Tender For Repair / Maintenance Of Lt Distribution Network System, Various Size Cables, Busbar, Panel, Mccb And Allied Works At Offrs Enclave Area Under Age (I) Af Manauri, Chakeri-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Lt Distribution Network System, Various Size Cables, Busbar, Panel, Mccb And Allied Works At Offrs Enclave Area Under Age (I) Af Manauri. Submission Date for this Tender is 23-12-2023. Electrical Maintenance Tenders in Chakeri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

40717292
Corrigendum : Tender For Repair / Maintenance Of Lt Distribution Network System, Various Size Cables, Busbar, Panel, Mccb And Allied Works At Offrs Enclave Area Under Age (I) Af Manauri
Open Tender
Indian
Uttar Pradesh
Chakeri
23-12-2023

Tender Details

Tender For Repair / Maintenance Of Lt Distribution Network System, Various Size Cables, Busbar, Panel, Mccb And Allied Works At Offrs Enclave Area Under Age ( I ) Af Manauri

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-12-2023
2 18-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
INR 9 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINT OF LT DISTRIBUTION NETWORK SYSTEM, VARIOUS SIZE CABLES, BUSBAR, PANEL, MCCB AND ALLIED WORKS AT OFFRS ENCLAVE AREA UNDER AGE (I) AF MANAURI
Sl. No. Item Description
1Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified & directed.
2Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified & directed.
3Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
4Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioningas in trenches 8cm depth below cable and 15cm above cable andpunned to 10cm depthcomplete all as specified & directed. Note:- Punned thickness shall be considered for measurement purpose.
5M&L brick, sub class "B" bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified & directed.
6Labour only for reuse of serviceable bricks obtained from item No 1.00 complete all as specified & directed.
7M&L for cutting /boringto plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed. Note: Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site.
8S&F in replacement GI tubing light grade 80 mm dia of bore with all fitting laid in trenches across the road or fixed with pole/ surface of wall etc as site with required fixing accessories complete all as specified & directed. Make: Tata / Jindal / Swastik
9S&F in replacement galvainesd water tubing light grade 50 mm dia of borewith fix with pole/ surface of wall / laid in trench etc assiteusing 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc complete all as specified & directed. Make: Tata / Jindal / Swastik
10Supply, laid in trench / fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 35 Sqmm (earthed) complete all as specified & directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
11Dismantling of ACSR conductor complete all as specified & directed.
12Supply, laid in trench /fixedwith surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 150 Sqmm (earthed) complete all as specified & directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
13Supply, laid in trench /fixedwith surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 120 Sqmm (earthed) complete all as specified & directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
14Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area2.00 core x 10 Sqmm (earthed) complete all as specified and directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
15Labour for re-laying, connecting, jointing, thembling using in suitable size and cramping etc to serviceable XLPE insulate LT cablein all specification including brick (re-use) and sand (provided fresh) etc all as per existing complete with other site required works complete all as specified & directed. Note: Sand cushioning punned depth shall be measured and paid separately under respective items.
16Taking down old unserviceable garden light and S&F LED Bollard 10 watt in inverted pyramid tripod type LED Bollard with soft 360 light, IP 65 protection, resistant to corrosion with better optic for uniform distribution complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete with PCC work suitable size complete all as specified & directed. Make: Crompton Greaves Cat part No LBLSN-10CDL Philips / Havells / Surya / Bajaj
17Supply, install, testing and commissioning (in replacement) LT panel size 100 cm x 100 cm x 40 cmenclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door withfront and rear openable with locking arrangement including inner shutters formounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following complete all as specified and directed:-
18Notes for Serial Item No. 17.00: INCOMING:- (i) S&F On load change over switch capacity 250 Amp, 4 pole, 415 V, Size FR4, Type CO4-400, site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, Phase barriers, Handle with door interlock kit, with all fixing accessories suitable for horizontal as well as vertical mounting complete all as directed by Engr-in-Charge. (Make: Havells Cat Part No IHCNFO0250 / L&T / Indoasian / ABB / Siemens) (ii) MCCB 250 Amp ,415 Volt, 35 kA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Ics 75%, at 415 V (kA rms) Vac (kA rms), frame AN type, Confirms to IS/IEC60947-2. (Make - Havells Cat part No IHLLSEC40250 / ABB / Legrand / Siemens / L&T) (iii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder - 02 Nos (iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly provided with suitable size of copper insulated wire with universal coloured code of size 96x96mm- 01No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’sduly prewired with suitable size of copper insulated wire withuniversal colour code of size 96x96mm – 01 No (vi) Aluminium bus bar 400 Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc - 04 Nos OUT GOING:- (i) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 160 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 kA Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms)- 02 Nos (ii) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 100 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 KAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) - 01 Nos (iii)S&F street light timer distribution board HGS Smarty series digital Timer switch 230 volt three phase of 6 KW load capacity with contactor 32 Amp TPN with protection degree IP 54, extended wide band (150Vac-300 Vac) coil, FRLS internal wiring, inbuilt of short circuit protection - 01 No
19Taking down old unserviceable Busbar panel and supply and fixing Busbar chamber TPN current capacity 63 Amp 04 way horizontal type, total enclosed with porcelain Insulator and colour coated tinned copper bus bar with suitable size of legs including PCC work fixing on ground with GI angle frame suitable size of clamp, Nut, bolts, suitable size of thimbles for connectionetc. complete all as specified & directed. Make: Havells Cat part No IHBC006304 / L&T / Standard / ABB / Indoasian
20Supply, erecting and installation of steel tubular, swaged, pole of overall length9 meter having maximum tensile strength 42 Kgf/mm² of type 410 SP-31 conforming to IS-2713-1980 including a through hole of 14 mm dia shall be provided at height of 2.5 m from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings complete with cast iron base plate, having suitable dia of hole through the pole with nuts and bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 m length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 m length, 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 m length, 3.65 mm wall thickness of pole wall, approximate weight of pole 147 Kg, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/pasting three nos circular strips each of 100 mm wide with one blue and 02 Nos white colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including taking out old PCC pole from ground complete all as specified & directed. Note:- Necessary Excavation and earth work, PCC Work for foundation of pole assembly shall paid separetely.
21S&F in replacement bracket for street light fittings made out of 40 mm dia "medium grade" galvanized steel (GI) tubing of 1.5 m long, bent to required shape (having an angle 120 degree) including necessary FI clamp (02 Nos of size 40 x 5 mm) suitable size nuts, bolts and washers and fixing to the pole complete all as specified & directed.
22S&F in replacement energy saving LED street light fitting 60 watt aerodynamically designed for all weather conditions with excellent thermal management with Pressure die cast housing Aluminium body and toughened glass visor fitted in frame, separately driver compartment provided, secondary optical lens for superior light distribution efficiency >110/125/135 LPW, CCT 5700K, IP66, input voltage from 120-270 V power factor above 0.95 complete fitting including making electric connection using three core copper flexible cable from controll box to street light fitting complete with all accessories complete all as specified and directed. Note: Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make: Crompton/C&S / Havells / Philips / Bajaj
23S&F in replacement LT cable junction box dust and water proof made out of PVC non metallic sheet FRP type, factory made out of PVC non metalic sheet FRP type, factory made, size of box 250mm x 200 mm x 100 mm deep with swivelling cover and locking clamp, MS clamps and nuts, bolts, for fixing the box on steel tubular pole, consisting of aluminium bus bar strip 150mm x 30 mm x 3 mm - 04 nos mounted on pole complete all as specified & directed. Make: Sintex CAT part No GS-JB2520 / Henson / Legrand.
24M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate for foundation of poles, stay assembly, struts, etc. including all necessary formwork complete all as specified & directed.
25M&L for cement concrete 1:3:6 type C-1 using 20mmgraded stone aggregatein foundation for pedstal coppings,bedding of pips including necessaaryform work, fair finishing to exposed surfaceusing extra cement complete all as specified & directed.
26M&L for Earthing complete (in replacement) with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to galvanized earth lead using GI earth strip in size 32x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified & directed.
27Notes for Serial Item No. 25.00 :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
28S&F Air circuit Breaker Microprocessor release type capacity 630 Amp, 415 Volt, 50 Hz, 4 pole, short circuit breaking capacity 50 kA, Ics 100%, Electrical operated, Drawout type, alongwith all accessories for connection of incoming and outgoing supply connection and fixing accessories for fixing ACB in existing panel including taking down old unserviceable ACB complete all as specified & directed. Make: Old ACB shall be deposited to MES store yard by the contractor.
29S&F Adjustable thermal and fixed magnetic setting based MCCB 4 Pole 400 Amps, Rated Ultimate Shortcircuit Breaking Capacity 36 KAIcu at 415 V, Rated service short circuit Breaking capacity Ics=100% Icu at 415V (KA rms) along with spreader terminals (extended copper terminals-04 Nos) including taking out existing unserviceable / burnt MCCB from site complete all as specified & directed.
30M&L for marking / stencil writing of pole numbers with black paint complete with in round circul of size of Letter and Number complete all as specified & directed.
31Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix "B" to Particular specifications as approved by AGE (I) AF manauri
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail