Repair / Replacement Of External Water Supply Items Such As Ci/ Control Valve, Ci/Gi/Di Pipes, Valve Chambers, Etc In Long Range, Singarathoppu, Ava Hill, Stable Hill, Jcos Map Area And Repairs/ Servicing Of Dg Sets, Amf Panels, Solar Lights And Panels, C, wellington-Tamil Nadu

Military Engineer Services-MES has published Repair / Replacement Of External Water Supply Items Such As Ci/ Control Valve, Ci/Gi/Di Pipes, Valve Chambers, Etc In Long Range, Singarathoppu, Ava Hill, Stable Hill, Jcos Map Area And Repairs/ Servicing Of Dg Sets, Amf Panels, Solar Lights And Panels, C. Submission Date for this Tender is 09-12-2023. Air Conditioner Tenders in wellington Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40684566
Corrigendum : Repair / Replacement Of External Water Supply Items Such As Ci/ Control Valve, Ci/Gi/Di Pipes, Valve Chambers, Etc In Long Range, Singarathoppu, Ava Hill, Stable Hill, Jcos Map Area And Repairs/ Servicing Of Dg Sets, Amf Panels, Solar Lights And Panels, C
Open Tender
Indian
Tamil Nadu
wellington
09-12-2023

Tender Details

Repair / Replacement Of External Water Supply Items Such As Ci / Control Valve, Ci / Gi / Di Pipes, Valve Chambers, Etc In Long Range, Singarathoppu, Ava Hill, Stable Hill, Jcos Map Area And Repairs / Servicing Of Dg Sets, Amf Panels, Solar Lights And Panels, Cooling Appliances, Refrigerators And A / C Plants Etc At Wellington Area Under Ge Wellington

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-12-2023
2 04-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 67000.0 /-
Tender Value
INR 33.50 Lakhs /-

BOQ Items

Name of Work: REPAIR / REPLACEMENT OF EXTERNAL WATER SUPPLY ITEMS SUCH AS CI/ CONTROL VALVE, CI/GI/DI PIPES, VALVE CHAMBERS, ETC IN LONG RANGE, SINGARATHOPPU, AVA HILL, STABLE HILL, JCOs MAP AREA AND REPAIRS/ SERVICING OF DG SETS, AMF PANELS, SOLAR LIGHTS AND PANELS, COOLING APPLIANCES, REFRIGERATORS AND A/C PLANTS ETC AT WELLINGTON AREA UNDER GE WELLINGTON
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in hard/ dense soil for laying of GI/DI Pipe all as specified and directed.
2Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 Cms thickness all as specified and directed.
3Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
4Dismantling the existing broken valve chamber completely and construction of new valve chamber 230mm thick having inner dimension 600mm x 600mm x 860 mm suitable for valve of size upto 50 mm gate valve with PCC 1: 4: 8 type D2 for foundation, using 40mm graded stone aggregate brick work in cement mortar (1:4), PCC 1: 2: 4 type B1 using 20mm graded stone aggregate for coping, rendering in CM 1:4, 15mm thick including provision of MS Sheet top cover 2 mm thick with fixed to MS angle iron ofsize 40 mm x 40mm x 4mm thick,painting with two coats of synthetic enamel paint over a coat of red oxide primer and locking arrangements with lock and key including tarring to the embedded steel surfaces, necessary excavation earth work complete all as specified and directed.
5Dismantling the existing broken valve chamber completely and construction of new valve chamber 230mm thick having inner dimension 900mm x 900mm x 860 mm suitable for valve of size above50 mm and up to 80/100mm gate valve with PCC 1: 4: 8 type D2 for foundation, using 40mm graded stone aggregate brick work in cement mortar (1:4), PCC 1: 2: 4 type B1 using 20mm graded stone aggregate for coping, rendering in CM 1:4, 15mm thick including provision of MS Sheet top cover 2 mm thick with fixed to MS angle iron ofsize 40 mm x 40mm x 4mm thick,painting with two coats of synthetic enamel paint over a coat of red oxide primer and locking arrangements with lock and key including tarring to the embedded steel surfaces, necessary excavation earth work complete all as specified and directed.
6Dismantling the existing broken valve chamber completely and construction of new valve chamber 230mm thick having inner dimension 1200mm x 1200mm x 860 mm suitable for valve of size more than 100 mm gate valve with PCC 1: 4: 8 type D2 for foundation, using 40mm graded stone aggregate brick work in cement mortar (1:4), PCC 1: 2: 4 type B1 using 20mm graded stone aggregate for coping, rendering in CM 1:4, 15mm thick including provision of MS Sheet top cover 2 mm thick with fixed to MS angle iron ofsize 40 mm x 40mm x 4mm thick,painting with two coats of synthetic enamel paint over a coat of red oxide primer and locking arrangements with lock and key including tarring to the embedded steel surfaces, necessary excavation earth work complete all as specified and directed.
7Ball valve/ float valves of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 15mm dia complete all as specified and directed. Make : Finolex/Prayag/Polytub
8Ball valve/ float valves of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20mm dia complete all as specified and directed. Make : Finolex/Prayag/Polytub
9Ball valve/ float valves of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25mm dia complete all as specified and directed. Make : Finolex/Prayag/Polytub
10Taking up/ down carefully unserviceable CI/DI pipe(including all fittings) with spigot and socket ends and joints, connections from the trenches of size of 100mm dia all as specified and directed.
11Taking up/ down carefully unserviceable CI/DI pipe(including all fittings) with spigot and socket ends and joints, connections from the trenches of size of 150mm dia all as specified and directed.
12Ductile iron pipe 100mm bore dia, spigot and socket ends, class "K-9" and including rubber gasket ( push on) joints of same make of DI pipe having two sections of different hardness for spigot and socket pipes as in trenches complete all as specified and directed. Make : Srikalahasthi pipe Ltd/Tata/electro steel/Tisco/jindal
13Ductile iron pipe 150mm bore dia, spigot and socket ends, class "K-9" and including rubber gasket ( push on) joints of same make of DI pipe having two sections of different hardness for spigot and socket pipes as in trenches complete all as specified and directed. Make : Srikalahasthi pipe Ltd/Tata/electro steel/Tisco/jindal
14Ductile iron specials such as bends, tapers, tee pieces (singleand double branch) any type and angle / radius and straight connecting piece but all ends socketed / flanged of size 80, 100 to 150mm dia bore all as specified and directed. Make : Srikalahasthi pipe Ltd/Tata/electro steel/Tisco/jindal
15Rubber gasket joint (tyton-Joint) for CI / DI spigot and socket pipe line of size 100mm dia bore including fixing and testing complete all as specified and directed.
16Rubber gasket joint (tyton-Joint) for CI / DI spigot and socket pipe line of size 150mm dia bore including fixing and testing complete all as specified and directed.
17Run lead joint for CI/DI spigot and socket pipe line of size 100mm dia bore all as specified and directed.
18Run lead joint for CI/DI spigot and socket pipe line of size 150mm dia bore all as specified and directed.
19Taking up or down carefully unserviceable GI steel tubing and connections from the trenches/walls/floors etc of 15mm dia and connections including cleaning for refixing or removing from site all as specified and directed.
20Taking up or down carefully unserviceable GI steel tubing and connections from the trenches/walls/floors etc of 20mm dia and connections including cleaning for refixing or removing from site all as specified and directed.
21Taking up or down carefully unserviceable GI steel tubing and connections from the trenches/walls/floors etc of 25mm dia and connections including cleaning for refixing or removing from site all as specified and directed.
22Taking up or down carefully unserviceable GI steel tubing and connections from the trenches/walls/floors etc of 40mm dia and connections including cleaning for refixing or removing from site all as specified and directed.
23Taking up or down carefully unserviceable GI steel tubing and connections from the trenches/walls/floors etc of 50mm dia and connections including cleaning for refixing or removing from site all as specified and directed.
24Taking up or down carefully unserviceable GI steel tubing and connections from the trenches/walls/floors etc of 80mm dia and connections including cleaning for refixing or removing from site all as specified and directed.
25Steel water tubing medium grade galvanized with all fittings and laid in trenches / fixed on walls / floors of size 15mm bore all as specified and directed.
26Steel water tubing medium grade galvanized with all fittings and laid in trenches / fixed on walls / floors of size 20mm bore all as specified and directed.
27Steel water tubing medium grade galvanized with all fittings and laid in trenches / fixed on walls / floors of size 25mm bore all as specified and directed.
28Steel water tubing medium grade galvanized with all fittings and laid in trenches / fixed on walls / floors of size 40mm bore all as specified and directed.
29Steel water tubing medium grade galvanized with all fittings and laid in trenches / fixed on walls / floors of size 50mm bore all as specified and directed.
30Steel water tubing medium grade galvanized with all fittings and laid in trenches / fixed on walls / floors of size 80mm bore all as specified and directed.
31Cutting existing steel tubing of 15mm bore for alterations and screwing existing steel tubing with all required acessories such as Tee, Nipple, Union and Elbow etc including excavation, returning filling and removal and making good of existing surface complete all as directed.
32Cutting existing steel tubing of 20mm bore for alterations and screwing existing steel tubing with all required acessories such as Tee, Nipple, Union and Elbow etc including excavation, returning filling and removal and making good of existing surface complete all as directed.
33Cutting existing steel tubing of 25mm bore for alterations and screwing existing steel tubing with all required acessories such as Tee, Nipple, Union and Elbow etc including excavation, returning filling and removal and making good of existing surface complete all as directed.
34Cutting existing steel tubing of 40mm bore for alterations and screwing existing steel tubing with all required acessories such as Tee, Nipple, Union and Elbow etc including excavation, returning filling and removal and making good of existing surface complete all as directed.
35Cutting existing steel tubing of 50mm bore for alterations and screwing existing steel tubing with all required acessories such as Tee, Nipple, Union and Elbow etc including excavation, returning filling and removal and making good of existing surface complete all as directed.
36Taking out existing unserviceable gunmetal gate valve of size 50/40/25/20 mm dia after dismantling existing union, nipple and cutting the rusted out thread and making new thread for inserting new gate valve all as specified and directed.
37Gunmetal gate valve with iron wheel head screwed both ends for iron pipe of size 50mm dia all as specified and directed.
38Gunmetal gate valve with iron wheel head screwed both ends for iron pipe of size 40mm dia all as specified and directed.
39Gunmetal gate valve with iron wheel head screwed both ends for iron pipe of size 25mm dia all as specified and directed.
40Gunmetal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm dia all as specified and directed.
41Gunmetal gate valve with iron wheel head screwed both ends for iron pipe of size 15mm dia all as specified and directed.
42M&L for attending emergencybreak down complaints pertains to break down of under ground DI/CI/GI pipe of dia 80/100/150 mm. Note : The cost corresponding excavation work and materials will be measured and paid seperately. Sufficient number of plumbers and helpers to be engaged to complete the work within directed time period without any interruption to daily supply routine.
43Taking down old unserviceable sluice valve and Supply and fix PN-1.60 sluice valve cast iron double flanged type non raising spindle with hand wheel and fixed by means of suitable bolts and nuts etc,after putting new rubber gasket etc for 80mm dia all as specified and directed. Make : RMCO/VIR/KIRLOSKAR or Equivalent.
44Taking down old unserviceable sluice valve and Supply and fix PN-1.60 sluice valve cast iron double flanged type non raising spindle with hand wheel and fixed by means of suitable bolts and nuts etc,after putting new rubber gasket etc for 100mm dia all as specified and directed. Make : RMCO/VIR/KIRLOSKAR or Equivalent.
45Taking down old unserviceable sluice valve and Supply and fix PN-1.60 sluice valve cast iron double flanged type non raising spindle with hand wheel and fixed by means of suitable bolts and nuts etc,after putting new rubber gasket etc for 150mm dia all as specified and directed. Make : RMCO/VIR/KIRLOSKAR or Equivalent.
46Cutting PCC paving / road etc not exceeding 15cm thick for laying of Pipes all as specified and directed. Note: Only read thickness shall be measured under this item.
47PCC 1:2:4 type B-1 using 20mm graded stone aggregate upto 150mm thick for making good road, finished fair and even all as specified and directed.
48Taking down old unserviceable stop valve and supply and fix stop valve of 15mm size as specified and as directed.
49Rerouting the canal by constructing walling of size 3.5m x 0.45m x 1.5m of random rubble uncoarsed well bonded bedded with cement mortar of 1:6, making bed of PCC 10 cm thickness of 3.5m x 2.5m of type - D2 1:4:8 using 40mm graded stone aggregate alongwith and after finishing of civil works canal route is to be made as before. Note:The cost of work includes all earth work and JCB work for making route to canal, cutting bushes, trees etc.
50S&F water level monitoring instrument based on magnetic level sensing, sensor should sealed inside stainless steel and actuated by float and LED display givs level indication (5 stages of 20% each), automatic control of pump and warning alarms if level goes outside the automation range including all necessary electrical wiring from float to LED display.
51Servicing / repairs to DG Set 10 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on Filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 5 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 7.1 Ltr.
52Servicing / repairs to DG Set 15 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 5 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 7.1 Ltr.
53Servicing / repairs to DG Set 25 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 6.5 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 14.5 Ltr.
54Servicing / repairs DG Set 30 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smoth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on Filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 6.5 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 14.5 Ltr.
55Servicing / repairs to DG Set 35 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smoth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Element for lubricating oil - 1 No. (c) Kirloskar Oil Premium (Engine oil 15W 40) - 08 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 16 Ltr.
56Servicing / repairs to DG Set 45 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 08 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 16 Ltr.
57Servicing / repairs DG Set 50 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 09 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 20 Ltr.
58Servicing / repairs to DG Set 63 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Elementfor lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 09 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 20 Ltr.
59Servicing / repairs to DG Set 82.5 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Elementfor lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 12 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 20 Ltr.
60Servicing / repairs to DG Set 200 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smooth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Fuel Filter element (Pre) - 1 No (b) Spin on Filter Element for lubricating oil - 02 Nos (c) Kirloskar Oil Premium (Engine oil 15W 40) - 16 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 22 Ltr. (e) Air Filter Element - 01 No. Note for Item 51 to 60: Servicing / Repair to DG Set for Item Sl. No. 51 to 60 is to be carried out through authorised service centre of OEM duly approved by accepting officer and test report of the same has to be submitted on completion of work.
61Taking down old unserviceable Battery of any size, Supply and fix of battery 12 volts 90 AH plates complete all as specified and directed. Make: Exide GENPLUS or equivalent to Amron/ TATA
62Taking down old unserviceable Battery of any size, Supply and fixofbattery 12 volts 180 AHplates complete all as specified and directed. Make: Exide GENPLUS equivalent to Amron/ TATA
63Supply and fill Electrolite water for battery use all as specified and directed.
64Supply and fill distilled water for Solar water heater and for battery use all as specified and directed.
65Repairs to Self starter 12 volts duly rewinding and replament all required accessories etc ofDG sets capacity from 10 KVA to 63 KVA DG set complete andtesting including all as specified and directed.
66Repairs to Self starter 24 volts duly rewinding and replament all required accessories etc ofDG sets capacity 200 KVA DG set complete and testing includingall as specified and directed.
67Power contactor 4 pole type MCX-41 in repairs including taking down old unserviceable contactor complete all as specified and directed.
68S&F 4 pole change over switch with sheet steel enclosure 63 Amps capacity including taking down old changeover complete all as specified and as directed.
69S&F 4 pole change over switch with sheet steel enclosure 40 Amps capacity including taking down old changeover complete all as specified and as directed.
70Taking down old unserviceable generator controller, supply and fixingKG 394 (Version 2) KOEL GREEN generator controller complete all as specified and as directed.
71Servicing / repairs and testing ofsolarstreet light panel of any model including removing electrical connection and checking panel battery, replacement of spares etc all as specified and directed.
72Supply and replace 12 amps charge control unit 12 volts all as specified and directed.
73Supply and replace 12 volts 100 Ah Tubular battery all as specified and directed. Make: Exide/ Amron/ TATA
74Supply and replace 22 Watts solar LED fitting with CCU matching with existing make and size all as specified and directed
75Servicing / repairs and testing of solar water heater and checking panel and replacement of spares etc. all as specified and directed. Note: (i) Spares will be measured and paid separately. (ii) Spares to be changed shall be of same make as per existing.
76Supply and replace Heating Elementas per existing model for solar water heater all as specified and directed.
77Supply and replace toughened glass for solar collector of solar water heater complete all as specified and asdirected.
78M&L for air termination, single poined aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
79M&L for air termination, single pointed copper rod 12mm dia and 300mm long complete all as specified and as directed.
80M&L for test point terminal block made of gun metal or phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos of 8mm dia 25mm long hexagonal head screws complete all as specified and as directed.
81M&L for aluminium strip 25x3.15mm with saddles and fixing screws etc., for roof conductors and down conductors above ground complete all as specified and as directed.
82M&L for galvanised iron strips 32 x 6mm buried insid the ground all as specified and as directed.
83M&L for copper 20x3mm with saddles and fixing screws etc., for roof conductors and down conductors above ground complete all as specified and as directed.
84Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised iron strip 32 × 6mm means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.Note : On testing after completion of earthing, if earth resistance is found achieved below 5 Ohms, then the earthing will be redone completely without any extra cost.
85All as per Item No 84 above but using copper plate 60 x 60 x 3.15mm thick electrode and 20 x 3mm copper strip as earthing lead.
86Supply and fix in replacement of 25 Sqmm 4 core of 1100 volts LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded alumimum conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including taking out the oldunserviceable LT cable complete all as specified and as directed.Note : Rate is deemed to be inclusive of connecting up with control gear including cable glands and cable lugs complete.
87Supply and fix in replacement of 50 Sqmm 3.5 core of 1100 volts LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded alumimum conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including taking out the oldunserviceable LT cable complete all as specified and as directed.Note : Rate is deemed to be inclusive of connecting up with control gear including cable glands and cable lugs complete.
88Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying under ground cable completeall as specified and directed.
89M&L for cutting PCC paving / road 200mm thick for laying of cable complete all as specified and directed.
90Supply and spreading excavated earthed filtered soil in trenched as cushioning to under ground cable on top and bottom of cable complete all as specified and as directed.
91Supply and laying reinforced precast concrete cable cover class LV,Type I, flat size 250 x 150 x 40mm complete all as specified and as directed.
92M&L for PCC 1:2:4 type - B1using 20mm graded stone aggregatefor making good of road finished fair and even and pole coping complete all as specified and directed.
93M&L for light grade GI pipe 40mm dia for cable protection complete all as specified and as directed.
94Alternator (battery charger) 14 volts 35 Amps duly rewinding and replament all required accessories etc of DG sets capacity from 10 KVA to 200 KVA DG set including fixed in repairs complete and testing all as specified and directed
95Battery lead copper of 50 sqmm as per sample (Red and Black colour) and taking down old unserviceable battery lead all as specified and directed
96Battery terminal positive marking /negetaive marking of brass of existing size and taking down old U/S battery terminalall as specified and directed.
97M&L for painting the external exposed surfaces of steel poles of 9 metres long with cross arms, bracket and connected accessories and LT panel boards with one coat of aluminium paint including prepertaion of old painted surfaces and pasting radium red stickers complete all as specified and as directed.
98M&L for DG set door hingesbolt nut type suitable for existing DG set door size complete all as specified and as directed.
99Taking down the deffective sealed compressor from the unit and supply and fix factory reconditioned rotory/ receprocating type compressor 1.5 Ton capacity obtained from the rechange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agents, flushing throughly with CO2/N2, removal of complete dirt oil and certain, etc. Pressure testing dehydration, Vacumising, charging R-22/33A gas, testing and commissioning of the 1.5 Ton capacity all as specified and as directed.
100Taking out defective condenser fan blade of split type A/C 1.5 Ton capacity and supply and fix in new fan blade of same type balancing for smooth rotation in the casing and testing all as specified and directed.
101Cleaning/ flushing out the refrigeration system thoroughly with CO2/N2. vaccumising and charging with refrigerant gas and compessor oil testing at workshop and commissioning the system of 1.5 ton capacity split/ Window type AC all as specified and directed.
102Supply and fix in replacement inner unit fan motor with runner of suitable capacity for split / Window type AC of cap 1.5 ton all as specified and directed.
103Supply and fix in replacement running capacitor36/45 mfd, 3 pinsuitable for split/ Window AC of cap 1.5 ton all as specified anddirected. Make- Efcos, Sycap, Keltron
104Supply and fix in replacement indoor fan capacitor 1.5 mfd suitable for split/ Window AC of cap 1.5 ton all as specified anddirected. Make- Sriram, Reneutrol, CSR 127
105Supply and fix in replacement filter suitable for split AC of cap 1.5 ton all as specified anddirected. Make- Sriram, Reneutrol, CSR 127
106Supply and fix in replacement indoor evaporator unit suitable for split AC of cap 1.5 ton all as specified anddirected. Make-Sriram, Reneutrol, CSR 127
107Supply and fix in replacement drain out pipe of required size and length of indoor unit suitable for split AC of cap 1.5 ton all as specified anddirected. Make-Sriram, Reneutrol, CSR 127)
108Taking out the damaged suction line pipe and supply and fixing new copper pipe of size 1/2" in brazing, pressure testing for 1.5 Ton capacity split type AC all as specified and directed.
109Supply and charging of refrigerent gas R22/33A in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed.
110Supply and charging of refrigerent gas R134A/R410Ain cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed.
111Supply and fix in replacement PVC insulated and sheathed flexible cable 3 core stranded copper conductore of size 4.0 Sqmm in proper size saddle 1100 volts grade after taking out old unserviceable one including electrice connection complete all as specified and as directed.
112Supply, fix in replacement relay 5 pin type suitable for 1.5 Ton capacity all as specified and as directed. Make-Sriram/ Arvind / Annapuma.
113Supply, fix in replacement Over load protector suitable for 1.5 Ton capacity all as specified and as directed. Make- Sriram,Arvind/ Annapuma.
114Supply, fix in replacement thermostatic switch suitable for window/ split type AC 1.5 Ton capacity all as specified and as directed. Make-Indofoss / Danfoss
115Supply, fix in replacement Air conditioner Kit suitable for window / Split type AC 1.5 ton cap having cabinet box, cooling coil, condenser unit all as specified and directed. Make Samsung/ Voltas
116Taking down the deffective sealed compressor from the unit and supply and fix factory reconditionedcompressorobtained for the exchange of old compressor including deaning the refrigeration circuit with appropriate cleaning agents, flushing throught with CO2/N2 brazing the line . Pressore testing rectification of leakages,dehydration, Vacumising, charging R-134A gas. Replacement of copper pipe, copper strainer, topping up compressore oil incl transportation of the unit to the workshoptesting and commissioning of 165 to 220 Ltrs Capacity refrigerator all as specified and directed. Make:- LG , Whirlpool, Samsung.
117All as per item No.116 hereinbefore but 250 to 350 Ltrs Capacity refrigerator all as specified and directed. Make:- LG , Whirlpool, Samsung.
118All as per item No.116 hereinbefore but Deep freezer of Capacity 200 to 300 Ltr all as specified and directed. Make:- LG , Whirlpool, Samsung.
119Gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vaccumising, charging of R134A gas, replacement of copper pipe, copper strainer, ropping up compressor oil including transportation of the unit to the work shop testing and commisioning the refrigerators of 165 to 220 Ltr Cap all as specified and directed. Make:- LG , Whirlpool, Samsung.
120All as per item No.119 hereinbefore but refrigerators of 250 to 350 Ltr Cap all as specified and directed. Make:- LG , Whirlpool, Samsung.
121All as per item No. 119 hereinbefore but Deep Freezer of capacity 200 to 300 Ltr all as specified and directed. Make:- LG , Whirlpool, Samsung.
122Supply, fix in replacement relay suitable for Refrigerator /deepfrezer of any capacity as per existing model all as specified and directed. Make :-Sriram, Indfoss, Danfoss
123Supply, fix in replacement overload protector suitable for Refrigerator /deepfrezer of any capacity as per existing model all as specified and directed. Make :-Sriram, Indfoss, Danfoss
124Supply, fix in replacement thermostatic switch of auto de-frost suitable for Refrigerator /deepfreezer of any capacity as per existing model all as specified and directed. Make :-Sriram, Indfoss, Danfoss
125Taking down the defective unserviceable evaporator unit and pipe connection and accessories and supply and fixing new set for refrigerator of 165 to 220 Ltr Cap all as specified and directed.
126Taking down the defective unserviceable evaporator unit and pipe connection and accessories and supply and fixing new set for refrigerator of 250 to 350 Ltr Cap all as specified and directed.