Tender For Repair Maint Of Dg Set Apfc Panels Voltage Stabilizer Improvement Of Borewell Rewinding Of Motors Pumps Starters Panels Comprehensive Maint Of Swimming Pool Misc Repair Of Stp Plant And Repair Chemical Cleaning Painting And Other Connected, gurgaon-Haryana

Military Engineer Services-MES has published Tender For Repair Maint Of Dg Set Apfc Panels Voltage Stabilizer Improvement Of Borewell Rewinding Of Motors Pumps Starters Panels Comprehensive Maint Of Swimming Pool Misc Repair Of Stp Plant And Repair Chemical Cleaning Painting And Other Connected. Submission Date for this Tender is 16-12-2023. Electrical Maintenance Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

40718246
Corrigendum : Tender For Repair Maint Of Dg Set Apfc Panels Voltage Stabilizer Improvement Of Borewell Rewinding Of Motors Pumps Starters Panels Comprehensive Maint Of Swimming Pool Misc Repair Of Stp Plant And Repair Chemical Cleaning Painting And Other Connected
Open Tender
Indian
Haryana
gurgaon
16-12-2023

Tender Details

Repair Maintenance Of Dg Set Apfc Panels Voltage Stabilizer Improvement Of Borewell Rewinding Of Motors Pumps Starters Panels Comprehensive Maint Of Swimming Pool Misc Repair Of Stp Plant And Repair Chemical Cleaning Painting And Other Connected Works Of Oht, Ug Sump At 2003 Stn Under Ge Af Gurgaon

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 97000.0 /-
Tender Value
INR 48.50 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT OF DG SET, APFC PANELS, VOLTAGE STABILIZER, IMPROVEMENT OF BOREWELL, REWINDING OF MOTORS, PUMPS, STARTERS, PANELS, COMPREHENSIVE MAINT OF SWIMMING POOL, MISC REPAIR OF STP PLANT AND REPAIR, CHEMICAL CLEANING, PAINTING AND OTHER CONNECTED WORKS OF OHT, UG SUMP AT 2003 STN UNDER GE AF GURGAON
Sl. No. Item Description
1Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified and as directed.
2M&L for rendering 10 mm thick in cement mortar (1:4) onbrick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
3M&L for rendering 5 mm thick in cement mortar (1:3) onbrick work or concrete surfaces of wall/ceiling finished even and smooth (without using extra cement) complete all as specified and as directed.
4M&L for rendering 20 mm thick in cement mortar (1:4) onbrick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
5M&L for preparation of newly plastered surfaces of wall andapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
6M & L for providing 1-2mm thick wall care putty on wall and applying two coats of Oil bound Distemper over a coat of primer including preparation of putty surface and making the surface uniform complete all as specified and as directed.
7M & L for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed.
8M & L for complete removal of existing treatment, providing 1-2mm thick wall care putty on wall and applying two coats of Oil bound Distemper over a coat of primer including preparation of putty surface and making the surface uniform complete all as specified and as directed.
9M & L for preparation of old treated ceiling surfaces and applying two coats of white wash complete all as specified and as directed.
10M&L for complete removal of existing treatment, preparation of surfaces of wall, chajja andapplying Two or more coats of 100% exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
11Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground level) complete all as specified and as directed.
12M&L for 75 mm thick PCC 1 :3 :6type C-1 (Using 20mm graded stone aggregate) as in plinth protection, laid panels and joints filled with bitumen sand mixture with wall, at 3.0mtr interval and at corners complete all as specified and as directed.
13M&L for 25 mm thick PCC 1 :2 :4type B-0 (Using 12.50mm graded stone aggregate) as in floor complete all as specified and as directed.
14Dismantling floor hearth or wall tilingincluding cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and as directed.
15M&L for Non- skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.11 but n.exc 0.18 Sqm, in floors/shirtingetc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed in CM 1:4 complete all as specified and as directed.
16M&L for Glazed ceramic coloured/ printed tiles in vertical surface of size 350x 250 x 7mm/450x 300 x 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on walls as in dado/ skirting etc over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed.
17S&F signage of aluminium composite panel not less than 3mm thick with high intensity prismatic reflective tape fixed to stainless steel frame work complete all as specified and as directed. Note: Stainless steel frame work shall be measured and paid seprately.
18S&F writing/fixing letters or figures (Block, roman, italic, Indian) 100mm high and 20mm width with high intensity prismatic reflectiv tape ASTM type IV sheetcomplete all as specified and as directed. Make: 3M, Averv, Dennison.
19S&F cautionary signs of road size (3"x3") of stainless steel sheet complete all as specified, as per manufacturers instructions and as directed. Note: Stainless steel frame work shall be measured and paid seprately.
20S&F cautionary signs of road size (2"x2") of stainless steel sheet complete all as specified, as per manufacturers instructions and as directed. Note: Stainless steel frame work shall be measured and paid seprately.
21Exacation in post holes or similar holes each not exc 0.50cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and ramming, surplus soil to a distance n. exc 50mtr and making good complete all as specified and as directed.
22M&L for cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) asin fdn filling and mass concretecomplete all as specified and as directed.
23M&L for stainless steel sections (SS-304grade) as in pillar/post/sides for sinages/facility information/cautionary signs etc incl embedding in concrete and screwing etc cutting top to shape as directed, drilling holes, notching, welding etc complete all as specified and as directed.
24M&L forDewatering OHT and making surface free from fungi by scrubbing, cleaningthoroughly forremovingthe dirts, sediments, silts etc from the internal surfaces of RCC over headtanks (bottom & wall) by using brushesand bleachingpowder and othercleaningmaterials as required andapplying two coats of lime wash insidethe surface of the tanks including writing the words" MILITARY ENGINEER SERVICES, TANK CAPACITY, DATE OF CLEANING AND DUE DATE OF CLEANING"in capital letters of suitable size on outside visible place of OH tank with synthetic enamel whitepaint over black back ground of 50,000 Gallons water tank complete all as specified and as directed. (Note: Main source OHT shall be cleaned 2 time a year)
25M&L forDewatering UG Sump and making surface free from fungi by scrubbing, cleaningthoroughly forremovingthe dirts, sediments, silts etc from the internal surfaces of RCC UG sumptanks (bottom & wall) by using brushesand bleachingpowder and othercleaningmaterials as required andapplying two coats of lime wash insidethe surface of the tanks including writing the words" MILITARY ENGINEER SERVICES, TANK CAPACITY, DATE OF CLEANING AND DUE DATE OF CLEANING"in capital letters of suitable size on outside visible place of UG sump tank with synthetic enamel whitepaint over black back ground of 1,00,000 litre water tank complete all as specified and as directed. (Note: Main source UG sump shall be cleaned 2 time a year)
26M&L for Cleaning of static tank of following capacity by providing pumping set& removing all muds, stones, other foreign materials etc washing with bleaching powder and applying a coat of colour washing for(internal and external portion) including repairing andpaintingof wire mesh and MS angle iron frame and writing the words" TANK CAPACITY AND DATE OF CLEANING"in capital letters of suitable size on outside visible place of Static tank with synthetic enamel whitepaint over black back ground and covering static tank with polyester green cloth used in arboriculture to prevent falling of wood & leaves from tree in tank complete all as specified and as directed of the following capacity:-
2722,000 Ltrs capacity at New MT Section & P-74
2824,000 Ltrs capacity at P-10 & FF Ph
2935,000 Ltrs capacity at Signal centre
3060,000 Ltrs capacity at helipad
31Testing of Water Samples for Chemical, bacteriological & metal analysis as mentioned below from User end and from the nearest point of OHT tank or as directed by Engineer-in-charge during delivery time for each month complete all as specified and as directed with following parameters:- (a)          PH, (b)          Specific Conductivity, (c)          Free Chloride (CL), (d)          Total Harness as Ca CO3, (e)          Iron as (FE), (f)           Arsenic (AS), (g)          Total dissolved solids , (h)Coliform, (i)E. Coli , (j) Colour, (k)Odour,(l) Taste, (m) Floride, (n)TDS, (o)Turbidity. NOTE: (a) Sample of Water for the above media test are to collected in transparent sterlized container/Jar/bottle (to be arranged by contractor) separately for each test against each pump houses. (Hygienically clean bottles) and proper sealing shall be done by contractor. (b) Sample of water to becollected before and after treatment shall be forwarded to Govt Lab approved &NABL accredited Lab for testing within spitulated time frame. No Extra payment shall done for transportation charges.
32S&F jointing and testing of cast iron sluice valve ISI mark (PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts washers and gaskets including taking down unserviceable sluice valve complete all as specified of size 80mm complete all as specified and as directed.
33S&F jointing and testing of cast iron sluice valve ISI mark (PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts washers and gaskets including taking down unserviceable sluice valve complete all as specified of size 100mm complete all as specified and as directed.
34S&F jointing and testing of cast iron sluice valve ISI mark (PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts washers and gaskets including taking down unserviceable sluice valve complete all as specified of size 150mm complete all as specified and as directed.
35M&L for construction of Valve pit chamber 90 cmx90cm (inner dimension) and 90 cm deep , from the top of MS cover fixed on PCC Base, top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including brick work with sub class"B" bricks in CM 1:4 including 15 mm thick plaster in CM 1:4 (internally and externally) and necessray earth work in anu type of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick PCC 1:4:8 , type D-2 , using 40mm graded stone aggregates as in floor complete all as specified and as directed. Note: Exacavation, returning, refilling etc is deemed to be included in quoted rate.
36Taking down carefullyaluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and as directed.
37Taking down carefully by unscrewing from theboards/outlets boxes fittings and fixturessuch as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbedsurfaces complete all as specified and as directed.
38Taking down unserviceable main switches MCB DB’s incl MCB SP/SPN/TPN of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and as directed.
39M&L for point wiring with 1.5 sqmm (Nominal area) 650/1100 volts, PVC insulated, unsheathed multistranded FRLS copper conductor cable in non metallicrigid PVCconcealedconduit medium gradewith allfittingsandaccessories including mounting piano switches,sockets, fan regulators etc complete including continous earth wire PVC insulated 1.5 sqmm copper multistrandedFRLSconductor connecting to commonearthand earth dolly complete all as specified and as directed for the following:-
40One fan/light point and exhaust fan point Wiring with copper conductor cables FRLS controlled by one way switch with cable 1.5 sqmm size.
41One socket outlet 5 Amps on the same board.
42S&F in replacement of socket outlet combination 2 in 1, 3 pin 5 Amps flush type universal complete all as specified and as directed.
43S&F in replacement of switch piano flush button Type 5 Amp SP one way complete all as specified and as directed.
44S&F in replacement of Pendant ordinary, comprising ceiling rose, brass with insulated body lamp holder, cord grip pattern, and 0.5 sq.mm copper flexible twisted twin cord up to 1.5m length as ordered complete all as specified and as directed.
45Supply and fixing in replacement of LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
46Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
47M&L for Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as that of the old oneinsulating, varnishing and pre heating for the following :-Note: Rates are deemed to be inclusive of replacing bush, bearing, armature & capacitor of any type, size & capacity, if required as per fan condition.
48(a) Ceiling fan 1200mm/1400mm sweep.
49(b) Exhaust fan 250mm upto 300 mm sweep.
50Supply and fixing capacitor of 2.5 MFD complete all as specifeid and as directed.
51M&L for Cleaning and preparing the surfaces of ceiling fan, wall mounted fan, exhaust fan, pedestal fan, removing the grease, carbon dust over the fans and painting with two coats of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan of suitable size complete all as specified and as directed.
52S&F in replacement of sheet metal enclosure for MCB"s (D.B) 4 way (SPN) 200 Amps, 240Vrated bus bar complete all as specified and as directed.
53S&F MCB class "B" 240 volts SP 10 Amp 10KA breaking capacity ISI marked, complete all as specified and as directed.
54S&F MCB class "B" 240 volts SPN 32 Amp 10KA breaking capacity ISI marked, complete all as specified and as directed.
55M&L for wiring sub main wiring concealed along with earth wire with the following size of HRFR PVC insulated and unsheathed multistranded copper conductor single core cable in concealed through 25 mm rigid not metallic PVC conduit heavy dutywith 2 x 1.5 sqmm + 1 x 1 sqmm earth wire complete all as specified and directed by Engineer-in-charge. including cutting chesses pinning in making good to facing and pointing in cement morter 1:3 to the ends or cutting chesses for conceled point wiring and making good distrubed surface complete cutting not exceeding 4 cm length and 4 cm width. Note:- Two run of cable and one length of PVC conduit with earth conductor shall be measured as a one length complete all as specified and as directed.
56Maintenace of STPs of following sizes including cleaning of Sewage syatem, sewage lines, rectifcation of sewage blockages etc complete to ensure smooth and trouble free operation of capacity 1.5 KLD all as specified and as mentioned below:-. i)Checking of regular parameters required for smooth operation of STP. ii)Ensure desired water quality and quantity. iii)All necessary measures to be taken for satisfactory operation of plant. iv)Regular cleaning of bar screen. v)Regular backwash and rinsing of Multi-grade filter, and Activated carbon filter. vi)To undertake regular preventive maintenance of the mechanical equipment’s such as pumps, valves etc and take corrective action in order to ensure smooth operation of the STP. vii)Checking of oil & grease and servicing of all blowers and gear boxes. viii)Physical monitoring of abnormal sound, alignment of pumps, motors, blowers, ix)To check and repair the Electrical LT panel including its components and it’s wiring for proper functioning. x) Clearing sludge bed on regular basis.
57Note: i) The rates quoted are deemed to be inclusive of Repairs and replacement of spares as and when required basis by employing trained manpower. How ever the items will be measured andpaid under relevant item of schedule ii) Contractor shall send trained technicians to make the plant opeartional within 3 to 4 hours by repairing the system in case of repair. Cost of replacement of spares shall be measured and paid under relevant items of schedule. Failure of operation of plant will be penalised @ Rs 1000/ per day. Suitable number of technicians shall be employed by the contractor to monitor the system on daily basis. No extra payment will be done on this account.
58Nature of effluent - Domestic Sewage from toilet, Kitchen waste water shall be discharged into the STP.
59INLET EFFLUENT CHARACTERSTICS
60DOMESTIC SEWAGE
61pH - 6.5 – 8.5
62BOD -250-400 Mg/L
63S. Solids -150-450 Mg/L
64COD -600-800 Mg/L
65Oil & Grease - upto 50Mg / L
66DISCHARGE EFFLUENT CHARACTERSTICS AFTER TREATMENT
67pH - 6.0 – 8.5
68BOD - Less than 30 Mg/L
69S. Solids - Less than 100 Mg/L
70COD - Less than100 Mg/L
71Oil & Grease - Less than 5 Mg / L
72Sewage treatment plant shall include the following items:-
73Grit chamber
74Screen Chamber
75Oil & Grease Trap
76Sewageequalization tank/sump
77Tube Settler Tank
78Sludge Holding Tank
79Air Blowers, Pumps & equipment
80Piping, valves etc
81Irrigation / Flushing Water tank
82Tertiary Treatment MGF/ACF
83Electrical Panel & Cabling
84Desludgingthe following existing chambers and getting out through sucking super soccer machine and depositing to a distance exceeding 1.5 KM out side defence land and cleaning with clean water and reuse for proper functioning complete all as specified and as directed. Note: Pumping out sludge water from MBBR tank by using diesel engineoperated pump is to be arranged by contractor complete all as specified and as directed of the following:-
85Sewage well
86Filter Feed tank
87MBBR tank
88Tube Settler Tank
89Chlorine tank
90Treated water tank
91Collection tank
92Screen Chamber
93Oil and grease Chamber (3 m3)
94S&F of air diffuser rod type at least 1mt long with rubber coating and SS mouth diffuser and SS clamps after removing water & sludge from equalizer tank & MBBR tank, complete all as specified and as directed. Note :-Contractor shall make alternative arrangement to meet the sewage disposal during the the desluding period. The rates quoted shall be deemed to inclusive of such arragement and no extra payment will be done on this account.
95M&L for Cleaning & Replacement ofunserviseble sand media fromsludge drying beds, and filling with clean and fine river sand or New Media forSludge Drying Bed in layers complete all as specified and as directed
96Supply only Bio Culture complete all as specified and as directed
97Supply only liquid chlorinecomplete all as specified and as directed
98Supply only MBBR media cylindrical with extended fin, black in colour of superior quality and UV stable complete all as specified and as directed
99M & L for servicing of air blowerwith positive displacement type twin lube root blower with Motor of Various capacities, including Opening the blower motor blower shaft and shaft Key ways, shaft holes etc andreplacing the gland packing, gland nuts, topping up engine lubrication oil andcoupling as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed
100M & L for installing electrical timer in existing electrical LT panel for air blower for auto working with inter-locking system between both air blowers.Time setting between both blower in manual way and including all accessories complete all as specified and as directed
101Labour only for lifting /taking out the non clogging sewage submersible pump set and motor ofcapacity upto 5 HP including column pipe of any bore bydismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage equalizer tank of depth up to 7 meter and loweringback the pump after repairing /removing the sludge from the pump including making electrical connection with the existing panel /starterand connecting the complete the column pipe assembly with nut ,Bolts,washers/packing to the existing header without any leakage complete all as specified and as directed. Note for:- Rate are deemed to be inclusive for jointing of Submersible Cable upto 7mtr, Steel wire of suitable gauge tied with motor before lowering down upto the depth of motor, reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete all as specified.
102M&L for rewinding of electric motormonoblock 3HP 50 HZ 400/415 volts of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed .
103M&L for rewinding of electric motor5HP , 50 HZ 400/415 volts of non clogging/ mono block/centrifugal elctric motor of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed .
104S&F PVC insulated flexible flat 3 core submersible cable with copper conductors of size 10 sqmm from control panel to non clogging motor for STP installation complete all as specified and as directed
105Testing of Sewage water as per relevant IS of STP & submission of detailed NABL approved laboratory test report to the office of the Engineer-in-charge must comprise of following specifications:- (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value, TSS, BOD,COD total nitrogen, sulphate, oil and grease ammonium Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water. Notes:- Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required. (ii) To and fro transportation charges for collection of sample
106Comprehensive Annual Maintenanceof swimming pool and Backwash filter system when needed (D.E. included) a qualified service technician will make 10 trip(s) every month to the location to perform the following service (weather permitting) complete all as specified and as directed:- 1. Clean tile in pool (cleaning suntan oils and organic materials from tile- not mineral deposits). 2. Clean strainer basket (as needed). 3. Vacuuming, leaf mastering or leaf raking of the pool (as needed). 4. Chemical testing of pool and balancing water with chlorine and acid (as needed). 5. Complete water analysis. 6. Skim water surface each visit. 7. Brush pool and walls of pool (as needed). 8. Care and maintenance of the filter equipment. 9. Elimination and control of an algae problem (additional charges required). 10. Refilling of chlorinator bucket and tubing adjustments (additional charge for tubing).
10711. Rainy day schedules shall consists only of chemical testing of the water, adding any necessary chemicals and checking the operation of all pool equipment. 12. Drain and refill and cleaning of Main Pool in each job. 13. Repair/ replacement of ‘O’ rings, PVC fitting upto 90mm dia like flange, Bend, Tee, Socket, Caps, Elbow, union rings, PVC Bush, Union, filter bucket O ring, waste collector bucket in filter bucket, transparent cap of filter bucket, weight sensor & caps etc. are included. 14. Repair/replacement of LT panel wiring, panel lock, ammeter, voltmeter, selector switch, push button and indication lamp. 15. Repairing to Foot valve of pump 250mm dia. 16. Checking, Oiling, greasing etc to pumps. Note - Comprehensive and preventive maintenance shall be carried out by contractor through trained engineers of authorised company only. The contracor shall submit the document of that authorised company to the department before doing work for approval. *Penalty of rs 1000/- will be recovered from the contractor if not visited the site and swimming pool not found functional adequately.
108M&L for dismantling the electric induction booster motor 3 phase 415 volt 50 HZ, 5 HP capacity and shifting to workshop for rewinding with super enameled copper wire of existing gauge of approved quality including varnishing including replacement of Bearing & bush as per siteand refixing at existing for swimming pool including connection,commissioning and testing complete, including transportation complete all as specified and as directed.
109M&L for repairing and testing swimming pool of booster motor pump5 HP ofmake- pentair and any type including welding work, turning, re-metaling of shaft bush bearing, key and other such accessories etc required to make pump functional and testing on load complete all as specified and as directed.
110Supply and fixing uncharged and non cogulant sand media and marble stone aggregate of suitable grade and size for pressure filter of size 1200mm dia made of MS floor mounted at swimming pool- 4 Nos , complete all as specified and as directed.
111M&L for removing old charged & cogulated sand media layer by layer including filter membranes and making new layers of sand, marble stone aggregate and filter membrane both vertical in center of vessel and between each layers sand and stone of suitable thickness and compressing it properly and the testing, commissiong filters complete all as specified and as directed. Note: (1) Rate of filter membrane of any size, type, grading and quantity as per existing is deemed to be included in quoted rate. (2) Rate are deemed to be inclusive of lifting arrangement of vessel like hydra, T&P and labour required at site. (3) Repair of minor defect encounter during overhauling of sand filter media filter is deemed to be included in quoted rate. (4) Acid and other cleaning agent required for cleaning of inner surface of vessel is deemed to included in quoted rate. (5) Rate are deemed to be inclusive of uPVC fittings (any type, size and quantity) required at site for disconnecting and refixing vessels after overhauling. (6) Rate are deemed to inclusive of repair to vessel if any damage caused to vessel and fitting due to mishandling by labour during execution of work.
112Supply and instlledmultiport valve suitable for uPVC pipe upto 75 mm dia with 6 way water flow, Side mounted on vessel with 360 degree rotating handle (made of high strength plastic), including valve to be properly consealed, tighten and leakage proof, complete all as specified and as directed.
113Supply and Fixing Butterfly valve of 90mm dia complete all as specified and as directed.
114Supply and fixing DOL starter along with auxillary block (Make: L&T cat: MNX A2) suitable for filteration pump of capacity 5HP along with wiring, complete all as specified and as directed.
115Supply and Fixing thermal relay of 4-10 Amp range complete all as specified and directed, along with wiring, complete all as specified and as directed.
116Supply and fixing single phase preventer suitable for 5HP pumpset along with wiring complete all as specified and as directed.
117Supply onlyforOT solution for chlorine test in500MLbottle complete all as specified and as directed.
118Supply only HARDNESS Test solution(3 btls x 500 ml Each )complete all as specified and as directed.
119Supply only PH test solution BTB or Phenol Red solution for pH test (500ml), complete all as specified and as directed.
120Supply and fixing water Pressure gauge of 100mm dia, complete with all accessories, complete all as specified and as directed.
121Supply only TCCA-90 ( Try chlorocynuricacid) complete all as specified and as directed.
122Supply only Soda Ash complete all as specified and as directed.
123Supply only CuSo4 powder (algaecide) type complete all as specified and as directed.
124Supply only NaH SO4 (Sodium Bi sulphate ) complete all as specified and as directed.
125Supply only Alum Crystal type complete all as specified and as directed.
126Supply only Altoch GP granuals complete all as specified and as directed.
127S&F in replacement of under water LED light 18 watt, DC supply type, as per on site and making complete system water proof by selant and rubber washers and necessary wiring work, complete all as specified and as directed. Note: Necessary arrangment like mapower, electrician, T&P, dewatering pump etc is deemed to be included in quoted rate.
128S&F pool under cleaning brush of superior quality enclosed in stainless steel enclosure of 36 inches in length, having eight wheels and provision for connection with suction sweeper hose and rope tie rings at both end of brush for manual operation with rope to remove coagulated sediments from pool, complete all as specified and as directed.
129S&F in replacement of swimming pool overflow grating tiles 8 inches single pin type ABS material complete all as specified and as directed.
130S&F in replacement of outdoor landscape lights for swimming pool perimeter area post top IP65 25 watt cap symmetrical light distribution spun aluminium lanscape illuminaire complete all as specified and as directed. Cat part no- RUBYPT25WLED757PSYMTOPC, HSN code-9405 Make- Havells or equivalent out of makes specified in list of makes.
131S&F in replacement of 1 Phase Indicating lamp LED type of RYB colour for all three phases round in shape of 22.5mm complete all as specified and as directed.
132S&F in replacement of MCCB 32Amp 16 KA3P 415 Volts ACfixedthermal/magnetic setting complete all as specified and as directed.
133S&F in replacement of 3 phase Digital meter havingVAF + PF Meter with CTs complete all as specified and as directed. Make: L&T Cat No: WL441010OOOO or equivalent out of makes specified in list of makes.
134S&F in replacement of CT"s for ammeter of rating 200/5A complete all as specified and as directed.
135M&L for disconnecting theelectric and water pipe connections for lifting/taking out the column pipe of any dia from the bore wellupto a depth of 90 metersand including submersible cable, SWR rope, submersible pump and motor of any capacity and size for carrying out the necessary repair work and lowering the pumpset motor alongwith column pipe, submersible cable, SWR rope after repair and connecting electric and water pipe connection as per existing etc complete all as specified and as directed.Note :-(i) Contractor shall take proper precautions while taking out and lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable.All necessary T&P and equipments required fo taking out and lowering of pump set etc shall be arranged by the contractor at his own cost.(ii) Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes / pump sets / submersible cable and making necessary connections and testing including reconnecting water supply system.The required materials like column pipe / submersible cable/ pump sets etc (new / old ) shall be provided by the department to contractor for fixing and lowering in bore wells.
136M&L for transporting the submersible motor / pump of any make and capacity to the workshop, opening of the motor after unscrewing nuts, bolts and washers, checking the serviceability of windings, electrically and manually, and transporting back to the existing site from workshop after carrying out the repair work, complete all as specified and as directed.
137M&L for rewinding of non clogging sewage Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wireincluding replacement of thrust plate , thrust block housing , bush, sleeves. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 07 Meter, Capacity of motor 5 HP complete all as specified and as directed.
138M&L for rewinding of fresh water Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire,including replacement of thrust plate , thrust block housing , bush, sleeves. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 07 Meter, Capacity of motor 10 HP to15 HP complete all as specified and as directed.
139M&L for rewinding of centrifugal pump motor of PIT Sump 25 HP capacity by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire,including replacement of thrust plate , thrust block housing , bush, sleeves. Making the winding leak proof & taking out the electric connection complete all as specified and as directed.
140M&L for repairing of pump of centrifugal motor of PIT Sump 25 HP capacity, bucket type for stages including servicing/repair/replacement of each bucket, sleeves, brass impeller, Thrust plate, bush - bearing of suitable size, glands, rotor rod etc. complete all as specified and directed.
141M & L forFully Automatic Star delta Starter In sheet Enclosure Type MU-2F Motor rating AC-3,Duty 415V, 50 Hz 3 Phase to 15 HP Motor, Relay range of 09-14 A including Ammeter and voltmeter inslalled on his boxas per existing after taking out old U/S complete all as specified and as directed.
142Supplying and connecting PVC insulated flexible flat 3 core submersible cable with copper conductors of size 10 sqmm from controle panel near bore hole to submersible pump set complete all as specified and as directed.
143M&L for repairing of pump, bucket type for submersible pumpset suitable for 10HP to 15HP of 13 stages including servicing/repair/replacement of each bucket, sleeves, brass impeller, Thrust plate, bush - bearing of suitable size, glands, rotor rod etc. complete all as specified and as directed.
144Supply and fixing rubber gasket sheet suitable for 80mm bore GI column pipecomplete all as specified and as directed.
145Supply and fixing medium grade GI column pipe of 80mm bore complete all as specified and as directed.
146S&F MS flange 12mm thick of internal bore of 80mm and outer dia of 135mm complete all as specified and as directed.
147M&L for welding MS flange on column pipe including making bore for nut bolts and groove cutting in flange for submersible cable run through grooves complete all as specified and as directed.
148Supply and fixing of nuts, bolts and washers complete all as specified and as directed.
149M&L for Development of bore well for improving the yield of bore well and to achieve sand free crystal clear water by means of air compressor not less than 630 CFM capacity by lowering 32 mm dia pipe up to the depth of not less than 260 feet . Development should be continuing by applying air jerk at required intervals. It also includes pouring of chemical to dissolve the compact rust, sand and other sediments. After development and achieving required result pipe and connected items shall be taken out from the bore well and removed sand shall be removed from the pump house building in all respect complete all as specified and as directed.
150M&L for Pea gravel of size 2 mm to 6 mm around the linear assembly from bottom to ground level complete all as specified and as directed.
151supply and fixing in replacementing of Well Cap of 300 mm bore pipe complete all as specified and as directed.
152S&F in replacement of Chemical Chlorine dosing pump of flow rate upto 6ltr per hour, diafram type, 230 V, 50 hz , single phase complete all as specified and as directed.
153S&F in replacement Rotor assembly with bearings brackets & Tolerance ring complete all as specified and as directed.
154S&F in replacement NRV 3/8" complete all as specified and as directed.
155S&F in replacement Injection ckeck valve 3/8" complete all as specified and as directed.
156S&F in replacement Weighted suction line stainer 3/8" complete all as specified and as directed.
157S&F in replacement3/8" whitesuction/dishcharge tubing complete all as specified and as directed.
158S&F in replacement Ferrule 1/4 " (pk of 24)for Decrin dosing pump complete all as specified and as directed. Make : Declibac, rmco or equivalent out of makes specified in list of makes.
159S&F in replacement Check valve duckbill onlyfor Decrin dosing pump complete all as specified and as directed. Make : Declibac, rmco or equivalent out of makes specified in list of makes.
160S&F in replacement gear motor 230V, 50 Hz completefor Decrin dosing pump complete all as specified and as directed. Make : Declibac, rmco or equivalent out of makes specified in list of makes.
161S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
162S&F in replacement MCCB 200 Amp 36 KA4P 415 Volts ACfixedthermal/magnetic setting complete all as specified and as directed.
163S&F in replacement 3 phase Digital meter havingVAF + PF Meter with CTs complete all as specified and as directed. Make: L&T Cat No: WL441010OOOO or equivalent out of makes specified in list of makes.
164S&F in replacement CT"s for ammeter of rating 200/5A complete all as specified and as directed.
165S&F in replacement 1 Phase Indicating lamp LED type of RYB colour for all three phases round in shape of 22.5mm complete all as specified and as directed. Make: L&T Cat No: 8531 or equivalent out of makes specified in list of makes.
166S&F in replacement MCCB 32Amp 16 KA3P 415 Volts ACfixedthermal/magnetic setting complete all as specified and as directed. Make: L&T Cat No: CM98944OOHO or equivalent out of makes specified in list of makes.
167S&F in replacementMCCB 32Amp 16 KA3P 415 Volts ACfixedthermal/magnetic setting complete all as specified and as directed.
168S&F in replacement Star delta starter 3 phase having relay range of 13-22 Amps complete all as specified and as directed.
169S&F in replacementSingle phase preventer Make: L&T Cat No: CS94824DOOO complete all as specified and as directed.
170S&F in replacement of4 Nos Aluminium Bus bar strip of rating 300 Amps @ 3 Kg per strip complete all as specified and as directed.
171M&L for Carry out "B" check and servicing of DG set as per OEM specification for DG set of 250KVA capacity, (including the cost of the following spares (quantity)all as per OEMand as directed. (i) Engine oil (ii) Spinon lube oil filter (iii) Fuel Filter Kit 1.1 Ltrs (iv) Coolant (v) Air cleaner Safety Element (vi) Air cleaner primary element (vii) K clean 1 ltrs (viii) Poly V belt 4PK/8PK (any type & length) (ix) Thermostat Element (x) Rubber hoses of any type with tie clips of suitable size (xi) Gaskets,glands, nut, bolts & washers (xii) Radiator cleaning from outside with pressure jet spray, chemical & brush (xiii) Cleaning of DG set engine within canopy and AMF panel (xiv) Air Filter (xv) Freight & labour charges Freight & labour charges
172Same as item No- 126,but for 160-140 KVA DG set.
173Same as item No- 126, but for 100 KVA DG set.
174Same as item No-126 ,but for70 KVA DG set or below.
175M&L for visiting of service engineer/ technician at site and inspecting DG set upto 250 KVA(including AMF panel problems, control unit/sensors, Engine, radiator, Alternator or any other type of complaint i.e. Mechanical, electrical or electronic or including all the three teams togather) and checking for fault/defect and noting down items required for rectification, including rectifying minor defect on site if possible, complete all as specified and as directed. Note: (i) visit for servicing of DG set shall not be considered in this item. (ii) Minor complaints occuring within one month after servicing of a particular DG set will not be considered in this item after lodging complaint to Contractor by Engineer-in-charge or JE. (iii) Visiting of Different technician i.e. electrical, mechanical, electronic orcombine of three for the same complaint will be considered as one visit or one complaint only.
176Dismantling of Fuel pump assembly and fuel injectors of any nos of engine for DG Set of capacity upto 250 KVA, and transporting it to workshop and Caliberation fuel pump & its fuel injection system and overhauling of pump valve, valve seat, Nozzel pin holes by metal deposition and machining on lathe machine, gasket, bolts etc.and refixing the same and commissioning till fuel consumption and quality & quantity of smoke is within permissible level complete all as specified & as directed.Note: Transportation charges are deemed to be included in quoted rates.
177Taking out of turbo charger from DG Set transportation to workshop for overhauling, repairing and replacement of turbo assembly including fan, gears and machining of vortex flow chamber of turbo & refixing to DG Set aand refixing the same and commissioning till fuel consumption, quality & quantity of smoke and load development/ sound of DG is satisfactory to EIC all as specified & asdirected.Note: Transportation charges are deemed to be included in quoted rates of specified capacity.
178M&L for Dismantling of radiator assembly of engine of following capacity, and transporting it to workshop (if required) from site otherwise performing job at site. thereafter cleaning fins and chocked tubes after draining out water, washing with caustic, descaling and brazing for water tube leakage, repalcing of copper tube of suitable length and and sizeand refixing the same properly by deploying sufficient numbers of labour and commissioning and again checking for leakage after running DG on Load and checking flow speed of water through it, complete all as specified & as directed of following capacity:- Note: Transportation charges are deemed to be included in quoted rates.
179(a)140 to 250 KVA
180(b)Upto 100 KVA
181M&L for Dismantling of Self Startermotor of any capacityfor DG Set of capacity upto 250 KVA, and transporting it to workshop and rewinding with suitable gauge of copper wire, overhauling, repair & replacement of gears, pinion & its locking arrangment, armature, Carbon plate, carbon bush & brush, Gears etcand and refixing the same and commissioning for the torque developed by it for starting DG Set, complete all as specified and as directed of the following capacity:- Note: Transportation charges and charges for dismantling & reconnecting electric cableof starter & synchronising with control unit are deemed to be included in quoted rates.
182(a)140 to 250 KVA (Suitable for 24 V)
183(b)Upto 100 KVA(Suitable for 12 V)
184S& F AVR S/F VARIABLE SPEED DCDGsuitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage for DG set upto 250 KVA as per OEM specifications, including wiring as per required at site after taking down old unserviceable one, complete all as specified and as directed.
185M&L for Dismantling of alternator of DG Set of capacity upto 250 KVA, and transporting it to workshop and rewinding, overhauling, repair & replacement of rewinding with suitable gauge of copper wire, gear, pinion, pulley, carbon bush & brush etc upto 250 KVA as per OEM specification,including belts, wiring, demounting as per required at site after taking down old unserviceable one, complete all as specified and as directed.
186Supply and fixing following spares parts upto 250 KVA DG Set: Note: Taking down old spare parts and connecting new one by deploying skill technician (mechanical, electrical, electronics or combination) including necessary nut, bolts, washers, wiring, thimbling, tagging etc. is deemed to be included in quoted rates for item no (a) to (ah).
187Water pump assembly Make: Kirloskar
188Flexible connection (crank case to pump)Make: Kirloskar
189Water pump pulley (2 grooves, 190 PCD) Make: Kirloskar
190Fresh water outlet connector on heat exchanger Make: Kirloskar
191Fresh water outlet connector on heat exchanger Make: Kirloskar
192Non return valve 1" BSPMake: Kirloskar
193Thermostat and housing assembly Make: Kirloskar
194MAGNETIC PICK UP 16X1.5 THREADING (UNITCH MAKE) for dg upto 250 KVA Make: Kirloskar
195Engine control unit EMS 907 including relay card, PCB& logic card) Make: Kirloskar
196CONTROL RELAY, 24 V D.C., THREE CHANNEL R.B. ELECTRONICS Make: Kirloskar
197RELAY BOARD UL MAKE 24 VDC 2CH. 2C/O (RELAY- OMRAN make: Kirloskar
198ENGINE WIRING ASSEMBLY SUITABLE FOR EMS 907 UNITMake: Kirloskar
199WIRING HARNESS FOR CPCB CANOPY WITH PRICOL PANEL Make: Kirloskar
200WIRING HARNESS ASSEMBLYWITH EMS 907 UNIT make: Kirloskar
201SENSOR UNIT(FOR ELEC TEMP GAUGE) Make: Kirloskar
202LUB OIL PRESSURE SENDOR 0.75 +/- 0.15 BAR TWO TERMINAL Make: kirloskar
203WATER TEMPERATURE SWITCH (NO/NC) Make: Kirloskar
204STOP SOLENOID assembly suitable for 12/24VMake: Kirloskar
205Thermostat element (74 Deg) make: kirloskar
206CURRENT TRANSFORMER (SET OF 3 CT) 300/5AMake: Kirloskar
207CURRENT TRANSFORMER (SET OF 3 CT) 500/5AMake: Kirloskar
208KG 934 controller unit make: Kirloskar
209Relay board 2 and 1/2 12 V DC Make: Kirloskar
210Engine wiring harness assembly with KG 934 Make: Kirloskar
211LEFT HAND LOCK WITH CATCHER (UPTO 82.5 KVA) Make: Kirloskar
212LEFT HAND LOCK WITH CATCHER ( 100 TO 600 KVA) Make: Kirloskar
213RIGHT HAND LOCK WITH CATCHER (UPTO 82.5 KVA) Make: Kirloskar
214RIGHT HAND LOCK WITH CATCHER (100 TO 600 KVA) Make: Kirloskar
215LEFT HAND HINGE Make: Kirloskar
216Right HAND HINGE Make: Kirloskar
217V BELT RAW EDGED COGGED.(LP1176) Make: Kiloskar
218FLEXIBLE LUB OIL PIPE(FOR REMOTE FILTER) Make: Kirloskar
219KG 545 controller unit make: Kirloskar
220ENGINE WIRING ASSEMBLY SUITABLE FOR EMS KG 545 UNITMake: Kirloskar
221M&L for cutting and removing burnt out AMF panel wiring and rewiring it with copper wire of solid/stranded conductor all as per existing size with proper labelling/tagging, new thimble/ termination, connecting all circuit & logical controls, repalcing relays, timers, sensors & signal reciever, removing carbon deposition on bus bars & terminals, repairing cable tray, rewiring and proper connection of AMF panel parameters with DG set safety control unit, replacing new CTs etc. Testing and commission of AMF panel in auto and manual mode and demostrating the functionality of all the safety parameter both from saftey control panel and AMF panel complete all as specified and as directed. NOTE: wiring, CTs, thimble, tagging, rewiring of DG set mounted safety control unit etc required are deemed to be in quoted rates.
222Supply and fixing of digital VAF + PF meter, Cl 1in square in size of 96mm x 96mm cross-section for DG sets suiatble for DG set upto 250 KVA, complete all as specified and as directed.
223Supply and fixing of DC Ammeter 0-30Amps of square in size of 96mm x 96mm cross-section, for DG sets suiatble for DG set upto 250 KVA, complete all as specified and as directed.
224Supply and fixing of "under/over voltage relay, 3 phase, 415 volts", for DG sets of capacity upto 250 KVA complete all as specified and as directed.
225Supply and fixing of "under/over voltage relay, single phase, 240 volts", (set of 3 for each phase in one panel) for DG sets of capacity upto 250 KVA complete all as specified and as directed.
226Supply and fixing of battery voltage relay 12/24 VDC suiatble for DG set upto 250 KVA, complete all as specified and as directed.
227Supply and fixing Three element overcurent and earth fault relay as per site suiatble for DG set upto 250 KVA, complete all as specified and as directed.
228Supply and fixing frequency relay as per site suiatble for DG set upto 250 KVA, complete all as specified and as directed.
229Supply and fixing engine start relay as per site suiatble for DG set upto 250 KVA, complete all as specified and as directed.
230Supply and fixing speed relay as per site suiatble for DG set upto 250 KVA, complete all as specified and as directed.
231S&F ammeter selector switch, 6 A, rotary type, single hole inerted, with display plate suitable for 250 KVA dg set, complete all as specified and as directed.
232S&F 3 phase Voltmeter selector switch, 6 A, rotary type, single hole inerted, with display plate suitable for 250 KVA dg set, complete all as specified and as directed.
233S&F 2 step selector switch, 16 A, rotary type, single hole inerted, with display plate suitable for 250 KVA dg set, complete all as specified and as directed.
234Supply and fixing of Fuse (HRC type) 400 amps, for DG sets of capacity upto 250 KVAcomplete all as specified and as directed.
235Supply and fixing LED lamp of any colour (Red, yellow, green and blue) suitable for 12/24 v DC & AC for DG sets of capacity upto 250 KVA, complete all as specified and as directed.
236Supply and fixing 250/200 Amp, 415 Volts,4 pole, 50 Hz Power contactor of coil voltage 240 Volts, including spring operated add-on block and spring operated locking block along with spread suitable to bear current upto 350 Amps complete all as specified and as directed.
237Supply and fixing 400 Amp, 415 Volts,3 pole, 50 Hz Power contactor, spreader suitable to bear current upto 500 Amps complete all as specified and asdirected..
238M&L for painting of automatic servo voltage stabilizer with existing colour, by usingspraying machine upto 400 KVA before cleaning/preparation of outer surface of transformer including writing of SM No, MES No. and capacity of transformerin red colour complete all as specified and as directed.
239M&L for Checking/ inspection on site of automatic servo Voltage satbilizer functionality and servicing it (i.e. Cleaning from inside & outside, greasing gears, Checking its automatic controls, PCB card, motor, checking for oil strength, Checking circuit connections, lamps, meters, output/ input current stabilization, thimbling/renewing heated/ burntout cable connection etc.) complete all as specified and as directed.
240M&L for disconnecting the defective automatic servo Voltage satbilizer of Capacity upto 300 KVA from incoming and outgoing cables and opening the stabilizers for checking the defects in winding coils by draining out transformer oil (if required and keeping the oil safe for re-use in containers provided by contractor) and making ready for transportationto workshop for repair (if required) and back to site including making connections and testing complete including replacement of gasket set unserviceable nuts & bolts, washer, packings complete all as specified and as directed.
241Transportation of unserviceableautomatic servo Voltage stabilizer to nearest workshop and return back for installation inits original position/location after repairing from workshop upto 300 KVA capacity complete all as specified and as directed. Note :- Rate is deemed to be inclusive of transportation & lifting, T&P and manpower charges.
242M&L for opening of top cover of voltage stablizer by unscrewing nut, bolts & washers etc and taking out core assy from tank by disconnecting incomming & outgoing LT side bushing studs to outside by dismantling the channel in workshop complete all as specified and as directed.
243M&L for removing the lamination in proper manner carefully for taking out serviceable/unserviceable primary and secondary coils from the limbs in workshop complete all as specified and as directed.
244M&L for inserting of LT coils on limbs rewinded here in before/old after cleaning of lamination in proper way after insulating the limbs with requisite insulating materials on limbs in between limbs/coils in workshop complete all as specified and as directed.
245M&L for rewinding of primary winding with copper wire DPC/super enameled high quality matching with existing gauge and impedance including requisite insulating paper/material in each layer or winding complete all as spcified and as directed.
246All as per item No 162 hereinbefore but secondary winding with copper wire complete all as specified and as directed.
247M&L for re-arranging the top cover by screwing nuts, bolts & washers lamination over coils in proper manner including fixing of top channelsoldering in between coils as necessary and brazing connection in workshop complete all as specified and as directed.
248Supply and fixing LT incomming and outgoing limbs/studs with insulator for voltage stablizer upto 300 KVA of any size in workshop capacity and structure as per site, complete all as specified and as directed.
249M&L for disconnecting & reconnecting and shifting within sub stations and renewing old connection of Voltage stablizer with new LT panel, complete all as specified and as directed.Note: Rate deemed to inclusive of any no of labour for lifting, T&P & material like aluminium thimble of any size forLT cable etcrequired for shifting of position with in sub-station and re-conneting.
250Supply and fix in replacement of micro switch for upto 300 KVA voltage stabiliser make as per site , complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
251Supply and fix in replacement DPDT switches for upto 300 KVA voltage stabiliser make as per site complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
252Supply and fix in replacement Auto mannual switch for upto 300 KVA voltage stabilisermake as per site, complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
253Supply and fix in replacement high and low voltage indicator for upto 300 KVA voltage stabiliser make as per site, complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
254Supply and fix in replacement of servo circuit card suitable for voltage stabilizer for upto 300 KVA voltage stabilisermakeas per site complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
255Supply and fix in replacement of dimmer coil suitable for for upto 300 KVA voltage stabiliser makeas per site complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
256Supply and fix in replacement of gear suitable for for upto 300 KVA voltage stabilisermake as per site complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
257Supply and fix in replacement of PCB holders suitable for for upto 300 KVA voltage stabiliser makeas per site, complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
258Supply and fix in replacement push button suitable for for upto 300 KVA voltage stabiliseras make per site, complete all as specified and as directed. Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.
259Supply and fix in replacement potentio meter suitable for for upto 300 KVA voltage stabiliser make as per site, complete all as specified and as directed.Make of Voltage stabiliser : ITE Gurgaon, Volina,Brent Fort electric India etc.