| 1 | Supplying and stacking of good earth called a loam and has roughly 40% sand, 40% silt and 20% clay. at site including royalty and carriage complete all as specified and directed by Engr-in-charge. |
| 2 | Supplying and stacking at site dump sludge manure from approved sources including carriage at work.Screened though sieve of 1.5 designation 4.75 mm complete all as specified and directed by Engr-in-charge. |
| 3 | Digging holes (90cm dia and 90cm deep) in ordinary soil and refilling the same after plantation as in ser item no 4 withmanure or sludge in ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after deduction by 8%) flooding with water, dressing including removal of rubbish, Complete all as specified and directed by engr-in Charge |
| 4 | Supply of the plants at site including all transportation charges includingcomplete all as specified and directed by Engr-in-charge incl operation of plantation of following specification, Botanical Name (Common name) overall height, Stem size.Notes: (i) The cost incl Maintenance of all plants, shrubs, Hedges, grass etc a period of one year after completion of work of by employing skilled Gardner to ensure healing, up keeping/ watering of plants, pouring manure, carryout periodic filling and use pesticides, cutting grass and removing unwanted grass and plants at site are inclusive of the rate. Nothing extra shall be admissible on this account.(ii) Rates is also inclusive of replacement of damaged tree, hedge and grass. |
| 5 | SHADED TREES:- SARACA INDICA (ASHOKA) over height 3-5 feet stem size 6 - 8Cms. |
| 6 | SHADED TREES:- DELONIX REGIA (GULMOHAR) over all height 3-5 feet stem size 6 - 8Cms. |
| 7 | ORNAMENTAL TREES :- (TABULAR PALM TREES) over height 5 feet stem size 10 -15Cms. |
| 8 | ORNAMENTAL TREES :- (DWARF PALM TREES) over height 5 feet stem size 10 -15Cms. |
| 9 | FRUIT TREES :- PSIDIUM GUAJAVA (GUAVA) over all height 4- 5 feet stem size 6 - 8Cms. |
| 10 | FRUIT TREES :- MANIGIFERA INDICA (MANGO) over all height 4- 5 feet stem size 6 -8Cms. |
| 11 | FRUIT TREES :- (POMEGRANATE) over all height 4- 5 feet stem size 6 -8Cms. |
| 12 | Supply of the plants at site including all transportation charges including complete operation of plantation. (HEDGE TREES) Botanical Name (Common Name) Overall height, stem Size etc. incl Preparation of beds for hedging and shrubbery by excavating 60Cm deep and 30cm wide refilling with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of material declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 cm lift upto 1.5mcomplete all as specified and directed by Engr-in-charge. complete all as specified and directed by Engr-in-charge.(Cost of sludge, manure or extra earth to be paid for separately). Notes: (i) The cost of incl Maintenance of all shrubs, Hedges, grass etc a period of one year after completion of work of by employing skilled Gardner to ensure healing, up keeping/ watering of plants, pouring manure, carryout periodic filling and use pesticides, cutting grass and removing unwanted grass and plants at site complete all as specified and as directed.(ii) Rates is also inclusive of replacement of damaged tree, hedge and grass. |
| 13 | CLERODENDRUM INERME- Height 25 - 30Cms |
| 14 | DURENTA GOLDEN – Height 25 - 30Cms |
| 15 | Lawn (Grassing) Supply and plantation of grass selection No. 1 by dibbling root method. Note : Following activities/ works to be carried out at site for plantation of grass selection No. 1.(i) Ploughing of whole site in ordinary soil upto a depth of 30Cm and removing unwanted material such as stones, weeds, trees roots etc which are not suitable for healthy growth of grass complete all as specified and directed by Engr-in-charge.(ii) Dressing and levelling of soil to a required gradient and slope after loosening of soil.(iii) Mixing and spreading of good earth, manure and fertilizer as directed.(iv) Fine dressing the ground to required slope and gradient towards the manhole.(v) Grassing with specified grass including watering unit establishment of the lawn.(vi) Final levelling by spreading sand and good earth mixture, manuring as and when directed. |
| 16 | Supply and plantation of Plants beds/Flower beds (accomplish by planting a mix of annuals, Perennials and Shrubs) 30cm wide along the Path/Hardstand or as directed by engr-in-charge. Note : Following activities/ works to be carried out at site for plantation of grass selection No. 1.(i) Ploughing of whole site in ordinary soil upto a depth of 30Cm and removing unwanted material such as stones, weeds, trees roots etc which are not suitable for healthy growth of grass.(ii) Dressing and levelling of soil to a required gradient and slope after loosening of soil.(iii) Mixing and spreading of good earth, manure and fertilizer as directed.(iv) Fine dressing the ground to required slope and gradient towards the manhole/Drain.(vi) Final levelling by spreading sand and good earth mixture, manuring as and when directed.(i) The cost incl Maintenance of all plants, shrubs, etc a period of Six months after completion of work of by employing skilled Gardner to ensure healing, up keeping/ watering of plants, pouring manure, carryout periodic filling and use pesticides, cutting grass and removing unwanted grass and plants at site are inclusive of the rate. Nothing extra shall be admissible on this account. |
| 17 | M&L for Continuous brick edging of brunt clay brick of sub class B; with width equal to the length of the brick; laid dry on edge at the required angle complete all as specified and directed by Engr-in-charge. |
| 18 | Jointing of Supplying and laying of CPVC pipes having 50mmBoreSDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and as directed by Engr-in-Charge. |
| 19 | Jointing of Supplying and laying of CPVC pipes having 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and as directed by Engr-in-Charge. |
| 20 | Jointing of Supplying and laying of CPVC pipes having 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and as directed by Engr-in-Charge. |
| 21 | Supply and fixing of 25mm PTMTgate valve/Stop valve any colour high pressure (Having Minimum weight 95gms) screwed/fixed at both ends forfor 25mm iron pipe/CPVC Pipecomplete all as specified and directed by Engr-in-charge. |
| 22 | Supply and fixing of 20 mm PTMTgate valve/Stop valve any colour high pressure (Having Minimum weight 95gms) screwed/fixed at both ends forfor 25mm iron pipe/CPVC Pipecomplete all as specified and directed by Engr-in-charge. |
| 23 | Supply and fix of PTMT Sprinkler of pressure 3Kgf/cm2 quick/ early response type with stand, pendent type complete all as specified and directed by Engr-in-charge. |
| 24 | Supply only Rubber/PVC tube of 20mm dia bore having 1.8mm to 2mm wall thickness for Watering complete all as specified and directed by Engr-in-charge. |
| 25 | Supply and fixing centrifugal pump set, electric deiven230V-240V, Single Phaseof capacity 1.5 HP having minimum RPM 2900, Cast iron impeller ,coper winding motor, Working pressure 1.7 to 2kg/Cm2, having inlet and outlet pipe50mm with self priming upto 7.5 mtr Complete all as specified and directed consisting of following :-(a) DB Box with2 way MCB SPN 240V, out going cable with IP43 Protection. (b) All fittings for fixing inlet and out let pipe.Complete all as specified and directed by Engr-in-Charge. |
| 26 | Supply and fix drip pipe PVC type 15mm for drip irrigation with all necessary connection from tapping point complete all as specified and directed by Engr-in-charge. |
| 27 | Supply and fix GI 40mm Tubes, \"light grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors like Tee, Elbow, Bends, Flanges, Reducers, Gaskets, Nuts and Bolts welding or screwed joints etc complete all as specified and directed by Engr-in-charge. |
| 28 | Supply, laying, jointing and testing XLPE armoured heavy duty electric cable with aluminium conductor 1100volts grade of size 10 Sqmm 2 core complete all as specified and directed by Engr-in-charge. |
| 29 | Material and labour for proving sand as in sand cushioningto underground cable including punning down of sand in layers,complete all as specified and directed by Engr-in-charge. |
| 30 | Material and Labour for PCC Cable Cover of Size 200mmx177-180mm having minimum thickness 30mm for UG cable laid dry and flat abutting each other with width equal to length of cover and gap between adjacent Cover not exceeding 10mm complete all as specified and directed by Engr-in-charge.. |
| 31 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft or loose soilcomplete all as specified and directed by Engr-in-charge. |
| 32 | Excavating over areas, n exc 1.5m deep and gettingout complete all as specified and directed by Engr-in-charge. |
| 33 | Excavating over areas,exc.1.5m but n exc 3.00m deep and gettingout complete all as specified and directed by Engr-in-charge. |
| 34 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft or loose soilcomplete all as specified and directed by Engr-in-charge. |
| 35 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soft or loose soilcomplete all as specified and directed by Engr-in-charge. |
| 36 | M&L for Cement concrete in foundations,filling and mass concrete Type C2 1:3:6 (40mm graded aggregate)complete all as specified and directed by Engr-in-charge. |
| 37 | M & L for PCC 1:5:10 type E2 as in fdn filling and mass concrete complete all as specified and directed by Engr-in-charge. |
| 38 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6complete all as specified and directed by Engr-in-charge. |
| 39 | M & L for PCC 1:2:4 Type B1 (20mm graded) copings, kneelers, apex stones, bed plates, kerbs or chamfered angles and throating including use & waste of formworkcomplete all as specified and directed by Engr-in-charge. |
| 40 | S&F RCC pipe 200mm dia, class NP-2 including cutting, jointing with collarscomplete all as specified and directed by Engr-in-charge. |
| 41 | M & L for Extra for forming fair finished drain or channel exc 30 cmbut n.exc 55 CM inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi-tred/stopped ends etccomplete all as specified and directed by Engr-in-charge. |
| 42 | M&L for cement concrete bed to drain pipes including packing under and haunching againstthe sides of pipe after they are laid & tested for 200 mm bore of pipe withcement concrete 1:3:6 type C-2 using 40mm graded stone aggregatecomplete all as specified and directed by Engr-in-charge. |
| 43 | M & L for 15 mm thick cement plaster (1:4)on brick on concrete surface finished even and fair complete all as specified and directed by Engr-in-charge. |
| 44 | M & L For steel wire fabric, wire of dia 3 mm and size of mesh 25 mm fixed to steel member all as specified , wt exceeding 4 kg/Sqmcomplete all as specified and directed by Engr-in-charge. |
| 45 | M & L for Framed work of angles or Tee such as grills,gratings,frame work of water tanks ,similar work conforming to fe 290 Gde E-165 complete all as specified and directed by Engr-in-charge. |
| 46 | M&L for Applying two coats of synthetic enamel paint over one coat of red oxide including preparation of steel surface over 10 cm width or girth complete all as specified and directed by Engr-in-charge. |
| 47 | M & L for loose filling with stone aggregate gravel of size 40 to 80 mm complete all as specified and directed by Engr-in-charge. |
| 48 | Description same as above item No 17 but size of gravel 10 to 25 mmcomplete all as specified and directed by Engr-in-charge. |
| 49 | M&L for Spreading and levelling in layers of coarse sand of size (1.6 mm to 2.0 mm) complete all as specified and directed by Engr-in-charge. |
| 50 | M&L for Flush pointing in CM 1:4 to brick work in walls or to bricks on edge in floors, surface channels, roofs, etccomplete all as specified and directed by Engr-in-charge. |
| 51 | M&L for Hand packing (any thickness) of broken stone or boulder at back of walls over arches etc. and raising (or lowering) to the required levelcomplete all as specified and directed by Engr-in-charge. |
| 52 | Drilling of bore of size 300 mm dia upto 50 mtr depth by direct rotary mechanical system for injection of pvc pipes 150mm dia in any kind of soil strata includung hard stone/boulders complete all as specified and directed by Engr-in-charge. |
| 53 | Reaming of bore well from size 300mm to 525mm dia below the bottom of bit up to 50 mtr depth by direct rotary mechanical system in any kind of soil strata incl hard stone/Boulders complete all as specified and directed by Engr-in-charge. |
| 54 | Supply assembling and lowering uPVC pipe SCH-80 , wall thickness not less than 10 mm, havy grade of size 200 mm dia socketed including fiting, rivetting jointing and lowering in bore hole conforming to IS 12818 complete all as specified and directed by Engr-in-charge. |
| 55 | All as per serial item No 29 here-in-before but slotted pipe having slots of size 1.5 mm width complete covered with stainless steel wire mesh complete all as specified and directed by Engr-in-charge. |
| 56 | Supply and fixing Stainless steel bail plug assembly suitable for 200 mm dia bore PVC casing pipe complete all as specified and directed by Engr-in-charge. |
| 57 | Supply and fixing Stainless steel well cap assembly suitable for 200 mm dia bore PVC casing pipe complete all as specified and directed by Engr-in-charge. |
| 58 | M&L for MS cross of450mm length with 150 mm branches made out of MS pipe heavy grade, havinginternal treads assembly suitable for 200 mm dia bore PVC casing pipe complete all as specified and directed by Engr-in-charge. |
| 59 | Supply and fixing mild steel clamp, 1050 mm long made out of mild steel flat of size 100 mm wide, 15 mm thick suitable for casing pipe of 200 mm dia, in two halves with suitable bolts, nuts and washers , including two coats of black bituminons paint over complete all as specified and directed by Engr-in-charge. |
| 60 | Supply and fixing of collector pipe for recharge pit made out of slotted MS pipe medium grade of size 100 mm dia including collector pipe covered with Stainless Steel wire mesh complete all as specified and directed by Engr-in-charge. |
| 61 | M&L For loose filling with Aggregate (6mm to 12.5mm)free from organic material,dust and clay screened properly complete as in filling recharge well, all as specified and directed by Enge-in-Charge. |