Tender For Provision Of Certain Revenue And Minor Works Under Ge ( South ) Bangalore.; 1 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Cleaning And Washing Down With Water To Remove Dust, Etc And Brushing With Neat Cement Slurry Using Cement At 3Kg / Sqm All As Specified And As Directed. 2 Demolition Of Cement Concrete In Ground Floors And Pavings Not Exceeding 15 Cm Thickness ( Below Or Above Ground Floor ) Complete All As Specified And As Directed. 3 M&L For 100Mm Thick Cement Concrete Type B-2, 1:2:4 ( Using 40Mm Graded Crushed Stone Aggregate ) , As In Sub Base Of Floor All As Specified And Directed. 4 M&L For Machine Cutkota Stone Slab Flooring 20-25Mm Thick Over And Including Cement Screed20mm Thick In Cm 1:6 Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete As Specified And As Directed. 5 M&L For Machine Cutkota Stone 20-25Mm Thick Over And Including 15Mm Thick Plaster In Cm 1:4 In Vertical Surfaces Like Skirting, Steps, Pillarsetc Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete As Specified And As Directed. 6 Demolition Of Brickwork Or Stone Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, But Excluding Ashlar Facings, Dressed Stone Work And Precast Concrete Articles Complete All As Specified And As Directed. 7 M&L For Pre-Cast Cement Concrete 1:3:6 Type C1 ( Using 20Mm Graded Stone Aggregate ) As In Block Masonry With Solid Blocks, Exc. 10Cm In Width And Setting In Cement Mortar 1:6, Complete All As Specified And As Directed. 8 M&L Pcc 1:2:4, Type B0 ( Using 12.5Mm Graded Stone Aggregate ) For Embedding Of Fencing Posts Incl All Necessary Form Work Complete All As Specified And Directed. 9 Excavation In Trenches, Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M Depth For Foundation, Etc., And Nexc 10 Sq M On Plan And Getting Out In Soft / Loose Soil Incl Getting Out Complete And Diposited Where Directed Upto 50 Mtr Distance Complete All As Specified And As Directed. 10 M & L Cement Concrete 1:4:8 Type D-2 ( Using 40 Mm Graded Crushed Stone Aggregate ) In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 11 Returning, Filling In, Including Spreading, Leveling, Watering And Well Ramming In Laysers Not Exc 25Cm In Soft / Loose Soil Complete All As Specified And As Directed. 12 Removing Excavted Materials Not Exc 50 M Anddepositing Where Directed At A Level N. Exc. 1.5 M Above The Starting Point Complete All As Specified And Directed. 13 M&L Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 Including Finising The Surfaces Even And Smooth Without Using Extra Cement Including Taking Down Complete All As Specified And As Directed. 14 M &L For Rendering 15Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 And Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 15 M&L Preparation Of Newly Plastered Surfaces Of Wall And Applying Two Coats Of Cement Base Paint Over A Coat Of Cement Primer Complete All As Specified And As Directed. 16 M&L For One Coat Of Cement Base Painting Including Preparation Of Old Plastered Surfaces Of Walls Complete All As Specified And Directed. 17 M&L For 25Mm Dia Gi Pipe Of Medium Grade Laid In Trenches / Fixing To Walls With All Fittings Etc Complete All As Specified And As Directed. 18 M&L For Plain Cement Concrete 1:3:6 Type C1 Using 20Mm Graded Stone Aggregate For Coping Complete All As Specified And Directed. 19 S&F For Mild Steel Work In Fencing Posts And Struts Including Tops To Shape, Drilling Holes, Notching For Wire, Flat Iron Fillets, Tie Barsincluding All Necessary Drilling, Bolting Or Riveting, Etc.And Similar Work Conforming To Fe-290 Gde E-165Etc Complete All As Specified And As Directed. 20 S&F Galvanised 2 Strand, Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacings And Straining And Fixing To Any Type Of Standard Rails Straining Bolts Including, Securing Or Tying At Crossing With And Provision Of Galvanised Mild Steel Wire Staples Or Steel Pins Etc As Directed All As Specified. 21 M&L For Preparation Of New Or Previously Untreated Steel Surfaces Of Any Description Over 10Cm Width Or Girth Not Otherwise Described And Applying Two Coats Of Synthetic Neamel Paint Over A Coat Of Red Oxide Zinc Chrome Primer.Etc Complete All As Specified And Directed 22 S&F Concertina Coil Of 600Mm Dia, Made Out Of 2.5Mm Dia Spring Wire 230 Gm / Sqm ( Min ) Dipped With Corrosive Preventive Fluid ( Rusilo 901 ) Of Castrol Make In White Colour Each Coil Having A Minimum 40 Turns ( Circle ) And An Average Weight Not Less Than 15 Kg / Roll ( Plus Or Minus 5% ) Razor Length Minimum 10Mm And Spacing Between Razors Max 25Mm Centre To Centre Including Handle And Spike At Both Ends Of Coil ( Length Of Each Coil 8M ) Errected In Position On Top Of Mild Steel Angles Ms Rod For Securing Incl Necessary Welding To The Ms Sections Etcfixing With Cold Rolled Carbon Strip Of Thickness 0.45Mm, Width Of Tape 12 To 15 Mm Complete All As Specified And As Directed .Note : Measurement Shall Be Made For Length Of Fencing ( Flat Measurement ) 23 Cutting Screwing The Existing Gi Pipe For Connecting Tee Pieces, Bends , Sockets Etc To Make New Connection Upto 50Mm Dia Etc Complete All As Specified And Directed. 24 S & F In Repairs 25Mm Dia Gun Metal Gate Valvewith Iron Wheelhead, Screwed Both Ends For Iron Pipe Etc Complete All As Specified And Directed. 25 S & F 25Mm Dia Float Valve High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule Etc Complete All Specified And Directed. 26 M&L For Rendering 10 Mm Thick In Cm 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Such As Wall Finished Even And Fair Without Using Extra Cement Complete All As Specified And Directed. 27 M&L For Pre Cast Rcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate For Lintelset In Cement Mortar ( 1:4 ) Complete All As Specified. 28 M&L Mild Steel Tmt Bars 10 Mm Dia., And Over Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia., Or Securing With Clips Complete All As Specified And As Directed. 29 All As Per Item No.28Above Here In Before But 6 To 8Mm Dia Complete All As Specified And As Directed. 30 S&F 4.0 Mm Thick Figured Glass, Pin Head Type And Glazing With Aluminium Beading & Rubber Gasket In Each Panes In Square N.Exc 0.5 Sqm In Each Pane In Louvers Complete All As Specified And As Directed. 31 M&L75mm Thick Cement Concrete1:4:8 Type D-2, ( Using 40 Mm Gradedstone Aggregate ) In Sub Base Of Flooring / Hard Standing Complete All As Specified And As Directed. 32 M&L 25Mm Thick Pcc 1:2:4 Type B-0 ( Using 12.5 Mm Gradedstone Aggregate ) In Floorings Including Finishing The Surface Even And Fairwithout Extra Cement Complete All As Specified And As Directed. 33 M&L For Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over A Screed Of 15Mm Thick In Cm 1:6 Etc Complete All As Specified And Directed. 34 S&F Coloured Glazed Ceramic Tile In Vertical Surface 300X450x7 Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over And Including 10 Mm Thick Rendering Cm 1:4 Backing Coat Complete All As Specified And As Directed. 35 M & L For Applyingthree Coats Of White Wash On Wallnewly Plastered Surfacesincl Preparingthe Surfaces. Etc And Cleaning All Window Panes From Splashes / Dropping All As Specified Anddirected. 36 S&F 500 Ltrs Capacity Rotational Moulded Polyethylene Water Storage Tanks ( Cylinderical Vertical With Closed Top ) Vhoilsted And Fixed In Position Incl 2 No, S 25Mm Tank Nipple With Check Nut And 01 No, S 25Mm Float Valveall As Specified In Ssr Part-Icomplete All As Specified & Directed By Engineer-In-Charge. 37 Supplying And Laying Of Cpvc Gate Valve 25Mm Diacomplete All As Specified. 38 Supplying And Laying Of Cpvc Union 25Mm Diacomplete All As Specified. 39 S & F In Repair Of Cpvc Pipes 25Mm Incl. Sdr 11Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified. 40 S & Fof Cpvc Pipes 20Mm All Sdr 11 Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified. 41 S&F Of 20 Mm Dia Cpvc Brass Elbow Complete All As Specified And As Directed. 42 S&F Of 20 Mm Dia Male Brass Threaded Adapter Complete All As Specified And As Directed. 43 S&F Of 20 Mm Dia Female Brass Threaded Adapter Complete All As Specified And As Directed. 44 S&F Pvc ( Swr ) 110 Mm Bore Pipes Single Socketed, In Any Length With Rubber Ring Joints Laid In Floors Including Dismantling And Breaking Of Pipe And Fittings Complete All As Specified And As Directed. 45 S&Fpvc ( Swr ) 75 Mm Bore Pipes Single Socketed, In Any Length With Rubber Ring Joints Laid In Floors Complete All As Specified And As Directed. 46 S&Fpvc Bends Anyradius75mm Diacomplete All As Specified And As Directed. 47 S&F Pvc Bends Anyradius 110Mm Diacomplete All As Specified And As Directed. 48 S &F In Repairs Vitreous Chinaware Urinal Half Stall Type White With Grating & Union For Discharge Pipe Down Take Pipe Etc. 49 S&F 15 Mm Bore Push Taps Suitable For Urinals Any Colour Of Ptmt Screwed For Iron Pipe And Including Urinal Spreader Fixed In Repairs ( Minium Weight 15 Mm-47Gms ) .Complete All As Directed 50 S&F In Repairs Pvc Connection 15 Mmsize, 60 Cm Long With Ptmt Adopter, Check Nutsand Washer On Both Sides For Hot Water Complete All As Specified. 51 S&F In Repair 32 Mm Dia Pvc Waste Pipe For Urinals Complete All As Specified. 52 M&L For 18-20 Mmthick Granite Telephonic Black Including Round Cutting Work Forwash Hand Basin / Sink ( Table Rubbed And Polished ) As In Cooking Platforms , Steps, Jambs, Urinals Partitions, Pillars, Window Cills, And Like In15mm Thick Cement Mortar ( 1:4 ) Incl Pointing In White Cement ( 1:2 ) Using Mable Dust With Admixture Of Pigments To Match With Shade Of Granite And Likecomplete All As Specified And As Directed. 53 M & L For Hardcore Of Gauge Not Exceeding 63 Mm Of Broken Granite Stone, Deposited, Spread And Levelled In Layers Not Exceeding 15 Cm Thick, Watered And Rammed To A True Surface.Etc Complete All As Specified 54 M & L 75 Mm Thick Pcc ( 1:3:6 ) Type C1 Using40mm Graded Stone Aggregate As In Plinth Protections With Joint Cutting And Joint Filling With Bitumen Grade B Etc Complete All As Specified. 55 M&L Cutting Into 100Mm Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel ( 1 / 2 Round Or 3 / 4 Section ) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required 56 Excavation In Post Holes In Soft Loose Soil ( Or Similar Holes ) Each N.Exc 0.5 Cum Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering And Removing Surplus Soil To A Distance Not Exc 50Mtr And Making Good Surface. 57 M&L Pcc 1:2:4 Type B1 Using20 Mm Graded Stone Aggregate As In Foundation, Fillings And Mass Concrete Complete All As Specified 58 S&F Fe 410 -W ( Gde- E- 250 ) Quality- B Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. ( Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated ) Complete All As Specified & Directed By Engineer -In-Charge. 59 S&F Fe 410 -W ( Gde- E- 250 ) Quality- A Ms Plates ( Plain Or Chequered ) Channel, Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes, With Riveted, Bolted Or Welded Attachment Complete All As Specified & Directed By Engineer -In-Charge. 60 S & F Fe 410 -W ( Gde- E- 250 ) Quality- B Ms Rectangular Or Square Hollow Sectionsteel Work In Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleatsetc. Complete All As Specified & Directed By Engineer -In-Charge. 61 S&F 0.50Mm Thick Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheetof Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified Complete. 62 M&L Surface Dressing N Exc 15 Cm Deep In Soft / Loose Soil. Including Clearing Away All Loose Materials Complete All As Specified. 63 M&L 100Mm Thick Cement Concrete 1:4:8 Type D-2 As In Sub Base Etccomplete All As Specified & Directed 64 M&L 15 Mm Thick Screed Bed Or Bedding Layerin Cement Mortar 1:6 For Laying Floor Finishing Complete All As Specified . 65 M&L For Chequered Cement Concrete Tiles 40Cm X 40Cm X 25Mm Thick With Grey Cement And Pigments, Set, Jointed And Pointed In Neat Cement Slurry In Floors Etc Complete All As Specified. 66 M & L Point Wiring Surface Type With 4.0 Sqmm Pvc Insulated Unsheathed Multistranded Single Core Copper Conductor Cable ( Frls ) Including 4.0 Sqmm Pvc Insulated Copper Conductor Earth Continuity Wire Drawn In And Including Isi Pvc.Casing Capping Not Less Than 20Mm Width And Fixed In Existing Boxes And Covered With 3Mm Th Laminated Sheet Cover And Screws Foe One 3Pin 15A Socket Outlet Point On Independent Board Etc Completed All As Specified And Directed. 67 S & F Socket Out 2 In 1 3 Pin 6Aflush Type Multipurpose Complete All As Specified And As Directed. 68 S & F Plug Top 3 Pin 16A Complete All As Specified And As Directed. 69 M & L For Sub Main Wiring Concealed Type Complete With Two Single Core 06 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Conductor Cable One Single Run Of 6 Sqmm Fr Pvc Insulated Unsheathed Stranded Copper Earth Cable ( Drawn Through In And Including 20Mm Dia Pvc Conduit Pipe Accessories Including Elbow, Tee ) Connected To Common Earth Dolly Complete All As Specified And As Directed.Note : Two Run Of 06 Sqmm And One Run Of 6Sqmm Earth Wire And Pvc Conduit Has Been Measured As One Unit For Payment. Bidders Are Requested To Quote Accordingly. 70 S & F Inrepairs Sheet Metal Enclosure Spn For DbS When McbS To Be Used With 240 Amps Bus Bar 200 Volt Double Door 8 Way Complete All As Specified And As Directed. 71 S & Fin Repairs Mcb Spn 32 Amps 240V C Curve Complete All As Specified And As Directed. 72 S & F In Repairs Mcb Sp 5 To 32Amps 240 VoltsC Curve All As Specified And As Directed. 73 M & L Earthing Complete With Gi Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Burried Directly In Ground ( Earth Plate Not Less Than 2.25Metre Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5Metre Below Normal Ground Level Connected To Galvanished Earth Wire 4.0Mm Dia By Means Of Bolts, Nuts Check And Washers Of Gi Or Steel All As Shown In Electrical Plate No 3 Of Ssr Part I Connected To Earthing Test Point All As Specified Or Indicated Including Gi Pipe 40Mm Dia Light Grade For Earth Wire Protection, Necessary Excavation, Earthwork In Any Type Of Soil, Pcc Chamber And Rcc Cover Slab, Connecting Lead Wire From Test Point To Db Complete All As Specified And As Directed. 74 S & F Cpvc Pipes 20Mm All Sdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling And Necessary Connection For Fittments Of Geysers Etc Complete All As Specified And As Directed. 75 S & F 20Mm Dia Cpvc Brass Elbow Etc Complete All As Specified And As Directed. 76 S & F 20Mm Dia Bib Taps Cast Copper Alloy Fancy Type Chromium Plated Screweddown Crewed High Pressure With Capstan Head Screwed Down For Iron Pipe Etc Complete All As Specified And As Directed. 77 S & F Water Heater Storage Type Electric Capacity 25Litres, Steel Body With Copper Inner Ank And Heating Element Upto 2 Kw, Bee 5 Star Rated Complete With All Accessories Such As Safety Valve, Thermostate, Nrv, Connection Piece Etc And Including Connecting Up With Three Core Copper Conductor Cable With 15Amps Plug Top Complete All As Specified And As Directed. 78 M&L Required For Cutting Pipes Including Making Walls Good Of Bathrooms With Masonry Works Etc Complete All As Specified. 79 M&L For Sand Cushioning In Trenches For Bricks Of Ug Cable Laid Dry With Uniform Thickness Etc Complete All As Specified. 80 S&L Burnt Bricks Of Sub Class B Laid Dry Across In Trenches For Cable Protection Etc Complete All As Specified. 81 Supply, Laying And Testingcable Xlpe Insulated, Screened, Pvc Bedded Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 10 Sqmm X 2 Core Including Taking Down Unserviceable Ug Cable Complete All As Specified And Directed. ( Make- Plaza / Havells / Finolex )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Nov-2023 Date Corrigendum Date 05-12-2023
2 25-Nov-2023 BOQ BOQ 05-12-2023
3 05-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-12-2023
4 12-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVN OF CERTAIN REVENUE AND MINOR WORKS UNDER GE(SOUTH) BANGALORE.
Sl. No. Item Description
1Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust, etc and Brushing with neat cement slurry using cement at 3kg/Sqm all as specified and as directed.
2Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground floor) complete all as specified and as directed.
3M&L for 100mm thick cement concrete type B-2, 1:2:4 (using 40mm graded crushed stone aggregate), as in sub base of floor all as specified and directed.
4M&L for machine cutkota stone slab flooring 20-25mm thick over and including cement screed20mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as specified and as directed.
5M&L for machine cutkota stone 20-25mm thick over and including 15mm thick plaster in CM 1:4 in vertical surfaces like skirting, steps, pillarsetc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as specified and as directed.
6Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
7M&L for pre-cast cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in block masonry with solid blocks, exc. 10cm in width and setting in cement mortar 1:6, complete all as specified and as directed.
8M&L PCC 1:2:4, type B0 (using 12.5mm graded stone aggregate)for embedding of fencing posts incl all necessary form work complete all as specified and directed.
9Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, etc., and nexc 10 sq m on plan and getting out in soft/loose soil incl getting out complete and diposited where directed upto 50 mtr distance complete all as specified and as directed.
10M & L cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
11Returning, filling in, including spreading, leveling, watering and well ramming in laysers not exc 25cm in soft/loose soil complete all as specified and as directed.
12Removing excavted materials not exc 50 m anddepositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
13M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 including finising the surfaces even and smooth without using extra cement including taking down complete all as specified and as directed.
14M &L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed.
15M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and as directed.
16M&L for one coat of cement base painting including preparation of old plastered surfaces of walls complete all as specified and directed.
17M&L for 25mm dia GI pipe of medium grade laid in trenches/fixing to walls with all fittings etc complete all as specified and as directed.
18M&L for plain cement concrete 1:3:6 Type C1 using 20mm graded stone aggregate for coping complete all as specified and directed.
19S&F for mild steel work in fencing posts and struts including tops to shape, drilling holes, notching for wire, flat iron fillets, Tie barsincluding all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe-290 Gde E-165etc complete all as specified and as directed.
20S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including, securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed all as specified.
21M&L for preparation of new or previously untreated steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic neamel paint over a coat of red oxide zinc chrome primer.etc complete all as specified and directed
22S&F concertina coil of 600mm dia, made out of 2.5mm dia spring wire 230 gm/sqm (min) dipped with corrosive preventive fluid (rusilo 901) of castrol make in white colour each coil having a minimum 40 turns (circle) and an average weight not less than 15 kg/roll (plus or minus 5%) razor length minimum 10mm and spacing between razors max 25mm centre to centre including handle and spike at both ends of coil (length of each coil 8m) errected in position on top of mild steel angles MS rod for securing incl necessary welding to the MS sections etcfixing with cold rolled carbon strip of thickness 0.45mm, width of tape 12 to 15 mm complete all as specified and as directed .Note : Measurement shall be made for length of fencing (flat measurement)
23Cutting screwing the existing GI pipe for connecting Tee pieces,bends ,sockets etc to make new connection upto 50mm dia etc complete all as specified and directed.
24S & F in repairs 25mm dia Gun metal gate valvewith iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed.
25S & F 25mm dia float valve high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule etc complete all specified and directed.
26M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces such as wall finished even and fair without using extra cement complete all as specified and directed.
27M&L for Pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate for lintelset in cement mortar (1:4) complete all as specified.
28M&L Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
29All as per item no.28above here in before but 6 to 8mm dia complete all as specified and as directed.
30S&F 4.0 mm thick figured glass, pin head type and glazing with aluminium beading & rubber gasket in each panes in square n.exc 0.5 sqm in each pane in louvers complete all as specified and as directed.
31M&L75mm thick Cement concrete1:4:8 type D-2, (using 40 mm gradedstone aggregate) in sub base of flooring/ hard standing complete all as specified and as directed.
32M&L 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm gradedstone aggregate) in floorings including finishing the surface even and fairwithout extra cement complete all as specified and as directed.
33M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed of 15mm thick in CM 1:6 etc complete all as specified and directed.
34S&F coloured glazed ceramic tile in vertical surface 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering CM 1:4 backing coat complete all as specified and as directed.
35M & L for applyingthree coats of white wash on wallnewly plastered surfacesincl preparingthe surfaces. etc and cleaning all window panes from splashes / dropping all as specified anddirected.
36S&F 500 ltrs capacity rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top)vhoilsted and fixed in position incl 2 No,s 25mm tank Nipple with check nut and 01 No,s 25mm float valveall as specified in SSR Part-Icomplete all as specified & directed by Engineer-in-Charge.
37Supplying and laying of CPVC gate valve 25mm diacomplete all as specified.
38Supplying and laying of CPVC Union 25mm diacomplete all as specified.
39S & F in repair of CPVC pipes 25mm Incl. SDR 11Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
40S & Fof CPVC pipes 20mm all SDR 11 Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
41S&F of 20 mm dia CPVC brass elbow complete all as specified and as directed.
42S&F of 20 mm dia male brass threaded adapter complete all as specified and as directed.
43S&F of 20 mm dia female brass threaded adapter complete all as specified and as directed.
44S&F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints laid in floors including dismantling and breaking of pipe and fittings complete all as specified and as directed.
45S&FPVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints laid in floors complete all as specified and as directed.
46S&FPVC bends anyradius75mm diacomplete all as specified and as directed.
47S&F PVC bends anyradius 110mm diacomplete all as specified and as directed.
48S &F in repairs vitreous chinaware urinal half stall type white with grating & union for discharge pipe down take pipe etc.
49S&F 15 mm bore push taps suitable for urinals any colour of PTMT screwed for iron pipe and including Urinal spreader fixed in repairs (Minium weight 15 mm-47gms).complete all as directed
50S&F in repairs PVC connection 15 mmsize, 60 cm long with PTMT adopter,check nutsand washer on both sides for hot water complete all as specified.
51S&F in repair 32 mm dia PVC waste pipe for urinals complete all as specified.
52M&L for 18-20 mmthick Granite Telephonic black including round cutting work forwash hand basin / sink (table rubbed and polished) as in cooking platforms , steps, jambs, urinals partitions, pillars, window cills,and like in15mm thick cement mortar (1:4) incl pointing in white cement (1:2) using mable dust with admixture of pigments to match with shade of granite and likecomplete all as specified and as directed.
53M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.etc complete all as specified
54M & L 75 mm thick PCC (1:3:6) type C1 using40mm graded stone aggregate as in plinth protections with joint cutting and joint filling with Bitumen grade "B" etc complete all as specified.
55M&L Cutting into 100mm existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required
56Excavation in post holes in soft loose soil (or similar holes) each n.exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exc 50mtr and making good surface.
57M&L PCC 1:2:4 type B1 using20 mm graded stone aggregate as in foundation, fillings and mass concrete complete all as specified
58S&F Fe 410 -W (Gde- E- 250) quality- B Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified & directed by Engineer -in-Charge.
59S&F Fe 410 -W (Gde- E- 250) quality- A MS plates (Plain or chequered) channel, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified & directed by Engineer -in-Charge.
60S & F Fe 410 -W (Gde- E- 250) quality- B MS rectangular or Square hollow sectionsteel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing(Beam, tee, angle, channel or flat sections) including distance pieces, cleatsetc. complete all as specified & directed by Engineer -in-Charge.
61S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheetof any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified complete.
62M&L Surface dressing n exc 15 cm deep in soft/loose soil. Including Clearing away all loose materials complete all as specified.
63M&L 100mm thick cement concrete 1:4:8 type D-2 as in sub base etccomplete all as specified & directed
64M&L 15 mm thick screed bed or bedding layerin cement mortar 1:6 for laying floor finishing complete all as specified .
65M&L for chequered cement concrete tiles 40cm x 40cm x 25mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors etc complete all as specified.
66M & L point wiring surface type with 4.0 Sqmm PVC insulated unsheathed multistranded single core copper conductor cable (FRLS) including 4.0 Sqmm PVC insulated copper conductor earth continuity wire drawn in and including ISI PVC.casing capping not less than 20mm width and fixed in existing boxes and covered with 3mm th laminated sheet cover and screws foe one 3pin 15A socket outlet point on independent board etc completed all as specified and directed.
67S & F socket out 2 in 1 3 pin 6Aflush type multipurpose complete all as specified and as directed.
68S & F plug top 3 pin 16A complete all as specified and as directed.
69M & L for sub main wiring concealed type complete with two single core 06 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable one single run of 6 Sqmm FR PVC insulated unsheathed stranded copper earth cable (drawn through in and including 20mm dia PVC conduit pipe accessories including elbow, tee) connected to common earth dolly complete all as specified and as directed. Note : Two run of 06 sqmm and one run of 6Sqmm earth wire and PVC conduit has been measured as one unit for payment. Bidders are requested to quote accordingly.
70S & F inrepairs sheet metal enclosure SPN for DB"s when MCB"s to be used with 240 Amps bus bar 200 volt double door 8 Way complete all as specified and as directed.
71S & Fin repairs MCB SPN 32 Amps 240V "C " curve complete all as specified and as directed.
72S & F in repairs MCB SP 5 to 32Amps 240 volts"C " curve all as specified and as directed.
73M & L earthing complete with GI earth plate Electrode 60cm x 60cm x 6mm thick burried directly in ground (earth plate not less than 2.25metre deep below ground level) with top edge of the plate not less than 1.5metre below normal ground level connected to galvanished earth wire 4.0mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including GI pipe 40mm dia light grade for earth wire protection, necessary excavation, earthwork in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified and as directed.
74S & F CPVC pipes 20mm all SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling and necessary connection for fittments of geysers etc complete all as specified and as directed.
75S & F 20mm dia CPVC brass elbow etc complete all as specified and as directed.
76S & F 20mm dia Bib taps cast copper alloy fancy type chromium plated screweddown crewed high pressure with capstan head screwed down for Iron pipe etc complete all as specified and as directed.
77S & F water heater storage type electric capacity 25litres, steel body with copper inner ank and heating element upto 2 KW, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc and including connecting up with three core copper conductor cable with 15Amps plug top complete all as specified and as directed.
78M&L required for cutting pipes including making walls good of bathrooms with masonry works etc complete all as specified.
79M&L for sand cushioning in trenches for bricks of UG cable laid dry with uniform thickness etc complete all as specified.
80S&L burnt bricks of sub class "B "laid dry across in trenches for cable protection etc complete all as specified.
81Supply, laying and testingcable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm x 2 core including taking down unserviceable UG cable complete all as specified and directed. (Make- Plaza/ Havells/ Finolex)