Tender For Repair / Replacement And Day To Day Maintenance Of Lt Distribution System / Lt Panel / Apfc Panel / Lt Poles At Darjipura At Afs Baroda, baroda-Gujarat

Military Engineer Services-MES has published Tender For Repair / Replacement And Day To Day Maintenance Of Lt Distribution System / Lt Panel / Apfc Panel / Lt Poles At Darjipura At Afs Baroda. Submission Date for this Tender is 05-12-2023. Electrical Panel Tenders in baroda Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

40684564
Corrigendum : Tender For Repair / Replacement And Day To Day Maintenance Of Lt Distribution System / Lt Panel / Apfc Panel / Lt Poles At Darjipura At Afs Baroda
Open Tender
Indian
Gujarat
baroda
05-12-2023

Tender Details

Repair / Replacement And Day To Day Maintenance Of Lt Distribution System / Lt Panel / Apfc Panel / Lt Poles At Darjipura At Afs Baroda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 81000.0 /-
Tender Value
INR 40.50 Lakhs /-

BOQ Items

Name of Work : REPAIR / REPLACEMENT AND DAY TO DAY MAINTENANCE OF LT DISTRIBUTION SYSTEM / LT PANEL / APFC PANEL / LT POLES AT DARJIPURA AT AFS BARODA
Sl. No. Item Description
1M&L for repair and rectification of external LTelectric supply complaints on 1100Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
2Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
3Taking out existing cable of following sizesfrom Junction boxes/overhead lines/LT Pannels/Poles/PCC Coping and cut out the worn out/burnt portion of cable, extend the cable from loop including excavation and refixing of the same after providing new lugs :-
43.5 Core 16 Sqmm to 50 Sqmm
53,5 Core 70 Sqmm to 240 Sqmm Note for item No 2.01 and 2.02:- (i) LT Jointing Kits, Cable protection Pipe, Excavation, Returning Filling, Removing, Sandand PCCcoping of polesif required at site will be measured and paid separately under relevant items. (ii) Old serviceable bricks received from the excavation shall be reused in work as cable protection. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
6Supply, install testing and commissioningin repair weather and vermin proof LT feedar pillarbus bar junction box (Panel board) factory fabricated (CPRI approved) Outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 60cm X 50 cm X 60 cm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of suffiecient Nos of circular cable entry holes at bottom onlywith suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with L.T armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium complete all as specified and directed ( as per sample) and consisiting of following :- (a)Bus bars of Aluminium strips of400 Amp current rating capacity, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator complete with CTs of suitable size with nut bolt fixing arrangement complete- 01 set (b)MCCB 100 Amp 4 pole 25 KA rating fixed type - 1 No.
7M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.
8M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
9M&L for Shackle type,Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
10S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FIclamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed.
11S&F of Galvanised steel wire (GI) 4mm dia including disconnecting/taking out old existing unsv GI wire complete all as specified and directed.
12M/L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section, 3mm Stainless steel Sheet incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed.
13S&F Loadline MCCB (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK), Adjustable thermal and fixed magnetic setting of capacity 400 Amps, 4 Pole, 36 KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed.
14Description all as per item Ser No 10.00 here-in-before but of capacity 250 Amps, 4 pole, 35 KA complete all as specified and directed
15Description all as per item Ser No 10.00 here-in-before but of capacity 200 Amps, 4 pole, 35/36 KA complete all as specified and directed
16Description all as per item Ser No 10.00 here-in-before but of capacity 200 Amps, 4 pole, 25 KA complete all as specified and directed
17Description all as per item Ser No 10.00 here-in-before but of capacity 125 Amps, 4 pole, 25 KA complete all as specified and directed
18Description all as per item Ser No 10.00 here-in-before but of capacity 100 Amps, 4 pole, 16 KA complete all as specified and directed
19Description all as per item Ser No 10.00 here-in-before but of capacity 63 Amps, 4 pole, 16 KA complete all as specified and directed
20S&F MCB 63 to 100 Amps, 4 pole, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
21S&F MCB, SP 6-32 Amps, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
22Supply and fixing surface mounting digital timer switch 240 Volts, 50 Hz, 16-32 Amps rating (For Street light/High Mast light) fitted inside steel enclosure complete all as specified and directed
23S&F street light control distribution boards Astronomical time switch along with suitable size of MS box made of sheet 2mm thick size 30mmx40mm duly powder coated with locking arrengement suitable for fixing at pole including two set of clamps comprising with the following complete all as specified and directe :- (i) MCB TPN 40 Amps 10 KA - 02 No.(for I/C and OG) (ii) Digital astronomical Timer with 2 NO+2NC suitable for operation of street light (iii) Contactor 3 pole 40 Amps 415 Volt coil operating voltage 230 volt -1 Nos (iv) Auto manual switch 10 Amps, complete all including internl connection done by using suitabale sie of copper wire
24S&F heavy duty power contactor 3 phase 415 volts 50 Hz of MNX 32 coilvoltage 230 volts, fitted inside steel enclosure complete all as specified and directed.
25S&F heavy duty power contactor 3 phase 415 volts 50 Hz of MNX 40 coilvoltage 420 volts, fitted inside steel enclosure complete all as specified and directed.
26Supplying, testing, laying and commissioning of cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, laid in trenches/duct or fied to wall/passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of the following sizes including disconnnecting/taking out existing unsv/damaged old LT UG cable complete all as specified and directed :- Notes : Earthwork, Sand and covers shall be measured and paid separately.
272 core X 10 Sqmm complete all as specified and directed
282 Core X 16 Sqmm complete all as specified and directed
294 Core X 16 Sqmm complete all as specified and directed
304 Core X 25 Sqmm complete all as specified and directed
313.5 Core X 35 Sqmm complete all as specified and directed
323.5 Core X 50 Sqmm complete all as specified and directed
333.5 Core X 70 Sqmm complete all as specified and directed
343.5 Core X 95 Sqmm complete all as specified and directed
353.5 Core X 120 Sqmm complete all as specified and directed
363.5 Core X 150 Sqmm complete all as specified and directed
373.5 Core X 185 Sqmm complete all as specified and directed
383.5 Core X 240 Sqmm complete all as specified and directed
39Taking down and relaying of existing exposed cable to underground of surface / re-using after jointing of straight through joint kit ofsize 3.5 Core 16 Sqmm to 240 Sqmm complete all as specified and directed:- Notes:- (a)Earthwork, sand and cable cover shall be measured and paid separately. (b)Existing cable / joint shall be used for relaying.
40Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long)including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
41Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in soft / loosesoil complete all as specified and directed.
42Description all as per item Ser No 26.00 here-in-before but depth exc 1.5 mtr but not exc 3 mtr complete all as specified and directed
43Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
44M&L filling sand in trenches for sand cushioning for laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment.
45M&L well burnt bricks sub class "B" as in protection of cable laid dry, flat abutting each other width wise complete all as specified and directed.
46M&L for PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as specified and directed
47M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as specified and directed
48Taking down / dismantling of unsv LT cable complete all as specified and directed
49Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
50M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe heavy duty of size 100 mm dia with 6 mm thick in any length including jointing materials to carry LT UG cables of size upto 400 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
51M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
52M&L repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
53M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paintincluding throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos blueand 2 Nos white) from ground level, complete all as specified and directed.
54M&L for Painting the existing LT PCCpoles with 1 coats of synthetic enamel base paintincluding painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 blue and 2white) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
55Material and Labour for cleaning and removing of vegetation, surface dressing surroundingLTpanel the panel, preparation of outer surface by grinder and remove all rusted portion, apply putty on rough surface , applying one coat of primer,sprey painting of panel with two coats synthetic enamel paint of existing colour or Approved coloure as suggested Enr-in Charge complete including providing lock complete all as specified and directed .
56Material and Labour for cleaning and removing of vegetation, bushes, surface dressing up depth not less than 10cm to remove the vegitation up to root surroundingthe all 11 KV Electric Installation premisses all around Approx 25-30 Sqmtr areacomplete including providing lock complete all as specified and directed Note :- The cleaning vegitation required quaterly, cleaning of each Quater measured one job for a installation.
57M&L earthing complete with galvanized steel earth plate electrode 60cmx 60cmx 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron GI Wire 4mm dia, by means of nuts, bolts,check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 20mm bore from earth electrode to test pointincl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in ant type of soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
58Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system complete all as specified and directed Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering, stringing the ACSR conductor, Fuse wire etc, if damaged during triming of branches.
59S&F new generation energy saving and environmental friendly long life LED street light made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KVBuilt-in-Surge Protection Device,road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.0 Sqmm PVC insulated copper conducter twin corecable etc, fixing on pole with and , fixed to Pole in any position with flat iron clamps of size 30 x 6 mm GI pipe light gradebreaket of 40mm dia of length 1200mm including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. fixing to wall/pole including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed.
60Description all as per item Ser No 44.00 here-in-before but 80 watts complete all as specified and directed
61Description all as per item Ser No 44.00 here-in-before but 70 watts complete all as specified and directed
62Description all as per item Ser No 44.00 here-in-before but 60 watts complete all as specified and directed
63S&F Energy saving, environmental friendly long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 150 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole including taking down old unserviceable light fitting of any type and capacity complete all as specified and directed. Note : (i) LED"s used should be the make of Cree/asram/Lumilieds/widchia (ii) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. (iii) Surge protection of the driver should be 10 KV
64S&F New generation, post-top, energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source of capacity 36 watts and all standard accessories etc fixed to main gate in any location and position complete all as specified and as directed.Make Cat Part No PCGLP 01400 of Make Polycab, Cat Part No HLPT-01-40-CW of Make Halonix, Cat Part No LLOP-30-C of make orient
65S&Fin repair HPSV copper ballast400W for flood light/Search Lightcomplete all as specified and directed
66S&Fin repair HPSV / MH lamp ignitor 400W for flood light/Search Lightcomplete all as specified and directed
67S&F in repair LED Driver suitable for upto 72 watts LED light fittings complete all as specified and directed.
68S&F in repair MH Lamp400W for flood light / search light complete all as specified and directed
69Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and as directed.
70Supplying, spreading and leveling Graded coarseAggregate in loose filling over dressed earth surfaceof guage 20-40mm nominal size in the installation yard complete all as specified and as directed.
71Supply and fixingin repair street light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified and directed
72Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular size 4 sqmmcomplete all as specified and directed
73Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular size 6 sqmm complete all as specified and directed
74Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed unarmoured twin core cable flat/round or circular size 10 sqmm complete all as specified and directed
75Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular size 10 sqmm complete all as specified and directed
76Taking out existing unwanted LT PCC pole by cutting from ground level and removed from site finishing the surface complete all as specified and directed
77Dismantling concrete poles/ struts, any size removed from site complete all as specified and directed
78M&L for boring under road with trench less tecnology including DWC HDPE pipe of 80mm dia complete for protection of HT cable complete all as specified and directed
79Supply and laying GI tubing light grade of size 40 mm for cable protection on road /drain /floor /pole including necessary clamps 40x4mm complete all as specified and directed
80Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed
81Supply and laying GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed
82Supply and fix in repair1 Sqmm two single core PVC insulated, PVC sheathed multistranded copper conductor flexible cable 1100 volts grade from junction box to street light fitting complete all as specified and directed
83S&F Junction box 290 x 200 x 130 mm Polycarbonate Hinged Enclosure box for cable in / out of street light LT cable, out door type, testing and commissioningwith locking arrangements fixed on poles 4 pole 100 Amp Connetor ,including MCB SP - 01 Nos for connecting suitable size of XLPE UG cablecomplete all as specified and directed.
84S&F LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed
85S&F LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed
86S&F LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed
87S&F in repair On-Load changeover switch (In sheet steel enclosure), AC 21 (Side Handle), 4 pole of capacity 250 Amps, 415 Volts, 50 Hz complete all as specifed and directed
88S&F in repair On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 160 Amps, 415 Volts, 50 Hz complete all as specifed and directed
89S&F in repair On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 63 Amps, 415 Volts, 50 Hz complete all as specifed and directed
90Supply only Aluminium cable lugs (lugs are made from 99.5% pure aluminium) as per IS of following Size complete all as specified and directed:-
9110 Sqmm Size complete all as specified and directed
9216 Sqmm Size complete all as specified and directed
9325 Sqmm size complete all as specified and directed
9435 Sqmm size complete all as specified and directed
9550 Sqmm size complete all as specified and directed
9670 Sqmm size complete all as specified and directed
9795 Sqmm size complete all as specified and directed
98120 Sqmm size complete all as specified and directed
99185 Sqmm size complete all as specified and directed
100240 Sqmm size complete all as specified and directed
101M&L for End termination joint indoor type for LT UG cable including jointing kits heat srinkable typecomplete suitable for aluminium conductor cables complete all as specified and directed for the following size:-
102Cable size from 16 to 50 sqmm3.5 core
103Cable size of 70 to 120 sqmm3.5 core
104Cable size of 120 to 185 sqmm3.5 core
105Cable Size 240 sqmm - 300sqmm 3.5core
106M&L for straight through joint outdoor type for LT UG cable including jointing kits heat srinkable typecomplete suitable for aluminium conductor cables complete all as specified and directed for the following size:-
107Size of 25 to 50 sqmm3.5 core
108Size of 70 to 120 sqmm3.5 core
109Size of 150 to 185 sqmm3.5 core
110Size of 240 to 300 sqmm3.5 core
111S&F in repairs Glow sign board of size 2 m x 1.5 m x 0.20 m made out of 1.0 mmthick tin sheet all side except front side aluminium beading "L" shape at all border exterior and interior side, front shall be Flex sheet 2.0 mm thick of blue colour and subject matter as given by the Engr-in-charge in english capital letter in white colour shall be written over it.Board shall be provided with and incl twin LED tubelight fitting 1x22 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm ((length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing complete as all spcified and directed.
112S&F in repairs Glow sign board of size 1.2 m x 0.9 m x 0.20 m made out of 1.0 mmthick tin sheet all side except front side aluminium beading "L" shape at all border exterior and interior side, front shall be Flex sheet 2.0 mm thick of blue colour and subject matter as given by the Engr-in-charge in english capital letter in white colour shall be written over it.Board shall be provided with and incl twin LED tubelight fitting 1x22 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm ((length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing as all spcified and directed.
113Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 125 KVARs and up 8/10 stages installed atvarious locations at AFS DarjipuraBaroda area including carrying out complete maintenance/repairs as required of all the sub systems viz. basedcontrol panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT,MCBs/MCCBs for isolation (with all the accessoires) anybreakdownmaintenance and replacement of unserviceable parts, refixingof old serviceable parts/new parts if anyproject completionand trouble shooting responsibility also lies with contractor complete all as specified and directed.
114Notes:- (i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, replacement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etcand necessary servicing repair by expert technician and register will be maintaned for the same. (ii)The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/ MCCB and fixing/installing /testing and commissioning the complete system. (iii) Measure components such ascapacitors bank, APFC relay, power contactor, control CT, MCBs/MCCBshall be measured and paid saperatly
115Supply only powerfactor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed.
116Description all as per item No 81.00 here-in-before but 10 KVAR Capactor Bank complete all as specified and directed.
117Description all as per item No 81.00 here-in-before but 15 KVAR Capactor Bank complete all as specified and directed.
118S&F APFC relay eta CON L series with auto-set function 3-8 stage, Model etaCON L3 including taking down old unserviceable one complete all as specified and directed.
119S&F in repairs capacitor duty contactor, type MOC built in auxillary contact blocks, 8.5 KVAR, 415 volts, 3 phase, 50 Hz, type MO C8.5 complete all as specified and directed.
120Description all as per item Ser No 85.00 here-in-before but capacitor duty contactor, type MO C12.5 complete all as specified and directed.
121Description all as per item Ser No 85.00 here-in-before but capacitor duty contactor, type MO C15 complete all as specified and directed.
122Supply only of insulation tap roll for cable protection of following sizes:-
12325 mm Size of 100 RM length complete all as specified and directed
12415 mm Size of 100 RM length complete all as specified and directed Notes for item Ser No 88.01 and 88.02 Insulation tape shall be taken on charge through proper RV.
125M&L for welding existing broken panel doors and fixing good quality hinges(any size any number of hinges per panel) of suitable size for making open and close the panel doors and fixing/welding angle/notch and Nut Bolts washers of suitable size to keep the door locked and including welding and making good any other broken portion of panel (double door also)complete all as specified and directed
126M& L for Repairing of LT Panel by cutting out Corroded/worn out body of LT Panel and refixing the 3.6mmStainless steel sheet with suitable Angleby suitable weilding,over and above where Base MS Channel of LT Panel is broken also to be changed with proper New Channel being suitable weilding/PCC work complete all as specified and directed Note Rate for MS Channel and stainless steel sheet will inclusive in this quoted rate
127Checking/testing of Earth resistance value of earthing pits Installed inside Darjipura, Makarpura, harni camp and Harni Airfield area as per requirement basis as directed by Engr in Charge or as schedule and making the damaged earthing serviceable by pouring salted water into earthing or making continuity by GI strips and bringing down the resistance value within specified limits. including maintenance of existing earthing by cleaning the earth chamber funnel and cleaning of vagetation surrouding earthing pit up to 2 mtr complete all as specified and directed
128Note: (i) The contrcator will deploy a team for eacheach DG set at darjipurato test the resistance value of earthings in each zone to complete the process within one month. The entire process will be repeated after every six months (half yearly) upto completion of the contract. (ii) one earthing testing in one season is measured one job. (iii) Digital Earth tester will be arrenge by the contractor his own. (iv) Date of testing and due date of testing is to be written on a register with sign ofuser rep & Engr-in Charge . (v) Testing and correction action is to be done within one month from date of commencement . earthings is to be completed within one month. Thereafter on half yearly basis or as directed by Engr-in charge and same is to be completed within one month.The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month. (vi) If any material required for improvement of resistence value which value is more than their permissible limit will be measured and paid seperately.
129M&L for sprinkling of ODYSSEY Herbicide near Two/Four Pole structure/LT Pannels/DG Sets/solar Pannel E/M Installationall as per Reqmt complete all as specified and directed. Note :-Herbicides will be sprinkled by Concerned sprinkling Machine onlyand not to manually. Sprinkling Machine will be provided by contractor.
130S&F with replacement ofGI strip 32 x 6 mm buried in ground after testing point complete all as specified and directed
131Supply onlySolar panel cleaner solution to removes foreign deposit brought on surface by industrial flash over dust, dirt and strains suitablecleaning ofModule/Top surface ofsolar Pannel/Module complete all as specified and directed
132Supply only Solar panel cleaning brush with 2 in 1 Microfiber brush and rubber with 4 meter fed Teliscopic pole 4 Meter aluminium complete all as specified and directed. Note:-Solar panel cleaner shall be taken on charge through proper RV.
133M& Labour for hiring of fault Locator Machinecomplete fromthe authorised supplier alongwith their team, finding out the exact LT fault location from both end termination of underground cable incl necessary excavation and earth work complete all as secified and directed