| 1 | SITE GRADING |
| 2 | Grading and leveling of areas to proper slope upto 75mm depth |
| 3 | Cutting grass at any place and removing to locations shown within MFL premises |
| 4 | Trees and bushes including jungle clearance and disposing the debris at locations shown within MFL premises |
| 5 | Surface dressing above ground level upto 1m height including removing vegetation, soil, Inequalities etc., and disposal of rubbish inside the premises.All kinds of soil |
| 6 | EARTH WORK & EXCAVATION |
| 7 | Excavation in any kind of soil including back filling, disposal of excess or unwanted soil within MFL |
| 8 | Ordinary soil |
| 9 | Hard Consolidated formalities like roads |
| 10 | Backfilling |
| 11 | Backfilling and proper consolidation only with locally available material from MFL premises |
| 12 | Supply and backfill with river sand, including proper consolidation |
| 13 | Dewatering with contractors pump |
| 14 | HIRING OF AIR COMPRESSOR WITH OPERATOR |
| 15 | While in operation (with MFL Diesel) |
| 16 | While in operation (with Contractor’s Diesel) |
| 17 | While kept idle |
| 18 | Hiring of back hoe front loader (JCB) |
| 19 | SHUTTERING , REINFORCEMENT & CONCRETE WORK |
| 20 | SUPPLYING AND LAYING PLAIN CEMENT CONCRETE OF PROPORTION 1:4:8 AT ANY LEVEL, INCLUDING CURING. |
| 21 | Using 40 mm blue metal stone aggregate |
| 22 | Using 20 mm blue metal stone aggregate |
| 23 | Using 40 mm brick jelly stone aggregate |
| 24 | Supplying and laying reinforced cement concrete, excluding shuttering and reinforcement but including Curing and necessary scaffolding wherever required |
| 25 | Using 20mm blue metal aggregate of proportion 1:2:4 - Upto 1Cu.m |
| 26 | Using 20mm blue metal aggregate of proportion 1:2:4 - for one Cu.m and above |
| 27 | Using 6mm blue metal aggregate and of proportion 1 : 1½ :3 |
| 28 | Extra for using water proofing / quick setting compound |
| 29 | Providing shuttering and form work for all cast in situ concrete work of all shapes, including material and labour complete |
| 30 | Fabrication reusable steel mould for precast RCC work (Steel scrap material supplied by MFL) |
| 31 | Supply and lay only reinforcement TOR Steel for concrete work including Cutting, bending, grouting and tying grills in position |
| 32 | Providing and laying in position ready mixed or site batched design M10 mix cement concrete for Plain Cement Concrete (PCC) work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete with minimum cement content of 220 kg /cum |
| 33 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for Reinforced Cement Concrete (RCC) work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge |
| 34 | Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge |
| 35 | Supply and laying of precast RCC compound wall with slab size 300mm X 2100mm X 50mm, column 150mmX150mm for the height of above 6ft above NGL. Complete as per instruction of MFL engineer In- charge |
| 36 | DISMANTLING or DEMOLISHING WORK |
| 37 | Dismantling or demolishing plain concrete and disposing the debris within MFL |
| 38 | Dismantling or demolishing reinforced cement concrete and disposing the debris within MFL including cutting of reinforcement |
| 39 | Making foundation pocket holes etc. upto 6”x 6” cross section and upto 9” depth including grouting with concrete 1:2:4 |
| 40 | Demolishing or dismantling and disposingbrick work at |
| 41 | Below 10 Mtrs. |
| 42 | Above 10 Mtrs. |
| 43 | Chipping any surface |
| 44 | Chipping any surface of concrete or brick work upto a maximum depth not exceeding 75mm |
| 45 | BRICK WORK |
| 46 | Demolish machine foundation including Cutting out bolts, frames and re-concreting to shape with necessary anchor bolts and base plates |
| 47 | Foundations less than ½ Cu.m |
| 48 | Foundations more than ½ Cu.m and less than 1 Cu.m |
| 49 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 50 | Supplying and laying brick work half brick thick in cement mortar 1:4, including Curing and scaffolding at all levels |
| 51 | Honey combed wall |
| 52 | Brick on edge partition 2” to 3” thick |
| 53 | Brick wall 4½” |
| 54 | Supplying and laying brick work in cement mortar 1: 4, including Curing and scaffolding. |
| 55 | Honey combed wall |
| 56 | Brick on edge partition 2” to 3” thick |
| 57 | Supplying and laying boulder or brick pitching on embankment or plain area including surface dressing, Curing and pointing with 1:4 cement mortar |
| 58 | Using boulder stones |
| 59 | Using brick soiling |
| 60 | Using Cuddapah slabs |
| 61 | Supply and lay brick bat in lime sand mortar 1:2 for paving or weathering course (including lime) |
| 62 | PLASTERING |
| 63 | 15 mm thick cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 64 | 20 mm thick cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 65 | Pointing only in 1:3 Cement Mortar on all paving and facing works |
| 66 | Grouting or patch repairs to cracks, crevices or furrows using `Casal’ compound of Associated Cement Company in cement mortar 1:3 not exceeding a thickness of 25mm |
| 67 | PAINTING |
| 68 | Prepare any surface by scrapping, sanding, cleaning or other means and apply |
| 69 | White wash (Complete with Material & Labour) |
| 70 | Colour wash (Complete with Material & Labour) |
| 71 | Cement paint of any colour (Complete with Material & Labour) |
| 72 | Plastic Emulsion paint of any colour (Complete with Material & Labour) |
| 73 | Enamel Paint (Complete with Material & Labour) |
| 74 | Weather Shield Paint (Exterior)(Complete with Material & Labour) |
| 75 | Varnishing Wood work to fine finishComplete with material & Labour |
| 76 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including all material & Labour. |
| 77 | Polishing furniture to fine finish with two coats of French or wax polish including all material & Labour |
| 78 | Chair |
| 79 | Table |
| 80 | Side Boards |
| 81 | FLOORING & PAVEMENTS |
| 82 | Providing marble floor of any colour at any level |
| 83 | 20mm thick bedding cement mortar of 1:3 proportion and 20mm thick readymade tiles, including polishing complete |
| 84 | 40mm thick bedding cement mortar of 1:3 proportion and 20mm thick readymade tiles, including polishing complete |
| 85 | Machine polishing mosaic floors including acid cleaning, rough and fine stone polishing and wax polish to fine finish |
| 86 | Providing and fixing Ist quality vetrifiedfloor tilesconformingto IS: 15622 (thickness to be specified by the manufacturer), of approved make, inall colours, shades, any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sq.m, including pointing in white cement mixed with pigment of matching shade complete. (including surface preparation) |
| 87 | Providing and fixing Ist quality ceramic wall tiles and floor tilesconformingto IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades ,any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sq.m, including pointing in white cement mixed with pigment of matching shade complete. (including surface preparation) |
| 88 | Supply and lay granolithic flooring of total thickness 40mm using blue metal aggregate of proportion 1:2:4 for base, thickness of 30mm thick and 6mm blue metal aggregate chips of proportion 1:2:4 for top dressing upto 10mm thickness. |
| 89 | Supplying and laying of pavement blocks for walkway platform |
| 90 | Supplying and laying acid resistant tiles With contractors material |
| 91 | Extra for Acid proof tile lining work |
| 92 | Supply and fix 1½” thick polished stone slab for flooring tables and finishing to correct shape as directed |
| 93 | Black colour Cuddapah slabs |
| 94 | Green colour Rajasthan Stone |
| 95 | Italian marble slabs |
| 96 | White marble slabs |
| 97 | kota stone slab |
| 98 | Polished granite slabs |
| 99 | Blue |
| 100 | Red |
| 101 | Black |
| 102 | Supplying and spreading blue metal of 40mm size to a thick as instructed |
| 103 | Supply and fixing of 2mm thick vinyl flooring planks with wear coat of 0.1 mm, plane profile, antistatic, slip resistance, wear resistance and fire resistance with necessary materials like adhesive , labour etc., including skirting all completeas directed by Engineer-in-charge (including removing existing vinyl flooring) |
| 104 | DOORS & WINDOWS |
| 105 | Supplying and fixing at all levels the different class of doors and windows of frame size as under, including fittings and fixtures, and painting with preservative coating |
| 106 | First Class teak doors of any size made out of suitable size wood frame and 32mm thick flush shutters |
| 107 | Door frame |
| 108 | Shutter |
| 109 | First Class teak shutters of any size and 32mm thick fully paneled |
| 110 | First class teak shutter only of any size fully glazed with shatter proof glass not less than 3mm thick flush shutters.Glazed Shutter |
| 111 | First class teak shutter I class teak shutter only of any size fully fly proofed with gauzed panels (per Sq.m) |
| 112 | Steel door frameSteel door frame only out of M.S angles of any size (Kg) |
| 113 | Steel ShuttersSteel Shutters only of any size with MS angles including shatter proof glazing not less than 3mm thick (Kg) |
| 114 | Aluminium frame Aluminium frame only with any size channels (Kg) |
| 115 | Aluminium flush shutters Aluminium flush shutters with 16Ganodized extruded Aluminium. Channels and with sheet for both sides flush panels facing : thick upto 25mm |
| 116 | Supply and fabricate glazed anodized extruded aluminium paneled or louvered windows with all fittings and fixtures of 100x120mm channels and 36x35x6mm T sections or near size sections |
| 117 | Glazed panel |
| 118 | Louvered panel |
| 119 | Doors of any size made out of suitable size wood frame and 32mm thick flush shutters but with good quality wood other than teak. |
| 120 | Door frame |
| 121 | Shutter |
| 122 | Shutters of any size and 32mmthick fully paneled but with good quality wood other than teak. |
| 123 | Shutter |
| 124 | Shutter only of any size fully glazed with shutter proof glass not less than 3mm thick flush shutters but with good quality wood other than teak. |
| 125 | Glazed Shutter |
| 126 | shutter only of any size fully fly proofed with gauzed panels but with good quality wood other than teak |
| 127 | Wooden Partition 32 mm thick – Other than Teak |
| 128 | Wooden Partition 75 mm thick – Other than Teak |
| 129 | Wooden packing box |
| 130 | PVC Door Sintex make |
| 131 | Fixing sun control film – 50 Microns thick |
| 132 | Supplying & fixing at all levels different class of windows of frame and sizes as under, including fittings and fixtures, and painting with preservative coating –Ist Class teak wood windows of any size frame and 20mm thick paneled shutters |
| 133 | Frame only |
| 134 | Shutter only |
| 135 | I class teak wood window shutter only of any size fully glazed with sheet glass not less than 3mm thick |
| 136 | I class teak wood window shutter only of any size and fully wired gauzed shutter only |
| 137 | Steel window frame only out of any size MS angles |
| 138 | Steel shutter only out of any size MS angles |
| 139 | Anodized extruded aluminum framewith 25 x 25 x 3mm including 20x20x6mm or near size angles or T section for aluminum shutters |
| 140 | Powder coated aluminum frame in 40 x 20 x 3mm |
| 141 | 45 x 35 x 3mm shutter only |
| 142 | Partial minor repairs to frame or shutter or both with any of the doors or windows described under section 7&8 above, including the fitting and fixtures, if any |
| 143 | Providing and fixing 12 mm thick paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured) Paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick. Marine plywood conforming to IS: 710 |
| 144 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): |
| 145 | 12 mm thick |
| 146 | 18 mm thick |
| 147 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). |
| 148 | 18 mm thick |
| 149 | 25 mm thick |
| 150 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 151 | 1.5 mm thick |
| 152 | 1.0 mm thick |
| 153 | Supplying and fixing at all levels Approved anodized aluminium 6 lever MORTICE latch or lock with keys & anodized aluminium handles |
| 154 | Plain |
| 155 | Pivoted |
| 156 | Replacing door handle only |
| 157 | Hydraulic Door closers of approved quality(Matl+Labour) |
| 158 | Light Duty |
| 159 | Heavy Duty |
| 160 | Repairs & Refixing only(Matl+Labour) |
| 161 | Door Closers (Everite or Doorma with ISI Certified) |
| 162 | Spring replacement |
| 163 | Misc. Repairs (Excluding spring) |
| 164 | Mortice latch or locks |
| 165 | Supply and fixing of floor spring assy |
| 166 | Supplying and fixing at all levels(Mtrl+Labour) |
| 167 | MS Hinges - 4”Size |
| 168 | MS Hinges - 5”Size |
| 169 | MS Hinges - 6”Size |
| 170 | Aluminium Hinges |
| 171 | 4” Size |
| 172 | 5” Size |
| 173 | 6” Size |
| 174 | Aluminium tower bolts |
| 175 | 4” Size |
| 176 | 6” Size |
| 177 | 8” Size |
| 178 | 10” Size |
| 179 | 12” Size |
| 180 | Aluminium Aldrop |
| 181 | 8” Size |
| 182 | 10” Size |
| 183 | Godrej Cupboard lock |
| 184 | Dindugul lock |
| 185 | Aluminium Padlock |
| 186 | 3” Size |
| 187 | 4” Size |
| 188 | Nab handle |
| 189 | 4” Aluminium handle |
| 190 | Supplying and fixing all levels |
| 191 | FRP Louvers |
| 192 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion(if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 193 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent overbackerrodofrequiredsize and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00sqm upto 5.00 sqm) |
| 194 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete |
| 195 | Fixed to steel windows by welding |
| 196 | Fixed to openings /wooden frames with rawl plugs screws etc |
| 197 | Supply and fixing of blinds and making good with walls vertical blinds 100mm regular make touch or equivalent all complete as directed by Engineer-in-charge (including removing existing blinds) |
| 198 | Removal of existing doors, windows, false ceiling, etc. |
| 199 | GLAZING WORK |
| 200 | Glazing only including fixing hooks and putting with glass not less than 3mm thick(Matl+Labour) |
| 201 | Ordinary sheet glass |
| 202 | 6mm glass |
| 203 | 5mm glass |
| 204 | Wire reinforced glass |
| 205 | Safex plate glass |
| 206 | Shatter proof sandwich glass |
| 207 | Acrylic Sheet 4mm thick |
| 208 | Fly proof wire mesh |
| 209 | AC ROOF SHEET |
| 210 | Supply and fix the following class of roof coverings including ridge, valley, covers or corners (including scaffolding but excluding SS J Bolt)Hole to be drilled by Drilling Machine. |
| 211 | AC Corrugated sheets (Big size)- 6mm Thick with ISI Certified(IS 459) |
| 212 | Non Asbestos Cement Corrugated sheets (Big size)- 6mm Thick with ISI Certified(IS 14871) |
| 213 | AC plain sheets |
| 214 | Lotus PVC corrugated coloured sheets / mm thickness |
| 215 | Transparent corrugated white acrylic sheets / mm thickness |
| 216 | GI Corrugated sheets / mm thickness |
| 217 | Polycarbonate sheets 6mm thick |
| 218 | Existing AC Sheet removal |
| 219 | Renewal of 8 mm SS Bolt (labour only) |
| 220 | Renewal of AC sheet fixed with 8 mm SS Bolt (bolt will be supplied by MFL) |
| 221 | Supply of SS ‘J’ Bolt of Ø 8mm per inch length with SS washer |
| 222 | Capping J or L bolts projections of AC sheet roof or cladding with PVC sheet or 12mm dia filled with tar compound, and tie up with necessary binding wire in position complete |
| 223 | Spreading contractor’s own net for doing roof leak jobs |
| 224 | Cleaning AC or GI sheet or terraced roof area top including removing spoiled tar felt application, supplying and applying new tar felt replacement with necessary primer and tar plastic application on top. |
| 225 | Anycolour metallic corrugated sheet for roof (per mm thickness) |
| 226 | Supplying and laying approved bitumen tar felt water proof mat single layer with peanut gravel dash at top over terraced flat roofs with a minimum guarantee of one years |
| 227 | Supply and apply TAR compound / plastic over the sheet roofs to isolated spot leaks |
| 228 | Supply and apply approved quality flash strip or equivalent with necessary primer over any area or roof surface of cladding |
| 229 | MISCELLANEOUS WORK |
| 230 | Supply and fix two strand GI barbed wire to fencing posts including stringing and tensioning and tying with necessary annealed binding wire |
| 231 | Supply and fix three strand GI barbed wire to fencing posts including stringing and tensioning and tying with necessary annealed binding wire |
| 232 | Supply and fix chain link fencing to fencing posts |
| 233 | Chain link fence material plain |
| 234 | Chain link fence material with Nylon coated – 6mm thick |
| 235 | Applying Tarcompound/plastic to masonry joints or cracks after necessary Cutting of chase 50x50mm deep for leak proofing |
| 236 | Minor repairs to disturbed black macadam road surface by repairs to potholes, depression, pit falls, corrugations, etc., and making good to original shape including material and labour complete. |
| 237 | Supplying and laying bitumen mastic |
| 238 | Percentage increase in Bill of Quote for civil maintenance jobs at TTP (Kodungaiyur) and PAT (Chennai Port Trust), CMD’s Office, Residence at Teynampet. |
| 239 | Manpower Supply (Normal Rate for Civil Jobs) |
| 240 | Manpower Supply (OT Rate for Civil Work) |
| 241 | Percentage increase over the bill value for Emergency supply of Civil andPlumbing material. |
| 242 | FALSE CEILING & FALSE FLOORING |
| 243 | Dismantling existing false ceiling and refixingthe new ceiling boards as per existing with necessary repairs to re-securing suspenders all as per existing |
| 244 | Provide false ceiling with aluminium framework, mild steel suspenders and ceiling boardsusing |
| 245 | Perforated jolly board |
| 246 | Thermocole slabs (12mm thick) |
| 247 | Supply and fixing of false ceiling with plaster of paris (thickness of 10mm to 12mm) including Aluminium channel |
| 248 | Providing and fixing 15 mm thick, light weight,fully perforated square/butt edge integral densified,false ceiling tiles of size 595x595 mm. |
| 249 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 250 | Providing and fixing removable raised/false access flooring panel with FS800H Grade Flooring Panel (Size 600 mm x600 mm x32 mm) all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge (including removing of existing false floor panel) |
| 251 | Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular loadbearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. (c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/Sq.m and an impact load of 50kg . All specification must be printed on the side of the panel to ensure the quality of the product. |
| 252 | 300 mm Finished Floor Height (FFH) |
| 253 | 450 mm Finished Floor Height (FFH). |
| 254 | WATER SUPPLY & SANITARY SERVICES |
| 255 | Water Supply and Sanitary Service: Dismantling existing old dilapidated pipelines by disconnecting tanks, cisterns, basins, commodes etc. or laying only new pipeline from source to tanks, cisterns, basins, commodes, etc |
| 256 | 15mm inDiameter pipe. |
| 257 | 20mmin Diameter pipe. |
| 258 | 25mm in Diameter pipe. |
| 259 | 32mm in Diameter pipe. |
| 260 | 50mmin Diameter pipe. |
| 261 | 63mm inDiameter pipe. |
| 262 | 75mmin Diameter pipe. |
| 263 | 100mm inDiameter pipe. |
| 264 | Fixing only any kind or make of valveon supply lines or Dismantling only thereof: |
| 265 | Valve Size 12mm |
| 266 | Valve Size 25mm. |
| 267 | Valve Size 32mm. |
| 268 | Valve Size 40mm. |
| 269 | Valve Size 50mm to 100mm. |
| 270 | Fixing only Sanitary and other fittings or Dismantling & Plugging only internal fittings with water – source - system |
| 271 | Taps or bib cocks upto 25mm diameter |
| 272 | Sprinklers or shower roses |
| 273 | Indian water closet including flushing system |
| 274 | European water closet including flushing system |
| 275 | Wash basin and water cooler |
| 276 | Urinal bowls |
| 277 | Flushing cisterns all categories |
| 278 | Fixing only screen marble Cuddapah |
| 279 | Fixing of mirror (2’x1 ½’) |
| 280 | Fixing of sundries like soap containers, towel rail, toilet paper holder, coat stand etc., |
| 281 | Supply and fixing of PVC Rain water downtake pipe 4” dia.(including all fittings) |
| 282 | supply and fixing PVC Rain water downtake pipe 6” dia.(including all fittings) |
| 283 | FIRE HYDRANT |
| 284 | Repairs to leaky lines underground |
| 285 | Upto 50mm dia |
| 286 | Above 50mm and upto 100mm dia |
| 287 | Repairs to leaky lines Above ground level: |
| 288 | Upto 50mm dia |
| 289 | Above 50mm and upto 100mm dia |
| 290 | Repairs of Fire Hydrant |
| 291 | Repairs to Fire Hydrant stand pipe damaged or leaky including excavation and bailing out water for repairs |
| 292 | Repairs to Fire Hydrant line leaks underground including excavation, bailing out water and changing spool pieces or specials. |
| 293 | Repairs to Fire Hydrant line leaks above gound level and changing spool pieces or specials but excluding scaffolding. a. Upto 100 mm dia |
| 294 | Repairs to Fire Hydrant line leaks above gound level and changing spool pieces or specials but excluding scaffolding b. Above 100mm & upto 150mm dia |
| 295 | Changing minor parts to valves, monitors or blinds, spool pieces and other specials above ground level.A.Upto 100 mm dia |
| 296 | Changing minor parts to valves, monitors or blinds, spool pieces and other specials above ground level.b. Above 100mm dia |
| 297 | Changing minor parts to valves, monitors or blinds, spool pieces and other specials but below ground level. a. Upto 100 mm dia |
| 298 | Changing minor parts to valves, monitors or blinds, spool pieces and other specials but below ground level. b. Above 100mm dia |
| 299 | Changing or laying all afresh and aligning Fire Hydrant lines above ground level. a.Upto 100 mm dia |
| 300 | Changing or laying all afresh and aligning Fire Hydrant lines above ground level. b. Above 100mm & upto 150mm dia |
| 301 | Changing or laying all afresh and aligning Fire hydrant lines below ground level. a. Upto 100 mm dia |
| 302 | Changing or laying all afresh and aligning Fire hydrant lines below ground level.b. Above 100mm & upto 150mm dia |
| 303 | Pressure testing of fire hydrant lines with necessary isolation and restoration to normal after inspection by statutory or other authorities |
| 304 | Minor repairs or maintenance overhauling to valve seats, gland joints leak, eye washers, fountain safety showers, inoperative valves, sprayers, basins, splashes or outlets etc., |
| 305 | Cleaning, clearing musk and operating underground valve chambers, surface hydrants, hose reels etc., a. Big Size |
| 306 | Cleaning, clearing musk and operating underground valve chambers, surface hydrants, hose reels etc., b. Small Size |
| 307 | Repairs, renewals etc., of nozzles, hose clips, hose reel body, frame or drum or changing of hoses to reel or other parts etc |