| 1 | Provision for Repair/ shifting of existing utilities i.e. HDPE pipe, Cable, UPVC/ CPVC pipe connections of various consumers complete job |
| 2 | Providing Fixing Led light of 50watt (Syska, Havells, Philipsmake) |
| 3 | Providing Fixing Led light of9watt (Syska, Havells, Philipsmake) |
| 4 | wall fan of size Sweep 40 cm (400 mm) Speed 1280 rpm Power Input 55 W |
| 5 | Supply erection, andcommissioning electric operated dewatering pump of 3 HP Kirlosker make complete from priming with wiring starters switches etc. also the required GI pipe (B Class) valves and sight glass etc. complete. |
| 6 | Supply erection, andcommissioning electric operated Vaccume Pump of 2 HP Kirlosker make complete from priming with wiring starters switches etc. also the required GI pipe (B Class) valves and sight glass etc. complete. |
| 7 | Supply and erection of PVC Copper insulated and sheathed 3.0 core circular flexible wire 1100 volts fitted in cable tray (10 sqmm 3.0 core) |
| 8 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mmdia 10 metre openable length fixed on existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart with 5 horizontal R.B.T. reinforced barbed wire, studtied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) |
| 9 | Supply erection testing and commissioning of Flow Meter(KROHNE Make) with digital display at desired place in Pump Chamber of 100 to 400 mm i/d complete in all respect. |
| 10 | Providing and fixing pressure guage 6` dia 0-24 kg/sqcm as per site required complet in all respect |
| 11 | HT METERING PANELSupply erection testing and commissioning of HT metering panel 11 KV consisting of one no electric trivector meter 3 phase 4 wire 0.5 class of accuracy on KW hour point basis complete with HT CTs of 15/5 amp 15 VAburden and class of 0.5 including metering cubical complete in all respects as per site requirement as per HVPN approved make and duly tested by HVPN with required earthing.For Raw Water B/station Khera murar |
| 12 | `AUTOMETIC POWER FACTOR CONTROL PANELSupply erection testing and commissioning of Automatic Power Factor control panel at 90 KVAR capacitor complete with digital screen as per specification mentioned in the as per approved DNIT.`For Water Works Kamalpur |
| 13 | Providing anf fixing of indoor type 11KV Vaccum ciruit breaker (VCB) with indoor swirchgear pannel equipped withCT PT and protection relays of Rated voltage 11KV400A 250 MVA rupturing capacity and short time current rating 13.1 KA for 3sec shunt trip floor mounted horizonTAL ISOLATION horizontal draw out with integral earthing facilitty tested with degree of protection IP4X dustproof vermin proof totally enclosed as per detail specification of make SIEMENS /ABB/ PASCAL/ SCHEINDER complet in all respect |
| 14 | Providing and fixing HT metering panel with GO switch H pole VCB/ACB and all other required electric items complete in all respects as per directions of Engineer-in-charge |
| 15 | Provision for Repair/ shifting of existing utilities i.e. HDPE pipe, Cable, UPVC/ CPVC pipe connections of various consumers complete job |
| 16 | `Boring /excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine in any soil condition complet in all respecti) For M.S. Pipe 550 mm i/d10 mm thick casing pipe.` |
| 17 | `Supply and insertion of 550 mm i/d M.S. Casing pipe 10 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet in all respect i) For 5500 mm i/d M.S. casing pipe 10 mm thick.` |
| 18 | Provision for probe radar survey to check any underground obstruction before finalizing the alignment complete in all respect as per approved |
| 19 | Providing and fixing H.D.P.E. spacer at a distance of 2 meters apart to avoid contract of casing pipe and carrier pipe for 350 mm i/d M.S. pipe 700 mm i/d complete in all respect as per approved NIT.350mm i/d 8mm thick. |
| 20 | Providing and fixing sign board of size 2.5mtrx1.5mtr made out of 75x25 mm SS tube 3mm thick with SS grade 304sheet of 3mm painting with synthetic enamle paint and letter writing NABARD pattern complet in all respect n |
| 21 | SUPPLY,ERECTION,TESTING AND COMMISSIONING OF is MARKED 3 CORE COPPER CABLE SOLID COPPER CONDUTOR UP TO 6 SQMM AND BALANCE STANDARD COPPER XLPE INSULATED CORE LAID UP PVC INNER SHEATED ARMOUR gALVANISEDC WIRE FOR CABLE UPTO 10 X 1.5 SQMM 8 X 2.5SQMM 3 X 10 SQMM 4 X 6 SQMM AND BALANCE ALL GALVANISED STEEL STRIP EXTRUDED PVC TYPE ST2 OUTER SHETAED /1100 V GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATDE AMENDENT ALONG WITH ALL ASESSORIES LIKE THIMBLE LUGS ETC FOR MOTOR AS PER ENTIRE SATISFECTION OF eic COMPLETE IN ALL RESPECT MAKE IN INDIA CABLE LTD FINOLEX/GLOSTER/HAVELLS/POLYCABE/RR CABLES/CAPP/GLOSTER/UNIVERSAL/FORT GLOSTER INDUSTRIAL LTD/ASIAN CABLE COPERTARED LTD 50 SQMM 3 CORE |
| 22 | Providing and fixing Meter, Cable and other relevant materials including approval from DHBVN and PHED as per norms for arrangement to transfer the solar power to DHBVN complete in all respect as per satisfaction of Engineer-in-Charge |
| 23 | Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately):of make IVC 400 mm diameter Class I |
| 24 | Providing and fixing Cast Iron Detachable Joints marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with 15:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately)400 mm i/d |
| 25 | `Supply and insertion of 400 mm i/d M.S. Carriarpipe 8 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet with hydraulic testing in all respect i) For 400 mm i/d M.S. casing pipe 8 mm thick.` |
| 26 | Supply anderction ofaluminum armoundLT cable for 100volts fitted in cable tray complet in all respect as per approved NIT 3.5 core x16 sqm |
| 27 | Providing concrete block 1:1-1/2:3 on both ends to plug the annular space between casing and carrier pipe for 400 mm i/d casing pipe 550 mm i/d complete in all respect |
| 28 | Supply and Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame :- 1000 LPM x 7.5 BHP x 20 mtr Head (RW) |
| 29 | `Supply, erection, testing and commissioning of wall mounted electricalL.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items.a) MCCB 100 amp. 1 No. (LandT Siemens, ABB)b) CT 100/3 = 3Nos. (AE/ KAPPA/ LandT)c) Digital Multi function meter = 2 No.d) SPP = 1 No. of approved makee) Motor starter, Star delta = 3400LPM x120BHP x 90.00 mtr Head (LandT Siemens, ABB) = 2 Nos.f) Capacitor KVAR as per site requirement = 1 No.g) Indicating Lamp= One Seth) Change over switch of suitable Amp = 1 No. (Each)` |
| 30 | ``Boring /excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine in normal soil condition but not in rock/bolder any underground utility like foundation like water supply line comming in alignment or other under grounf obstruction under various location complet in all respect i) including caution sign board signel watching fencing sitr clearing etc i) For M.S. Pipe 450 mm i/d 8.0 mm thick casing pipe.` |
| 31 | `Supply and insertion of 450 mm i/d M.S. Casing pipe 8.0 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet in all respect i) For 450 mm i/d M.S. casing pipe 8.0 mm thick.` |
| 32 | `Providing andfixing H.D.P.E. spacer at a distance of 2 meters apart to avoid contract of casing pipe and carrier pipe for 300 mm i/d M.S. pipe 450 mm i/d complete in all respect as per approved NIT.300mm i/d 6.0 mm thick.` |
| 33 | Providing concrete block 1:1-1/2:3 on both ends to plug the annular space between casing and carrier pipe for 300 mm i/d casing pipe 450 mm i/d complete in all respect |
| 34 | Providing concrete block 1:1-1/2:3 on both ends to plug the annular space between casing and carrier pipe for 400 mm i/d casing pipe 550 mm i/d complete in all respect |
| 35 | Supply and erection of LT copper armound cable for 100volts fitted in cable tray complet in all respect as per approved NIT (3 core x 70 sqm) |
| 36 | Supply anderction of aluminum armound HT cable for 100volts fitted in cable tray complet in all respect as per approved NIT 3.5 core x 120 sqmm |
| 37 | `Supply and insertion of 550 mm i/d M.S. Casing pipe 10 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet in all respect i) For 550 mm i/d M.S. casing pipe 10 mm thick.` |
| 38 | `Supply and insertion of 400 mm i/d M.S. Carriar pipe 8 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet with hydraulic testing in all respect i) For 400 mm i/d M.S. carrier pipe 8 mm thick.` |
| 39 | Supply and erection of Mix Flow Submersible Pumping Set of followingduties directly coupled to AC squirrel cage induction type motor with accessories asdescribed in Schedule No. II complete in all respects.:- 3400 LPM x 120 BHP x 90.00 Mtr. head |
| 40 | Operation and maintenance for the complete scope of work mention in the DNIT (Disinfection material supplied by the PHED) as per Schedule-IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period (will be charged to the A/ Mtc. Estimate)Operation and maintenance during defect liability period (Operation only) |
| 41 | Operation and Maintenance during 1st year after defect liability period year |
| 42 | Operation and Maintenance during 2nd year |
| 43 | Operation and Maintenance during 3rd year |
| 44 | Operation and Maintenance during 4th year |
| 45 | Operation and Maintenance during 5th year |