Tender For Repair And Maintenance Of 03 Phase Cooling Appliances Installed In Various Units At Chandimandir, chandimandir-Haryana

Military Engineer Services-MES has published Tender For Repair And Maintenance Of 03 Phase Cooling Appliances Installed In Various Units At Chandimandir. Submission Date for this Tender is 07-12-2023. Air Conditioner Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

40684515
Corrigendum : Tender For Repair And Maintenance Of 03 Phase Cooling Appliances Installed In Various Units At Chandimandir
Open Tender
Indian
Haryana
chandimandir
07-12-2023

Tender Details

Tender For Repair And Maintenance Of 03 Phase Cooling Appliances Installed In Various Units At Chandimandir- 1 Attending the daily complaints pertaining toACs three phase at site which includes the following(i)Checking elect circuit, tightening of loose elect connection including internal circuit of plant and ensure the functioning of the plant. Note :- (i) Spare parts if any required shall be measured and paid separately as supply only. (ii)Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging, leak testing etc mentioned as S & F/ M & L (iii) Work against entire quantity shall be completed within set schedule to be decided by Engineer-in-charge. (iv) All the plants shall be handed over on daily basis through proper documentation. (v) The deployed tradesman shall have technical qualification in the field and necessary documentary proof shall be produced by the contractor. (vi) For non attendance of complaints within 24 Hrs, penal charges @Rs 1000 per complaint per day shall be charged. (vii) Thorough care/ protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning. (viii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost. (ix)Each service shall be measured and paid separately as each job.(x) The technician must have the minimum qualification of ITI in Refg& AC from Recognize institute of Govt Approved.(xi) Pin valve, PVC tape etc shall be part of the job at no extra cost.(xii)The platform ladder arrangement upto 20ft high or 40 ft high by steel structure platform will be provide by the Contractor at no extra cost 2 Comprehensive maintenance of ACs (Hot & Cold) of capacity 8.5 Ton ductable ACs of make LG,by disconnecting/ dismantling of indoor and outdoor unit at site and refixing the same after repair/renewal of the defective spare parts (spare parts where required to be replaced shall be measured and paid separetly as supply only). Servicing of the ducts, drain pipe, cooling coil, condensing coil and adjusting the duct slope for free flow of drain water, testing of the complete set of Hot/Cold at desired temperature complete all as specified and as directed.Note:- (i)Gas charging, spare parts shall be measured and paid for separately under respective items. (ii)The contractor shall provide only the experienced and qualified staff for handling the sensitive works. (iii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor,gas charging, leak testing.(iv)Work against entire quantity shall be completed within set schedule to be decided by Engineer-in-charge. (v) All the plants shall be handed over on daily basis through proper documentation. (vi) Penal charges @ Rs 1000 per plant per day shall be charged for not following the schedule. (vii) Thorough care/ protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning. (viii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost. (ix)Each service shall be measured and paid separately as each job.(x) The Contractor to ensure and depute a technicien to the office for obtain complaint slip at 0900 hrs daily. 3 All as per item 2 here-in-before but for 5.0 Ton ductable type AC. Make: Amtrex LG/ Danfoss/ Indofos/ Copeland 4 All as per item 2 here-in-before but for 4 Ton cassette type / ductable type AC. Make: Amtrex LG/ Danfoss/ Indofos/ Copeland 5 All as per item 2 here-in-before but for 3 TR cassette type / Pillar type AC. Make: LG/Hitachi 6 Material for providing insulation on and around suction and discharge copper tube of size 1/2 and 1/4, 3/8 and 5/8 with 6 mm thick flexible thermocol heat resistance duly warpped with sticking tape and finally covered with flexible PVC conduit of 50mm dia complete all as specified and as directed. 7 Supply only ofAC 4 Pole power contactor three phase of capacity 25 Amp to 40 Amp suitable for pillar type AC-3 TR/5TR/8.5R complete all as specified and as directed. 8 Supply only liquid line drier filter suitable for 8.5 ton ductale AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete all as specified and as directed. Note:- Supply and charging Refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech 9 All as per item 8 here-in-before but for 3 to 5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos 10 Supply only of air filter set suitable for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech 11 All as per item 10 here-in-before but for 3 to 5 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos 12 Supply only of low / high pressure switch for8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech 13 All as per item 12 here-in-before but for 5 TR/3 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos 14 Taking out unserviceable sealed unit compressor from cassetee/ pillar type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and Supply and fixing new scroll compressor of capacity 3 ton including charging of refrigerant gas R-22 upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/CopelandNOTE : Supply and charging refrigerent gas will be measured and paid separately under relavent items 15 All as per item14 here-in-before but three phase compressor of capacity or4TR/4.25 TR suitable for 8.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland 16 All as per item 14here-in-before but three phase compressor of capacity 5 TR suitalbe for 5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland Note for serial item No 14 to 16:Supply and charging refrigerent gas will be measured and paid seperately under relavent items 17 Carrying out pressure leak test of 3 to 8.5 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :-Supply & charging of refrigerant gas R-22 will be measured and paid for separately 18 Supply only thermal relay 15 A to 30 Amps, 415 Volt, single phase suitable for pillar/ cassette/ductable type AC of 3 TR/5 TR/8.5 TR capacity as per samplecomplete all as specified and as directed. Make : LG /Hitech/Indo Asian/L&T/Tecumseh. 19 Supply only PCB (circuit plate) of out-door/indoor unit of 8.5 TR ductable split AC complete all as specified and as directed. 20 All as per item 19 here-in-before but for pillar /ductable/ casette / anytype AC 3.0 TR to 5.0 TR 21 Repair only PCB (circuit plate) of outdoor /indoor unit of 8.5 TR ductable split AC complete all as specified and as directed. 22 All as per item 21 here-in-before but for pillar /ductable/ casette / anytype AC 3.0 TR to 5.0 TR. 23 Supply only single phase preventor, 230 volt, 50 HZ, AC supply suitable for 3 to 8.5 TR AC as per sample complete all as specified and as directed. Make : L&T / Seimens / Hagger. 24 Supply only reverse cycle valve suitable for cassette/pillar type AC of capacity AC 3.0 Ton to 8.5 Ton as per sample complete all as specified and as directed. 25 Supply only indoor fan / blower motor for cooling coil/ condensing coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 3 TR to 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar. 26 Supply only outdoor fan / blower motor for cooling coil/ condensing coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 3 TR to 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar. 27 Supply only drain pump DC 12/24 volt or AC 230 for indoor unit, cassette typeAC of 3 TR to 4TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan. 28 Supply only drain pipe of PVC medium grade of 25mm with all accessories like elbow, socket, tees, bend, adhesive etc complete all as specified and as directed. 29 Supply only drain pipe of PVC flexible 15mm with all accessories like elbow, socket, tees, bend, adhesive etc complete all as specified and as directed. 30 Supply only complete wiring kit for indoor / outdoor panel of ductable AC of capacity 3 to 8.5 Ton complete all as specified and as directed. 31 Supply only starter 3 phase ,415V, 40A suitable for ductable AC of cap3 to 8.5 TR complete all as specified and as directed. Make: L&T/BCH/ABB 32 Disconnecting electric connection from defective blower/ fanmotor and taking out from unit capacity 3 to 8.5 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burntwinding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding as per existing gauge wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed. 33 Supply only AC contactor single phase 230 volt, 50 Hz, double pole, AC3 rating 25 Amp to 40 Amp, AC1 rating 45 Amps to 55 Amps complete all as specified and as directed. 34 Taking down of defective evaporator unit of 3TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately 35 Renewal condensing unit of Cassette type AC of capacity 3 TR capacityoutdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly. 36 Taking down of defective evaporator unit of 4TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately 37 Renewal condensing unit of Cassette type AC of capacity 4 TR capacityoutdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly. 38 Vertical three phase distribution board 12 way 440 volts having IP 43 protection with metal double door with provision for fixing of MCCBs as incomer and outgoing MCB TPN complete all as specified and directed and making new electrical connections with thimbles or other suitable arrangements including taking down existing unserviceable DB and making good surface with matching existing surfaces all as specified and directed. 39 MCB Triple pole & Neutral C curve 63 Amp 10 KA including taking down existing unserviceable MCB complete all as specified and directed 40 Renewal MCCB, four pole, 300 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed. 41 Renewal MCCB, four pole, 160 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed. 42 5/8” and 3/8” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and as directed.Note : 1 meter of 5/8 dia copper pipe, 1 meter of 3/8 dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose. 43 All as per item 42 here-in- before but size 1/2” and 1/4” dia,Note : 1 meter of 1/2 copper pipe, 1 meter of 1/4 dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose. 44 flair nut of 5/8 and 3/8 dia complete all as specified and as directed. 45 flair nut of 1/2 and 1/4 dia complete all as specified and as directed. 46 4 core copper wire size 6 sqmm PVC insulated 1100 volt grade complete all as specified and as directed. 47 3 core copper wire size 4 sqmm PVC insulated 1100 volt grade complete all as specified and as directed. 48 Supply & charging (Topping up) the ductable/ cassette type AC etc with refrigerant gas R-22 in required quantity for desired cooling complete all as specified and as directed.Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed. 49 Suction valve/ discharge valve suitable for 4.25, 3 & 5 TR compressor all as specified and as directed.Make:- BAP / TAK Cassel 50 Supply only remote control hand set for existing window type/ split type air conditioner of make LG/ Samsung/ Voltas/ Bluestar or as per existing and of cap 3 to 8.5 ton with required pencil cells complete all as specified and as directed. 51 Supply only any type of sensor suitable forAC of 3 TR to 8.5 TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan. 52 Dismantling at site for Repair and replace the defective parts to automatic phase corrector panel and reinstalled including S&F Contactor 415 v 300Amps cat pt no. MCE15SN3M7 and testing complete including making electric connection and all as specified and directed by Engr-in Charge.Make BCH or Equivalant 53 Coil 415 v 300 Amps cat part No.2-2412-M complete all as specified and directed. 54 Reley minilac 415 V cat part No.VSPD1415V complete all as specified and directed. 55 Magnetic connector 415 V, 25 amps to 63 amps suitable for AC 3 to 8.5 TR and all as specified and directed by Engr-in Charge 56 Condencing coil of out door unit suitable for AC 3 to 8.5 TR, fixed as in repair complete all as specified and directed. 57 Evaporator coil of in door unit suitable for AC 3 to 8.5 TR, fixed as in repair complete all as specified and directed. 58 Tray of thermocol suitable for drain of water of indooor unit suitable for AC 3 to 8.5 TR, complete all as specified and directed. 59 Supply only 2.5 to 10 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos. 60 Supply only 36 to 60 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos. 61 Supply only 40/60,80/100 to 100/120 Mfd starting capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Nov-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF 03 PHASE COOLING APPLIANCES INSTALLED IN VARIOUS UNITS AT CHANDIMANDIR
Sl. No. Item Description
1Attending the daily complaints pertaining toACs three phase at site which includes the following (i)Checking elect circuit, tightening of loose elect connection including internal circuit of plant and ensure the functioning of the plant. Note :- (i) Spare parts if any required shall be measured and paid separately as supply only. (ii)Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging, leak testing etc mentioned as S & F/ M & L (iii) Work against entire quantity shall be completed within set schedule to be decided by Engineer-in-charge. (iv) All the plants shall be handed over on daily basis through proper documentation. (v) The deployed tradesman shall have technical qualification in the field and necessary documentary proof shall be produced by the contractor. (vi) For non attendance of complaints within 24 Hrs, penal charges @Rs 1000 per complaint per day shall be charged. (vii) Thorough care/ protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning. (viii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost. (ix)Each service shall be measured and paid separately as each job. (x) The technician must have the minimum qualification of ITI in Refg& AC from Recognize institute of Govt Approved. (xi) Pin valve, PVC tape etc shall be part of the job at no extra cost. (xii)The platform ladder arrangement upto 20ft high or 40 ft high by steel structure platform will be provide by the Contractor at no extra cost
2Comprehensive maintenance of AC"s (Hot & Cold) of capacity 8.5 Ton ductable ACs of make LG,by disconnecting/ dismantling of indoor and outdoor unit at site and refixing the same after repair/renewal of the defective spare parts (spare parts where required to be replaced shall be measured and paid separetly as supply only). Servicing of the ducts, drain pipe, cooling coil, condensing coil and adjusting the duct slope for free flow of drain water, testing of the complete set of Hot/Cold at desired temperature complete all as specified and as directed. Note:- (i)Gas charging, spare parts shall be measured and paid for separately under respective items. (ii)The contractor shall provide only the experienced and qualified staff for handling the sensitive works. (iii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor,gas charging, leak testing. (iv)Work against entire quantity shall be completed within set schedule to be decided by Engineer-in-charge. (v) All the plants shall be handed over on daily basis through proper documentation. (vi) Penal charges @ Rs 1000 per plant per day shall be charged for not following the schedule. (vii) Thorough care/ protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning. (viii) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost. (ix)Each service shall be measured and paid separately as each job. (x) The Contractor to ensure and depute a technicien to the office for obtain complaint slip at 0900 hrs daily.
3All as per item 2 here-in-before but for 5.0 Ton ductable type AC. Make: Amtrex LG/ Danfoss/ Indofos/ Copeland
4All as per item 2 here-in-before but for 4 Ton cassette type / ductable type AC. Make: Amtrex LG/ Danfoss/ Indofos/ Copeland
5All as per item 2 here-in-before but for 3 TR cassette type / Pillar type AC. Make: LG/Hitachi
6Material for providing insulation on and around suction and discharge copper tube of size 1/2"" and 1/4"", 3/8" and 5/8" with 6 mm thick flexible thermocol heat resistance duly warpped with sticking tape and finally covered with flexible PVC conduit of 50mm dia complete all as specified and as directed.
7Supply only ofAC 4 Pole power contactor three phase of capacity 25 Amp to 40 Amp suitable for pillar type AC-3 TR/5TR/8.5R complete all as specified and as directed.
8Supply only liquid line drier filter suitable for 8.5 ton ductale AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete all as specified and as directed. Note:- Supply and charging Refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
9All as per item 8 here-in-before but for 3 to 5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
10Supply only of air filter set suitable for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
11All as per item 10 here-in-before but for 3 to 5 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos
12Supply only of low / high pressure switch for8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
13All as per item 12 here-in-before but for 5 TR/3 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos
14Taking out unserviceable sealed unit compressor from cassetee/ pillar type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and Supply and fixing new scroll compressor of capacity 3 ton including charging of refrigerant gas R-22 upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland NOTE : Supply and charging refrigerent gas will be measured and paid separately under relavent items
15All as per item14 here-in-before but three phase compressor of capacity or4TR/4.25 TR suitable for 8.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
16All as per item 14here-in-before but three phase compressor of capacity 5 TR suitalbe for 5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland Note for serial item No 14 to 16:Supply and charging refrigerent gas will be measured and paid seperately under relavent items
17Carrying out pressure leak test of 3 to 8.5 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :-Supply & charging of refrigerant gas R-22 will be measured and paid for separately
18Supply only thermal relay 15 A to 30 Amps, 415 Volt, single phase suitable for pillar/ cassette/ductable type AC of 3 TR/5 TR/8.5 TR capacity as per samplecomplete all as specified and as directed. Make : LG /Hitech/Indo Asian/L&T/Tecumseh.
19Supply only PCB (circuit plate) of out-door/indoor unit of 8.5 TR ductable split AC complete all as specified and as directed.
20All as per item 19 here-in-before but for pillar /ductable/ casette / anytype AC 3.0 TR to 5.0 TR
21Repair only PCB (circuit plate) of outdoor /indoor unit of 8.5 TR ductable split AC complete all as specified and as directed.
22All as per item 21 here-in-before but for pillar /ductable/ casette / anytype AC 3.0 TR to 5.0 TR.
23Supply only single phase preventor, 230 volt, 50 HZ, AC supply suitable for 3 to 8.5 TR AC as per sample complete all as specified and as directed. Make : L&T / Seimens / Hagger.
24Supply only reverse cycle valve suitable for cassette/pillar type AC of capacity AC 3.0 Ton to 8.5 Ton as per sample complete all as specified and as directed.
25Supply only indoor fan / blower motor for cooling coil/ condensing coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 3 TR to 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
26Supply only outdoor fan / blower motor for cooling coil/ condensing coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 3 TR to 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
27Supply only drain pump DC 12/24 volt or AC 230 for indoor unit, cassette typeAC of 3 TR to 4TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan.
28Supply only drain pipe of PVC medium grade of 25mm with all accessories like elbow, socket, tees, bend, adhesive etc complete all as specified and as directed.
29Supply only drain pipe of PVC flexible 15mm with all accessories like elbow, socket, tees, bend, adhesive etc complete all as specified and as directed.
30Supply only complete wiring kit for indoor / outdoor panel of ductable AC of capacity 3 to 8.5 Ton complete all as specified and as directed.
31Supply only starter 3 phase ,415V, 40A suitable for ductable AC of cap3 to 8.5 TR complete all as specified and as directed. Make: L&T/BCH/ABB
32Disconnecting electric connection from defective blower/ fanmotor and taking out from unit capacity 3 to 8.5 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burntwinding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding as per existing gauge wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
33Supply only AC contactor single phase 230 volt, 50 Hz, double pole, AC3 rating 25 Amp to 40 Amp, AC1 rating 45 Amps to 55 Amps complete all as specified and as directed.
34Taking down of defective evaporator unit of 3TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
35Renewal condensing unit of Cassette type AC of capacity 3 TR capacityoutdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly.
36Taking down of defective evaporator unit of 4TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
37Renewal condensing unit of Cassette type AC of capacity 4 TR capacityoutdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly.
38Vertical three phase distribution board 12 way 440 volts having IP 43 protection with metal double door with provision for fixing of MCCB"s as incomer and outgoing MCB TPN complete all as specified and directed and making new electrical connections with thimbles or other suitable arrangements including taking down existing unserviceable DB and making good surface with matching existing surfaces all as specified and directed.
39MCB Triple pole & Neutral C curve 63 Amp 10 KA including taking down existing unserviceable MCB complete all as specified and directed
40Renewal MCCB, four pole, 300 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed.
41Renewal MCCB, four pole, 160 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed.
425/8” and 3/8” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and as directed. Note : 1 meter of 5/8" dia copper pipe, 1 meter of 3/8" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
43All as per item 42 here-in- before but size 1/2” and 1/4” dia, Note : 1 meter of 1/2" copper pipe, 1 meter of 1/4" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
44flair nut of 5/8" and 3/8" dia complete all as specified and as directed.
45flair nut of 1/2" and 1/4" dia complete all as specified and as directed.
464 core copper wire size 6 sqmm PVC insulated 1100 volt grade complete all as specified and as directed.
473 core copper wire size 4 sqmm PVC insulated 1100 volt grade complete all as specified and as directed.
48Supply & charging (Topping up) the ductable/ cassette type AC etc with refrigerant gas R-22 in required quantity for desired cooling complete all as specified and as directed. Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed.
49Suction valve/ discharge valve suitable for 4.25, 3 & 5 TR compressor all as specified and as directed.Make:- BAP / TAK Cassel
50Supply only remote control hand set for existing window type/ split type air conditioner of make LG/ Samsung/ Voltas/ Bluestar or as per existing and of cap 3 to 8.5 ton with required pencil cells complete all as specified and as directed.
51Supply only any type of sensor suitable forAC of 3 TR to 8.5 TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan.
52Dismantling at site for Repair and replace the defective parts to automatic phase corrector panel and reinstalled including S&F Contactor 415 v 300Amps cat pt no. MCE15SN3M7 and testing complete including making electric connection and all as specified and directed by Engr-in Charge.Make BCH or Equivalant
53Coil 415 v 300 Amps cat part No.2-2412-M complete all as specified and directed.
54Reley minilac 415 V cat part No.VSPD1415V complete all as specified and directed.
55Magnetic connector 415 V, 25 amps to 63 amps suitable for AC 3 to 8.5 TR and all as specified and directed by Engr-in Charge
56Condencing coil of out door unit suitable for AC 3 to 8.5 TR, fixed as in repair complete all as specified and directed.
57Evaporator coil of in door unit suitable for AC 3 to 8.5 TR, fixed as in repair complete all as specified and directed.
58Tray of thermocol suitable for drain of water of indooor unit suitable for AC 3 to 8.5 TR, complete all as specified and directed.
59Supply only 2.5 to 10 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
60Supply only 36 to 60 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
61Supply only 40/60,80/100 to 100/120 Mfd starting capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.