tender No 17/SE/WRC-III/UDP/DNIeT/23-24
Bidding Type Tender
Location
City South Tripura
State Tripura
Key Dates
Publish Date 20 Nov 2023
Submission Date 27 Nov 2023
Open Date 27 Nov 2023
Finance
Tender Value Ref. Documents
Tender Fee 1000
EMD 49691
Exemption Not Available
Document List
dfc37e71-7725-4d60-84ab-81a9ece0a7b8.html
annexure-I-IV-and-VI.pdf
BOQ_44722.xls
DNIeT-SE-17.pdf
Statement-I-III.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

dfc37e71-7725-4d60-84ab-81a9ece0a7b8.html

pdf

annexure-I-IV-and-VI.pdf

xls

BOQ_44722.xls

pdf

DNIeT-SE-17.pdf

pdf

Statement-I-III.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders