Tender For Instrumentation Thermocouple And Earthing Cables Lot 1, numaligarh-Assam

Numaligarh Refinery Limited has published Tender For Instrumentation Thermocouple And Earthing Cables Lot 1. Submission Date for this Tender is 20-12-2023. Electrification Work Tenders in numaligarh Assam. Bidders can get complete Tender details and download the document.




Tender Notice

40663797
Corrigendum : Tender For Instrumentation Thermocouple And Earthing Cables Lot 1
Limitted
Indian
Assam
numaligarh
20-12-2023

Tender Details

Instrumentation Thermocouple And Earthing Cables Lot 1 Instrumentation Thermocouple And Earthing Cables Lot 1 For Numaligarh Refinery Expansion Project , Lot 1 - Flame Retardant Armoured Signal Cables - Is Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Intrinsic Safeas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category : 6.210 Instrument Signal Cable , 12Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code :E5-0.6/1.1-Ttcoco(C)-2.5(12P)Ib Cable Type:Type S31 , 1Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code: E5-0.6/1.1-Ttcoco(C)-2.5(1P)Ib Cable Type:Type S3 , 6Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-2.5(6P)Ib Cable Type:Type S21 , 1Px4 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-4(1P)Ib Cable Type:Types85 , 2Px4 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-4(2P)Ib Cable Type:Type S86 , 6Px1.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(6P)Ib Cable Type:Type S17 , 12Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(12P)Ib Cable Type:Type S93 , 2Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(2P)Ib Cable Tpe:Type S96 , 6Px2.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(6P)Ib Cable Type:Type S97 , 1Px1.5 Is Blue Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-1.5(1P)Ib Cable Type:Type S1 , 12Px1.5 Is Blue Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(12P)Ib Cable Type:Type S27 , Lot-2 - Flame Retardant Armoured Signal Cables - Nis Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Non-Intrinsic Safe As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.210 Instrument Signal Cable , 1Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-2.5(1P)Nk Cable Type:Type S4 , 2Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(2P)Nk Cable Type:Type S11 , 6Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(6P)Nk Cable Type:Type S18 , 12Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(12P)Nk Cable Type:Type S30 , 2Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(2P)Nk Cable Type:Type S14 , 6Px2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(6P)Nk Cable Type:Type S20 , 8Tx2.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-2.5(8T)Nk Cable Type:Type S95 , 1Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(C)-1.5(1P)Nk Cable Type:Type S2 , 12Px1.5 Nis Black Flame Retd. Ls Pvc Arm Ind+Ovl Shld Cable Code:E5-0.6/1.1-Ttcoco(I/C)-1.5(12P)Nk Cable Type:Type S28 , Lot-3 - Fire Resistant Armoured Signal Cables - Is Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Intrinsic Safe As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-1.5(1P)Irb Cable Type:Type S43 , 12Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(12P)Irb Cable Type:Type S71 , 1Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(1P)Irb Cable Type:Type S45 , 6Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(6P)Irb Cable Type:Types61 , 12Px1.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(12P)Irb Cable Type:Type S67 , 6Px1.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(6P)Irb Cable Type:Type S57 , 12Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(12P)Irb Cable Type:Type S94 , 2Px2.5 Is Red+Blue Strip Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(2P)Irb Cable Type:Type S55 , Lot-4 - Fire Resistant Unarmoured Signal Cables - Is Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Unarmoured, Intrinsic Safe As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Is Red+Blue Strip Fire Rest. Lszh Uarm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(C)-1.5(1P)Irb Cable Type: Type S80 , Lot-5 - Fire Resistant Armoured Signal Cables - Nis Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured, Non Intrinsic Safeas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Per Tp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-1.5(1P)Nr Cable Type: Type S44 , 1Tx1.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-1.5(1T)Nr Cable Type: Type S48 , 1Px2.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-2.5(1P)Nr Cable Type:Type S46 , 1Tx2.5 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code: E4-0.6/1.1-Ttcxcx(C)-2.5(1T)Nr Cable Type:Type S91 , 1Px4 Nis Red Fire Rest. Lszh Arm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(C)-4(1P)Nr Cable Type:Type S87 , 12Px1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(12P)Nr Cable Type:Type S68 , 2Px1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(2P)Nr Cable Type:Type S52 , 6Px1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(6P)Nr Cable Type:Type S58 , 6Tx1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(6T)Nr Cable Type:Type S64 , 8Tx1.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-1.5(8T)Nr Cable Type:Type S74 , 12Px2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(12P)Nr Cable Type: Type S70 , 6Px2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(6P)Nr Cable Type:Type S60 , 6Tx2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(6T)Nr Cable Type:Type S98 , 12Px4 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-4(12P)Nr Cable Type:Type S90 , 8Tx2.5 Nis Red Fire Rest. Lszh Arm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxcx(I/C)-2.5(8T)Nr Cable Type:Type S99 , Lot-6 - Fire Resistant Unarmoured Signal Cables – Nis Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Fire Resistant Low Smoke Zero Halogen, St2 Pvc Sheathed, Unarmoured, Non Intrinsic Safeas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.212 Signal Cable- Fire Resistent , 1Px1.5 Nis Red Fire Rest. Lszh Uarm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(C)-1.5(1P)Nr Cable Type:Type S81 , 1Px2.5 Nis Red Fire Rest. Lszh Uarm Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(C)-2.5(1P)Nr Cable Type:Type S82 , 12Px1.5 Nis Red Fire Rest. Lszh Uarm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(I/C)-1.5(12P)Nr Cable Type:Type S83 , 2Px1.5 Nis Red Fire Rest. Lszh Uarm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(I/C)-1.5(2P)Nr Cable Type: Type S84 , 6Px1.5 Nis Red Fire Rest. Lszh Uarm Ind+Ovl Shld Cable Code:E4-0.6/1.1-Ttcxx(I/C)-1.5(6P)Nr Cable Type:Type S79 , Lot-7 - Flame Retardant Thermocuple Cable (K-Type) Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke Low Halogen, St2 Pvc Sheathed, Galvanised Steel Wire Flat Armoured As Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.213 - Instrument Thermocouple Cable , 1Px16awg Yellow Flame Retd. Ls Pvc Arm Ovl Shld T/C-K Cable Code:X4-0.6/1.1-Ttcoco(C)-16(1P)Y Cable Type: Type S37 , Lot-8 - Flame Retardant Earthing Cable Cable For Instrument, Annealed Bare Copper, Xlpe Insulation, Al-Mylar Collective Shielded With Atc Drain Wire, Flame Retardant Low Smoke Low Halogen, St2 Pvc Sheathed, Unarmouredas Per Mr. Note:The Quantity Given Under Column G Is Sum Of Quantity Of Cables As Per Mr And Mandatory Spares Cables As Pertp-1Zzza-Pq-Prc-0005 Nrl Msl Category - 6.210 Instrument Signal Cable , 1Cx6 Green+Blue Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-6(1C)Gb Cable Type:Type E1 , 1Cx6 Green+ Yellow Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-6(1C)Gy Cable Type:Type E2 , 1Cx6 Green Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-6(1C)G Cable Type:Type E3 , 1Cx2.5 Green+ Yellow+ Green Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-2.5(1C)Gyg Cable Type:Type E6 , 1Cx10 Green+ Yellow +Green Strip Flame Retd. Ls Pvc Unarm Cable Code:E5-0.6/1.1-Sc-10(1C)Gyg Cable Type:Type E7 => Limited

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Dec-2023 CORRIGENDUM_01_COMMERCIAL Date 13-12-2023
2 08-Dec-2023 ADDENDUM_01_COMMERCIAL Other 13-12-2023
3 13-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-12-2023

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: SUPPLY OF INSTRUMENTATION CABLES
Sl. No. Item Description
1LOT 1 - FLAME RETARDANT ARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame Retardant Low Smoke, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Intrinsic safeas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category : 6.210 INSTRUMENT SIGNAL CABLE
212Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code :E5-0.6/1.1-TTCOCO(C)-2.5(12P)IB Cable Type:TYPE S31
31Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code: E5-0.6/1.1-TTCOCO(C)-2.5(1P)IB Cable Type:TYPE S3
46Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(6P)IB Cable Type:TYPE S21
51Px4 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(C)-4(1P)IB Cable Type:TYPES85
62Px4 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-4(2P)IB Cable Type:TYPE S86
76Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)IB Cable Type:TYPE S17
812Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)IB Cable Type:TYPE S93
92Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)IB Cable Tpe:TYPE S96
106Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)IB Cable Type:TYPE S97
111Px1.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)IB Cable Type:TYPE S1
1212Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)IB Cable Type:Type S27
13LOT-2 - FLAME RETARDANT ARMOURED SIGNAL CABLES - NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame Retardant Low Smoke, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non-Intrinsic safe as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE
141Px2.5 NIS Black Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(1P)NK Cable Type:TYPE S4
152Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(2P)NK Cable Type:TYPE S11
166Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)NK Cable Type:TYPE S18
1712Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)NK Cable Type:TYPE S30
182Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)NK Cable Type:TYPE S14
196Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)NK Cable Type:TYPE S20
208Tx2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(8T)NK Cable Type:TYPE S95
211Px1.5 NIS Black Flame Retd. LS PVC Arm Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)NK Cable Type:TYPE S2
2212Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)NK Cable Type:TYPE S28
23LOT-3 - FIRE RESISTANT ARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Intrinsic safe as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
241Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)IRB Cable Type:TYPE S43
2512Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-2.5(12P)IRB Cable Type:TYPE S71
261Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)IRB Cable Type:TYPE S45
276Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(6P)IRB Cable Type:TYPES61
2812Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)IRB Cable Type:TYPE S67
296Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)IRB Cable Type:TYPE S57
3012Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)IRB Cable Type:TYPE S94
312Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-2.5(2P)IRB Cable Type:TYPE S55
32LOT-4 - FIRE RESISTANT UNARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Intrinsic safe as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
331Px1.5 IS Red+Blue Strip Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)IRB Cable Type: TYPE S80
34LOT-5 - FIRE RESISTANT ARMOURED SIGNAL CABLES - NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non Intrinsic safeas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as per TP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
351Px1.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)NR Cable Type: TYPE S44
361Tx1.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-1.5(1T)NR Cable Type: TYPE S48
371Px2.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)NR Cable Type:TYPE S46
381Tx2.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code: E4-0.6/1.1-TTCXCX(C)-2.5(1T)NR Cable Type:TYPE S91
391Px4 NIS Red Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-4(1P)NR Cable Type:TYPE S87
4012Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)NR Cable Type:TYPE S68
412Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(2P)NR Cable Type:TYPE S52
426Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)NR Cable Type:TYPE S58
436Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6T)NR Cable Type:TYPE S64
448Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(8T)NR Cable Type:TYPE S74
4512Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)NR Cable Type: TYPE S70
466Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6P)NR Cable Type:TYPE S60
476Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6T)NR Cable Type:TYPE S98
4812Px4 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-4(12P)NR Cable Type:TYPE S90
498Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(8T)NR Cable Type:TYPE S99
50LOT-6 - FIRE RESISTANT UNARMOURED SIGNAL CABLES – NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Non Intrinsic safeas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
511Px1.5 NIS Red Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)NR Cable Type:TYPE S81
521Px2.5 NIS Red Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-2.5(1P)NR Cable Type:TYPE S82
5312Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(12P)NR Cable Type:TYPE S83
542Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(2P)NR Cable Type: TYPE S84
556Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(6P)NR Cable Type:TYPE S79
56LOT-7 - FLAME RETARDANT THERMOCUPLE CABLE (K-TYPE) Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.213 - INSTRUMENT THERMOCOUPLE CABLE
571Px16AWG Yellow Flame Retd. LS PVC Arm Ovl shld T/C-K Cable code:X4-0.6/1.1-TTCOCO(C)-16(1P)Y Cable Type: TYPE S37
58LOT-8 - FLAME RETARDANT EARTHING CABLE Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Unarmouredas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE
591Cx6 Green+Blue Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)GB Cable Type:TYPE E1
601Cx6 Green+ Yellow Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)GY Cable Type:TYPE E2
611Cx6 Green Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)G Cable Type:TYPE E3
621Cx2.5 Green+ Yellow+ Green Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-2.5(1C)GYG Cable Type:TYPE E6
631Cx10 Green+ Yellow +Green Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-10(1C)GYG Cable Type:TYPE E7