}

Tender For Disposable Blood Collection Bag And Triple Blood Bag Cpd-Sagm., perambur-Tamil Nadu

Southern Railway-SR has published Tender For Disposable Blood Collection Bag And Triple Blood Bag Cpd-Sagm.. Submission Date for this Tender is 23-11-2023. Specimen Collection and Transport Containers Tenders in perambur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

40661362
Tender For Disposable Blood Collection Bag And Triple Blood Bag Cpd-Sagm.
Open Tender
Indian
Tamil Nadu
perambur
23-11-2023

Tender Details

Supply Of Disposable Blood Collection Bag And Triple Blood Bag Cpd-Sagm., ( Sr Ph Code-343010 ) Disposable Blood Collection Bag 350Ml Single Unit:No , ( Sr Ph Code 343023 ) Disposable Triple Blood Collection Bag With Sagm - 350Ml Unit:No , ( Sr Ph Code 343024 ) Triple Blood Bag Cpd-Sagm 450Ml.It Should Have 450Ml Capacity With 63Ml Cpd Solution And Is Connected To One Satellite Transfer Bag Of 450Ml Capacity Andone Satellite Transfer Bag Of 450 Ml With 100 Ml Sagm.Needle Should Be 16G With Triple Bevel Design To Reduce Penetration Force And Enable Painless Vein Puncture.Mother Bag Should Be With Good Quality To Prevent Breakage During Centrifugation And The Inner Diameter Of The Tubes Should Be With Good Quality To Provide Easy Flow Of The Component.Blood Bags Should Have Hot Markings In All Tubes Of The Transfer Bags. Tubes Of Plasma, Platelet And Red Cell Should Have Hot Marking Numbers To Ensure Traceability. Should Be Made Of Pvc With Plasticizer Approved As Per Indian Pharmacopoeia / Dcgi.The Transfer Bag For Platelet Collection Should Contain Plasticizer Compatible For Storage Of Platelets Upto 5 Days.Blood Bags And Its Packing Should Be Properly Labeled With Batch. No., Date Of Mfg., And Date Of Expiry. Product Labels Should Be Barcoded As Per Isbt-128.Secondary Packing And Shipping Cartons Should Be Barcoded As Per Gs1-128 Bags Should Be Packed In An Outer Cover With Sufficient Barrier Properties To Prevent Moisture Loss During Storage.The Plastics Container And The Anticoagulant / Additive Solution Shall Have Been Sterilized By Steam Sterilization Or Any Other Validated Method.The Method Of Sterlization Used Shall Not Adbersely Affect The Materials Or Contents , Nor Cause Any Loosening Of Joints And Deterioration Of Welds In The Plastics Material Nor Any Major Alteration In The Shape Of The Plastics Container.Blood Bags Must Conform To Iso 3826 And Indian Pharmacopoeia For Container, Design, Plastic ( Physical, Chemical, Biological ) Anticoagulant, Labels, And Needle.Needle Must Conform To Iso 1135-3.Proof Of Compliance With Iso 3826 And Iso 1135-3 Should Be Submitted By Company.Market Standing Of More Than 05 Years. Donor Tube Is Provided With Luer Adapter For Online Withdrawal Of Blood Samples Without Contamination.Needle Injury Protector, Predonation Bag Are Also Provided To Ensure More Safety. Unit:No

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item Description
1Disposable Blood Collection Bag And Triple Blood Bag Cpd-Sagm.
2( SR PH CODE-343010) DISPOSABLE BLOOD COLLECTION BAG 350ML SINGLE Unit:NO
3 (SR PH CODE 343023)DISPOSABLE TRIPLE BLOOD COLLECTION BAG WITH SAGM - 350ML Unit:NO
4 (SR PH CODE 343024)TRIPLE BLOOD BAG CPD-SAGM 450ML.IT SHOULD HAVE 450ML CAPACITY WITH 63ML CPD SOLUTION AND IS CONNECTED TO ONE SATELLITE TRANSFER BAG OF 450ML CAPACITY ANDONE SATELLITE TRANSFER BAG OF 450 ML WITH 100 ML SAGM.NEEDLE SHOULD BE 16G WITH TRIPLE BEVEL DESIGN TO REDUCE PENETRATION FORCE AND ENABLE PAINLESS VEIN PUNCTURE.MOTHER BAG SHOULD BE WITH GOOD QUALITY TO PREVENT BREAKAGE DURING CENTRIFUGATION AND THE INNER DIAMETER OF THE TUBES SHOULD BE WITH GOOD QUALITY TO PROVIDE EASY FLOW OF THE COMPONENT.BLOOD BAGS SHOULD HAVE HOT MARKINGS IN ALL TUBES OF THE TRANSFER BAGS. TUBES OF PLASMA, PLATELET AND RED CELL SHOULD HAVE HOT MARKING NUMBERS TO ENSURE TRACEABILITY. SHOULD BE MADE OF PVC WITH PLASTICIZER APPROVED AS PER INDIAN PHARMACOPOEIA/DCGI.THE TRANSFER BAG FOR PLATELET COLLECTION SHOULD CONTAIN PLASTICIZER COMPATIBLE FOR STORAGE OF PLATELETS UPTO 5 DAYS.BLOOD BAGS AND ITS PACKING SHOULD BE PROPERLY LABELED WITH BATCH. NO., DATE OF MFG., AND DATE OF EXPIRY. PRODUCT LABELS SHOULD BE BARCODED AS PER ISBT-128.SECONDARY PACKING AND SHIPPING CARTONS SHOULD BE BARCODED AS PER GS1-128 BAGS SHOULD BE PACKED IN AN OUTER COVER WITH SUFFICIENT BARRIER PROPERTIES TO PREVENT MOISTURE LOSS DURING STORAGE.THE PLASTICS CONTAINER AND THE ANTICOAGULANT/ADDITIVE SOLUTION SHALL HAVE BEEN STERILIZED BY STEAM STERILIZATION OR ANY OTHER VALIDATED METHOD.THE METHOD OF STERLIZATION USED SHALL NOT ADBERSELY AFFECT THE MATERIALS OR CONTENTS ,NOR CAUSE ANY LOOSENING OF JOINTS AND DETERIORATION OF WELDS IN THE PLASTICS MATERIAL NOR ANY MAJOR ALTERATION IN THE SHAPE OF THE PLASTICS CONTAINER.BLOOD BAGS MUST CONFORM TO ISO 3826 AND INDIAN PHARMACOPOEIA FOR CONTAINER,DESIGN,PLASTIC(PHYSICAL,CHEMICAL,BIOLOGICAL)ANTICOAGULANT,LABELS,AND NEEDLE.NEEDLE MUST CONFORM TO ISO 1135-3.PROOF OF COMPLIANCE WITH ISO 3826 AND ISO 1135-3 SHOULD BE SUBMITTED BY COMPANY.MARKET STANDING OF MORE THAN 05 YEARS. DONOR TUBE IS PROVIDED WITH LUER ADAPTER FOR ONLINE WITHDRAWAL OF BLOOD SAMPLES WITHOUT CONTAMINATION.NEEDLE INJURY PROTECTOR,PREDONATION BAG ARE ALSO PROVIDED TO ENSURE MORE SAFETY. Unit:NO
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail