Numaligarh Refinery Limited has published Tender For Instrumentation Thermocouple And Earthing Cables Lot 1. Submission Date for this Tender is 20-12-2023. Electrification Work Tenders in numaligarh Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Dec-2023 | CORRIGENDUM_01_COMMERCIAL | Date | 13-12-2023 |
2 | 08-Dec-2023 | ADDENDUM_01_COMMERCIAL | Other | 13-12-2023 |
3 | 13-Dec-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-12-2023 |
Sl. No. | Item Description |
1 | LOT 1 - FLAME RETARDANT ARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame Retardant Low Smoke, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Intrinsic safeas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category : 6.210 INSTRUMENT SIGNAL CABLE |
2 | 12Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code :E5-0.6/1.1-TTCOCO(C)-2.5(12P)IB Cable Type:TYPE S31 |
3 | 1Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code: E5-0.6/1.1-TTCOCO(C)-2.5(1P)IB Cable Type:TYPE S3 |
4 | 6Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(6P)IB Cable Type:TYPE S21 |
5 | 1Px4 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(C)-4(1P)IB Cable Type:TYPES85 |
6 | 2Px4 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-4(2P)IB Cable Type:TYPE S86 |
7 | 6Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)IB Cable Type:TYPE S17 |
8 | 12Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)IB Cable Type:TYPE S93 |
9 | 2Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)IB Cable Tpe:TYPE S96 |
10 | 6Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)IB Cable Type:TYPE S97 |
11 | 1Px1.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)IB Cable Type:TYPE S1 |
12 | 12Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)IB Cable Type:Type S27 |
13 | LOT-2 - FLAME RETARDANT ARMOURED SIGNAL CABLES - NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame Retardant Low Smoke, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non-Intrinsic safe as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE |
14 | 1Px2.5 NIS Black Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(1P)NK Cable Type:TYPE S4 |
15 | 2Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(2P)NK Cable Type:TYPE S11 |
16 | 6Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)NK Cable Type:TYPE S18 |
17 | 12Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)NK Cable Type:TYPE S30 |
18 | 2Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)NK Cable Type:TYPE S14 |
19 | 6Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)NK Cable Type:TYPE S20 |
20 | 8Tx2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(8T)NK Cable Type:TYPE S95 |
21 | 1Px1.5 NIS Black Flame Retd. LS PVC Arm Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)NK Cable Type:TYPE S2 |
22 | 12Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)NK Cable Type:TYPE S28 |
23 | LOT-3 - FIRE RESISTANT ARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Intrinsic safe as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT |
24 | 1Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)IRB Cable Type:TYPE S43 |
25 | 12Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-2.5(12P)IRB Cable Type:TYPE S71 |
26 | 1Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)IRB Cable Type:TYPE S45 |
27 | 6Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(6P)IRB Cable Type:TYPES61 |
28 | 12Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)IRB Cable Type:TYPE S67 |
29 | 6Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)IRB Cable Type:TYPE S57 |
30 | 12Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)IRB Cable Type:TYPE S94 |
31 | 2Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-2.5(2P)IRB Cable Type:TYPE S55 |
32 | LOT-4 - FIRE RESISTANT UNARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Intrinsic safe as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT |
33 | 1Px1.5 IS Red+Blue Strip Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)IRB Cable Type: TYPE S80 |
34 | LOT-5 - FIRE RESISTANT ARMOURED SIGNAL CABLES - NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non Intrinsic safeas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as per TP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT |
35 | 1Px1.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)NR Cable Type: TYPE S44 |
36 | 1Tx1.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-1.5(1T)NR Cable Type: TYPE S48 |
37 | 1Px2.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)NR Cable Type:TYPE S46 |
38 | 1Tx2.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code: E4-0.6/1.1-TTCXCX(C)-2.5(1T)NR Cable Type:TYPE S91 |
39 | 1Px4 NIS Red Fire Rest. LSZH Arm Ovl shld Cable code:E4-0.6/1.1-TTCXCX(C)-4(1P)NR Cable Type:TYPE S87 |
40 | 12Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)NR Cable Type:TYPE S68 |
41 | 2Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(2P)NR Cable Type:TYPE S52 |
42 | 6Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)NR Cable Type:TYPE S58 |
43 | 6Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6T)NR Cable Type:TYPE S64 |
44 | 8Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(8T)NR Cable Type:TYPE S74 |
45 | 12Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)NR Cable Type: TYPE S70 |
46 | 6Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6P)NR Cable Type:TYPE S60 |
47 | 6Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6T)NR Cable Type:TYPE S98 |
48 | 12Px4 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-4(12P)NR Cable Type:TYPE S90 |
49 | 8Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(8T)NR Cable Type:TYPE S99 |
50 | LOT-6 - FIRE RESISTANT UNARMOURED SIGNAL CABLES – NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Non Intrinsic safeas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT |
51 | 1Px1.5 NIS Red Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)NR Cable Type:TYPE S81 |
52 | 1Px2.5 NIS Red Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-2.5(1P)NR Cable Type:TYPE S82 |
53 | 12Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(12P)NR Cable Type:TYPE S83 |
54 | 2Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(2P)NR Cable Type: TYPE S84 |
55 | 6Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(6P)NR Cable Type:TYPE S79 |
56 | LOT-7 - FLAME RETARDANT THERMOCUPLE CABLE (K-TYPE) Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured as per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.213 - INSTRUMENT THERMOCOUPLE CABLE |
57 | 1Px16AWG Yellow Flame Retd. LS PVC Arm Ovl shld T/C-K Cable code:X4-0.6/1.1-TTCOCO(C)-16(1P)Y Cable Type: TYPE S37 |
58 | LOT-8 - FLAME RETARDANT EARTHING CABLE Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Unarmouredas per MR. Note:The Quantity given under "Column "G" is sum of quantity of Cables as per MR and Mandatory Spares Cables as perTP-1ZZZA-PQ-PRC-0005 NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE |
59 | 1Cx6 Green+Blue Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)GB Cable Type:TYPE E1 |
60 | 1Cx6 Green+ Yellow Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)GY Cable Type:TYPE E2 |
61 | 1Cx6 Green Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)G Cable Type:TYPE E3 |
62 | 1Cx2.5 Green+ Yellow+ Green Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-2.5(1C)GYG Cable Type:TYPE E6 |
63 | 1Cx10 Green+ Yellow +Green Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-10(1C)GYG Cable Type:TYPE E7 |