Jal Jeevan Mission ( Jjm ) -Water Supply Scheme - To Santhanpara, Rajakumary ( Part ) And Senapathy ( Part ) Panchayaths In Idukki District-Package Iv- Clear Water Pumping Main, Sump Cum Pump House, Glsr In Santhanpara Gp-General Civil Work, muvattupuzha-Kerala

Kerala Water Authority-KWA has published Jal Jeevan Mission ( Jjm ) -Water Supply Scheme - To Santhanpara, Rajakumary ( Part ) And Senapathy ( Part ) Panchayaths In Idukki District-Package Iv- Clear Water Pumping Main, Sump Cum Pump House, Glsr In Santhanpara Gp-General Civil Work. Submission Date for this Tender is 07-12-2023. Water Supply Project Tenders in muvattupuzha Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40718052
Corrigendum : Jal Jeevan Mission ( Jjm ) -Water Supply Scheme - To Santhanpara, Rajakumary ( Part ) And Senapathy ( Part ) Panchayaths In Idukki District-Package Iv- Clear Water Pumping Main, Sump Cum Pump House, Glsr In Santhanpara Gp-General Civil Work
Open Tender
Indian
Kerala
muvattupuzha
07-12-2023

Tender Details

Jal Jeevan Mission ( Jjm ) -Water Supply Scheme - To Santhanpara, Rajakumary ( Part ) And Senapathy ( Part ) Panchayaths In Idukki District-Package Iv- Clear Water Pumping Main, Sump Cum Pump House, Glsr In Santhanpara Gp-General Civil Work

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Nov-2023 270DATE EXTENSION Date 07-12-2023

Key Value

Document Fees
INR 16540 /-
EMD
INR 500000.0 /-
Tender Value
INR 11.13 Crore /-

BOQ Items

Work Name:Jal Jeevan Mission (JJM)-WSS - to Santhanpara, Rajakumary (Part) and Senapathy (Part) Panchayaths in Idukki District-Package IV- Clear Water Pumping Main, Sump cum pump house, GLSR in Santhanpara GP-General Civil Work
Sl. No. Item Description
1Supply and laying Clear water pumping main-Cost of materials
2100.98.118:Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia.
3100.98.117:Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.
4100.98.116:Supply of DI K9 Pipe Conforming to IS 8329/2000, 150mm Dia.
5OD182653/2023-2024:Supply of 150mm GI medium pipe
6OD182904/2023-2024:Supply of 100 mm GI(m) pipe
7OD182905/2023-2024:Specials for 100 mm GI pipe excluding GST(5% of cost of pipe)
8OD182909/2023-2024:Supplying 150 mm G.I Medium pipe specials
9100.98.441:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 40mm.
10100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
11100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
12100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
13100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.
14100.98.462:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm.
15Supply and laying Clear water pumping main-Working charges
16100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
17100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
18100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
19100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.
20100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
21100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
22OD196216/2023-2024:Dismantling manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer -in-Charge:<br>Bituminous road
2315.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
24100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore.
25100.12.11:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 150mm diameter nominal bore.
26OD196370/2023-2024:Testing 100mm GI/MS pipeline with potable water to the required test pressure
27OD196371/2023-2024:Testing 150mm GI/MS pipeline with potable water to the required test pressure
28100.14.2:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 150mm diameter Ductile Iron Class K-9 Pipes.
2918.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
3018.70.2:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes
31OD167295/2023-2024:Labour for cutting Ductile Iron pipe with steel saw.150 mm diameter Ductile Iron. pipe
32100.35.2: Testing 150mm DI/CI pipeline with potable water to the required test pressure 150 mm dia Observed Data derived from item no.1018 of PHED DATA
33100.14.3:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 200mm diameter Ductile Iron Class K-9 Pipes.
3418.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
3518.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
36OD167296/2023-2024:Labour for cutting DI pipe with steel saw 200 mm diameter of DI Pipe
37100.35.3:Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA
38100.14.4:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 250mm diameter Ductile Iron Class K-9 Pipes.
3918.30.6:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe
4018.70.4:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:250 mm dia pipes
41OD167297/2023-2024:Labour for cutting DI pipe with steel saw 250 mm diameter DI Pipe
42100.35.4:Testing 250mm DI/CI pipeline with potable water to the required test pressure . 250 mm dia Observed Data derived from item no.1022 of PHED DATA
43100.37.5.1:In situ fabrication of M.S. pipes of size 100mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
44100.37.5.2:Fabricating M.S. flanges of diameter 100mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
45100.37.5.3:Cutting 100mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
46100.37.5.4:Welding 100mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
47100.37.5.5:Grinding cut and weld edges of 100mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
48100.37.6.1:In situ fabrication of M.S. pipes of size 150mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
49100.37.6.2:Fabricating M.S. flanges of diameter 150mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
50100.37.6.3:Cutting 150mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
51100.37.6.4:Welding 150mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
52100.37.6.5:Grinding cut and weld edges of 150mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
53100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
54100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
55100.37.7.3:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
56100.37.7.4:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
57100.37.7.5:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
58100.37.8.1:In situ fabrication of M.S. pipes of size 250mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
59100.37.8.2:Fabricating M.S. flanges of diameter 250mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
60100.37.8.3:Cutting 250mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
61100.37.8.4:Welding 250mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
62100.37.8.5:Grinding cut and weld edges of 250mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
6318.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
6418.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
65100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
66100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
67100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
68100.31.1.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class I.
69100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
70100.32.2:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 40mm Single Acting Air Valve.
712.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
724.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
735.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
745.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars
755.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
765.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
77Construction of 0.5 LL Capacity steel storage tank Near Magna Peak
782.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
792.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
804.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
815.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
825.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
835.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
842.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
85OD167298/2023-2024:Supply of Sand including loading, unloading, transportation and other incidental charges as per the direction of departmental officers.1
86OD167299/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 50000 L(1Nos.) thickness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiplelayered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp;amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hotdip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness. Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The dimensions of the Tank shall be of 4.855m in diameter and 2.9m in height DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design valve outlet connection : i) Suitable size CI Flanged valve ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. One no. 100 mm, iii) One (1) scour drain outlet from the floor of the tank with isolation valve. One No. 100mm.TANK LINERS:Tank liners shall be purposedesigned and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to onepiece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&amp;39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre with food grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
87OD167300/2023-2024:Dowel bars - Supplying and providing MS dowel bars of size 16mm dia of 2m long (1m in rock and 1m in concrete) including drilling holes of 20mm dia and filling the gap with cement grout (.5kg/each) etc...
