Tender For Additional /Alternator To Bldg No T 02 Of Spear Offr Mess Under Age Br Ii At Rms, Shillong-Meghalaya

Military Engineer Services-MES has published Tender For Additional /Alternator To Bldg No T 02 Of Spear Offr Mess Under Age Br Ii At Rms. Submission Date for this Tender is 05-12-2023. Mobile Generator Tenders in Shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

40684582
Corrigendum : Tender For Additional /Alternator To Bldg No T 02 Of Spear Offr Mess Under Age Br Ii At Rms
Open Tender
Indian
Meghalaya
Shillong
05-12-2023

Tender Details

Tender For Additional / Alternator To Bldg No T 02 Of Spear Offr Mess Under Age Br Ii At Rms

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Nov-2023 AMENDMENT IN BOQ FOR ADDN ALTN TO BLDG NO T 02 OF SPEAR OFFR MESS UNDER AGE BR II AT RMS BOQ 05-12-2023
2 28-Nov-2023 AMENDMENT FOR ADDN ALTN TO BLDG NO T 02 OF SPEAR OFFR MESS UNDER AGE BR II AT RMS Other 05-12-2023
3 02-Dec-2023 AMENDMENT IN BOQ FOR ADDN ALTN TO BLDG NO T 02 OF SPEAR OFFR MESS UNDER AGE BR II AT RMS Other 05-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 86900.0 /-
Tender Value
INR 43.45 Lakhs /-

BOQ Items

Name of Work: ADDN/ ALTN TO BLDG NO T-02 OF SPEAR OFFR MESS UNDER AGE B/R-II AT RMS
Sl. No. Item Description
1Dismantling plain or corrugated steel sheeting, any gauge, thickness,including Nanital or similar pattern roof covering complete all as specified and as directed by Engr-in-Charge.
2Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
3Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed by Engr-in-Charge.
4Taking down Chowkhats or frames not exc. 1.5 sq. m each Ditto but with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engr-in-Charge.
5Taking down chowkats or frames with shutters with exc. 1.5 Sqm but n.exc. 4 Sqm each (without taking of shutters from the frames) complete all as specified and as directed by Engr-in-Charge.
6Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge.
7Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engr-in-Charge.
8Demolition of reinforced cement concrete of any description and inany position not otherwise specifically provided for etc complete all as specified and as directed by Engr-in-Charge.
9S&F pre-painted galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws etc complete all as specified and as directed by Engr-in-Charge.
10All as per Item No-09 (here-in-before) but plain sheet as in ridges, roof covering or in cladding etc complete
11S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer boardE-Board Classic to be fixed GI powder coatedgrid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mmduly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size etc complete all as specified and directed by Engr-in-Charge. Note;- GI Frame work shall be measured and paid separately.
12S&F size of grid 605 x 605 mm GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre etc complete all as specified and directed by Engr-in-Charge.
13M & L for PCC (1:2:4) type B-0 (using 12.5mm gradedstone aggregate) 25 mm thick as in sub base to receive tiles finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
14M&L for dark shade non-skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15 mm thick screed bed in CM 1:6 etc complete all as specified and directed by Engr-in-Charge.
15All as per Item No-14 (here-in-before) but on vertical surfaces such as in skirtinglaid over & including backing coat 10mm thick in CM 1:4.
16M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles laid over & including screed bed of 15mm thick in CM 1:4complete all as specified and directed by Engr-in-Charge.
17M&L for granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge.
18M&L for factory made flush shutters 35mm thick , solid core construction, with partical board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engineer-in-Charge.
19M&L for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in-Charge.
20All as per Item No 19 (here-in-before) but one coat of synthetic enamel paint on old surfaces
21S&F 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed by Engineer-in-Charge.
22S&F in repairs Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer-in-Charge.
23S&F 200 mm long aluminium anodised, barrel tower bolt of extruded sections complete all as specified and as directed by Engineer-in-Charge..
24S&F 150mm long aluminium alloy handled, fabricated type anodised complete all as specified and as directed by Engineer-in-Charge..
25S&F in repairs150mm long mild steel ordinary rat tail rod pattern springs including roller and roller complete complete all as specified and as directed by Engineer-in-Charge.
26S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engineer-in-Charge.
27M&L for brick work with sub class "B" burnt bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-in-Charge.
28All as per item No-27 (here-in-before) but in half brick thick wall built in CM 1:4
29M&L for Rendering 15mm thick cement plaster in CM 1:6 on brick work/concrete surfaces finished even and fair without using extra cement complete all as specified and directed.
30M&L for rendering 15 mm thick cement plaster in CM 1:4 on brick work/concrete surfaces finished even and fair with & including WPC @ 2% by weight of cement content and without using extra cement complete all as specified and directed.
31M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in coping, back filling, bed plates including necessary formwork complete all as specified and directed.
32Material and labour for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channel and like etccompleteall as specified and as directed.
33S&F Anodised aluminium powder coated (minimum thickness of powder coationg 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specifiedand directed by Engr-in-Charge.
34S&Ffor providing sliding type (3 Track +3 shutter) aluminium windows, section profiles of aluminium as per sketch No SK/2019/01 dated 21/01/19,aluminium alloy extruded sections conforming to HE 9-WP of BIS 733 and HP 9 -WP of BIS 1285 as amended, with minimum thickness of frames (outer bottom, Top & side ) 1.5mm and sliding sash (stiles & rails) of minimum thickness 1.2 mm. The windows shall be procured from a BIS license factory manufactoring windows to BIS-1948, The EPDM gaskets, rollers, recessed handles cum locks aluminium snap beading for receving glass/wiremesh with stainlss steel screws shall be provided with windows. The aluminium extruded section shall be of make Jindal/Hindalco/Alom extrusions etc all as listed and complete all as specified and directed by Engr-in-Charge.Note:- Glazing and Stainless steel wire mesh will be paid seperately.
35S&F Anodised aluminium door shutter, aluminium section weighing 0.55 kg/m inluding necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specifiedand directed by Engr-in-Charge.
36S&F Floor door stopper of aluminium alloy body and tounge, anodised, with hard drawn steel spring , fixed in floor , overall length of cover plate 140mm etc. complete all as specifiedand directed by Engr-in-Charge.
37Supply and fix sheet glass selected quality 4.0mm thick, any size, tinted of approved colour fixed with rubber beading complete all as specifed and directed.
38Supply and fixing3 mm thick frosted glass, ordinary quality and glazing with oil putty insquare n.exe 0.50 Sqm in each pane complete all as specified and as directed by the Engr-in-Charge.
39S&F for joist, channels, angles, or tee sections, fixed independently, without connecting plates, etc, (cut to ordinary lenght i.e. Within 20mm of the lenght indicated conforming Fe-410-W (Gde E-250 quality -A) complete all as specified and directed by Engr-in-charge..
40S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240
41S&F plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment, Fe 410-W complete all as specified and directed by Engr-in-charge..
42S&F bands, straps or stays , plain angle cleats or flat irons cleats or securing purlins to wooden trusses or rafters, knee pieces and similar small articales etc conformings to Fe-290 Grade E-165 complete all as specified and directed by Engr-in-charge..
43S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other end to be fitted with washer and one hexagonal or squre nut n exc 15cm long 12mm dia etc complete all as specifiedand directed by Engr-in-Charge.
44M&L for applying two coats synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description, over 10cm in width or girth, not otherwise described etc. complete all as specifiedand directed by Engr-in-Charge.
45All as per Item No 44 (here-in-before) but one coat of synthetic enamel paint on old surfaces
46M&L for applying two coats of OBD on new plastered surfaces of walls over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
47M&L for applying two coats of cement base paints on new plastered surfaces of walls over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
48M&L for applying one coat of OBD on old plastered surfaces of wallsincluding preparation of old plastered surfaces complete all as specified and as directed by Engr-in-Charge.
49M&L for applying one coat of cement base paint on old plastered surfaces of wallsincluding preparation of old plastered surfaces etc complete all as specified and directed by Engr-in-Charge.
50M&L for plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in roof kerb complete all as specified and directed by Engr-in-Charge.
51M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed by Engr-in-Charge.
52S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing etc complete all as specified and directed by Engr-in-Charge.
53S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing etc complete all as specified and directed by Engr-in-Charge.
54S&F 10mm thick Toughned glass as in hinged doors, partitions utomatic doors and similar work includingcutting to shape, drilling holes required etc complete all as specified and directed by Engr-in-Charge.
55S&F 100mm long and 10mm dia anchor fastners complete all as specified and as directed.
56M&L for fixing 2 mm thick anodised aluminium composite panel fixed in aluminium frame including necessary rubber beading, jointing cleats all as specified and directed
57S&F for 12mm thick toughness glass sensor operated door of size 8 feet x 12 feet of brand future plus automation including all fitting,fixturesrubber beading, jointing cleats etc all as specified and directed
58S&F 45mm thick green grass carpet (artificial) for lawn, or other rooms complete all as specified and as directed.
59Material and labour for (concelaed Type) point wiring including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessoriesfor mounting of fittings like switch, socket and fan regulator with modular inner plate and cover plate and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.
60Onelight/fan pointcontrolled by one, one way switch.
61One 3 pin socket outlet 5 Amps on the same board with other switches
62One 3 pin socket outlet 5 Amps on the independent board.
63All as per item No 59 (here-in-before) but with 2.5 Sqmm for 3 pin 15 Amps switch socket point on independent board along with one run of 2.5 Sqmm copper conductor green in colour as earth continuity conductor connected to earth dolly complete all as specified and as directed by Engr-in-Charge.
64M&L for Modular Switch 1 way 6A,1 module etc complete all as specified and directed by Engr-in-Charge.
65M&L for modular switch 1 way 16A, 1 module etc complete all as specified and directed by Engr-in-Charge.
66M&L for Modular Socket ,6A/2/3 pin combined 2 module etc complete all as specified and directed by Engr-in-Charge.
67M&L Modular Socket ,6A/16A-2/3 pin combined 2 module etc complete all as specified and directed by Engr-in-Charge.
68M&L for Metal flush box 1/2 module etc complete all as specified and directed by Engr-in-Charge.
69M&L for Metal flush box 3 module etc complete all as specified and directed by Engr-in-Charge.
70M&L for Metal flush box 6 module etc complete all as specified and directed by Engr-in-Charge.
71M&L for Metal flush box 12 module etc complete all as specified and directed by Engr-in-Charge.
72M&L for modular white cover plate with frame 2 module etc complete all as specified and directed by Engr-in-Charge.
73M&L for modular white cover plate with frame 3 module etc complete all as specified and directed by Engr-in-Charge.
74M&L for modular white cover plate with frame 6 module etc complete all as specified and directed by Engr-in-Charge.
75M&L for modular white cover plate with frame 12 module etc complete all as specified and directed by Engr-in-Charge.
76Supply and fixing LED luminaire 600 mm x 600 mm, 36/42 watt, LED Tunable Panel light fixtures with remote enable220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size etc complete all as specified and directed by Engr-in-Charge. Panel light Cat Part No : VENUSNEOTW2X2PLR42WLEDTWMOD, Driver Cat Part No : DRACO850RFCOMP2CH/DRACO1000RFCOMP2CH, Remote Cat Part No : RFREMOTETWCONTROL Make :Havells/Bajaj/CG/Philips
77M&L for LED strip 25W Non-integral flexible LED strip light high brightness for indoor applications. Strip can be cut at marked interval to suit desired lengthexisting space/ by cutting suitable space in false ceiling to mount light fitting with required handing/ fixing arrangement light fitting etc complete all as specified and directed by Engr-in-Charge.
78M&L for 25W LED strip driver IP20 etc complete all as specified and directed by Engr-in-Charge.
79Supply and fixing Wall mounted fan 400 mm sweep PP Blade and thermal overload protection for long lasting motor power consumation 58 Watt fan motor speed 1330 RPM Air dilivery 85 (CMM) with accessories complete all as specified and as directed by Engr-in-Charge.Note : Old Wall mounted fan deposit MES Store (AGE E/M) Make : Crompton/Bajaj/Havells
80M&L Distribution board double door type (for incoming MCCB 100 Amps 4 Pole & out going MCBs) DPX 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing only incoming MCCB and MCBs of various rating capacityDB of any capacityetc complete all as specified and directed by Engr-in-Charge.
81M&L for MCCB 4P, 415 Volts, adjustable type, 100 Amps with breaking capacity 16 KA, suitable for fixing in MCB DB including taking down old unsv MCCB etc complete all as specified and directed by Engr-in-Charge.
82M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity etc complete all as specified and directed by Engr-in-Charge. Note :MCB SPN/SP will be measured and paid separately.
83Supply and fixing MCB SPN 32 Amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning etc complete all as specified and directed by Engr-in-Charge.grand Cat No 408636 or equivalent in ABB/Siemens.
84Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning etc complete all as specified and directed by Engr-in-Charge.rand Cat No 408636 or equivalent in ABB/Siemens.
85M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 4 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
86Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil etc complete all as specified and directed by Engr-in-Charge.
87Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick etc complete all as specified and directed by Engr-in-Charge.
88Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and directed by Engr-in-Charge.
89M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
90M&L for laying brick sub class "B" old size burnt bricks for cable protection of size 230mmx115mmx75mm etc complete all as specified and directed by Engr-in-Charge.
91Supply & laying tubes "light grade" galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking out unsv GI tubing etc complete all as specified and directed by Engr-in-Charge.
92Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified orindicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1, RCC (1:1.5:3) type A1 precast cover (54cmx54cmx5cm) duly reinforced with including 8 mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embeded in precast cover slab, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.
93Supply and install verticalpack type Tower Air conditioner units indoor/outdoor complete with cordless remote control and with inbuilt air ioniser and Plasma filter for better indoor air quality with twin rotary compresser three phase units 415 volts 50 Hz of capacity 4.0 TR With eco friendly refrigerent etc complete all as specified and as directedby Engineer-in-Charge. Note :-(i) Cutting holes in walls/ Windowof any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate . (iii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer includedin above rate. (ii)copper piping/ drain piping/ insulation material/ tapping includedin above rate.
94M&L for Triple pole and earth encolsure with a three pin and earth plug with socket complete suitable for one triple pole MCB complete all as specified and as directed.
95S&F MCB triple pole and neutral 415 volts 32 amps, with rupturing capacity 10 KA, "B" curve type, with over load and short circuit protection etc complete all as specified and as directedby Engineer-in-Charge.
96S&Fand testing factory made sheet metal enclosurefor MCB DB TPN 4 way 415 volt with double door, IP - 43 protectionduly withfixed in wall/ concealed in wall complete and making good disturbed surfaces of wall, floor etc including electric wire connectionetc complete all as specified and as directedby Engineer-in-Charge.
97S&F MCB triple pole and neutral 415 volts 100amps, with rupturing capacity 10 KA, "B" curve type, with over load and short circuit protection etc complete all as specified and as directedby Engineer-in-Charge.
98S&F MCB triple pole and neutral 415 volts 40 to 63 amps, with rupturing capacity 10 KA, "B" curve type, with over load and short circuit protection etc complete all as specified and as directedby Engineer-in-Charge.
99M&L for sub main wiring with Four runs of6.00 Sq mm and one run of 6.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- Four runs of 6.00 Sq mm + one run of 6.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length.
Disclaimer :