Tender For Provision Of Weather Shed Along With Facade Over Main Gate And Connection Paths At 5 Afsb Under Ge Af Borjhar
Tender Overview
Project Description
Tender For Provision Of Weather Shed Along With Facade Over Main Gate And Connection Paths At 5 Afsb Under Ge Af Borjhar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Nov-2023 | DATE | Date | 13-Dec-2023 |
| 2 | 21-Nov-2023 | BOQ | BOQ | 13-Dec-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches, n.exc 1.5m wide and n.exc 1.5 m in depth, for foundation, etc., or for shafts, wells, cesspits, manholes, pier holes, etc., n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil, complete all as as directed. |
| 2 | M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete etc., complete all as specified and as directed.(9+7.5) |
| 3 | S & F steel work in tubular trusses and tubular posts including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St. 240 including distance pieces cleats etc., complete all as specified and as directed. (2200+1720) |
| 4 | M & L for mild steel, plain or chequered, cut to shape, hole drilled and welding with connected members, complete all as specified and as directed. (150+37) |
| 5 | M & L for preparationsurfaces of steel of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed. (75+60) |
| 6 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as directed.(9+3.56) |
| 7 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, \"U\" hook or \"J\" bolt, complete all as specified and directed. (75+81) |
| 8 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, \"U\" hook or \"J\" bolt, complete all as specified and directed. (5+10) |
| 9 | M & L for provision of gypsum board of 9mm thick ceiling tiles size 595 mm x 595 mm for including aluminium anodised section of size, wall angle 30mm x 25mm x 2 mm thick, main/cross tee-section 15mm x 15mm x 1.4 mm and suspended with 2.18 mm thick GI wire of suitable length and including fixed and aluminium snap grid all as per clause 10.38.1 of SSR part-I and as per manufacturer\"s instructions. Complete all as specified and as directed by Engr-in-Charge. Make: as specfied in List of approved makes. |
| 10 | S & F for mild steel plates 1.00 mm thick in eaves board, including flat iron clamps, fixed with cadmium screws, complete all as directed. |
| 11 | M & L for 20mm granite (of any type) slab work in vertical suface of RCC columns, including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of the granite slab including over 15 mm thick screed bed layer of cement mortar (1:4), complete all as specified and as directed. |
| 12 | S & F for ACP cladding of 3 mm thick aluminium composite pannel (ACP) sheet with necessary frame work as per manufacturer\"s instructions, complete all as specified and as directed. |
| 13 | M & L for stainless steel chromium plated letters alphabet, Airforce sign, dash, bracket of size 15 cm, including fixing to granite/ACP sheet/MS sheet, complete all as directed. |
| 14 | Excavation in post holes (or similar holes each n.exc 0.50 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth in layers n.exc 25 cm thick watering and removing surplus soil to a distance n.exc 50m and making good disturb ground, as in soft/loose soil, complete all as as directed. |
| 15 | Surface dressing not exc. 15cm deep and getting out in soft/loose soil, complete all as specified and as directed. |
| 16 | Hardcore of broken stone aggregate of gauge n exc 63mm, deposited, spread and levelled in layers not exc, 15cm thick, watered and rolled/rammed to a true surface, complete all as specified and as directed. |
| 17 | M & L for 100 mm thick plain cement concrete (1:3:6) mix, type C-2 using 40mm graded stone aggregate as in sub-base flooring/hard standing, complete all as specified and directed. |
| 18 | M & L forchequered cement concrete tiles 30cm x 30cm x 22mm to 25mmthick,set and jointed with cement slurry in floors with mixture of grey white cement in equal proportion over and including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with grey cement,complete all as specified and directed. |
| 19 | M & L for rendering 15mm thick in cement mortar (1:4)on other than fair faces of brickwork or concrete surface finished even and smooth (without using extra or cement), as in edges of footpath, complete all as specified and directed. |
| 20 | M & L for point wiring for light/fan pointcontrolled by one way switch 5 Amp, 1.5 Sq mm PVC FRLSH insulated unsheathed, copper conductor stranded 1100 volts grade cable including PVC casing and capping of size not less than 25x12 mm/32x12 mm suitable and conduit pipe medium grade as per site requirement, ISI marked with accessories such as tee, bend joint cover etc., round/square blocks at junctions etc., screws, gutti/rawl plug PVC, all as per site requirements including 1.6 mm thick sunk in pressed steel terminal modular box of suitable size for accomodatingswitches/sockets/regulator etc., and PVC FRLSH insulated and unsheathed 1100 volt grade copper conductor, stranded 1.5 Sqmm, cable a continuous earth leadconnected to common earth dolly,etc., complete all as specified and directed. Note: Proper colour coding to be adopted. |
| 21 | All as per item No. 21.00 here-in-before but for one 5 Amp, 5 pin socket point on the same board controlled by one piano switch, complete all as specified and as directed. |
| 22 | All as per item No. 21.00 here-in-before but for one 5 Amp, 5 pin switch socket combinationonindependent board. |
| 23 | All as per item No. 21.00 here-in-before but point wiring for one 3 pin 15 amps socket point on independent board with 2.5 Sqmm size FRLSH PVC insulated, unsheathed, multi stranded, copper conductor cables 1100 volts grade and with 2.5 Sqmm FRLSH PVC insulated unsheathed, single core, multistranded copper conductor cable 1100 volt grade as earth wire complete all as specified and as directed. |
| 24 | Supply and fix ceiling rose surface bakelite 65x50 mm three terminals (ISI marked) PVC/ Polycarbonate, isolated body complete all as specified. |
| 25 | S & F switch modular type 1 way, 10 Amps, 240 volts,one module, complete all as specified and as directed. |
| 26 | S & F switch modular type 1 way, 16 Amps, 240 volts,one module, complete all as specified and as directed. |
| 27 | S & F socket modular type 6/10 Amps, 240 volts, two module, complete all as specified and as directed. |
| 28 | S & F socket modular type 6/16 Amps, 240 volts, two module, complete all as specified and as directed. |
| 29 | S & F MCB DB DD, SPN, 8 way, 240 volts, powder coated sheet metal enclosures single door, complete all as specified and as directed. |
| 30 | S & FMCB, SP, 6 to 32 Amps, breaking capacity , 10 kA, 240 volts, \"B\" series, complete all as specified and as directed. |
| 31 | S & FMCB, DP, 6 to 32 Amps, breaking capacity , 10 kA, 240 volts, \"B\" series, complete all as specified and as directed. |
| 32 | S & F LED luminaires 600mm x 600 mm , 35/36 Watts, 220 V, AC recessed type with high efficiency PMMA diffuser soft glare free light, complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver, complete and connecting upto ceiling rose with three core sheathed copper conductor cable (white/grey/colour) of suitable size, complete all as specified and as directed. Make: As per approved list. |
| 33 | M & L, for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, as shown in electrical plate No.3 of SSR Part-I, connected to earthing testing point all as specified and directed including excavation and connected work in hard/densesoil, PCC 1:3:6 ty C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm dia bore GI light grade as earth lead protection pipe, 50mm thick RCC 1:2:4 type B-1 cover slab of size 300x300x50 mm as earth lead protection pipe, 50 mm thick RCC (1:2:4) type B-1 cover slab of size 300x300x50 mm as earth pit cover reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing complete all as specified and directed. Note : (a) Rate quoted deemed to be included of excavation and earthwork in any type of soil with PCC type C-1 in pit PCC cover (b) Earth test result should not less than one ohm. |
| 34 | S & F modular plate with frame suitable for 3 module, complete all as directed by Engr-in-Charge. Make: As per approved list of Make. |
| 35 | S & F modular plate with frame suitable for 8 module, complete all as directed by Engr-in-Charge. Make: As per approved list of Make. |
| 36 | S & F Modular metal flush box suitable for 1/2 Module, complete including takin down old one, complete all as specified and directed. |
| 37 | S & F Modular metal flush box suitable for 3 Module, complete including takin down old one, complete all as specified and directed. |
| 38 | S & F Modular metal flush box suitable for 8 Module, complete including takin down old one, complete all as specified and directed. |
| 39 | S & F LED flood light 70 Watts 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant, complete with driver and lamp, complete all as specified and directed. |
| 40 | Excavation in trenches, n.exc 1.5m wide and n.exc 1.5 m in depth,and getting out in soft/loose soil, for laying of underground cable, complete all as as directed. |
| 41 | Returning and filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm, complete all as directed. |
| 42 | Supply and spreading sand in cable trenches and providing sand cushioning for the cable complete, complete all as specified and as directed. Note: Only punned thickness of 18cm will be measured for payment. |
| 43 | Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying in trenches complete all as directed by Engineer-in-Charge. |
| 44 | Supply and lay burnt brick of size 230x115x75 mm for protection of cable. |
| 45 | Supply and Laying LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 2 core 10 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge. |
| 46 | S & F GI tubing of 80mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete including taking down old one complete. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender