}

Tender For Purchase And Installation Of Led Minimast In Various Places Of Veliyannoor Grama Panchayat, veliyannoor-Kerala

Grama Panchayat has published Tender For Purchase And Installation Of Led Minimast In Various Places Of Veliyannoor Grama Panchayat. Submission Date for this Tender is 23-11-2023. Electrical Maintenance Tenders in veliyannoor Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40664784
Tender For Purchase And Installation Of Led Minimast In Various Places Of Veliyannoor Grama Panchayat
Open Tender
Indian
Kerala
Veliyannoor
23-11-2023

Tender Details

Purchase And Installation Of Led Minimast In Various Places Of Veliyannoor Grama Panchayat 4 Nos 8Mtr Minimast Light Prov -Iding In Various Places , 4 Nos 8 Meter Minimast Pole, 12Nos 120W Led Flood Light, 4Nos Sintex Meter Board , 4 Nos 32A Fuse Unit, 4Nos 32An / L, 4No Rccb, 4Notimetimer Switch, 4Nos Contactor, 4Nos Earthing, Ls Provision 4Nos , 1 Part I- Providing Mini Mast- ( Materials Used For The Work Shall Be As Per List Of Materials Approved By The District Level Technical Committees And Attached As Separate Document ) , 90.15.1.1:Supply Installation Testing And Commissioning Of Octogaonal Pole Made Of Hot Dip Galvanised Gi Sheet 70Mm Top Diameter. 130Mm Bottom Diameter Thickness 3Mm Base Plate Dimensions Of 200X200x16mm Suitable For Windspeed As Per Is 875 Part Iii Fixed Head Frame Including Round Arm Luminary Carriage Suitable To Install 4 / 6 Nos Luminaries In Symmetrical Arrangement Including Connector Foundation Bolt 4 Nos Existing Rcc Foundation And Junction Box Etc, Complete 8 Meters , 90.15.4.8:Supply Conveyance, Installation, Testing And Commissioning Of 120W Led Flood Light Output Greater Than 105Lumen / W 4000-6000 K With Ip 66 Protection Led Chip Make Cree / Lumilled / Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv, And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , 14.1:Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , 14.7:Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc Including Form Work Etc As Required. , 14.8:Providing And Laying In Position Cement Concrete 1 :3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required. , Od240319 / 2023-2024:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More ( Data 5.22.6 From Civil Work , 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement: 4 Fine Sand ) At All Levels , 90.6.5.11:Supply And Drawing The Following Sizes Of Multi-Core Pvc Insulated & Frlspvc Sheathed 650 / 1100 V Grade Copper Conductor Round Flexible Cables Conforming To Is 694 Part I 1960 In The Existing Surface / Recess Conduit As Required Including Giving Necessary Connections Of The Following Sizes.3 Core 1.50 Sq Mm , 90.12.10.2:Supply & Laying Of Dwc Pipe In Ordinary Soil 0.75M Below Ground Level Including Excavation50 / 38 Mm Or Nearest Size , Od240325 / 2023-2024:Earthing With G.I. Earth Pipe 2 Metre Long 40 Mm Dia ( Medium Class ) Including Providing 12 Mm Dia Drilled Holes Minimum 20 Nos Along The Entire Length In Alternate Arrangement Providing 40X25 Mm Gi Reducer At Top And Test Joint Using 2 Nos , 25X3mm Gi Strip Minimum Size 25 Cm Suitably Shaped And Tightly Clamped To The Pipe Electrode Using 25X6 Mm Steel Bolts Nut And Washer And Providing 2 Nos, 6 Mm Dia Drilled Holes For Clamping And Bolting Earth Lead , And Making Masonry Champer With Cover Plate Having Locking Arrangement And Etc. ( Charcoal And Salt As Required Shall Be Filled At 30 Cm Dia Around The Earth Electrode ) , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg ) , Od240331 / 2023-2024:Supply And Providing 25X6 Mm Brass Bolt And Nut With Washers On The Existing Ms Box / Earth Bus Etc. As Required Including Drilling Necessary Holes As Required , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm ( 10 Swg ) , Od240339 / 2023-2024:Supply And Installation Of Dust And Vermin Proof Wall Mounding Meter Box Sintex Make Gsmb 4537 Or An Equivalent Make With A Base Plate Suitable To Fix 1-Phase Energy Meter And Fix To Fix In The Box 1 No Of 32 A, 415 V Hrc Bakelite Fuse Fitting With Hrc Fuse Link, 32 A 2-Way Neutral Link, And Din Bar Suitable For Fixing Mcb, Timer, Contactor Etc , 90.14.5:Supply And Fabrication Conveyance And Installation Of Angle Iron Frame Work For Wall Mounting Panel Board , Od240394 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 30 / 100 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Od240395 / 2023-2024:Supply And Fixing 32A Backelite Fuse Base With Hrc Fuse Link In The Existing Meter Board And Giving Connections Etc , Od240396 / 2023-2024:Supply And Fixing 32A, 415 V, 2 Way Neutral Link Mounted On Dmc / Smc Base In The Existing Meter Board And Giving Connections Etc. , Od240402 / 2023-2024:Supply And Fixing 25A Ac1, Mnx 9, 2 Pole Power Contactor ( L&T ) Conforming To Is / Iec 60947-4-1 & Iec60947-4-1 In The Existing Enclosure And Giving Connection As Required , Od240403 / 2023-2024:Supply And Fixing Time Switch 240V Ac Din / Base Mounting ( L&T J648b1-Analog Version ) In The Existing Enclosure And Giving Connection As Required. , Od240401 / 2023-2024:Carrying Out Control Wiring For Panel With Normal Meters And Indication Lamps Alone With 650 / 1100 V Grade Pvc Insulated Stranded Single Core Copper Conductor Cables Conforming To Is 694 Part I 1990 For Interconnecting The Control Devices / Equipments Including Providing Suitable Size Insulated Sockets At The Termination Points Or Soldered Properly, Providing Numbering Ferrules For The Proper Identification Of The Wiring, Keeping The Wiring Firm By Suitable Tie / Tie Mounts / Pvc Duct Etc As Required. 4.00 Sq Mm Single Run With Required Sockets. , Od240411 / 2023-2024:Charges For Preparing Drawing Of The Complete Electrical Installation After Completion Of The Present Work And Preparing Completion Report With Kseb Service Connection Application Form And Submitting To The Consumer For Availng 1 Phase Service Connection / Load Regularization

Key Value

Document Fees
INR 845 /-
EMD
INR 9555.0 /-
Tender Value
INR 3.82 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail