| 1 | Excavation in trenchesn. exc 1.5 m width and not exc 1.5 mtr in depth for laying/taking out of pipe in soft/loose soil, complete all as specified anddirected. |
| 2 | Returning/filling in trenches including spreading leveling, watering and well ramming in layer not exc 25 cm thick, complete all as specified anddirected. |
| 3 | Removal of excavated surplus soil n.exc 50 m and depositing where directed at level n exc 1.5 m above the starting point, complete all as specified anddirected. |
| 4 | Supply & fixing DOL Starter 415 V, 3 Phase upto 10 HP complete all as specified and as directed. |
| 5 | Supply & fixing 350mm size Sluice Valve IS 5312 complete all as specified and as directed. |
| 6 | Taking up or down steel tubing and connections including cleaning for refixing or remove to MES store of following sizes, complete all as specified anddirected.( Note earth works measured and paidsepareately )(a) 15 MM bore |
| 7 | (b) 20 MM bore |
| 8 | (c) 25 MM bore |
| 9 | (d) 40 MM bore |
| 10 | (e) 50 MM bore |
| 11 | Refixing old GI tubing with necessary connections in old or new positions (laid in Trenches, walls, ceiling, floors etc) with necessary requiredincluding cleaning new fittings as per SSR Part -1 following of sizes complete all as directed.(a) 15 MM bore |
| 12 | (b) 20 MM bore |
| 13 | (c) 25 MM bore |
| 14 | (d) 40 MM bore |
| 15 | (e) 50 MM bore |
| 16 | Supply & Fixing in repair G.Itubes med grade Galvanized with necessary fittings and clamps as per SSR Part -1 laid in trenches /wall/floors concealed or open execution as directed. (a) 15 MM bore |
| 17 | (b) 20 MM bore |
| 18 | (c) 25 MM bore |
| 19 | (d) 40 MM bore |
| 20 | (e) 50 MM bore |
| 21 | Supply and fix in repair stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe with unions and fixed complete with suitable size of fittings like unions, long screw with check nut for iron pipe incl taking down existing stop valve complete all as directed at site of following sizes.(a) 15 MM bore |
| 22 | (b) 20 MM bore |
| 23 | (c) 25 MM bore |
| 24 | S&Fin repair gun metal globe or gate valve with iron wheel head, screwed both ends with union,long screw with check nutfor iron pipe incl taking down existing gate valve complete all as directed at site of followingsizes .(a) 15 MM bore |
| 25 | (b) 20 MM bore |
| 26 | (c) 25 MM bore |
| 27 | (d) 40 MM Bore |
| 28 | (e) 50 MM Bore |
| 29 | Taking up cast iron water mains including all fittings with spigot and socket ends and lead joint including burning out lead joint and recovering lead of CI pipe of following sizes:-( Note earth works measured and paidsepareately )(a)80 MM Bore |
| 30 | (b)100 MM Bore |
| 31 | (c)150 MM Bore |
| 32 | (c)200 MM Bore |
| 33 | Refixing of castiron pipes with socket and spigot end in trenches with necessary fittings in any lengthincludingcleaning of following sizes complete. (Excavation and earth work will be measured & paid separately).(a) 80 MM bore |
| 34 | (b) 100 MM bore |
| 35 | (c) 150 MM bore |
| 36 | (d) 200 MM bore |
| 37 | S&FDuctile Iron pipe with spigot and socket endsclass k-7suitable for Tyton joint in any length laid in trenches of following size (a)80 MM bore |
| 38 | (b) 100 mm bore |
| 39 | (c)150 mm bore |
| 40 | (d)200 mm bore |
| 41 | Material and labour in repair for run lead joints of CI pipes of following sizes complete.:-(a)80 mm bore |
| 42 | (b) 100 mm bore |
| 43 | (c) 150 mm bore |
| 44 | (d) 200 mm bore |
| 45 | M&L in repair for Rubber gasket (Tyton) joint of following sizes.(a) 80 mm bore |
| 46 | (b)100 mm bore |
| 47 | (c)150mm bore |
| 48 | (d)200 mm bore |
| 49 | (e)250 mm bore |
| 50 | M&L drilling and tapping cast iron water mains in position for branch connections of following internal dia size complete all as directed at site.(a) 15 mm bore |
| 51 | S&F in repair DI Bends( any type radius and angles) tapers any type(straight bend increasing decreasing or double socket etc) tee pieces single branch Y junction, doublebranches cross ( all sockets or socket and spigot) collars caps and plugs suitable for socket and spigot type of any bore. |
| 52 | S&F in repair bib taps cast copper alloy with crutch or butter fly handle screwed down, screwed for iron pipe as per SSR pt -1 of size15 mm bore complete all as directed at site. |
| 53 | Cutting the existing leakage/broken CI pipe in position for the following pipes and taking out the broken piece, including reqd excavation and earth work in any soil and fixing the new CI pipe and fittings with necessary joints all as dierected and shown by Engr-in-Charge.Note :-1.CI pipe and fittings will be measured & paid separately.2.Lead/Tyton joints will be measured & paid separately(a)Up to 100 mm bore |
| 54 | (b) 150 to 200 mm bore |
| 55 | (c) 250 to 300 mm bore |
| 56 | Supplied and fixed in repair ballvalves high pressure of PTMTwith epoxy coated aluminium rod & high density plastic ball screwed for iron pipe or brass ferrule and fixed of following size all as specified in SSR Pt I complete all as directed.(a)15 MM Bore |
| 57 | (b)20 MM Bore |
| 58 | (c)25 MM Bore |
| 59 | S&F in replacementCI Sluice valve confirming to IS 14846 – 2000 PN-1.0 flanged endsstainless spindle of following sizes with necessary packing materials and nut boltsincl taking down existing sluice valve complete all as directed.(a) 80 MM bore |
| 60 | (b) 100 MM bore |
| 61 | (c) 150 MM bore |
| 62 | (d) 200 MM bore |
| 63 | Dismantling of CI sluice valve complete for replacement of old UNSVspindle Gutka,\"U\" clamp, nut and boltwasher, rubber insertion sheet and gland of suitable size etc and making the sluice valve service able and re-fixing after completerepairing of following sizes :-Note : S/S spindleshall be measured and paid separately under respective item.(a)80 mm bore |
| 64 | (b) 100 mm bore |
| 65 | (c) 150 mm bore |
| 66 | Supply only S/S spindle suitable for following sizes of sluice valve. (a)80 mm bore |
| 67 | (b) 100 mm bore |
| 68 | (c) 150 mm bore |
| 69 | (d) 200 mm bore |
| 70 | Supply only TCCA-19, Complete all as specified ad directed. |
| 71 | Calcium Hypo Chloride minimum 65 % chlorinecomplete all specified and directed |
| 72 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |