Military Engineer Services-MES has published Tender For Repairs / Day To Day Maint Of Street Light / Solar Street / Pole / Cable Junction Boxes / Timer Switches / Search Lights At Harni Camp, Airfield And Darjipura At Af Stn Baroda. Submission Date for this Tender is 05-12-2023. Electrical Maintenance Tenders in baroda Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

40684569
Corrigendum : Tender For Repairs / Day To Day Maint Of Street Light / Solar Street / Pole / Cable Junction Boxes / Timer Switches / Search Lights At Harni Camp, Airfield And Darjipura At Af Stn Baroda
Open Tender
Indian
Gujarat
baroda
05-12-2023

Tender Details

Repairs / Day To Day Maint Of Street Light / Solar Street / Pole / Cable Junction Boxes / Timer Switches / Search Lights At Harni Camp, Airfield And Darjipura At Af Stn Baroda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 86400.0 /-
Tender Value
INR 43.20 Lakhs /-

BOQ Items

Name of Work : REPAIRS / DAY TO DAY MAINT OF STREET LIGHT / SOLAR STREET / POLE / CABLE JUNCTION BOXES / TIMER SWITCHES / SEARCH LIGHTS AT HARNI CAMP, AIRFIELD AND DARJIPURA AT AF STN BARODA
Sl. No. Item Description
1Comprehensive maintenance of street light fitting comprising of LED Street light fitting/HPSV/MH/ lamp fittings of any make any model fitted on the pole at any height with any type of fixing arrangement by replacing the drivers, surge protection device,ignitor, ballasts capacitor,control wiring copperwire and lugs all as directed by Engineer in charge. Comprehensive maintenanace also includes taking down street light fitting of any capacity from any height from the pole and increase or decrease the height of the fixing arrangement by removing the bent pipe and clamps and refixing itto the proper height and removing all the hanging wires, cables, PVC pipes,old rusted clamps, hanging aluminium wires, hanging grasses etc and tightening of all nuts, bolts, clamps and fixing of the street light complete all as specified and directed
2Description all as per items Ser No 1.00 here-in-before for 150/250 watt LED fittings of any make any model fitted on 11 SQN Hangar at height of 18 meter from ground and high mast light at runway complete all as specified and directed Notes for Item No 1 & 2:- (i)T&P including ladder for repair works shall be arranged by the contractor at his own cost. (ii) Spare parts required to be replaced under comprehensive maintenance shall be measured & paid separately under respective items of BOQ as supply only. However, quoted rate is deemed to included for fixing element of supply only items. (iii) Repair team for the street lights shall be available all the time to carry out maintanance works.
3Dismantling/taking out old defective unarmoured insulated LT service wire from wall/poles and supply and fix on wall/poles or passing through pipe, copper conductor cable PVC insulated, unsheathed, 1100 V grade ,2 x single core stranded copper conductor of size 1 sqmm complete all as specified and directed
4Taking out Old Unserviceableexisting street light"s bracket of any description and in any position and supplying and fixing brackets made out of40 mm dia light grade GI pipe 1.50 mtr long bent to shape and size fixed on location using existing/ new FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed Note : FI clamps shall be measured and paid saperataly.
5Supply and fix FI clamps made out of Flate iron strip size 32mmx 6mm suitable for fixing of street light fitting bracket onPCC/steel tubuler pole complete all as specifiedand directed
6Supply and fixing of Galvanised steel tubes, light grade 40mm dia for cable protection laid in pole coping , on wall/ under the road complete all as specified and directed Note : 1. Cost of Bends under the coping, breaking of existing PCC for laying of pipe is deemed to be included with unit rate of item. 2. Taking down of old GI Pipe of any size/ description shall deemed to be included in quoted rates.
7Disconnecting and taking out existing unserviceable PVC junctionboxes of any description and in any position on poles or fixed in the plinthof poles and Supply, installation, testing and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66 “weather proof”,for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with MCB SP 10 Amp and4 way TPN connector (DMC) low voltage capacity 100A each, glands including with ss rod clamps of, nuts and bolts complete all as specified and directed. Make Hansel Cat part No:KF 2525 G or equivalent make in /FIBOX(SOLID PC 2528 13G)
8Supply onlylamp suitable for metal halide luminous suitable for 400 Watts single and tubular type complete all as specified and directed Make: Havells Cat Part No. LHLQAGUL70400 or equivalent in Philips/ CG
9Supply only Electronic iginitor for suitable for 150/250W /400 HPSV/HPMV lamp complete all as specified and directed
10Supply onlyElectronic capacitor suitable for 400 Watt MH lamp complete all as specified and directed
11Supply only open construction heavy duty VPIT copper ballast for metal halide luminous for 400 watt MH of Havells, Cat No. LHGMCKENEBE1400 or equivalent in Philips/CG complete all as specified and directed
12Supply onlyLED surge protector multiple type 2 surge arrestors with thermal monitoring device and connector,dual visual fault indicator for the discharge path of the supply voltage and control the phase complete all as specified and directed
13Supply only LED drivers rated voltage 12/24 volt max out put power15W/ 75 W complete all as specified and directed Make :As per Existing Make of fitting
14Supply only LED drivers rated voltage 12/24 volt max out put power 100W -150W complete all as specified and directed Make As per existing make of fitting
15Comprehensive maintenance ofLED Solar Street light fittingof any make any model fitted on the pole at any height with any type of fixing arrangement by checking all connections, replacing the drivers/ Controller, surge protection device,control wiring copperwire and lugs, battery, solar PV modules all as directed by Engineer in charge.Comprehensive maintenanace also includes taking down street light fitting of any capacity from any height from the pole and increase or decrease the height of the fixing arrangement by removing the bent pipe and clamps and refixing itto the proper height and removing all the hanging wires, cables, PVC pipes, old rusted clamps, hanging aluminium wires, hanging grasses etc and tightening of all nuts, bolts, clamps and fixing of the street light at proper directionto the satisfaction of Engineer in charge) Spares under Comprehensive Maint should be measured and paid Seprately complete all as specified and directed Notes:- (i)T&P including ladder for repair works shall be arranged by the contractor at his own cost. (ii) Spare parts required to be replaced under comprehensive maintenance shall be measured & paid separately under respective items of BOQ as supply only. However, quoted rate is deemed to included for fixing element of supply only items. (iii) Repair team for the street lights shall be available all the time to carry out maintanance works.
16Supply & Fixing 100 AH battery (Tubular) for solar light fix on pole with fixing arrangement complete all as specified and directed.
17Supply & Fixing charge controller/ smart solar street light controller for exsiting Solar LED light complete all as specified and directed
18Supply & Fixing LED light 30W watt for solar light including wiring complete all as specified and directed
19Reapirs and maintenance of Street light timer panel, cleaning the panel by blowing air cleaning all dust and dirt from inside the panel checking all connection of panel and replacement of power and control wiring of all connections as per standard for MCB TPN, Timer bypass switch, timers, Connectors with providing of lugs and making the panel serviceable complete all as specified and directed Note :- The items such as MCBs, timer, contactor etc shall be measured and paid separately as supply only under respective item of BOQ.
20Attending complaint of loose connections in street lights, junction boxes, timer switch panel, setting of time as per users requirements etc complete all as specified and directed
21S & F in repairs MCCB Four pole, 100 Amps, 16 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
22S & F in repairs MCCB tripple pole with neutral, 100 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed
23S & F in repairs MCCB Four pole, 63 Amps, 16 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed
24S & F in repairs MCCB tripple pole with neutral, 63 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed
25SupplyonlyMCB, TPN,63 Amps, 415 volts, 10 KA complete all as specified and directed
26Supply only MCB, SPN,63 Amps, 230 volts, 10 KA complete all as specified and directed
27Supply onlyMCB, SP,06-32 Amps, 230 volts, 10 KA complete all as specified and directed
28S&F in repair astronomical + digital timer switch 110 to 240V AC, LED indication complete all as specified and directed.
29Supply Only 3 Phase, 3 Pole power contactor of AC3 current rating 40 Amp 415 V ML3 with 2NO & NC robust suitable for street light control timer panel complete all as specified and directed.
30S&F in repair contactor 40 Amps (MNX40) suitable for street light timer complete all as specified and directed
31Supply onlyTPN 4 way connector 100A each pole complete all as specified and directed
32Supply and fixing of PVC insulated stranded copper conductor size 10 sqmm single core for power wiring of street light timer panel complete all as specified and directed
33Supply and fixing of copper lugs pin type suitable for cable of size 10 sqmm complete all as specified and directed
34Disconnecting/ dismantling and removing unserviceable time switch board of any descriptionand S&F of automatic street light switch using Infrared Sensor based NATURE SWITCHfor automatic switching of street lights. Nature switch operation switch operation should be basedon Natural light Lux level. Required illuminancelevel for Switching ON is<= 30 lux andfor switching OFF>=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours. The sensor along with suitable Power contactors, incoming-outgoing MCB"s and Auto manual(Sensor By-pass) selection option should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, termite proof and FR grade IP66 protection class 2 Enclosure made of thermoplastic polycarbonate and protected against weather influences. For three phase load of 5KW (Swadeep02 EC dual series-5kW3P) with: 3 Nos contactors, 3 nos incoming MCB"s & 3 nos outgoing MCB"s of 20-25 Amps each and 1 No time switch & circuit wiring (copper) of min 10 sqmm complete all as specified and directed
35Repair/servicingincluding replacement of unserviceablemotor operated swivelling type high intensive search cum flood light control gear motor and fiber based roating disc of revolving mechanism motor,inbuilt speed reduction unit (5-10 RPM) speed control unit with reverse forward facility and all motor overhauling,servicing,including neccessary spare parts changing complete all as specified and directed
36Dismantling and taking out old unserviceable search lights and supply and fixing of Hi-intensity, long beam, LED search light 300W multi circuit SMD, focus range 800Mtr, CCT 5500K LM6 body dia >440mm, operating voltage :90V-300V,50Hz PF>.95,THD 70 Optics used-PMMMA/PC lens narrow beam 7 degree averagelux level>9000 with circuit of approx, 1Mtr toughened with silicon gasket, over/under volt and short circuit protection confirmating to LM79, LM 80, IK07, IP66, Lux Cert, Type tested IS 10322, IS 15885 and B.I.S. suitable to installed on existing rotating disc of revolving Mechanism of Kaline complete all as specified and directed
37S&F in repair High efficency LED street light of 70 Watt with aluminium pressure die cast housing toughened glass in the front and Peanuts lens for batwing light distribution and suitable Bracket Made up of GI pipe 0f 40 mm with 4 Nos of Fastners for Fixing LED fitting in Wall and Necessary Electconnection cable from ceiling rose to fitting .make orient/Philips/Havells complete all as specified and directed
38S&F in repair High efficency LED street light of 90 Watt with aluminium pressure die cast housing toughened glass in the front and Peanuts lens for batwing light distribution and suitable Bracket Made up of GI pipe 0f 40 mm with 4 Nos of Fastners for Fixing LED fitting in Wall and Necessary Electconnection cable from ceiling rose to fitting .make orient /Philips/Havells complete all as specified and directed
39S&F in repair of aesthetically designed LED security light luminiareis of 70 Watts system wattage for energy saving having IP 66 degree of protection, with minimum system efficiency as>85%, made ofpressure die casting aluminum housing powder coated in graphite grey andheat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120-270V AC, THD<10%, P.F>.95 The fitting should have in built surge protector of 10 KV and CRI>70 with CCT 5700 K complete all as specified and directed
40S&F in repair of aesthetically designed LED security light luminaires of 20Watts/25 Watts system wattage for energy saving having IP 65 degree of protection,with minimum system efficiency as>85%, made ofpressure die casting aluminum housing powder coated in graphite grey andheat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light Fitting should have operating voltage range of 120-270V AC, THD<10%, P.F>.95 ,The fitting should have in built surge protector of 10 KV omplete all as specified and directed.
41S&F in repair of aesthetically designed vertical type LED vertical downlight suitable for hangar lighting of 150 watts system wattage for energy saving having IP 65 degree of protection, with minimum system efficiency as>85%, made of pressure die casting aluminum housing power coated in graphite grey andheat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120-270V AC, THD<10%, P.F>.95,The fitting should have in built surge protector of 10 KV complete all as specified and directed
42S&F in repair of aesthetically designed vertical type LED Floodlight luminaires of 250 watts system wattage for energy saving having IP 66 degree of protection, with minimum system efficiency as>85%, made of pressure die casting aluminum housing power coated in graphite grey andheat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120-270V AC, THD<10%, P.F>.95complete all as specified and directed
43Supply & Replacment exclusive innovative designed, long life versatile pressure die-cast aluminium IP65 flood light 150W luminaire with high power LED Energy Efficientto illuminate large areas as inapplication of 16 mtr as light source The fitting should have in built surge protector of 10 KVwith Complete mounting assoceries complete all as specified and directed.
44S&F in repair High efficency IP 66 integral flood light with pressure die cast aluminium housing and toughened glass in the front suitable of45 Watt .Make. Orient, Cat No LFGM-045-C /Havells/Philips
45Supply & Replacment exclusive innovative designed, long life versatile pressure die-cast aluminium IP65 flood light 300W luminaire with high power LED Energy Efficientto illuminate large areas as inapplication of 16 mtr as light source The fitting should have in built surge protector of 10 KVwith Complete mounting assoceries complete all as specified and directed.
46Supply and fix in repair energy saving environmental friendly long life asthetically designed with symmetrical distribution with high power LEDlightpost top lantern fitting25 watt including taking down old unserviceable complete all as specified and directed Make : Havells , Cat No. RUBYPT25WLED757PSYMTOPC/ ORIENT / PHILIPS
47Supply and fixing of Motion/Thermal sensor LED Street light fittings 72 watt, 220 V AC complete with driver, holders & LED lamp suitable for wall including connecting up with driver three core flexible copper conductor , inbuilt electronic driver with motion sensor, Pf .9, Efficiency 100 Lm/W, Sensor range 5 Mtr at an angle 360 degree, High efficiency thermal design,wide spread of light to cover maximum area, with 10 KV surge protection including connecting up with driver three core flexible copper conductorall as directed and specified Make: polycab INTENSOcat. no LDO0103080/ equivelent in philips/ crompton/Bajaj Note: (i) When switch on detect motion it again to full intensity (100%) eventually dims when detect sensor in next 10 Second and as motion recedes it switchs to power saving mode 30 %
48Supply and installation of steel tubular swaged pole complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type confirming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including providing 5Nos synthetic enemelled paint bends(in skyblue and white coloure) of 30cm each as in repairs, complete all as specified and directed as in repairs for 410 SP-31 (9 mtr long) complete all as specified and directed. Note: All excavation / earth work and concrete work shall be mesured and paid separately under respective item of BOQ.
49M&L for preparation of existing old painted surface of any description os LT steel tubular electric pole/struts of any height and painting complete including bracing clamps and cross arms/channel caplet etc with one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5M height from ground level/top of PCC copping complete all as specified and directed
50Material and labour for marking of pole Number on PCC/ steel tubular pole by making a circle of 115 mm dia with Black synthetic enemmeled paint and marking pole number over it with whitefluorescent paint with stancil cut in decorative manner complete all as specified and directed
51M&L for preparing old painted surfaces of LT PCC pole of any description/ height and painting completewith two coats of snow white weather proof paint and providing white/blue alternative strips of 30 cm width each all around the poles up to 1.5M height from ground level/top of PCC coping including painting to bracing clamps and cross arms/channel caplet etc with one coat of aluminium paint complete all as specified and directed
52Trimming of branches on tree top up to 2.5m long and n.exc 50 mm dia coming in contact with street light poles irrespective of the size of the tree and cleaning all around the poles for grassses etc upto the Six meter dia around the pole by using necessary tools and ladders etc complete all as specified and directed
53Cleaning the unwanted grass/bushes around the street light pole up to .6 Mtr radius complete all as specified and directed
54Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for laying of cables etc complete all as specified and directed
55Excavation in trenches not exceeding 1.5m wide and exceeding 1.50 but not exceeding 3.0m in depth and getting out in soft/loose soil for laying of cables etc complete all as specified and directed
56Removing surplus excavated soil to a distance not exc 50m and depositing where directed at level n. exc 1.5m above the starting point complete all as specified and directed
57Returning, filling in, excavated soil in trenches including spreading, leveling watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed
58M&L for sand cushioning with using clean dry and natural river sand including gently punning below/around cable complete all as specified and directed. Note: Depth of the sand shall be measured after punning.
59M&L for well burnt bricks sub class ‘B’ as in protection of cable laid dry, flat abutting each other width wise complete all as specified and directed
60M&L for PCC 1:2:4 type B1 (using 20mm graded agregate) in coping of polesincluding form work complete all as specified and directed
61M&L for PCC 1:3:6 Type C2 (using 40mm graded agregate) as in foundation of polesincluding form work complete all as specified and directed
62PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation of electric poles including necessary from work and exposed surfaces finished fair without using extra cement complete all as specified and directed
63Supply and Layingin trenches/fixed on walls/poles or passing through pipes, PVC insulated,armoured, heavy duty LT U/G electric cable of size 16 Sqmm x 4 core with aluminium conductor 1100 volts grade with suitable cable glands and lugs etccomplete all as specified and directed
64Supply and Layingin trenches/fixed on walls/poles or passing through pipes, PVC insulated armoured heavy duty LT U/G electric cable of size 25 Sqmm x 4 core with aluminium conductor 1100 volts grade with suitable cable glands and lugs etccomplete all as specified and directed
65Disconnecting andremoving of burnt cable end terminal of existing Under ground cable from street light junction boxes with protection pipe excavating and taking out cable loop cutting and making new connection with cable lugs and fixing cable protcetion pipe with suitable size of clamps nut bolts with existing one including refillingthe excavated portion matching with existing surfaces complete all as specified and directed
66Making proper connection of disturbed/ removed street light junction box with cable protection pipe includingnecessaryD clamp ,nut bolt and washers etc complete all as specified and directed
67M&L for welding of existing broken panel doors and fixing good quality hinges(any size any number of hinges per panel) of suitable size for making the panel doors functional and fixing/welding angle for the locking arrangements of the door including welding and making good any other broken portion of panel including all painting work as required to match with existing complete all as specified and directed Note:. Suitable size of sheet steel as per existing thickness and shape if required additional are to be included in the quoted rate.
68Supply and fixing of PVC round shapepost top lantern /garden lights suitable to in fixed on 40mm dia GI pipe with lamp holder (B-22 )and LED lamp complete all as specified and directed
69Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular size 4 sqmm complete all as specified and directed
70Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular size 6 sqmm complete all as specified and directed
71Dismantling/ taking out old defective sub main wiring for Hangar at a height of 18 meter from ground level and M&L for new sub main wiring using two runs single core 4.0 Sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including ERW steel conduit or in existing conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc and connecting to earth dolly and including 2.5 Sqmm FRLS copper earth wire, PVC insulated & unsheathed complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of2 sqmm earth wire and one run of conduit shall be measured as one unit. (ii) Necessary plastering tothe disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the quoted rate.
72S&F in repair of aviation/obstruction light fitting 2 x 6 watts, IP 65 rating, 230V, AC with all connection accessories as nuts, bolts, clamps as per site requirement complete all as specified and directed.
73M & L for rewinding of high-powered electrically driven internally mounted 3 phase power motor of capacity 3 HP for raising and lowering of the lantern carriage of high mast light by using best quality super enamelled copper winding wire of existing gauge and existing number of turns including varnishing for "F" class insulation and drying in heat chamber and refixing, testing, commissioning complete all as specified and directed.
74M&L for stainless steel wire ropes with overall diameter of the rope not less than 6mm and the breaking load of each rope shall not be less than 2000 Kg suitable for high mast light complete all as specified and directed.
75M&L for repairing/servicing the raising and lowering mechanism of high mast light with opening the gear box and greasing of all movingparts for smooth functioning of raising and lowering of the lantern carriage for maintenance purposes complete all as specified and directed.
76S&F in repair contactor 63 Amps (ML 3) suitable for street light timer complete all as specified and directed
77Dismantling/ taking out old defective conduit of any type from street light poles (Junction box to street light fitting) and S&F MS conduit pipe of size 20 mm fixed to pole with suitable clamps/ fixing arangements etc complete all as specified and directed.