88Construction of 2.6LL Capacitysteel storage tank at Thondimala
892.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
902.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
912.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
924.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
935.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
945.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
955.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
962.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
97OD167301/2023-2024:Supply of Sand including loading, unloading, transportation and other incidental charges as per the direction of departmental officers.1
98OD167302/2023-2024:Supply, installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 260000 L(1Nos.) thickness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiplelayered PE sheet/membrane for the inner containment liner. The Tank Shell / Body the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hotdip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness. Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The dimensions of the Tank shall be of 8.739m in diameter and 4.3m in height DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design valve outlet connection : i) SuitableCI Flanged valve ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. One no. 100 mm, iii) One (1) scour drain outlet from the floor of the tank with isolation valve. One No. 100mm.TANK LINERS:Tank liners shall be purposedesigned and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to onepiece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&amp;39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre with food grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
99OD167303/2023-2024:Dowel bars - Supplying and providing MS dowel bars of size 16mm dia of 2m long (1m in rock and 1m in concrete) including drilling holes of 20mm dia and filling the gap with cement grout (.5kg/each) etc...
100Construction of 2.9LL Steel storage tank at Puthadi Top
1012.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
1024.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1035.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
1045.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1055.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1062.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
107OD167304/2023-2024:Supply of Sand including loading, unloading, transportation and other incidental charges as per the direction of departmental officers.1
108OD167305/2023-2024:Supply,installation and commissioning of a pre-engineered, pre-fabricated, factory manufactured steel storage Water Tank having a capacity of 2.9 LL(1Nos.) thickness of 0.6 mm, in multiple layers as required for the capacity and height of the tank and multiplelayered PE sheet/membrane for the inner containment liner. The Tank Shell / Body &amp;amp; the Liner material shall be manufactured in a facility certified and compliant to ISO 9001 - 2000 standards. The Tank shall be supplied with access points, penetrations for inlets, outlets, drains and fittings, overflow and drain, high and low water level indicators. All connections to the tanks shall be with flanged or threaded nozzles, placed to the KWA water mains TANK ROOF :The roof of the tank shall be of corrugated Galvalume sheet steel and shall be domed, with heavy- duty Hot-dip Galvanized truss frame for support, and capable of supporting 4-5 persons for maintenance and cleaning and tank shall have an access hatch with cover, on the roof, for operation and Maintenance TANK COVER :Tank covers shall be of approved galvanized vermin proof construction. Roof ends shall be fitted with suitable vermin-proofing tape or other material, to prevent ingress of dust and foreign objects. Covers shall be firmly fixed to the top edge of the tank with galvanized bolts and nuts. LADDERS :Tanks shall be provided with Hot dip Galvanized ladders internally or externally. External roof supports shall be of an appropriately designed Hot-dip galvanized Steel construction. Tanks shall comply with relevant spill level, air gap and overflow requirements relative to Effective Capacity. All nuts and bolts used for the panels shall be a minimum of 12mm size and hot-dip galvanized/Case hardened. The tank shall have a circular angle fixed around the total circumference of the tanks, at the top, of minimum 2 mm thickness. Tanks shall be properly flushed out with clean water prior to being brought into service TANK DIMENSIONS: The dimensions of the Tank shall be of 11.652m in diameter and 2.9m in height DESIGN LIFE: The tanks shall have a design life of 40 years. TANK CONNECTIONS: Standard design valve outlet connection : i) suitable size CI Flanged valve ii) Overflow connection including an Internal approved bell-mouth shaped bends to maximize the overflow capacity. One no. 100 mm, iii) One (1) scour drain outlet from the floor of the tank with isolation valve. One No. 100mm.TANK LINERS:Tank liners shall be purposedesigned and manufactured and shall comply to AS/NZS 4020 (Appendix A )of 2005 and ANSI/NSF 61 - 2008, Section 5 Certificates of compliance to above standards shall be furnished by the manufacturer of the tanks. Tank liners shall: i) Be factory manufactured to one piece construction, fabricated from multi-layer PE sheet, certified for potable drinking water, to (ANSI/ NSF 61) and duly UV Stabilized. ii) Be of PE (polyethylene) in multi-layer construction for strength, reinforced with woven scrim industrial fabric to prevent elongation and enhance tensile strength. The total liner material thickness shall be no less than 0.6 mm thick. The tensile strength shall not be less than 2266 N (warp) and 2495 N (weft) and heat sealing strength of 2056 N v) All the liner welded lap joints shall be strengthened with Metallocene encapsulating tape welded over the overlap. vi) The Metallocene tape shall cover and protect the exposed material at the edges of the liner joints to further prevent the ingress of water into the scrim. vii) Liners shall be positively and continuously attached to the top outer edge of the circumference of the tank to prevent entry of water from the runoff from the roof structure. viii) All liners on tanks over 2m in height shall have a continuous intermediate liner support designed out of nylon (or other material)cord, around the circumference of the tank, at vertical intervals corresponding to the level of each ring. ix) The intermediate liner support cords shall be firmly secured to the steel shell at each level, to prevent stress on the liner welded joints, and thereby eliminate possibility of failure CORROSSION PROTECTION. The tank structure shall have a secondary corrosion protection system using sacrificial magnesium anodes. The number of anodes, their location around the tank and the mass of each anode shall be designed for anode replacement frequency of five years. The anodes shall be installed external to the tank and concrete apron with their location marked with a suitably label-Cost for Tank steel with 10years guarantee includes shel l,Steel wall,steel domed roof,Zinc Alum steel&amp;39;,Cost for Poly ethylene infinity liner ,Geo synthetic Fibre with food grade plastics are used for inside coating and Support Arrangements,Cost for Fabricated items,attachments and accessories like steel ladder,Cost of Fabricated nozzles,over flow nozzles and drain arrangements, Cost for HDG nut and bolts,Freight Charges,Erection Installation and commissioning of tank components.
109OD167306/2023-2024:Dowel bars - Supplying and providing MS dowel bars of size 16mm dia of 2m long (1m in rock and 1m in concrete) including drilling holes of 20mm dia and filling the gap with cement grout (.5kg/each) etc...
110Construction of4LL Sump cum Pump house at Pooppara
1112.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
1122.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1132.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
114OD167312/2023-2024::DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
1154.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1165.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
1175.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
1185.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
11922.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
12022.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
1215.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1225.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
1235.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
1245.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
12550.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
12650.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
12713.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
12813.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
12913.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
13013.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13113.71:Lettering with black Japan pint of approved brand and manufacture
13210.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
133100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete.
1349.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
13510.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
136OD167313/2023-2024::Providing suitable size ventilating arrangements by using 100 mm CI vent cowls as per the direction of departmental officers
13721.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
13821.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
13921.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
14021.15.2:Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc.complete.Powder coated minimum thickness 50 micron aluminium
14118.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
142100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
143OD167314/2023-2024:Supplying and providing water level indicator to the tank using scale fabricated out of 2mm<br>thick MS plate with in the frame work of suitable size MS square tube, 160mm PVC pipe for guiding the float,<br>necessary pullies, suitable nylon thread for connecting float and level indicator, painting the entire structure,
144Construction of 0.4LL Sump cum Pump house at Erachilpara
1452.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
1462.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1472.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
148OD167307/2023-2024::DOWEL BARS_ Supplying and providing MS dowel bars of size 16 mm dia , 200 cm long including drilling holes of 20 mm dia to a depth of 100 cm in rock and filling the gap with cement grout (0.100kg/hole) etc complete
1494.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1507.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
1515.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
1525.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
1535.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
15422.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
15522.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
15650.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
15750.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
1585.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1595.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
1605.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
1615.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
16213.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
16313.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
16413.71:Lettering with black Japan pint of approved brand and manufacture
16510.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
166100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete.
1679.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
16810.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
16921.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
17021.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
17121.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
172OD167308/2023-2024:Supply conveyance ,installation testing and commissioning of36/40 W LED street/Yard light out put greater than105 lumen/watts 4000-6000K with IP66 protection with LED chip make cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load ,internal surge protection up to 8 kv and alluminium preasure die cast powder coated housing acryliccover complete with THD less than 10% power factor greater than 0.98 R0HS compliant duly wired up for use on 230v AC supply.Driver compartment should be separately accessible for maintanance(LM 79&80 Certificate from NABL acredited third party lab produced mentioning chip manufacturer)
173OD167309/2023-2024:Taking new electrical connection from KSEBL
174OD167310/2023-2024:Charges for Supply, Installation, Trial run and commissioning of CCTV cameras in Raw water pump houses which includes providing 2Nos 5 MP camera with motion sensor and 30m vision, 5 MP or Higher HD out DVR,1TB HDD,4G Router, Cable 10m,Rack, 500VA UPS, etc complete
17518.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
176100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
177OD167311/2023-2024:Supplying and providing water level indicator to the tank using scale fabricated out of 2mm<br>thick MS plate with in the frame work of suitable size MS square tube, 160mm PVC pipe for guiding the float,<br>necessary pullies, suitable nylon thread for connecting float and level indicator, painting the entire structure,
178Construction of3LL Sump cum Pump house at James padi
1792.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
1802.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1812.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
182OD167331/2023-2024:Dowel bars - Supplying and providing MS dowel bars of size 16mm dia of 2m long (1m in rock and 1m in concrete) including drilling holes of 20mm dia and filling the gap with cement grout (.5kg/each) etc...
1834.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1845.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
1855.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
1865.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
18750.6.1.3:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
18850.6.1.9:Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
18921.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
19021.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
19121.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
1925.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1935.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
1945.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
19513.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
19622.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
19722.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
19813.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
19913.71:Lettering with black Japan pint of approved brand and manufacture
20010.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
201100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete.
20210.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
2039.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
20418.26.1:Providing and laying flanged C.I. Standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Upto 300 mm dia
205OD167332/2023-2024:Supplying and providing water level indicator to the tank using scale fabricated out of 2mm<br>thick MS plate with in the frame work of suitable size MS square tube, 160mm PVC pipe for guiding the float,<br>necessary pullies, suitable nylon thread for connecting float and level indicator, painting the entire structure,
206100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
207Road restoration charges PWD/SH/NH
2083.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
2094.2.A.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-III -For lower sub-base - Mix in Place Method
2104.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
2115.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
2125.2.b:Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.
2135.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)
2145.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
2155.6.2.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - II (13.2 mm Nominal Size)
2165.7.1:Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.09 mm (Type-A) aggregates using viscosity grade bitumen ( VG - 30) to the required line, grade, and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour., laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to the required level and grade.
2175.8.a:Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder (VG 30) laid on the prepared surface and rolling with 8-10 tonne smooth wheeled steel roller. Grading I - 19 mm nominal chipping size
21812.4:Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
21912.8.B.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical SpecificationsPCC Grade M20
220Road restoration charges -LSGD
2213.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
2224.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1)(A) By Mix in Place MethodConstruction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(i) For Grading I Material
2234.9:Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.By Mechanical Means with 1 km lead
2245.1.1a:Prime Coat :- Low porosityProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
2255.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
2265.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.Case - I By Manual Means(II) Bitumen (S-65)
2275.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510A. By Manual Means :- Case - III : Type C(II) Bitumen (S-65)
22811.4.3.1:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III. P.C.C. grade M 20 (i) Nominal mix (1:2:4)
229Electrification works and Supply erection testing and commissioning of pump sets at Erachilpara
230OD167333/2023-2024:Supply, erection & commissioning of best quality KWA approved make ISI marked centrifugal pumpset having a 15 LPS discharge against 130 M head at its maximum efficiency working at 230/415V at 50 Hz, 1450 rpm with bronze impeller, stainless steel shaft, CI/SS pump casing with suitable type base plate, including suitable fully Automatic starter with dry run, under voltage, over voltage & over current protection relay, MS panel board with MCCB, ELCB, Capacitor, Indicator lamps, voltmeter, ammeter, change over switch etc suitable for the above motor pump set including necessary copper cable for wiring, earthing, suitable size GM/CI non return & sluice valves, suction & delivery connections etc as per ISI and IE regulations & KSEB standard and erected & trial run conducted for 7days as per the direction of dept. officers and 2 years of free maintenance. If any documentation is required, that should be arranged by the supplier.A). PUMP:- Supply , erection , testing and commissioning of Kirloskar reputed make centrifugal pumpsets with Bronze/SS impeller , SS shaft and CI pump casing with suitable type of base plate with coupling ,coupling guard foundation bolts and nuts etc. complete suitable for coupling the pump and motor above the base<br>plate etc complete including providing suitable concrete foundation including cost of cement , sand and metal etc complete the duty condition is as follows discharge -15 lps, total head - 130m,Speed -1460 rpm, <br>(B). MOTOR:- supply , erection , testing and commissioning of Kirloskar reputed make horizontal solid shaft foot mounted TEFC squaral cage induction motor suitable for the above pump working 3 phase 50HZ AC supply , working voltage<br>415 V / 3300 V . The motor shall confirm to IE2/IE3 as per IS 12615-2018 including providing suitable concrete foundation including cost of cement, sand and metal etc complete. Flexible coupling shall be used for coupling of pumps and motors<br>(C).STARTER:- Supply ,erection, testing and commissioning of dry type copper wound auto transformer having 40,60,80% taping mounded with powder coated 2 mm thick steel sheath dust and vermin proof floor mounted control cubical panel associated with in/out cable entry boxes for accommodating the following parameters for controlling functions of the the fully automatic auto transformer starter. suitable for above motor - L&T or equivalent reputed co. make MNX 225 contactor unit -1 No L&T or equivalent Co make MNX 95 contactor unit- 2 Nos Timer and supervisory trip relay 1 No OV/UV control relays Minilac or equivalent Co make single phasing preventer AVF digital meter 1 No and selector switch - 1 set ON/Off ,trip & 3 phase indication lamps, Digital or numerical motor protection relay Power Circuit wiring with 25 x 4mm PVC sleeve insulated copper bar and 2.5 sq.mm control wiring <br> (D).PANNEL BOARD :- Supply, erection,testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable rating of3 pole MCCB as incomer providing suitable size Aluminium bus bar inter connect the above MCCB and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. complete and provided with duplicate earth point as per CEA regulation and code of practice. the panel shall be fitted on a common base frame on suitable foundation <br>(E).CABLING WORK:- Supply, laying, testing and commissioning ofsuitable size Aluminium conductor armoured cables for the above pump set from panel board to starter andsuitable size cable through PVC pipe, flexible hose and accessories from starter to motor.considering energy conservation <br> ( F). EARTHING:- Supply of all material and providing duplicate earthing by 25 x 3mm copper strip on wall /column/floor/buried (Appx. 20 mtrs) in ground and giving double earthing to motor,starter,panel board etc. and connect with existing earthbus. As per IE standards <br> (G).CAPACITOR:- Supply,erection,testing and commissioning suitable rating of of heavy duty APP capacitor for the above motor to get unity<br>power factor . The capacitor shall confirm to IS 2834 <br> (H).VALVE:- Supply of suitable size best quality heavy duty ISI Marked CI double fanged sluice valve and Non return valve with suitable pressure rating.fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Pressure gauge on both suction and delivery side <br><br>(I).SUCTION AND DELIVERY PIPE CONNECTIONS:- Supply and fitting of suitable size best quality MS pipe of thickness not less than 8 mm for a total length of 8 m (approx). suitable for the above pump set and suitable size foot valve and connecting the suction pipe of size 200mm MS and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with 150mm MS pipe of thickness not less than 8 mm for a total length of 8 m (approx) , vales and suitable specials to connect with the pumping main
231OD167334/2023-2024:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1x28wT5 fitting with APF electronic ballast suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, high lumen tube .
232OD167335/2023-2024:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. As per Databook DAR Electrical-5.14.
233OD167336/2023-2024:25mm PVC Conduit- Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required. 25 mm .As per Databook DAR Electrical-1.21.2.
234OD167337/2023-2024:Wiring with 3x 4 sq mm FRLS PVC insulated copper conductor-Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existingsurface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm As per databook DAR Electrical-1.17.21.
235OD167338/2023-2024:12 Way MCB DB 240V-Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door. As per Databook DAR Electrical-2.3.3.
236OD167339/2023-2024:SPN 5-32A MCB-Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. Single pole and netural .As per Databook DAR Electrical-2.10.2.
237OD167340/2023-2024: DP Isolator 40A -Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 40 amps .As per Databook DAR Electrical-2.12.1.
238OD167341/2023-2024:RCCB DP 40A - Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuitbreaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps . As per Databook DAR Electrical 2.14.2.
239OD167342/2023-2024: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitableGI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B. As per Databook DAR Electrical 1.10.2.
240OD167343/2023-2024:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. As per Data book Electrical 5.6
241OD167344/2023-2024:Expenses of getting electrical connection from KSEB including documentation fee, service charges, energizationcharges etc
242OD167345/2023-2024:Supply, conveyance, installation and commissioning of light duty Exhaust fan of 300/305mm sweep in metal frame working on 230V A/C 300 sweep including making good the damages etc as required as directed by the departmental officers
243OD167346/2023-2024:Supply conveyance ,installation testing and commissioning of36/40 W LED street/Yard light out put greater than105 lumen/watts 4000-6000K with IP66 protection with LED chip make cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load ,internal surge protection up to 8 kv and alluminium preasure die cast powder coated housing acryliccover complete with THD less than 10% power factor greater than 0.98 R0HS compliant duly wired up for use on 230v AC supply.Driver compartment should be separately accessible for maintanance(LM 79&80 Certificate from NABL acredited third party lab produced mentioning chip manufacturer)
244OD167347/2023-2024:Supply , delivery and fixing of 3 T or suitable capacity Electrically and manually working on single girder with overhead travelling trolley and clear lift as per site conditions for lifting the chemicals, Chlorine, pumps etc.. and fitting as required, supplied with one set of crane slings with GI D shackle and clamps etc. complete as per the instruction of the Engineer in charge.<br>
245Electrification works and Supply erection testing and commissioning of pump sets at Poopara
246OD167315/2023-2024:Supply, erection & commissioning of best quality KWA approved make ISI marked centrifugal pumpset having a 15 LPS discharge against 145 M head at its maximum efficiency working at 230/415V at 50 Hz, 1450 rpm with bronze impeller, stainless steel shaft, CI/SS pump casing with suitable type base plate, including suitable fully Automatic starter with dry run, under voltage, over voltage & over current protection relay, MS panel board with MCCB, ELCB, Capacitor, Indicator lamps, voltmeter, ammeter, change over switch etc suitable for the above motor pump set including necessary copper cable for wiring, earthing, suitable size GM/CI non return & sluice valves, suction & delivery connections etc as per ISI and IE regulations & KSEB standard and erected & trial run conducted for 7days as per the direction of dept. officers and 2 years of free maintenance. If any documentation is required, that should be arranged by the supplier.A). PUMP:- Supply , erection , testing and commissioning of Kirloskar reputed make centrifugal pumpsets with Bronze/SS impeller , SS shaft and CI pump casing with suitable type of base plate with coupling ,coupling guard foundation bolts and nuts etc. complete suitable for coupling the pump and motor above the base<br>plate etc complete including providing suitable concrete foundation including cost of cement , sand and metal etc complete the duty condition is as follows discharge - 15 lps, total head - 145m,Speed -1460 rpm, <br> (B). MOTOR:- supply , erection , testing and commissioning of Kirloskar reputed make horizontal solid shaft foot mounted TEFC squaral cage induction motor suitable for the above pump working 3 phase 50HZ AC supply , working voltage<br>415 V / 3300 V . The motor shall confirm to IE2/IE3 as per IS 12615-2018 including providing suitable concrete foundation including cost of cement, sand and metal etc complete. Flexible coupling shall be used for coupling of pumps and motors<br> (C).STARTER:- Supply ,erection, testing and commissioning of dry type copper wound auto transformer having 40,60,80% taping mounded with powder coated 2 mm thick steel sheath dust and vermin proof floor mounted control cubical panel associated with in/out cable entry boxes for accommodating the following parameters for controlling functions of the the fully automatic auto transformer starter. suitable for above motor - L&T or equivalent reputed co. make MNX 225 contactor unit -1 No L&T or equivalent Co make MNX 95 contactor unit- 2 Nos Timer and supervisory trip relay 1 No OV/UV control relays Minilac or equivalent Co make single phasing preventer AVF digital meter 1 No and selector switch - 1 set ON/Off ,trip & 3 phase indication lamps, Digital or numerical motor protection relay Power Circuit wiring with 25 x 4mm PVC sleeve insulated copper bar and 2.5 sq.mm control wiring <br> (D).PANNEL BOARD :- Supply, erection,testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable rating of3 pole MCCB as incomer providing suitable size Aluminium bus bar inter connect the above MCCB and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. complete and provided with duplicate earth point as per CEA regulation and code of practice. the panel shall be fitted on a common base frame on suitable foundation <br>(E).CABLING WORK:- Supply, laying, testing and commissioning ofsuitable size Aluminium conductor armoured cables for the above pump set from panel board to starter andsuitable size cable through PVC pipe, flexible hose and accessories from starter to motor.considering energy conservation <br> ( F). EARTHING:- Supply of all material and providing duplicate earthing by 25 x 3mm copper strip on wall /column/floor/buried (Appx. 20 mtrs) in ground and giving double earthing to motor,starter,panel board etc. and connect with existing earthbus. As per IE standards <br> (G).CAPACITOR:- Supply,erection,testing and commissioning suitable rating of of heavy duty APP capacitor for the above motor to get unity<br>power factor . The capacitor shall confirm to IS 2834 <br> (H).VALVE:- Supply of suitable size best quality heavy duty ISI Marked CI double fanged sluice valve and Non return valve with suitable pressure rating.fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Pressure gauge on both suction and delivery side <br><br> (I).SUCTION AND DELIVERY PIPE CONNECTIONS:- Supply and fitting of suitable size best quality MS pipe of thickness not less than 8 mm for a total length of 8 m (approx). suitable for the above pump set and suitable size foot valve and connecting the suction pipe of size 200mm MS and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with 150mm MS pipe of thickness not less than 8 mm for a total length of 8 m (approx) , vales and suitable specials to connect with the pumping main
247OD167316/2023-2024:Supply, erection & commissioning of best quality KWA approved make ISI marked centrifugal pumpset having a 3 LPS discharge against 180 M head at its maximum efficiency working at 230/415V at 50 Hz, 1450 rpm with bronze impeller, stainless steel shaft, CI/SS pump casing with suitable type base plate, including suitable fully Automatic starter with dry run, under voltage, over voltage & over current protection relay, MS panel board with MCCB, ELCB, Capacitor, Indicator lamps, voltmeter, ammeter, change over switch etc suitable for the above motor pump set including necessary copper cable for wiring, earthing, suitable size GM/CI non return & sluice valves, suction & delivery connections etc as per ISI and IE regulations & KSEB standard and erected & trial run conducted for 7days as per the direction of dept. officers and 2 years of free maintenance. If any documentation is required, that should be arranged by the supplier.A). PUMP:- Supply , erection , testing and commissioning of Kirloskar reputed make centrifugal pumpsets with Bronze/SS impeller , SS shaft and CI pump casing with suitable type of base plate with coupling ,coupling guard foundation bolts and nuts etc. complete suitable for coupling the pump and motor above the base<br>plate etc complete including providing suitable concrete foundation including cost of cement , sand and metal etc complete the duty condition is as follows discharge - 3 lps, total head - 180m,Speed -1460 rpm, <br> (B). MOTOR:- supply , erection , testing and commissioning of Kirloskar reputed make horizontal solid shaft foot mounted TEFC squaral cage induction motor suitable for the above pump working 3 phase 50HZ AC supply , working voltage<br>415 V / 3300 V . The motor shall confirm to IE2/IE3 as per IS 12615-2018 including providing suitable concrete foundation including cost of cement, sand and metal etc complete. Flexible coupling shall be used for coupling of pumps and motors<br> (C).STARTER:- Supply ,erection, testing and commissioning of dry type copper wound auto transformer having 40,60,80% taping mounded with powder coated 2 mm thick steel sheath dust and vermin proof floor mounted control cubical panel associated with in/out cable entry boxes for accommodating the following parameters for controlling functions of the the fully automatic auto transformer starter. suitable for above motor - L&T or equivalent reputed co. make MNX 225 contactor unit -1 No L&T or equivalent Co make MNX 95 contactor unit- 2 Nos Timer and supervisory trip relay 1 No OV/UV control relays Minilac or equivalent Co make single phasing preventer AVF digital meter 1 No and selector switch - 1 set ON/Off ,trip & 3 phase indication lamps, Digital or numerical motor protection relay Power Circuit wiring with 25 x 4mm PVC sleeve insulated copper bar and 2.5 sq.mm control wiring <br> (D).PANNEL BOARD :- Supply, erection,testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable rating of3 pole MCCB as incomer providing suitable size Aluminium bus bar inter connect the above MCCB and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. complete and provided with duplicate earth point as per CEA regulation and code of practice. the panel shall be fitted on a common base frame on suitable foundation <br>(E).CABLING WORK:- Supply, laying, testing and commissioning ofsuitable size Aluminium conductor armoured cables for the above pump set from panel board to starter andsuitable size cable through PVC pipe, flexible hose and accessories from starter to motor.considering energy conservation <br> ( F). EARTHING:- Supply of all material and providing duplicate earthing by 25 x 3mm copper strip on wall /column/floor/buried (Appx. 20 mtrs) in ground and giving double earthing to motor,starter,panel board etc. and connect with existing earthbus. As per IE standards <br> (G).CAPACITOR:- Supply,erection,testing and commissioning suitable rating of of heavy duty APP capacitor for the above motor to get unity<br>power factor . The capacitor shall confirm to IS 2834 <br> (H).VALVE:- Supply of suitable size best quality heavy duty ISI Marked CI double fanged sluice valve and Non return valve with suitable pressure rating.fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Pressure gauge on both suction and delivery side <br><br> (I).SUCTION AND DELIVERY PIPE CONNECTIONS:- Supply and fitting of suitable size best quality MS pipe of thickness not less than 8 mm for a total length of 8 m (approx). suitable for the above pump set and suitable size foot valve and connecting the suction pipe of size 200mm MS and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with 150mm MS pipe of thickness not less than 8mm for a total length of 8 m (approx) , vales and suitable specials to connect with the pumping main (15% RATE)
248OD167317/2023-2024:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1x28wT5 fitting with APF electronic ballast suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, high lumen tube .
249OD167318/2023-2024:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. As per Databook DAR Electrical-5.14.
250OD167319/2023-2024:25mm PVC Conduit- Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required. 25 mm .As per Databook DAR Electrical-1.21.2.
251OD167320/2023-2024:Wiring with 3x 4 sq mm FRLS PVC insulated copper conductor-Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existingsurface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm As per databook DAR Electrical-1.17.21.
252OD167321/2023-2024:12 Way MCB DB 240V-Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door. As per Databook DAR Electrical-2.3.3.
253OD167322/2023-2024:SPN 5-32A MCB-Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. Single pole and netural .As per Databook DAR Electrical-2.10.2.
254OD167323/2023-2024: DP Isolator 40A -Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 40 amps .As per Databook DAR Electrical-2.12.1.
255OD167324/2023-2024:RCCB DP 40A - Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuitbreaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps . As per Databook DAR Electrical 2.14.2.
256OD167325/2023-2024: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitableGI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B. As per Databook DAR Electrical 1.10.2.
257OD167326/2023-2024:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. As per Data book Electrical 5.6
258OD167327/2023-2024:Expenses of getting electrical connection from KSEB including documentation fee, service charges, energizationcharges etc
259OD167328/2023-2024:Supply, conveyance, installation and commissioning of light duty Exhaust fan of 300/305mm sweep in metal frame working on 230V A/C 300 sweep including making good the damages etc as required as directed by the departmental officers
260OD167329/2023-2024:Supply conveyance ,installation testing and commissioning of36/40 W LED street/Yard light out put greater than105 lumen/watts 4000-6000K with IP66 protection with LED chip make cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load ,internal surge protection up to 8 kv and alluminium preasure die cast powder coated housing acryliccover complete with THD less than 10% power factor greater than 0.98 R0HS compliant duly wired up for use on 230v AC supply.Driver compartment should be separately accessible for maintanance(LM 79&80 Certificate from NABL acredited third party lab produced mentioning chip manufacturer)
261OD167330/2023-2024:Supply , delivery and fixing of 3 T or suitable capacity Electrically and manually working on single girder with overhead travelling trolley and clear lift as per site conditions for lifting the chemicals, Chlorine, pumps etc.. and fitting as required, supplied with one set of crane slings with GI D shackle and clamps etc. complete as per the instruction of the Engineer in charge.<br>
262Electrification works and Supply erection testing and commissioning of pump sets at Jamespadi
263OD167348/2023-2024:Supply, erection & commissioning of best quality KWA approved make ISI marked centrifugal pumpset having a 17 LPS discharge against 140 M head at its maximum efficiency working at 230/415V at 50 Hz, 1450 rpm with bronze impeller, stainless steel shaft, CI/SS pump casing with suitable type base plate, including suitable fully Automatic starter with dry run, under voltage, over voltage & over current protection relay, MS panel board with MCCB, ELCB, Capacitor, Indicator lamps, voltmeter, ammeter, change over switch etc suitable for the above motor pump set including necessary copper cable for wiring, earthing, suitable size GM/CI non return & sluice valves, suction & delivery connections etc as per ISI and IE regulations & KSEB standard and erected & trial run conducted for 7days as per the direction of dept. officers and 2 years of free maintenance. If any documentation is required, that should be arranged by the supplier. A). PUMP:- Supply , erection , testing and commissioning of Kirloskar reputed make centrifugal pumpsets with Bronze/SS impeller , SS shaft and CI pump casing with suitable type of base plate with coupling ,coupling guard foundation bolts and nuts etc. complete suitable for coupling the pump and motor above the base<br>plate etc complete including providing suitable concrete foundation including cost of cement , sand and metal etc complete the duty condition is as follows discharge - 17 lps, total head - 140m,Speed -1460 rpm, <br> (B). MOTOR:- supply , erection , testing and commissioning of Kirloskar reputed make horizontal solid shaft foot mounted TEFC squaral cage induction motor suitable for the above pump working 3 phase 50HZ AC supply , working voltage<br>415 V / 3300 V . The motor shall confirm to IE2/IE3 as per IS 12615-2018 including providing suitable concrete foundation including cost of cement, sand and metal etc complete. Flexible coupling shall be used for coupling of pumps and motors<br> (C).STARTER:- Supply ,erection, testing and commissioning of dry type copper wound auto transformer having 40,60,80% taping mounded with powder coated 2 mm thick steel sheath dust and vermin proof floor mounted control cubical panel associated with in/out cable entry boxes for accommodating the following parameters for controlling functions of the the fully automatic auto transformer starter. suitable for above motor - L&T or equivalent reputed co. make MNX 225 contactor unit -1 No L&T or equivalent Co make MNX 95 contactor unit- 2 Nos Timer and supervisory trip relay 1 No OV/UV control relays Minilac or equivalent Co make single phasing preventer AVF digital meter 1 No and selector switch - 1 set ON/Off ,trip & 3 phase indication lamps, Digital or numerical motor protection relay Power Circuit wiring with 25 x 4mm PVC sleeve insulated copper bar and 2.5 sq.mm control wiring <br> (D).PANNEL BOARD :- Supply, erection,testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable rating of3 pole MCCB as incomer providing suitable size Aluminium bus bar inter connect the above MCCB and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. complete and provided with duplicate earth point as per CEA regulation and code of practice. the panel shall be fitted on a common base frame on suitable foundation <br>(E).CABLING WORK:- Supply, laying, testing and commissioning ofsuitable size Aluminium conductor armoured cables for the above pump set from panel board to starter andsuitable size cable through PVC pipe, flexible hose and accessories from starter to motor.considering energy conservation <br> ( F). EARTHING:- Supply of all material and providing duplicate earthing by 25 x 3mm copper strip on wall /column/floor/buried (Appx. 20 mtrs) in ground and giving double earthing to motor,starter,panel board etc. and connect with existing earthbus. As per IE standards <br> (G).CAPACITOR:- Supply,erection,testing and commissioning suitable rating of of heavy duty APP capacitor for the above motor to get unity<br>power factor . The capacitor shall confirm to IS 2834 <br> (H).VALVE:- Supply of suitable size best quality heavy duty ISI Marked CI double fanged sluice valve and Non return valve with suitable pressure rating.fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Pressure gauge on both suction and delivery side <br><br> (I).SUCTION AND DELIVERY PIPE CONNECTIONS:- Supply and fitting of suitable size best quality MS pipe of thickness not less than 8 mm for a total length of 8 m (approx). suitable for the above pump set and suitable size foot valve and connecting the suction pipe of size 200mm MS and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with 150mm MS pipe of thickness not less than 8mm for a total length of 8 m (approx) , vales and suitable specials to connect with the pumping main
264OD167349/2023-2024:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1x28wT5 fitting with APF electronic ballast suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, high lumen tube .
265OD167350/2023-2024:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. As per Databook DAR Electrical-5.14.
266OD167351/2023-2024:25mm PVC Conduit- Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required. 25 mm .As per Databook DAR Electrical-1.21.2.
267OD167352/2023-2024:Wiring with 3x 4 sq mm FRLS PVC insulated copper conductor-Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existingsurface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm As per databook DAR Electrical-1.17.21.
268OD167353/2023-2024:12 Way MCB DB 240V-Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door. As per Databook DAR Electrical-2.3.3.
269OD167354/2023-2024:SPN 5-32A MCB-Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. Single pole and netural .As per Databook DAR Electrical-2.10.2.
270OD167355/2023-2024: DP Isolator 40A -Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 40 amps .As per Databook DAR Electrical-2.12.1.
271OD167356/2023-2024:RCCB DP 40A - Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuitbreaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps . As per Databook DAR Electrical 2.14.2.
272OD167357/2023-2024: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitableGI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B. As per Databook DAR Electrical 1.10.2.
273OD167358/2023-2024:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. As per Data book Electrical 5.6
274OD167359/2023-2024:Expenses of getting electrical connection from KSEB including documentation fee, service charges, energizationcharges etc
275OD167360/2023-2024:Supply, conveyance, installation and commissioning of light duty Exhaust fan of 300/305mm sweep in metal frame working on 230V A/C 300 sweep including making good the damages etc as required as directed by the departmental officers
276OD167361/2023-2024:Supply conveyance ,installation testing and commissioning of36/40 W LED street/Yard light out put greater than105 lumen/watts 4000-6000K with IP66 protection with LED chip make cree/Lumilled/Nichea with powerfactor greater than 0.95 at full load ,internal surge protection up to 8 kv and alluminium preasure die cast powder coated housing acryliccover complete with THD less than 10% power factor greater than 0.98 R0HS compliant duly wired up for use on 230v AC supply.Driver compartment should be separately accessible for maintanance(LM 79&80 Certificate from NABL acredited third party lab produced mentioning chip manufacturer)
277OD167362/2023-2024:Supply , delivery and fixing of 3 T or suitable capacity Electrically and manually working on single girder with overhead travelling trolley and clear lift as per site conditions for lifting the chemicals, Chlorine, pumps etc.. and fitting as required, supplied with one set of crane slings with GI D shackle and clamps etc. complete as per the instruction of the Engineer in charge.<br>
278Supply erection testing and commissioning of pump sets at Poopara for magnapeak
279OD167977/2023-2024:Supply, erection &amp; commissioning of best quality KWA approved make ISI marked centrifugal pumpset having a 3 LPS discharge against 176 M head at its maximum efficiency working at 230/415V at 50 Hz, 1450 rpm with bronze impeller, stainless steel shaft, CI/SS pump casing with suitable type base plate, including suitable fully Automatic starter with dry run, under voltage, over voltage &amp; over current protection relay, MS panel board with MCCB, ELCB, Capacitor, Indicator lamps, voltmeter, ammeter, change over switch etc suitable for the above motor pump set including necessary copper cable for wiring, earthing, suitable size GM/CI non return &amp; sluice valves, suction &amp; delivery connections etc as per ISI and IE regulations &amp; KSEB standard and erected &amp; trial run conducted for 7days as per the direction of dept. officers and 2 years of free maintenance. If any documentation is required, that should be arranged by the supplier. A). PUMP:- Supply , erection , testing and commissioning of Kirloskar reputed make centrifugal pumpsets with Bronze/SS impeller , SS shaft and CI pump casing with suitable type of base plate with coupling ,coupling guard foundation bolts and nuts etc. complete suitable for coupling the pump and motor above the base&lt;br&gt;plate etc complete including providing suitable concrete foundation including cost of cement , sand and metal etc complete the duty condition is as follows discharge - 3 lps, total head - 176m,Speed -1460 rpm, &lt;br&gt; (B). MOTOR:- supply , erection , testing and commissioning of Kirloskar reputed make horizontal solid shaft foot mounted TEFC squaral cage induction motor suitable for the above pump working 3 phase 50HZ AC supply , working voltage&lt;br&gt;415 V / 3300 V . The motor shall confirm to IE2/IE3 as per IS 12615-2018 including providing suitable concrete foundation including cost of cement, sand and metal etc complete. Flexible coupling shall be used for coupling of pumps and motors&lt;br&gt; (C).STARTER:- Supply ,erection, testing and commissioning of dry type copper wound auto transformer having 40,60,80% taping mounded with powder coated 2 mm thick steel sheath dust and vermin proof floor mounted control cubical panel associated with in/out cable entry boxes for accommodating the following parameters for controlling functions of the the fully automatic auto transformer starter. suitable for above motor - L&amp;T or equivalent reputed co. make MNX 225 contactor unit -1 No L&amp;T or equivalent Co make MNX 95 contactor unit- 2 Nos Timer and supervisory trip relay 1 No OV/UV control relays Minilac or equivalent Co make single phasing preventer AVF digital meter 1 No and selector switch - 1 set ON/Off ,trip &amp; 3 phase indication lamps, Digital or numerical motor protection relay Power Circuit wiring with 25 x 4mm PVC sleeve insulated copper bar and 2.5 sq.mm control wiring &lt;br&gt; (D).PANNEL BOARD :- Supply, erection,testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable rating of 3 pole MCCB as incomer providing suitable size Aluminium bus bar inter connect the above MCCB and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. complete and provided with duplicate earth point as per CEA regulation and code of practice. the panel shall be fitted on a common base frame on suitable foundation &lt;br&gt;(E).CABLING WORK:- Supply, laying, testing and commissioning of suitable size Aluminium conductor armoured cables for the above pump set from panel board to starter and suitable size cable through PVC pipe, flexible hose and accessories from starter to motor.considering energy conservation &lt;br&gt; ( F). EARTHING:- Supply of all material and providing duplicate earthing by 25 x 3mm copper strip on wall /column/floor/buried (Appx. 20 mtrs) in ground and giving double earthing to motor,starter,panel board etc. and connect with existing earthbus. As per IE standards &lt;br&gt; (G).CAPACITOR:- Supply,erection,testing and commissioning suitable rating of of heavy duty APP capacitor for the above motor to get unity&lt;br&gt;power factor . The capacitor shall confirm to IS 2834 &lt;br&gt; (H).VALVE:- Supply of suitable size best quality heavy duty ISI Marked CI double fanged sluice valve and Non return valve with suitable pressure rating.fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Pressure gauge on both suction and delivery side &lt;br&gt;&lt;br&gt; (I).SUCTION AND DELIVERY PIPE CONNECTIONS:- Supply and fitting of suitable size best quality MS pipe of thickness not less than 8 mm for a total length of 8 m (approx). suitable for the above pump set and suitable size foot valve and connecting the suction pipe of size 200mm MS and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with 150mm MS pipe of thickness not less than 8 mm for a total length of 8 m (approx) , vales and suitable specials to connect with the pumping main
280OD168051/2023-2024:Approval from Electrical Inspectorate including preparation of drawings, obtaining approval for the drawings, arranging inspection of the installations and obtaining safety certificate et; after completion of the works. The necessary statutory fees, if any, payable to the Electrical Inspectorate / KSEB will be paid by KWA. (Note : Scheme approval from the Electrical Inspectorate has to be obtained before supplying the equipments. Payment for the supply of materials will be released only on production of scheme approval) including Energization approval from inspectorate and approvals from KSEBL. - Actual rate = 10000.00/L.S For avoiding CPOH 16% = 0.84*10000=8400/L.S
281Construction of pipe line bridge
2822.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2832.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2842.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
2854.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
286OD182803/2023-2024:Dowel Bar-Supplying and providing MS dowel bars of size 20mm dia. of 1m long. (0.5m in rock and 0.5m in concrete) including drilling holes of 20mm dia. and filling the gap with cement grout (100kg/hole) etc.
2875.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
2885.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
2895.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
2905.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
2915.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
29213.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
29310.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
294100.52.S.1:Sub Data for providing Earth filled cement bags including cutting of the Earth, filling, conveying and placing in position.
295100.52.S.3:Sub Data for Supplying, conveying and covering using best quality polythene sheet on bund to protect bund from seasonal changes.
296100.52.S.5:Sub Data for Dismantling the sand / earth filled cement bag from the foundation site of bund, apron on both sides, counter wall and removing the sand/earth from the bag and disposing the damaged cement bags properly as per the direction of the department officers including all cost of labour charges etc complete.
297100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
29813.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail