Tender For Renovation Of Ped, Gte Division And Administrative Block(E-Ii Section) At Crri, New Delhi, Delhi-Delhi

Council Of Scientific And Industrial Research-CSIR has published Tender For Renovation Of Ped, Gte Division And Administrative Block(E-Ii Section) At Crri, New Delhi. Submission Date for this Tender is 23-11-2023. Office Furniture Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

40680596
Tender For Renovation Of Ped, Gte Division And Administrative Block(E-Ii Section) At Crri, New Delhi
Open Tender
Indian
Delhi
Delhi
23-11-2023

Tender Details

Renovation Of Ped, Gte Division And Administrative Block ( E-Ii Section ) At Crri, New Delhi Scope Of Work Includes Some False Ceiling, Flooring Tiles, Wall Tiles, Wooden Doors, Wooden Cupboards, Almirahs, Zebra Blinds, Conference Table, Polished Granite Flooring, Fume Chamber, Aluminium Partition, Painting, Point - Socket Wiring And Other Works

Key Value

Document Fees
INR 1000 /-
EMD
INR 193000.0 /-
Tender Value
INR 96.17 Lakhs /-

BOQ Items

Name of Work: Renovation of PED, GTE Division and Administrative Block (E-II Section) at CRRI, New Delhi
Sl. No. Item Description
1Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
2Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
3Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead.. Of area 3 sq. metres and below
4Dismantling tile work in floor and roofs laid in cement mortor including stacking material within 50 meters lead. for thickness of tiles 10mm to 25 mm.
5Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 meters lead as per direction of Engineer - in - charge. Nominal Concrete 1:3:6 or richer mix.
6Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer - in - charge.
7Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
8Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
9Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
10Supplying and filling in plinth with sand under floors, including watering , ramming , consolidating and dressing complete.
11Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar1:6(1 cement : 6 coarsesand).
12Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar1:6(1 cement : 6 coarsesand) .
13Half brick masonry with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 ( 1 cement : 4 coarse sand)
14Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
1512 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
1615 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement : 6 coarse sand)
17Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground, all completed as per direction of Engineering in Charge. with cement mortar 1:4(1 Cement :4 Coarse sand)
18Providing and laying in position cementconcrete of specified grade excluding the cost of centering and shuttring - All work up to plinth level :1:4:8( 1 Cement: 4 coarse sand (Zone-III) derived from natural sources :8 graded stone aggregate 40 mm nominal size derived from natural sources).
19Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
20Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 mm to 40 mm nominal bore
21Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc
22Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ)
23Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls, Under 20 cm wide
24Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
25Reinforced cement concrete work in beams, suspended floors , roofs having slope up to 15° landing, balconies, shelves, chajjas lintels, bands plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
26Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black,cherry/Ruby red. Area of slab upto 0.50 sqm and over 0.50 sqm.
27Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work.
28Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
29Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade
30Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)
31Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval,including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
32Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints.(Payment for grounting of joints to be made separately). Size of Tile 600x600 mm
33Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
34Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Kiln seasoned and chemically treated hollock wood
35Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.Kiln seasoned and chemically treated hollock wood
36Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
37Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :100x10 mm
38Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm
39Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with nuts and screws etc. complete 300x16 mm
40Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
41Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 35 kg to 80 kg and door width from 701mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
42Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
43Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extructed built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285,fixed with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, striaght, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panalling,C.P brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer in charge.(Glazing ,panelling and dash fasteners to be paid for seperately) : For shutters of doors,windows & ventiliatiors including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for seperately).Powder coated aluminium (minimum thickness of powder coating 50 micron).
44Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extructed built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285,fixed with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, striaght, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panalling,C.P brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer in charge.(Glazing ,panelling and dash fasteners to be paid for seperately)For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron.)
45Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm
46Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge. Powder coated minimum thickness 50 micron aluminium
47Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
48Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
49Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P.brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre - laminated particle board with decorative lamination on both sides.
50Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
52Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @0.75 ltr /10 sqm
53White washing with lime to give an even shade :Old work (two or more coats)
54Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes
55Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes.
56Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 40 mm nominal dia Pipes.
57Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
58Providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. 1.0 mm thick.
59Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : Decorative veneer facings of approved manufacture
60French spirit polishing : Two or more coats on new works including a coat of wood filler
61Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50 mm (base and height)
62Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade I as per IS : 1068 and fixing with necessary screws etc., complete. Overall width 35 mm
63Providing and fixing bright finished brass handles with screws etc. complete: 75 mm
64Painting with oil type wood preservative of approved brand and manufacture : New work (two or more coats)
65Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type)
66Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.75 mm
67Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineerin- charge.
68Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
69Providing and fixing fly proof stainless steel grade 304 wire gauge, towindows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading
70Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
71Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
72Providing and fixing precoated glavanised iron profile sheets (size shape and pitch of corrugation as approved by engineer -in - charge ) 0.50 mm (+0.05 % ) total coated thickness with zink coated 120 gram per sqmts as per IS 277 , in 240 mpasteel greade 5-7 micron epoxy primer on both of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer -in - charge . The sheet shall be fixed using self driling /self tapping screw of size (5.5X55 mm ) with EPDM seal , complete upto any pitch in horizantal / vertical or curved surface, excluding the cost of purlins rafters and trusess and including cutting to size and shape wherever required
73Providing and fixing UV stabilished fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated "J" or "L" hooks, bolts & nuts 8 mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins,rafters,trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabilliser in resin system under approximately 2400 psi and hot cured.They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 10192 and IS 12866. The sheets shall be opaque or translucent,clear or pigmented,textured or smooth as specified. 2mm thick flat.
74Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
75Dismantling wooden cupboards including supporting members and stacking within CRRI campus as directed by the Engineer-in-charge. (Size up to 1.00mX 2.00m depth 0.43 mtr)
76Providing and fixing notice board of Core board material /Soft Board used for pin up the papers etc. of required size or shape with front of Board covered with standard quality display cloth of requiredcolour, around aluminium beading, hangers etc.Complete as directed by Engineer-in- charge.
77Providing and Fixingof Stainless steel Name plate 1 mm thickof required size or shape with lettering engraved on sheet of required size of fonts, colour in the engraved portion with nails screw etc. complete as approved by Engineer-in-charge
78P/F granite double strip/ nosing above wall paneling including chase cutting moulding fixing with cement mortor complete in all respect as directed by Eneineer - In - charge
79Providing and fixing aluminium handles parrot type/cockspur, ISI marked, powder coated required colour or shade, with necessary screws etc. complete :
80Providing and fixing glazing in aluminium door,window,ventilator and shutters and partitions etc. with PVC/neroprence gasket etc. complete as per the architectural drawings and the directions of Engineer in Charge. (Cost of aluminium snap beading shall be paid in basic item) With Float glass panes of 5 mm thickness.
81P/F150 mm nominal bore PVC pipeapproved quality (Prakash or equivalent make) on wall with elbow, tee,bend, brackets, screws etc complete as directed by the Engineer-in-charge.
82Providing & Fixing horizontal Zebra fabric blinds of approved quality, colour & shadesI/c rod,chain,pulley,brackets, screws etc.Complete as directed by the Engineer-in-charge.
83Providing/Making/Fixing table/Counter along with side storage unit consisting of the items 25 mm block board with 5mm thick second class teak wood lipping on all edges polishing, etc in the frame work as specified above and directed by Engineer - in - charge
84Providing/Making/Fixing table/Counter along with side storage unitconsisting of theitems19 mm block board with second class teak wood lipping on all edges polishing, etc in the frame work as specified above and directed by engineer - in - charge
85Providing/Making/Fixing table/Counter along with side storage unitconsisting of theitems18 mm commercial plywoodwith second class teak wood lipping on all edges polishing, etc in the frame work as specified above and directed by engineer - in - charge
86Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters i/c P/F 5mm thick IInd.class teak wood lipping and 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
87Providing/Fixing Flexible Bendable Celing Curtain Track, Curved Ceiling Track for Curtains, Room Divider Ceiling Track Rail Systemfixing by driling hole in surface specified distanceuse rawal plug screw hanger ties and brackets etc as required complete in all respect as directed by engineer - in - charge
88Providing/Fixing 1 mm thick PVC Transparentstrip/ Ac Curtain upto hight 8.5 ftas required complete in all respect asdirected by engineer - in - charge
89P/L Cement mortar1: 4 ( 1 cement 4 coarse sand) for levelling the floor surface, if required.complete in all respect asdirected by engineer - in - charge
90Providing/Fixing 12 mm commercial ply in the frame work with screws etc. Complete as directed by Engineer - in - charge.
91Providing/Supplying and fixing CONFERENCE ROOM Table (Meeting Table) with the following Specifications: -The table is to be supplied in completely knock down conditions for assembly at site. The table top shall be 25 mm thick pre-laminated twin board of E-1-P2 grade with approved shade confirming to IS 12823:1990 and the edge banded witch matching 2 mm thick PVC lipping. Access panels provided with soft closing hinges. The Under structure consist of mixture of 25mm and 18mm prelaminated twin board of E1-p2 grade of approved shade conforming to IS 12823:1990 the edge banded with matching 2 mm thick PVC lipping. Anodised aluminium alloy 63600-Wp profile is added at bottom edge for improving the aesthetics. The table connections have to be made in such a way that no gaps should be seen in between the tables. Conference Table 14 Seater -1 no (Size 4200 mm x 1500 mm)Make: - Like Godrej Make Note: - (i) Only the make mentionedbe quoted for and used for .(ii) Any other make to be supplied in the works the same shall be got approved from the Engineer-in –charge.
92Electrical Works:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
93Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
94Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
95Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
96Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
97Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
98Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
99Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
100Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
101Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
102Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
103Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
104Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)
105Supply and installation of 2"x2" 36 Watt Ultra modern Slim recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling on the existing false ceilingand connections as required. Model-VENUSNEO2X2PLR36WLED865ST of Havells or equiv. Model of Crompton or Philips
106Supply, Installation, Testing and Commissioning of 4 way ETPN (IP43 protection) Metal door MCB distribution board with Suitable cable end box andprovision for phase bus-bars, nutral bars with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnecting wire set, cable ties and circuit identification lables with provision of 4 pole MCB as incomer and SP MCBs as outgoings including painting,earthing, connection, etc as required. Incomer - 63 Amps, FP MCB, C- curve, (Icu-10kA)- 1No. Outgoing- 10-32 Amp SP MCB(10kA), C- Curve - 12 Nos. Legrand or equiv. Model of L & T of Havells.
107Supply, Installation, Testing and Commissioning of 8 way VTPN (IP43 protection) Metal door MCB distribution board with suitable cable end box, providing with three phase Outgoing with provision for MCCB as incomer with insulated vertical phase bus-bars, neutral bars with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnecting wire set, cable ties and circuit identification lables, Spreder links and phase barriers with provision of 4 pole MCCBas incomer and TP MCBs & SP as outgoings including, painting, earthing, connection etc as required. Incomer - DRX type ,FP MCCB, Thermal release range 125 Amp,(Icu-36kA)- 1No. Outgoing- 63 Amp TP MCB(10kA) - 2 Nos., 32 Amp TP MCB(10kA)-02 Nos. 10-32 A SP MCB (10kA)-12 Nos. Model 5077 59 of Legrand or equiv. model of L & Tor Havells.
108Supply, Installation, Testing and Commissioning of 8 way VTPN (IP43 protection) Metal door MCB distribution board with suitable cable end box, providing with three phase Outgoing with provision for MCCB as incomer with insulated vertical phase bus-bars, neutral bars with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnecting wire set, cable ties and circuit identification lables, Spreder links and phase barriers with provision of 4 pole MCCBas incomer and TP MCBs & SP as outgoings includingpainting, earthing, connection etc as required. Incomer - DRX type ,FP MCCB, Thermal release range 125 Amp,(Icu-36kA)- 1No. Outgoing-10-32 A SP MCB (10kA)-24 Nos. Model 5077 59 of Legrand or equiv. model of L & Tor Havells.
109Supply of 1200 mm sweep, 230 Volt, decorative, 5 star energy efficient ceiling fan with all accessories. ENTICER BLDC of Havells or equiv. model of Orient/Usha/Bajaj
110Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
111Supply and installation of recess mounted 3 watt LED Spot Light, ideal for false ceiling with all accessories e.g. fixing clamps, suitable Installation frame, including cutting of holes in the false ceiling all complete as required.
112Shifting of 4 way 3 Phase ETPN DB from its existing position to new location including disconnection of old cilrcuit and cutting of wall and making the wall good as required .
113Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
114Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable
115Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.3 run of cable
116Supplying and fixing RJ 45 Computer (LAN)modular socket on the existing modular plate & switch box including connections etc. as required
117Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
118Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
119Supply, Installation, Testing and Commissioning of 4 way Submain Distribution Board (SMDB) (IP43 protection) providing with three phase Outgoing with provision for MCCB as incomer and MCCBas outgoing having single phase ammeter, voltmeter with selector switch and indicating lamps, bottom cabling box, side cabling box and corner boxes, both sides spreder links and phase barriers complete in all respect as required. Mounting of SMBD should be on existing wall with suitable fastner, nut-bolt/clamp etc as required. Incomer- 3 Pole MCCB, 250 Amp Thermal release range, Icu-36KA- 01 No., Outgoings- 3 Pole MCCB, 100 Amp,Thermal release range, Icu-36KA- 04 Nos., Meterig- Single Phase Ammeter (96X96)- 03 Nos., Single phase Voltmeter- 01 No. (96X96) with selector switch and indicating lamp, Bottom Cabling box-01 No., Side Cabling box-02 Nos.(Left and right side cable box 01 each), Corner Box-04 Nos., Make- L&T/Havells/Schneider or equiv.
120Supply, Installation, Testing and Commissioning of 12 way IP43 Metal Door SPN DBwith Neutral bar, Earth bar, cable ties, fully shrouded Neutral bars, pre-fitted masking sheet suitable for Flush Mounting with DP MCB as Incomer and SP MCB as Outgoing including painting, earth connection etc as required. Incomer- 63 Amp DP MCB, C-Curve-01 No., Outgoing- 10-32 Amp MCB-10 Nos., Legrand/Havells/L&T or Equiv.
121Supply and installation of 15 Watt Sleek recessed mounting down light pressure die cast aluminium in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic driver in the false ceiling including cutting of false ceiling and making the surface good complete ae required. Model-EDGEPRONEORDDLR15WLED865S of Havells or equiv. Model of Crompton or Philips. Dimension required- Cutout Size- 155mm, height- 17.5mm
122Supply of1.1 KV grade, XLPE/ PVC insulated, PVC seathed,Aluminium conductor armouredpower cables conforming to IS 7098 ( Part - 1) / IS 1554 ( Part - 1) and ISI markedof size 3.5CX150 sqmm. Make-Havells/Polycab/Gloster .
123Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm (50mm)
124Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 160 mm dia (OD-160 mm & ID-135 mm nominal)
125Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
126Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
127Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
128Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm)
129Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm)
130Supply and fixing 1 Module 5/6 Amp Modular switches in the existing Modular Switch board including connections as required.
131Dismanting of TPN DB/ Old Electric Panel having three sections of MCB Enclosure including disconnection ofexisting circuit and reconnections of existing circuit to newDB along with cutting of angles and finishing of wall, plastering, paining etc. as required
132Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
133Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
134Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
135Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
136Fire Alarm Works: Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
137Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
138Supplying, installation, testing & commissioning of manual call boxesof ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
139Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
140Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone interconnections as required.covered, complete with all connections, 10 -Zone
141Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail