| 1 | SCHEDULE‘A’ PART-I ( Replacement of Barbed wire fence with Chain Link Fence around the perimeter) |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 3 | Earth work in surface excavation not exceeding 30 cm in depth butexceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 5 | M/L for earth wk excation in pot holes n.exc.0.50 cum and getting out and removal of earth upto 50 mtr and making good surface. |
| 6 | M/L for PCC 1:2:4 type B2 in fdn filling and mass conc |
| 7 | M/L for angle iron of size 80x80x8 mm incl cutting drilling making holes notching wire with bolting etc |
| 8 | M/L for Y angle at Top with angle iron of size 65x65x6 mm incl cutting, drilling making holes for bolting etc |
| 9 | M/L for MS flat iron 50x6 mm size for securing wire mesh incl necessary drilling & bolting etc |
| 10 | M/L for MS screw bolts (machine made) with hexagonal head at one end and screwed the other, screwed end to be fitted with one washer and one hexagonal nut (12 mm dia & 60 mm long) |
| 11 | M/L for 2 coat ofanti corrosive enamel paint over one coat of red oxide primer incl preparation of surface to angle iron post, Flat iron & Struts. |
| 12 | M/L for Chain Link Fabric Fencing mesh of size 50x50 mm made of GI wire 4 mm dia, PVC coated to outer dia 5 mm & fixing to any type of standard rail securing or tyingwith pin stapled etc. Height= 2.00 mtrs |
| 13 | Providing & fixing Concentrina coil of 600 mm dia 10 mtrs openable length per bundle at the Top of Y angle as per dwawing |
| 14 | M/L for RCC 1:1 1/2: 3with 20 mm garded stone agg for Tie Beam of size 250mm x 300 mm |
| 15 | Steel reinforcement TMT bar 16 mm dia 06 Nos & 8 mm dia stirrups 150 mm C/c spacing for Tie beam |
| 16 | Use & waste of form work for Tie beam |
| 17 | SCHEDULE‘A’ PART-II (Elevated Sentry Post) |
| 18 | Construction of Elevated Sentry Post with PPG sheet roofing, cement concret flooring all as per specification and drawing No. IGAR(N)/Engr/ 2016/23 sheet No.1/1 includinginternal & external painting as per drawing and direction of Engr in charge but excluding internal & external electrifications |
| 19 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 20 | S/F of CFL light fitting, 1x9 W bulk head luminaries, with lamp holders, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ. |
| 21 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 22 | Supplying and fixing piano type switch 5 Amp on the existing switch box/ cover including connections etc. as required. |
| 23 | S&F of flood light luminaire 250W HPSV lamp complete with ballast, ignitor etc as required. (Make Havells/Bajaj/Philips/ISI). |
| 24 | Supplying and fixingpiano type switch 15 Amp with switch box/ cover including connections etc. as required. |
| 25 | Supplying and fixing 2+4 way single door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc.as required. (But without MCB/RCCB/ Isolator) |
| 26 | Supplying and fixing 40 Amp double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 27 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 28 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 29 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. |
| 30 | S&F 1100 volts grade heavy duty cable PVC sheathed aluminium conductor 10 sqm twin core stranded conductor in service connection suspanded by insulating hangers not more than 1.10 mtr apart incl 4 mm suspension wire. |
| 31 | SCHEDULE‘A’ PART-III (Perimeter Security Lights) |
| 32 | Supply and fixing of street light steel tubular swaged poles9.00m long complete with CI base plate and finial including foundation and coping. |
| 33 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables 1100 volts grade with standard aluminium conductor of size 16 sqmm 2 core incl earth work with trenching, sand cushioning, brick soiling etc in all complete. |
| 34 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables 1100 volts grade with standard aluminium conductor of size 35 sqmm 3.5 core incl earth work with trenching, sand cushioning, brick soiling etc in all complete. |
| 35 | Supply and fixing of LED street light 100 W (Make-Havells/Phillips of equivalent) |
| 36 | Supply and fixing of street light pole terminal box, hinged water proof plastic polycarbonate ABS enclosure 130x180x100mm including clamping system in all complete. |
| 37 | Supply and fixing of street light pole mounting bracket suitable for 100 W LED light , GI pipe 32mm dia 2\" long pole support with two nos clamping system and 2\" long 120 degree direction for mounting of light incl holling, bending, alluminium painting and finishing in all respect |
| 38 | Supply and installation, testing and commissioning of out door type feeder piller cubical panel bd factory made with locking arrangement made of angleiron frame work of size 40 X 40 X 6 mm and MS sheet duly painted with two coats of red oxide primer, incl 200 A copper busbar and internal wiring with multi stand copper conductor cable comprising as follows incl PCC foundation base :(i) MCCB, 4 pole, 415V, 200 Amp (Incoming line) - 01 No.(ii) MCB DP 63 A- 04 Nos(iii)Change over switch, 125 A, 415V, 4 pole - 01 No(iv) Voltmeter0-500 Voltwith - 01 No.selector S/S(v) Amp meter 0-100 A with CT &- 02 Nos selector S/S(vii) Pilot lamps, 12 volt - 03 NoMake- of panel board – L &T /Assam electrical(CPRIapproved) |
| 39 | SCHEDULE‘A’ PART-IV (RRM Retaining Wall) |
| 40 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil. |
| 41 | Providing and laying in position cement concrete 1:4:8 using stone agg 40mm nominal size excluding the cost of centering and shuttering - All work up to plinth level. |
| 42 | M/L for random rubble masonry with hard stone in retaining wall, including leveling up with cement concrete 1:6:12 in CM 1:6. |
| 43 | M/L for PCC 1:2:4 type B1 as in coping. |
| 44 | M/L for raised pointing to random rubble masonry surfaces using CM 1:4. |
| 45 | M/L for loose filling agg of gauge 63mm to 45mm on back side of retaining wall. |
| 46 | M/L for PCC 1:3:6 for weep hole. |
| 47 | M/L for 110mm dia PVC pipe for weep hole. |
| 48 | SCHEDULE‘A’ PART-V ( HUME PIE 600 MM DIA) |
| 49 | M&L for PCC 1:3:6 type C2 for basement & sides of hume pipe |
| 50 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C.pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete . 600 mm dia |