}

Repair/Maintenance Services Of Summer Appliances,Ref & Air Conditioners Including Wiring Lighting Fixtures ,Ceiling/Exhaust Fans,Well Mounted/Pedestal Fans Including Attending Day To Day Complaints At Cgra Rameswaram And Cgdhq -4 Area, kochi-Kerala

Military Engineer Services-MES has published Repair/Maintenance Services Of Summer Appliances,Ref & Air Conditioners Including Wiring Lighting Fixtures ,Ceiling/Exhaust Fans,Well Mounted/Pedestal Fans Including Attending Day To Day Complaints At Cgra Rameswaram And Cgdhq -4 Area. Submission Date for this Tender is 14-12-2023. Electrical Maintenance Tenders in kochi Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40684583
Corrigendum : Repair/Maintenance Services Of Summer Appliances,Ref & Air Conditioners Including Wiring Lighting Fixtures ,Ceiling/Exhaust Fans,Well Mounted/Pedestal Fans Including Attending Day To Day Complaints At Cgra Rameswaram And Cgdhq -4 Area
Open Tender
Indian
Kerala
kochi
14-12-2023

Tender Details

Repair / Maintenance Services Of Summer Appliances, Ref & Air Conditioners Including Wiring Lighting Fixtures , Ceiling / Exhaust Fans, Well Mounted / Pedestal Fans Including Attending Day To Day Complaints At Cgra Rameswaram And Cgdhq -4 Area- 1 Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. 2 Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-. (a ) onelight/fan point controlled by one switch 5 Amps 3 (b) One 3pin socket outlet 5 Amps on Independent board 4 (c) One 3 pin socket outlet 5 Amps on same board 5 (d) One bell pointcontrolled by one bell push 6 All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FRLS) including 4 sq mmPVC copper conductor used as earth wirefor power point on independent board for One 3 pin socket outlet, 15 Amps. 7 Supply and fix Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed. 8 Supply and fix SwitchSocket Combination 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed. 9 Supply and Fix switch socket combination 2 in1 , 6 pin, 16 Amps, 230 volt flush type complete all as specified and as directed. 10 Supply and Fixsocket outlet 2 in 1 3 pin, 5 Amps, 230 volt AC with ISI marked flush type complete all as specified and as directed. 11 Supply and fix Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed. 12 Attending internal electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge.Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid.(b) The spares required for the rectification of fault shall be measured under items 10 to 36, 52 to 59.(c) Five(05) numbers of complaint shall be measured as one unit(Each Job) 13 Supply only Switch piano Flush, single pole, one way 5 amp complete all as specified and directed. 14 Supply only switch socket outlet, 5 Amps, 3 pin flush type complete all as specified and directed. 15 Supply only Modular socket outlet, 5 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed. 16 Supply only Bell, AC, 230 volts, single pole complete all as specified and as directed. 17 Supply only Bell push 5 Amps one way complete all as specified and directed. 18 Supply only Electronicfan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed. 19 Supply onlyCeiling rose in poly carbonate 3 phases flush type 6 Amps, 230 volts AC complete all as specified and directed. 20 Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fittingcomplete all as specified and directed. 21 Supply only of Modular switch, one way, 6Amps complete all as specified and directed. 22 Supply only Modular switch, one way, 16Amps complete all as specified and directed. 23 Supply only Modular switch, two way, 6 Amps complete all as specified and directed. 24 Supply only Modular socket outlet, 6 Amps, 2 and 3 pin combined complete all as specified and directed. 25 Supply only Modular socket outlet, 6 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed. 26 Supply only Modular fan regulator step type, 120 Watt complete all as specified and directed. 27 Supply only Modular Bell push, 6 Amps complete all as specified and directed. 28 Supply only Modular switch socket combination 16 A 6 pin 3 Module complete all as specified and directed. 29 Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed.Make: Cat No QHPCWC5002X5 of Havells or equivalent in L&T/Surya 30 Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed.Make: Cat No QHPCWC5004X0 of Havells or equivalent in L&T/Surya 31 Supply only LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make: Crompton Cat Part No. CCS-100-20-65-HL2-DP-NWH or equivalent in Philips/Bajaj/Havells. 32 Supply only in replacement of LED bulb 9 watts, 230 volt, provides upto 4 Hrs backup 2200 mAh Li-On Battery for Longer Product Life,Protection Shield : Overcharge, Deep Discharge & Short Circuit Protection 100 Lumens Per Watt Surge Protection Upto 4Kv Voltage Protection upto 440V complete all as specified and directed.Make: Crompton Cat part No. LED12WDFINVNB4DCDL or equivalent in Philips/Bajaj/Havells. 33 Supply only LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Make: Crompton Cat part No. TCR-145-36-65-SL-NWH or equivalent in Philips/Bajaj/Havells. 34 Supply only LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Crompton Cat part No. LDLSRNX10-CDL/NW/WW or equivalent in Philips/Bajaj/Havells. 35 Supply and fixing in repair/replacement energy efficient LED building security light fitting 35W on existing brackets including connection with twin core flexible pvc 0.5 sqmm cable complete all as specified and as directed.Make: Havells Cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Philips/Bajaj/Surya. 36 Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20 Amps complete all as specified and directed. 37 Supply only MCB SP 6-32 amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed. 38 Supply only MCB SPN 63 amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 39 Supply only TPN 63 AMP, 415V 10KA C curve miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning all as specified and directed. 40 Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed. 41 Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed. 42 Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 12 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed. 43 Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way, Double door, IP-30 protection (4 + 12 module) TPN MCB, 415 V as incomer, SP/DP/TP/TPN as outgoingcomplete all as specified and directed . 44 Material and labour for Sub main wiring using two single corePVC insulated cable(FRLS) 4 sqmm copper conductor multi stranded and 4 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note- 3 run of 4 sqmm PVC copper wire and One run of PVC casing capingshall be measured and paid as oneunit. 45 Material and labour for Sub main wiring using two single corePVC insulated cable (FRLS) 6 sqmm copper conductor multi stranded and 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit. 46 Material and labour for Sub main wiring using four single corePVC insulated cable(FRLS) 6 sqmm copper conductor multi stranded and two runs of 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including PVC conduit pipe ISI marked of size 25 sq mm including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-6 run of 6 sqmm PVC copper wire and One run of PVC conduit shall be measured and paid as oneunit. 47 Taking down ceiling fan of any type and size, cable ends, dimantling blades and removing fan and balde to store yard and Hanging/fixing only repaired/reconditioned Fan of any type and size and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed. 48 Collection of unserviceable ceiling fan 1200mm/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan state & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed.Note : Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps shall be measured & paid separatetly. 49 All as per item No 45 here-in-before but exhaust fan 300 mm sweep 50 All as per item No 45 here-in-before but exhaust fan 450 mm sweep 51 All as per item No 45 here-in-before butWall fan 450 mm sweep 52 All as per item No 45 here-in-before butpedestal fan 400 mm sweep 53 Material and labour for Scraping down old paint of ceiling fan of any size sweep complete body & blade including down rod filling the cavitieswith filler and making smooth surfaceby applying two coats of synthetic enamel paint over a coat of primer after prepation with sand paperby means spray gun/brush withall as specified and as directed. 54 M&L forlathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed. 55 Supply only only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL 56 Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample 57 Supply only Gun metal bush for ceiling fan complete all as specified and directed. 58 Supply only Shackle type rubber reel,U clamps, bolts,split pin & washer complete all as specified and directed. 59 Supply only Canopy top/bottom suitable for 20 mm dia rod complete all as specified and directed. 60 Supply only Down rod 300 mm long of size 20 mm dia ISI marked complete all as specified and directed. 61 Supply only Fan blades suitable for 1200 mm sweep fan make & type as directed by Engr-in-Charge. 62 Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make as directed by Engr-in-Charge. 63 Supply and fixing Exhaust fan blade of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge. 64 All as per item No 61 here-in-before butfor 450 mmsweep 65 Supply and fixing Wall mounting fan blade 450 mm sweep and make suitable for fixing and as per sampleof existingfancomplete all as specified and directed . 66 Supply and fixing pedestal fan blade 400 mm sweep and make suitable for fixing and as per sampleof existingfancomplete all as specified and directed . 67 Supply and fixing Exhaust fan clamps including frame and louvers with ruber bush, etc suitbale for 300 mm sweep complete as per sample as directed by Engr-in-Charge. 68 All as per item No 65 here-in-before but for 450 mmsweep. 69 Supply and fixing Oscillating mechanism suitable for wall mounting fan any make and typeall as directed by Engineer-in-charge. 70 Supply and fixing in replacement of Exhaust fan Motor of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge. 71 All as per item No 68 here-in-before butfor Exhaust fan 450 mm sweep 72 All as per item No 68 here-in-before but for wall fan 450 mm sweep 73 All as per item No 68 here-in-before but for pedestal fan 400 mm sweep 74 Taking down geyser carefully of any make and capacity 25/50ltrs, dismantlingthe geyser for inspection, cleaning of tank, repalcement of defectivepart such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white enameled, spray paint of approved quality after cleaning of all dust rust etc and writingof MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified.Note :Supply only Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etc shall be measured & paid for seperately in respective items here in after. 75 Supply and fixing heating element any type (i.e; Cup,thread or triangular) 1.5 KW,220/230 volts ISI marked. 76 Supply and fixing Thermostat ISI marked complete all as specified and directed by Engr-in-Charge. 77 Supply and fixingHead Assy Brass 8 to 9 holes suitable for 25 ltrs capacity all as directed by Engineer-in-charge. 78 Supply and fixing Safety plug brass ISI marked suitable for 25/50 ltrs geyers 79 Supply and fixingHot and cold water connection made of brass pipe,chrumium plated upto 18 length complete with rubber washer & brass nuts, ISI marked all as directed by Engineer-in-charge. 80 Supply and fixing geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and directed by Engr-in-Charge. 81 Supply and fixing bottom cover plate in two halves with self toppiry suitable and as per sample complete all as specified & directed by Engr-in-Charge. Make :Bajaj, Peeco, Recold/DITZ 82 Supply and fixing phase indicator red colour circular/rectangular shape as suitable and as per sample complete all as specified anddirected by Engr-in-Charge. 83 Supply and fixing non return brass valve of 15mm bore, ISI marked as specified and directed by Engr-in-Charge. 84 Supply and fixing pressure release brass valve of 15mm bore ISI marked all as specified and directed by Engr-in-Charge. 85 Supply and fixing PVC connection wire woven with nickel plated brass adopter, both side threaded 45cm long the to suitable size of geysers complete all as specified and directed by Engr-in-Charge 86 Supply and fixing Plug top 3 Pin 16 Amps 230 volts all asspecified and directed by Engr-in-Charge. 87 M&L for servicing incl cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil forsplittype AC ofanymake/ capacity aftertaking down the whole unit and refixingat the existing locationor any other new location after servicing allas specified and directed by Engr- in- Charge .(Note: S&F spare parts will be measured and paid separately under relevant item.) 88 Taking down of Split type Air Conditioner of any capacity 1.5/2 TR from existing location incl removal of outdoor unit by opening all electrical connection and suction & discharge line connection carefully & removing materials to store for keeping in safe custody for reuse at site. Filling the opening of old location with cement mortor, applying white wash on wall with matching with existing colour of the site. Refixing, installation of Split type Air Conditioner to new location as directed by Engineer-in-charge, of any capacity 1.5/2 TR by filling of refrigerent, fixing of new bracket for installation of outdoor unit, fixing of suction and discharge copper tubes with replacement of insulation of suction & discharge line and making holes for passing of suction & discharge line on brick wall incl well finish with cement mortor, applying white wash, colour wash, distemper etc on wall to match with existing colour of the adjacent surface at new location, etc. complete all as specified and directed. 89 M&L for Shifting of water cooler electric driven single phase having any make and capacity from MES yard/existing location by taking it after disconnectionof electric and water line and refixing the same in any other new locationincl water and electric reconnection complete all as specified and as directed. 90 Supply and fix in replacement of the swing blade assembly comprises of swing blades and connecting rods used for driving the swing blades to swing synchronously for Split type air conditioner of capacity 2 TR complete all as specified and directed 91 Supply and fix in replacement of the swing blade assembly comprises of swing blades and connecting rods used for driving the swing blades to swing synchronously for Split type air conditioner of capacity 1.5 TR complete all as specified and directed 92 Supply and fix in replacement ofAC blower fan motor for ACsuitable for 1.5/2 TR split type AC suitable operate on 230 Volt AC supply at 50 HZ. 93 Supply and fix in replacement of AC indoor cooling condenser for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed. Make: LG/VOLTAS/ AIRCON/ VIDEOCON/ SIDWAL or equivalent as approved by GE 94 Supply and Fix in repair Air filters set of two of1.5/2.0 Ton split type AC complete all as specified and as directed.(Make:FIL/ UTILITY/ SPENCER/ VOLTAS/ AIRCON/ VIDEOCON/ SIDWAL). 95 Supply and fix in replacement of indoor AC unit back plate for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed 96 Supply and fix in replacement of indoor AC blower fan bush for Split typecapacity 1.5/2 TR complete all as specified and directed. 97 Supply and fix in replacement of indoor AC swing blades motor for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed 98 Supply and fix in replacement of Printed Circuit Board suitable for 2TR CapacitySplit Unit Air Conditioners including remote, etc. Make LG/equivalent as approved by GE 99 Supply and fix in replacement of Printed Circuit Board suitable for 1.5TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed. Make LG/equivalent as approved by GE. 100 M&L for Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. 101 Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. Make : LG/ Voltas/ Samsung complete all as specified and directed. 102 M&L for Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs as speciifed by Engr-in-charge.Make :LG/ Voltas/ Samsung complete all as specified and directed. 103 Supply and fix in replacement ofCapacitor 45 MFD complete all as specified and as directed.Make : Cat Part No QHLIDC545006 in Havells or equivalent in L&T/Surya 104 supply and fix in replacement of relay contactor 6 pin 220-240V AC completed all as specified and directed 105 Supply and fix in replacement of Thermostat switch for water cooler/Window AC complete all as specified and as directed. 106 Supply and fix in replacement of Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and as directed. 107 Supply and fix of insulationNytrile foam insulation suitable for 3/4 inch copper tube as per site requirement of approved makeall as specified and directed . 108 Supply and fix of insulationNytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved makeall as specified and directed . 109 Supply and fix in replacement of Copper tube3/4 inch size as per site requirement of approved makeall as specified and as directed. 110 Supply and fix in replacement of Copper tube 1/4 inch size of approved makeall as specifiedand directed . 111 Supply and fix in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5TRCapacity Split type Air Conditioners all as specified and as directed. Make : LG/ Voltas/Goderj 112 Supply and fix in replacement ofCondensing (Out door) unit complete including compressor, etc. Suitable for 2TRCapcity Air conditioners all as specified and as directed. Make : LG/Voltas/Goderj/Total line/Techmesh 113 Supply and fix in replacement of repair Bracket stand suitable for 2TR/1.5TR Capacity Split type AC including Fastners, etc. all as specified and as directed. 114 Supply and chargingR-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling appliances(charging cost incl in this item) all as specified and as directed. 115 Supply and chargingR-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces incl. (charging cost incl in this item) all as specified and as directed. 116 Schedule of Credit (Minus) Rs.22328.00NOTE: Bidder shall insert credit amount of Rs. 22328.00 as ratein Green field under Col-13.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR/MAINTENANCE SERVICES OF SUMMER APPLIANCES,REF & AIR CONDITIONERS INCLUDING WIRING LIGHTING FIXTURES ,CEILING/EXHAUST FANS,WELL MOUNTED/PEDESTAL FANS INCLUDING ATTENDING DAY TO DAY COMPLAINTS AT CGRA RAMESWARAM AND CGDHQ -4 AREA UNDER GE(I)(CG) KOCHI 8895/E8
Sl. No. Item Description
1Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
2Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-. (a ) onelight/fan point controlled by one switch 5 Amps
3(b) One 3pin socket outlet 5 Amps on Independent board
4(c) One 3 pin socket outlet 5 Amps on same board
5(d) One bell pointcontrolled by one bell push
6All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FRLS) including 4 sq mmPVC copper conductor used as earth wirefor power point on independent board for One 3 pin socket outlet, 15 Amps.
7Supply and fix Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
8Supply and fix SwitchSocket Combination 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
9Supply and Fix switch socket combination 2 in1 , 6 pin, 16 Amps, 230 volt flush type complete all as specified and as directed.
10Supply and Fixsocket outlet 2 in 1 3 pin, 5 Amps, 230 volt AC with ISI marked flush type complete all as specified and as directed.
11Supply and fix Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
12Attending internal electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge. Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid. (b) The spares required for the rectification of fault shall be measured under items 10 to 36, 52 to 59. (c) Five(05) numbers of complaint shall be measured as one unit(Each Job)
13Supply only Switch piano Flush, single pole, one way 5 amp complete all as specified and directed.
14Supply only switch socket outlet, 5 Amps, 3 pin flush type complete all as specified and directed.
15Supply only Modular socket outlet, 5 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed.
16Supply only Bell, AC, 230 volts, single pole complete all as specified and as directed.
17Supply only Bell push 5 Amps one way complete all as specified and directed.
18Supply only Electronicfan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed.
19Supply onlyCeiling rose in poly carbonate 3 phases flush type 6 Amps, 230 volts AC complete all as specified and directed.
20Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fittingcomplete all as specified and directed.
21Supply only of Modular switch, one way, 6Amps complete all as specified and directed.
22Supply only Modular switch, one way, 16Amps complete all as specified and directed.
23Supply only Modular switch, two way, 6 Amps complete all as specified and directed.
24Supply only Modular socket outlet, 6 Amps, 2 and 3 pin combined complete all as specified and directed.
25Supply only Modular socket outlet, 6 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed.
26Supply only Modular fan regulator step type, 120 Watt complete all as specified and directed.
27Supply only Modular Bell push, 6 Amps complete all as specified and directed.
28Supply only Modular switch socket combination 16 A 6 pin 3 Module complete all as specified and directed.
29Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed. Make: Cat No QHPCWC5002X5 of Havells or equivalent in L&T/Surya
30Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed. Make: Cat No QHPCWC5004X0 of Havells or equivalent in L&T/Surya
31Supply only LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: Crompton Cat Part No. CCS-100-20-65-HL2-DP-NWH or equivalent in Philips/Bajaj/Havells.
32Supply only in replacement of LED bulb 9 watts, 230 volt, provides upto 4 Hrs backup 2200 mAh Li-On Battery for Longer Product Life,Protection Shield : Overcharge, Deep Discharge & Short Circuit Protection 100 Lumens Per Watt Surge Protection Upto 4Kv Voltage Protection upto 440V complete all as specified and directed. Make: Crompton Cat part No. LED12WDFINVNB4DCDL or equivalent in Philips/Bajaj/Havells.
33Supply only LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make: Crompton Cat part No. TCR-145-36-65-SL-NWH or equivalent in Philips/Bajaj/Havells.
34Supply only LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Crompton Cat part No. LDLSRNX10-CDL/NW/WW or equivalent in Philips/Bajaj/Havells.
35Supply and fixing in repair/replacement energy efficient LED building security light fitting 35W on existing brackets including connection with twin core flexible pvc 0.5 sqmm cable complete all as specified and as directed. Make: Havells Cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Philips/Bajaj/Surya.
36Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20 Amps complete all as specified and directed.
37Supply only MCB SP 6-32 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.
38Supply only MCB SPN 63 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
39Supply only TPN 63 AMP, 415V 10KA "C" curve miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning all as specified and directed.
40Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed.
41Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed.
42Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 12 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed.
43Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way, Double door, IP-30 protection (4 + 12 module) TPN MCB, 415 V as incomer, SP/DP/TP/TPN as outgoingcomplete all as specified and directed .
44Material and labour for Sub main wiring using two single corePVC insulated cable(FRLS) 4 sqmm copper conductor multi stranded and 4 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note- 3 run of 4 sqmm PVC copper wire and One run of PVC casing capingshall be measured and paid as oneunit.
45Material and labour for Sub main wiring using two single corePVC insulated cable (FRLS) 6 sqmm copper conductor multi stranded and 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit.
46Material and labour for Sub main wiring using four single corePVC insulated cable(FRLS) 6 sqmm copper conductor multi stranded and two runs of 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including PVC conduit pipe ISI marked of size 25 sq mm including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-6 run of 6 sqmm PVC copper wire and One run of PVC conduit shall be measured and paid as oneunit.
47Taking down ceiling fan of any type and size, cable ends, dimantling blades and removing fan and balde to store yard and Hanging/fixing only repaired/reconditioned Fan of any type and size and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed.
48Collection of unserviceable ceiling fan 1200mm/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan state & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed. Note : Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps shall be measured & paid separatetly.
49All as per item No 45 here-in-before but exhaust fan 300 mm sweep
50All as per item No 45 here-in-before but exhaust fan 450 mm sweep
51All as per item No 45 here-in-before butWall fan 450 mm sweep
52All as per item No 45 here-in-before butpedestal fan 400 mm sweep
53Material and labour for Scraping down old paint of ceiling fan of any size sweep complete body & blade including down rod filling the cavitieswith filler and making smooth surfaceby applying two coats of synthetic enamel paint over a coat of primer after prepation with sand paperby means spray gun/brush withall as specified and as directed.
54M&L forlathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed.
55Supply only only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL
56Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample
57Supply only Gun metal bush for ceiling fan complete all as specified and directed.
58Supply only Shackle type rubber reel,"U" clamps, bolts,split pin & washer complete all as specified and directed.
59Supply only Canopy top/bottom suitable for 20 mm dia rod complete all as specified and directed.
60Supply only Down rod 300 mm long of size 20 mm dia ISI marked complete all as specified and directed.
61Supply only Fan blades suitable for 1200 mm sweep fan make & type as directed by Engr-in-Charge.
62Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make as directed by Engr-in-Charge.
63Supply and fixing Exhaust fan blade of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge.
64All as per item No 61 here-in-before butfor 450 mmsweep
65Supply and fixing Wall mounting fan blade 450 mm sweep and make suitable for fixing and as per sampleof existingfancomplete all as specified and directed .
66Supply and fixing pedestal fan blade 400 mm sweep and make suitable for fixing and as per sampleof existingfancomplete all as specified and directed .
67Supply and fixing Exhaust fan clamps including frame and louvers with ruber bush, etc suitbale for 300 mm sweep complete as per sample as directed by Engr-in-Charge.
68All as per item No 65 here-in-before but for 450 mmsweep.
69Supply and fixing Oscillating mechanism suitable for wall mounting fan any make and typeall as directed by Engineer-in-charge.
70Supply and fixing in replacement of Exhaust fan Motor of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge.
71All as per item No 68 here-in-before butfor Exhaust fan 450 mm sweep
72All as per item No 68 here-in-before but for wall fan 450 mm sweep
73All as per item No 68 here-in-before but for pedestal fan 400 mm sweep
74Taking down geyser carefully of any make and capacity 25/50ltrs, dismantlingthe geyser for inspection, cleaning of tank, repalcement of defectivepart such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white enameled, spray paint of approved quality after cleaning of all dust rust etc and writingof MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified. Note :Supply only Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etc shall be measured & paid for seperately in respective items here in after.
75Supply and fixing heating element any type (i.e; Cup,thread or triangular) 1.5 KW,220/230 volts ISI marked.
76Supply and fixing Thermostat ISI marked complete all as specified and directed by Engr-in-Charge.
77Supply and fixingHead Assy "Brass" 8 to 9 holes suitable for 25 ltrs capacity all as directed by Engineer-in-charge.
78Supply and fixing Safety plug "brass" ISI marked suitable for 25/50 ltrs geyers
79Supply and fixingHot and cold water connection made of brass pipe,chrumium plated upto 18" length complete with rubber washer & brass nuts, ISI marked all as directed by Engineer-in-charge.
80Supply and fixing geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and directed by Engr-in-Charge.
81Supply and fixing bottom cover plate in two halves with self toppiry suitable and as per sample complete all as specified & directed by Engr-in-Charge. Make :Bajaj, Peeco, Recold/DITZ
82Supply and fixing phase indicator red colour circular/rectangular shape as suitable and as per sample complete all as specified anddirected by Engr-in-Charge.
83Supply and fixing non return brass valve of 15mm bore, ISI marked as specified and directed by Engr-in-Charge.
84Supply and fixing pressure release brass valve of 15mm bore ISI marked all as specified and directed by Engr-in-Charge.
85Supply and fixing PVC connection wire woven with nickel plated brass adopter, both side threaded 45cm long the to suitable size of geysers complete all as specified and directed by Engr-in-Charge
86Supply and fixing Plug top 3 Pin 16 Amps 230 volts all asspecified and directed by Engr-in-Charge.
87M&L for servicing incl cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil forsplittype AC ofanymake/ capacity aftertaking down the whole unit and refixingat the existing locationor any other new location after servicing allas specified and directed by Engr- in- Charge .(Note: S&F spare parts will be measured and paid separately under relevant item.)
88Taking down of Split type Air Conditioner of any capacity 1.5/2 TR from existing location incl removal of outdoor unit by opening all electrical connection and suction & discharge line connection carefully & removing materials to store for keeping in safe custody for reuse at site. Filling the opening of old location with cement mortor, applying white wash on wall with matching with existing colour of the site. Refixing, installation of Split type Air Conditioner to new location as directed by Engineer-in-charge, of any capacity 1.5/2 TR by filling of refrigerent, fixing of new bracket for installation of outdoor unit, fixing of suction and discharge copper tubes with replacement of insulation of suction & discharge line and making holes for passing of suction & discharge line on brick wall incl well finish with cement mortor, applying white wash, colour wash, distemper etc on wall to match with existing colour of the adjacent surface at new location, etc. complete all as specified and directed.
89M&L for Shifting of water cooler electric driven single phase having any make and capacity from MES yard/existing location by taking it after disconnectionof electric and water line and refixing the same in any other new locationincl water and electric reconnection complete all as specified and as directed.
90Supply and fix in replacement of the swing blade assembly comprises of swing blades and connecting rods used for driving the swing blades to swing synchronously for Split type air conditioner of capacity 2 TR complete all as specified and directed
91Supply and fix in replacement of the swing blade assembly comprises of swing blades and connecting rods used for driving the swing blades to swing synchronously for Split type air conditioner of capacity 1.5 TR complete all as specified and directed
92Supply and fix in replacement ofAC blower fan motor for ACsuitable for 1.5/2 TR split type AC suitable operate on 230 Volt AC supply at 50 HZ.
93Supply and fix in replacement of AC indoor cooling condenser for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed. Make: LG/VOLTAS/ AIRCON/ VIDEOCON/ SIDWAL or equivalent as approved by GE
94Supply and Fix in repair Air filters set of two of1.5/2.0 Ton split type AC complete all as specified and as directed. (Make:FIL/ UTILITY/ SPENCER/ VOLTAS/ AIRCON/ VIDEOCON/ SIDWAL).
95Supply and fix in replacement of indoor AC unit back plate for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed
96Supply and fix in replacement of indoor AC blower fan bush for Split type capacity 1.5/2 TR complete all as specified and directed.
97Supply and fix in replacement of indoor AC swing blades motor for Split type air conditioner of capacity 1.5/2 TR complete all as specified and directed
98Supply and fix in replacement of Printed Circuit Board suitable for 2TR CapacitySplit Unit Air Conditioners including remote, etc. Make LG/equivalent as approved by GE
99Supply and fix in replacement of Printed Circuit Board suitable for 1.5TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed. Make LG/equivalent as approved by GE.
100M&L for Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer.
101Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. Make : LG/ Voltas/ Samsung complete all as specified and directed.
102M&L for Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs as speciifed by Engr-in-charge. Make :LG/ Voltas/ Samsung complete all as specified and directed.
103Supply and fix in replacement ofCapacitor 45 MFD complete all as specified and as directed. Make : Cat Part No QHLIDC545006 in Havells or equivalent in L&T/Surya
104supply and fix in replacement of relay contactor 6 pin 220-240V AC completed all as specified and directed
105Supply and fix in replacement of Thermostat switch for water cooler/Window AC complete all as specified and as directed.
106Supply and fix in replacement of Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and as directed.
107Supply and fix of insulationNytrile foam insulation suitable for 3/4 inch copper tube as per site requirement of approved makeall as specified and directed .
108Supply and fix of insulationNytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved makeall as specified and directed .
109Supply and fix in replacement of Copper tube3/4 inch size as per site requirement of approved makeall as specified and as directed.
110Supply and fix in replacement of Copper tube 1/4 inch size of approved makeall as specifiedand directed .
111Supply and fix in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5TRCapacity Split type Air Conditioners all as specified and as directed. Make : LG/ Voltas/Goderj
112Supply and fix in replacement ofCondensing (Out door) unit complete including compressor, etc. Suitable for 2TRCapcity Air conditioners all as specified and as directed. Make : LG/Voltas/Goderj/Total line/Techmesh
113Supply and fix in replacement of repair Bracket stand suitable for 2TR/1.5TR Capacity Split type AC including Fastners, etc. all as specified and as directed.
114Supply and chargingR-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling appliances(charging cost incl in this item) all as specified and as directed.
115Supply and chargingR-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces incl. (charging cost incl in this item) all as specified and as directed.
116Schedule of Credit (Minus) Rs.22328.00 NOTE: Bidder shall insert credit amount of Rs. 22328.00 as ratein Green field under Col-13.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail