Tender For Additional /Alternator To Washroom / Toilets And Allied Works In Barrack No. 04 At Ota Chennai Under Ge Stm., Chennai-Tamil Nadu

Military Engineer Services-MES has published Tender For Additional /Alternator To Washroom / Toilets And Allied Works In Barrack No. 04 At Ota Chennai Under Ge Stm.. Submission Date for this Tender is 15-12-2023. Toilet Bathroom Tenders in Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40684320
Corrigendum : Tender For Additional /Alternator To Washroom / Toilets And Allied Works In Barrack No. 04 At Ota Chennai Under Ge Stm.
Open Tender
Indian
Tamil Nadu
Chennai
15-12-2023

Tender Details

Tender For Additional / Alternator To Washroom / Toilets And Allied Works In Barrack No. 04 At Ota Chennai Under Ge Stm.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 85000.0 /-
Tender Value
INR 42.50 Lakhs /-

BOQ Items

Name of Work:ADDN / ALTN TO WASHROOM / TOILETS AND ALLIED WORKS IN BARRACK NO.4 AT OTA CHENNAI UNDER GE STM
Sl. No. Item Description
1Supply and fix in repair vitreous china wash down water closet (pedestal pattern), white, of style and pattern as existing, complete with and including plastic seat cover white coloured all as specified and directed.
2Supply and fix in repairs chromium plated cascade health faucet with minimum 1200mm long pipe of fancy type all as specified and directed.
3S&F in repairs PVC, syphonic action type, flushing cistern, low level, white, 10 lirs, with inlet ball valve, float, handle and flush pipe incl. brackets including 32 mm dia flush pipe
4S&F in repairs Bib taps 15mm bore cast copper alloy with crutch or butter fly handle chromium plated screwed down for iron pipe or for brass ferrule fixed.
5S&F in repair stop valves15mm bore chromium plated with long shank and cup (Concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed
6S&F Pillar taps 15mm, cast copper alloy with capstan heads, CP fancy type, screwed down high pressure with long screwed shanks and flynuts screwed for iron pipe and fixed.
7S&F in repair CP brass shower rose 125mm size suitable for 15mm bore pipe complete all as specified.
8S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long.
9S&F toilet paper holder with flat recessed type stainless steel complete all as spcified and directed.
10S&F Vitreous China oval shaped wash basin counter type, white, of size 550 x 400mm embedded on marble platforms including cutting for and pinning in ends of brackets or erecting stand brackets, 32 mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms /40mm-60 gms & waste pipe including taking down of old wash basin
11S&F in repairs 15mm bore PVC connection of 600mm long with PTMT nuts
12S&F in repairs 450 x 600mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers
13S&F in repairs Brass chromium plated Tubular towel rail, 20mm dia, D type, 30cm long between flanges
14Supply and fix in repairs Vitreous China Urinal, Half stall type coloured complete fixing with suitable fixing arrangements to wall with and including CP urinal spreader, CP domed waste coupling and waste pipe complete all as specified and directed.
15Demolition and breaking up drain pipes of any type set in cement mortar
16S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor.
17S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed on walls
18S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor.
19S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed on walls.
20S&F 110 mm bore PVC (SWR) bend
21S&F 75 mm dia PVC (SWR) floor trap with grating including jointing to solvent cement waste pipe.
22S&F PVC (SWR) Gully trap of size 125 / 110mm setting and jointing withsolvent cement.
23S&F PVC (SWR) vent cowl of size 110 mm
24S&F PVC (SWR) junction single, (Single T) equal or unequal for 110mm bore pipe with access door
25S&F PVC (SWR) junction single, (Single T) equal or unequal for 75mm bore pipe with access door
26S&F PVC (SWR) bend 75mm bore.
27S&F PTMT Grating doom 100mm dia of Minimum weight - 25gms
28S&F stack clamps made out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for fixing bore of 110mm pipe
29S&F in repairs triple layered rotational moulded polyethylene water storage tanks of capacity 2000 litres (cylindrical, vertical with closed top) hoisted and fixed in position all as specified and including taking down old tanks
30S&F in repairs triple layered rotational moulded polyethylene water storage tanks of capacity 1000 litres (cylindrical, vertical with closed top) hoisted and fixed in position all as specified and including taking down old tanks
31S&F Ball valves 25mm high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms)
32S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
33S&F in repairs 40mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
34Taking up or taking down steel/ iron tube of 20mm bore and connections including cleaning for refixing or removal to store complete all as specified.
35Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/ floors complete all as specified.
36Taking up or taking down steel/ iron tube of 25mm bore and connections including cleaning for refixing or removal to store complete all as specified.
37Supplying and laying of 25mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/ floors complete all as specified.
38Taking up or taking down steel/ iron tube of 50mm bore and connections including cleaning for refixing or removal to store complete all as specified.
39Supplying and laying of 50mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/ floors complete all as specified.
40Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness below or above ground level.
41Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for
42Demolition of brick work built in cement mortar including all precast concrete articles.
43Dismantling of floor/ wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises.
44M&L for providing 25mm thick plain cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate
45M&L for Non skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in coloured tiles over and including cement screed 15mm thick in CM 1:4all as specified and directed
46M&L for glazed ceramic coloured tiles, 350x250x7mm or 450x350x7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including cement plaster 10mm thick in CM 1:3 all as specifiedand directed
47M&L for brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4
48M&L for providing lintels upto 1.5m clear span on half brick partition wall with reinforced cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate including necessary form work. Note:- Reinforcement bars shall be measured and paid seperately.
49S&F TMT steel bars 10mm dia and over, cut to length bent to shape required as in reinforcement to lintels all as specified and as directed
50All as per item No.49 above but 6mm to 8mm dia
51All as per item No.49 above but 5mm dia and over upto and including 10mm dia in stirrups.
52M&L for rendering 10mm thick on fair faces of concrete surfaces finishedeven and smooth without using extra cement in CM 1:4 with liquid water proofing chemical as per manufacturer"s instructions on sunken slab of toilets complete all as specified and as directed. Note: Liquid water proofing chemical measured and paid separately
53Preparing the surface thoroughly to remove all loose particles /dust particles and applying blown grade bitumen VG 10 @ 1.2 kg/Sqm confirming to IS 702 and apply a coat of bitumen primer @ 0.40 ltrs/sqm followed by APP membrane reinforced with polyester non woven fabric 3 mm thick weighing not less than 3.8 kg/sqm laid on primed surface by forced torch application followed by a finishing coat of solar reflective aluminium painting @ 0.10 kg /sqm complete all as specified and as directed. Note: The work shall be carried out by authorized applicators of manufacturers
54M&L for plain cement concrete 1:5:10 type E-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete
55M&L for marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and the like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble makrana white over 15mm thick screed bed in CM 1:4
56M&L for reinforced cement concrete 1:2:4 type B-1, using 20mm graded stone aggregates as in slabs supported on walls Note:- Reinforcement bars shall be measured and paid seperately.
57Use and waste of formwork to soffits of suspended slabs for fair finished surfaces.
58S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, in opening as per specification and as directed at site. Note:-i) Existing wall edges will have to be finished properly in cement plaster 1:4 including fixing of 6 Nos wooden plugs for catch door frame size not exc 17Sqcm average sectional areas and 100mm long. ii) Frame will have to be fixed to the wooden plugs inserted in wall using 6 Nos of 100mm long MS screw, 3 each on either side. iii) PCC strip of section 5*5mm will have to be created at bottom incl. smooth finish in each door opening.
59S&F Factory Made Solid Panel PVC Door shutter 30mm thick (Style) consisting of frame made out of M S tubes for top & bottom rails, M S frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail and jointed together with solvent cement, supplying & fixing in frame at site as per specification and as per SSR Part I
60M&L for second class hardwood plain solid straight chowkats and frames, wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints.
61M&L for factory made 35mm thick second class hardwood plain framed panelled door shutter two panels, with lock rail and panel of 9mm BWP, commercial ply or 12mm veneered particle board with commercial face veneering on both faces complete all as specified and directed.
62S&F anodised aluminium (minimum 50 micron) frame for windows, ventilators, partitions and grills/ guard bars etc with one or more rebates including joining cleat for fixing etc., complete all as specified.
63S&F anodised aluminium window and ventilator shutters, side hung type (minimum 50 micron) without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as 150mm long peg stays(1 No), 100mm long hinges type B-21(2 No), suitable handle (1 No), etc., complete all as specified and directed.
64S&F Anodised aluminium window and ventilator shutters, fixedtype (min 50 micron) without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and directed.
65S&F Anodised aluminium deco grill of size of mesh not exc 75mm x 75mm, thickness of 6mm, decorative type and fixed with suitable aluminium section fixed to aluminium frame of windows / ventilators complete all as spcd and as directed.
66Cutting holes in brick walls exc half brick n.exc one brick, built in cement mortar for inserting hold fast and making good dismantled portion in cement concrete 1:2:4 type B-1 as required
67S&F mild steel FI of size 25 x 3mm holdfast 300mm long
68Taking down chowkats or frames with shutters (without taking off shutters from frames) exc. 1.5 Sqm but n. exc 4 Sqm each including making good disturbed surfaces
69All as per item No.68 above but n.exc 1.5 Sqm each.
70S&F 4.0mm thick frosted Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane and fixed to aluminium frames using rubber packing
71S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified.
72S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy and fixed.
73S&F Butt hinges 100mm, mild steel hinges fixed with stainless steel screw with frame
74S&F Butt hinges 75mm, stainless steel type, anodised and fixed
75S&F Aluminium anodised barrel tower bolts of extruded section 200mm size
76S&F Aluminium anodised barrel tower bolts of extruded section 150 mm size
77S&F Extruded aluminium alloy handles, fabricated type, anodised 150 mm long
78S&F Extruded aluminium alloy handles, fabricated type, anodised 125 mm long
79M&L for preparing new wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pinkprimer, complete all as specified and directed.
80M&L for brick work with old size fly ash bricks straight or curved on plan and 6 metre mean radius built in CM 1:6 all as specified and directed
81M&L for 150mm dia reinforced concrete pipes NP-3, laid and jointed complete with collars.
82M&L for plain cement concrete 1:3:6 type C-2 as in bed to 150mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested.
83Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc
84M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement on internal wall surfaces.
85M&L for rendering 10mm thick in CM 1: 6 as under layer and 5mm thick in CM 1:4 mixed with water proofing compound as finishing layer to external wall surfaces and finishing the surface even and smooth including taking down existing cement plaster if necessary.
86Supply only liquid water proofing chemical
87Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer to internal wall surfaces complete all as specified and as directed.
88Preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer all as specified and as directed.
89Preparation of old decorated ceiling surfaces including necessary scaffolding and applying one coat of white wash including filling the cracks/ depressions using chalk whitening wherever required all as specified
90Complete removal of existing treatment on walls and applying two coats of exterior weather proof paint over a coat of weather proof primer to all external wall surfaces complete all as specified and as directed.
91Dismantling of cast iron or reinforced concrete 150mm dia drain pipes, jointed in cement mortar and taking out of trenches if required
92Rounding to edges of Granite/stone slabs one edge, such as in steps, cooking platform, and other similar situations.
93Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit all as directed.
94M&L for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit accessories concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket / electronics fan regulator / telephone socket, including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/ fan point controlled by one way switch complete including cutting chases, pinning in, making good tofacing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 Cm girth all as specified and as directed.
95(a)One light point controlled by one switch.
96(b)One 3 pin 5 amps switch socket on independent board.
97(c)One 3 pin 5 amps switch socket on same board along with other switches.
98(d)One exhaust point controlled by one switch
99All as per item No.94 above but with 4 sqmm copper conductor cable with 2.5 sqmm PVC copper conductor cable as earth continuity conductor for one socket outlet 15/16 amps controlled by one switch15/16 Amps on independent board all as specified and as directed.
100M&L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 6 sqmm including one run of 6 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsvall as specified and directed.
101Supply and fix Wall mountedLED 40W Batten Basic all purpose surface and wall mounted LED batten with Aluminium housing & Integrated electronic driver all as specified and as directed.
102Supply and fixing wall mounted LED batten, Extruded aluminium housingprovided efficient heat dissipation with polycarbonate diffuser with integrated electronic driver high efficacy Short circuit & voltage cut off protection, wide operating voltage range of 140V to 270V wide, lumen output of 1050,10W including lamp with complete all as specified and as directed.
103Supply and fix MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link, 8 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
104S&F MCB SPN230 volts, 40 amps "C" Curve 10 kA Capacity including taking down Old MCB completeall as directed.
105S&F MCB SP 230 volts, 40amps "C" Curve 10 kA Capacity including taking down Old MCB completeall as directed.
106S&F Ceiling rose surface bakelite 65mm x 50 mm two to three terminals all as directed.
107S&F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed
108S&F Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and directed
109S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed
110S&F Modular socket 6 A/ 16 A -2/3 pin combined 2 module complete all as specified and directed
111Disconnection and taking down old unsv exhaust fan and deposite the same to MES store safely and Supply and fixing, ventilating (HEAVY DUTY)fans of 300mm sweep, 1400 RPM Metallic Body, Double Ball bearing single phase including necessary addn/ altn for fixing of fans including making holes wall/ windows all as per site requirement and making good the disturbed surfaces, matching with the existing wall all as specified and directed.