Tender For Provision Of Store Room For Xxx Mt At Rangapahar Mil Station., dimapur-Nagaland

Military Engineer Services-MES has published Tender For Provision Of Store Room For Xxx Mt At Rangapahar Mil Station.. Submission Date for this Tender is 18-12-2023. Wrenches and Drivers Tenders in dimapur Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

40654572
Corrigendum : Tender For Provision Of Store Room For Xxx Mt At Rangapahar Mil Station.
Open Tender
Indian
Nagaland
dimapur
18-12-2023

Tender Details

Tender For Provision Of Store Room For Xxx Mt At Rangapahar Mil Station.; 1 Surface Excavation N.Exc 30 Cm Deep And Averaging 15Cm Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 2 Excavation In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Soft / Loose Soil Etc Complete All As Specified And As Directed. 3 All As Per Item No 02 Above But Depth Exc 1.5M But N.Exc 3Mcomplete All As Specified And As Directed. 4 Material And Labour For Pcc ( 1:2:4 ) Type B2 ( Using 40 Mm Graded Stone Aggregate ) As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed. 5 Material And Labour Treating The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Att Chemical Emulsion Per Square Metre Of Vertical Surface ( Area Of The Sub Structure In Contact With Backfill To Be Measured ) Complete All As Specified And Directed. 6 Material And Labour Treating The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Att Chemical Emulsion Per Square Metre Of Surface Complete All As Specified And Directed. 7 Material And Labour Treating The Soil Under Plinth Protection At The Rate Of 5 Litres Of Att Chemicalemulsion Per Square Metre Of Surface Area Complete All As Specified And Directed. 8 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length Bent To Shape Required, Including Cranking Bending Spirally For Hooping For Columns , Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.90Mm Dia Or Securing With Clips Complete All As Specified And As Directed. 9 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia, Cut To Length Bent To Shape Required, Including Cranking Bending Spirally For Hooping For Columns , Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.90Mm Dia Or Securing With Clips Complete All As Specified And As Directed. 10 Material And Labour For Mild Steel Tmt Bars 5Mmdia. And Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.90Mm Dia Or Securing With Clips Complete All As Specified And Directed. 11 Material And Labour For Use And Waste Of Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter With Rough Finished Surfaces Of Concrete, Flat Complete All As Specified And As Directed. 12 Material And Labour For Use And Waste Of Form Work To Sides Of Pillars, Posts, Struts, Piers, Piers, Columns And Stanchions Of Square, Rectangular Or Polygonal Shapewith Rough Finished Surfaces Of Concretecomplete All As Specified And As Directed 13 M & L For Use And Waste Of Formwork To Faces Of Walls, Retaining Walls, Abutments, Parapets And Staircase Railings And Similar Work Including Attached Pillasters, Buttresses, Etc.; Vertical Or To Batter With Rough Finished Surfaces Of Concrete Flat Complete All As Specified And As Directed. 14 Material And Labour For Use And Waste Of Form Work To Soffits Of Suspended Slab Such As Roof Slabs, Floor Slabs, Landing And Similar Work, Etc. Not Exceeding 200Mm Thick With Rough Finished Surfaces Of Concrete Flat Complete All As Specified And As Directed. 15 Material And Labour For Use And Waste Of Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc With Rough Finished Surfaces Of Concrete Flat Complete All As Specified And As Directed. 16 Material And Labour For Use And Waste Of Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors, Window Cills, Concrete Railings, Openings In Concrete Walls, Floor And Roofs N Exc 20Cm Wide And Sides Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10Cm But N Exc 20Cm Wide With Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed. 17 Material And Labour For Reinforced Cement Concrete ( Design Mix ) In M-25 ( 20Mm Graded Aggregates ) For Foundation And Plinth Beams Etc Complete All As Specified And As Directed.Note:- ( I ) Reinforcement And Form Work Required Shall Be Measured And Paid Seperately ( Ii ) Design Mix Will Be Approved By The Ge. 18 Material And Labour For Rcc M-25 ( Design Mix ) ( Using 20Mm Graded Stone Aggregate ) As In Walls, Retaining Walls, Basement Walls, Ballast Walls And The Like, Any Thickness, Above Top Of Footings, Including Attached Pilasters And Buttresses Complete All As Specified And As Directed.Note:- ( I ) Reinforcement And Form Work Required Shall Be Measured And Paid Seperately ( Ii ) Design Mix Will Be Approved By The Ge. 19 Material And Labour For Reinforced Cement Concrete ( Design Mix ) In M-25, ( 20 Mm Graded Aggregate ) As In Columns / Pillars Complete All As Specified And As Directed.Note :- ( I ) Reinforcement And Form Work Required Shall Be Measured And Paid Seperately ( Ii ) Design Mix Will Be Approved By The Ge. 20 Material And Labourfor Reinforced Cement Concrete ( Design Mix ) In M-25 ( 20Mm Graded Aggregate ) For Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves Complete All As Specified And Directed.Note:- ( I ) Reinforcement And Form Work Required Shall Be Measured And Paid Seperately ( Ii ) Design Mix Will Be Approved By The Ge. 21 Material And Labourfor Reinforced Cement Concrete ( Design Mix ) In M-25 ( 20Mm Graded Aggregates ) For Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span Complete All As Specified And As Directed.Note:- ( I ) Reinforcement And Form Work Required Shall Be Measured And Paid Seperately ( Ii ) Design Mix Will Be Approved By The Ge. 22 Material And Labour For Rcc M-25 Design Mix, Using 20Mm Graded Stone Aggregate As In Chajjas And The Like Complete All As Specified And As Directed.Note:- ( I ) Reinforcement And Form Work Required Shall Be Measured And Paid Seperately ( Ii ) Design Mix Will Be Approved By The Ge. 23 Material And Labour Forbrick Work With Sub Class `B` Bricks, Old Size, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar ( 1:6 ) Complete All As Specified And As Directed. 24 Material And Labourfor Providing 40Mm Thick Pcc 1:2:4 Type B-0 As In Damp Proof Course Mixed With Water Proofing Compound As Per Manufacturer Instructions To Horizontal Or Vertical Surfaces Including Necessary Form Work Etc Complete All As Specified And Asdirected.Note: Wpc Shall Be Measured And Paid Seperately. 25 Materials And Labour For 15 Mm Thick Rendering On Fair Faces Of Brick Work Mixed With Water Proofing Compound As Per Manufacturer Instructions In Cement Mortar ( 1:4 ) On Wall Andfinished The Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed.Note: Wpc Shall Be Measured And Paid Seperately. 26 Materials And Labour For 10 Mm Thick Rendering On Other Than Fair Faces Of Brick Work Or Concrete Surface As On Wallin Cement Mortar ( 1:4 ) Andfinished The Surfaces Even And Smooth Without Using Extra Cementcomplete All As Specified And As Directed. 27 Materials And Labour For 10 Mm Thick Rendering On Other Than Fair Faces Of Brick Work Or Concrete Surface As On Wallin Cement Mortar ( 1:6 ) Andfinished The Surfaces Even And Smooth Without Using Extra Cementcomplete All As Specified And As Directed. 28 Material And Labourfor Rendering 5Mm Thick In Cm 1:3 On Ceiling On Fair Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Surfaces Complete All As Specified And Asdirected. 29 Supply Only Integral Liquid Water Proofing Compound ( Wpc ) Of Best Quality ( Isi Marked ) Completeall As Specified And As Directed. 30 M & L For Cleaning Surfaces To Receive The Water Proofing Treatment, Applying 15Mm Thick Plastering In Cm 1:4Mixed With Water Proofing Compound As Per Manufacturer Instructions In Cement Finished Even And Smoothand Curing For Seven Days And After Fully Dried Plastered Surfaces Cleaning The Plaster Surfaces, Applying One Coat Of Hot Paving Bitumen Of Penetrationvalue 85 / 25 Conforming To Is 73 @ 1.20 Kg / Sqm Over A Coat Of Bitumenous Primer @ 0.30 Ltrs Per Sqm And Applying A Layers Of App Based Polymeric Membrane, 3Mm Thick ( Minimum ) Weight 3.50 Kg / Sqm Reinforced With Polyster Non Woven Fabric ( Weighing Not Less Than 150 Gms / Sqm ) Shall Be Applied Overbitumenious Primer ( Application Of Polymeric Memberane Shall Be By Torch Application, Over Laps Shall Be Minimum 100Mm On The Transverse Direction & 75 Mm On The Longtudinaldirection ) Polymeric Membrane Shall Be Taken To A Height Of 60 Cm ( Minimum ) And Then Inserted Inside The Groove Of Parapet Wall And Shall Be Finished By Membrane Flashing, ( Conti.. ) 31 Coved Fillet In Pcc ( 1:2:4 ) Type B-0 Of Radius 75 Mmshall Be Provided At The Junction Of Roof & Other Vertical Surfacesand Surfaces Shall Be Painted With Hot Paving Bitumen Of Penetrationvalue 85 / 25 Conforming To Is 73 @ 1.20 Kg / Sqm & Applying One Coat Of Aluminium Paint Over The App Modified Membrane @ 0.11 Kg / Sqm Complete All As Specified And As Directed.Note: ( I ) Wpc Will Be Measured And Paid Separately. ( Ii ) Cutting Of Grooves Will Be Carried Out By Using Mechanical Means Like Groove Cutter / Wall Chaser. 32 Material And Labour For Sand Filling Under Floor Or Foundation Including Watering And Consolidation Complete All As Specified And Directed. ( Note: Punned Thickness To Be Measured For Payment Purpose ) 33 Supply And Fixing Polythene Film Black 50 Micron Laid In Floor Over Sand Layer Complete All As Specified And Directed. 34 Material And Labour For Broken Stone Hardcore Of Gauge N.Exc 63Mm, Granite Stone, Deposited, Spread And Levelled In Layers N.Exc 15Cm Thick, Watered And Rammmed To A True Surface Complete All As Specified And As Directed. 35 Material And Labour 75Mm Thick Pcc 1:4:8 Type D-2 ( Using 40 Mm Graded Stone Aggregate As Insub Base Flooring Finishing Even And Rough Including Necessary Formwork Complete All As Specified And Directed. 36 Material And Labour 25Mm Thick Plain Cement Concrete Type B 0, 1:2:4 ( 12.5Mm Graded Stone Agg ) As In Sub Base Finish The Surface Even And Rough To Receive Tiles Complete All As Specified And As Directed. 37 Material And Labour For 20-25Mm Thick Machine Cut Kota Stone Slab Flooring Over And Including 20Mm Thick Screed Bedin Cement Mortar ( 1:4 ) With Roughening Of Surface, Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Mirror Polishing Complete All As Specified And As Directed. 38 Material And Labour For 20-25 Mm Thick Machine Cut Kota Stone Slab Shall Be Laid On Skiriting / Dado / Vertical Surfaces, Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Colour / Shade Of The Slab Over And Including 10Mm Thick Plastering / Backing Coat In Cement Mortar ( 1:4 ) With Roughening Of Surface, Including Rubbing And Polishing Complete All As Specified And As Directed. 39 Material & Labour For 75Mm Thick, Pcc 1:3:6, Type C-1, Using 20Mm Graded Aggregate As In Plinth Protection Etc Surface Finished Even And Smooth Without Using Extra Cement And Providing Necessary Joints 12Mm Wide To The Full Depth Of Pcc At Every 3 Meters And Every Change Of Directions And The Joints Duly Filled With Mastic Filling Comprising Of 01 Part Of Heated Bitumen Blown Grade Any Penetration And 3 Parts Of Sand [ All By Weight ] Complete All As Specified And As Directed. 40 Materials And Labour For Preparation Of Newly Plastered Surfaces Of Ceiling And Applying Three Coats Of White Wash Complete All As Specified And As Directed. 41 Materials And Labour For Preparation Of New Plasteredsurfaces Of Walls And Applying Two Coats Of Oil Bound Distemper Over A Coat Of Chalk Whitening Primer Complete All As Specified And As Directed. 42 Material And Labourfor Preparation Of New External Plaster Surface Of Wall By Removing All Loose Adhering Powder Materials By Brushing Scraping And Water Jetting And Make The Surface Smooth Usingapplying Two Coat Of Weather Proof Paint Over A Coat Of Alkali Resistant Primer Complete All As Specified & Directed. 43 Material And Labour For Pcc 1:2:4 Type B1 ( Using 20 Mm Graded Stone Aggregate ) As In Lintels Upto 1.5M Clear Span, Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Including Necessary Use And Waste Of Formwork Complete All As Specified And As Directed. 44 S&F Pressed Steel Frames Of Size 105X60mm For Doors With One Or More Rebates Including Necessary Fixing Lugs , Hinges, Lock Strike Plate Etc Complete All As Specified And As Directed. 45 Supply And Fixing For 35Mm Thick Second Class Hardwood Plain Framed Panelled Shutters ( Any Numbers Of Panels ) With Panels Of Timber Flat Both Sides ( Feather Edged ) Or Of Veneered Particle Board Medium Dencity, Wood Particle With Commercial Face Veneers Supplied And Fitted To Chowkats Complete All As Specified And As Directed. 46 Supply And Fixing Steel Window With Side Hung Shutter Including Projecting Type Hings With Steel Handle And Steel Peg Stay Complete With Glazing Bars, Devetailed Or Welded Complete All As Specified And As Directed. 47 Supply And Fixing Sheet Glass Selected Quality 4.0Mm Thick, Any Size, Tinted Of Aproved Colour Fixed With Oil Putty Complete All As Specified And As Directed. 48 Material And Labour Forpreparation Of New Wooden Surface Exc 10 Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primercomplete All As Specified And As Directed. 49 Material And Labour For Preparation Of New Steel Surfaces To Receive Painting Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Chrome Primercomplete All As Specified And Directed. 50 Supply & Fixing 100 Mm Size Butt Hinges, Medium Weight, Cold Rolled Mild Steel Complete All As Specified And As Directed. 51 Supply And Fixing Extruded Aluminium Alloy Handles, Fabricated Type, Anodised 150Mm Size Complete All As Specified And As Directed. 52 Supply And Fixing Aluminium Anodized, Barrel Tower Bolts, 200Mm Long And 10Mm Dia Of Extruded Section Complete All As Specified And As Directed. 53 Supply And Fixing 250Mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Section Or Cast Aluminium Alloy And Fixed Complete All As Specified And As Directed. 54 Returning, Filling In, Of Soft / Loose Soil Including Spreading Leveling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Complete All As Specified And As Directed 55 Removing Excavated Soil To A Distance N.Exc 50M And Deposited / Spreaded Where Directed At A Level N. Exc 1.5 M Above The Starting Point Completeall As Specified And As Directed. 56 Material And Labour For 100 Mm Thick Plain Cement Concrete Type D-2, 1:4:8 ( Using 40Mm Graded Aggregate ) As In Hard Standing, Finished The Surface Fair And Rough Complete All As Specified. 57 Material And Labour For 150 Mm Thick Plain Cement Concrete Type B-2, 1:2:4 ( Using 20Mm Graded Aggregate ) As In Hard Standing, Finished The Surface Fair And Rough Complete All As Specified. 58 Material & Labour For Forming Contraction ( Dummy ) Joints 65Mm Deep X 10Mm Wide, Filled With Sealing Compound, Grade ‘B’ Complete All As Specified And Directed. 59 Material And Labour For Point Wiring, Concealed On Wall Or Ceiling For One Light / Fan Call Bell Point With 1.5 Sqmm Pvc Insulated ( Fr-Lsh ) Unsheathed Copper Cable Multistranded Conductor 1100 Volt Grade Controlled By One Way Switch Including 1.5 Sqmm Pvc ( Fr-Lsh ) Insulated Unsheathed Copper Cable Multistrand Conductor 1100 Volts Grade For Earth Continity Wire Connected To Common Earth Dolly Drawn Through And Including Pvc Rigid Conduit Of Adequate Size With All Accessories And The Cable Will Terminate To Modular Gi Box Suitable Size And Thickness Including Modular Type Base / Grid Frame And Cover Frame For Housing Modular Type Switches, Socket And Regulators Etc.Complete All As Specified Ans As Directed.Note:- ( I ) Red, Yellow And Blue Coloured Cable Shall Be Used For Live Connection, Black Coloured Cable Shall Be Used For Neutral Connection And Green Coloured Cable Shall Be Used For Earthing. Separate Cable For Earthing And Neutral To Be Used For Each Individual Circuit From The Distribution Board ( Ii ) Payment For Cutting Chases Shall Deemed To Be Included In The Quated Rate. 60 All As Per Item No 58 Above But For 3 Pin, 5 Amp Switch Socket Outlet On Independent Board Complete All As Specified And Directed. 61 All As Per Item No 58 Above But With 2.50 Sqmm Pvc Insulated ( Fr-Lsh ) Unsheathed Copper Cable Multistranded Conductor 1100 Volt Grade For 3 Pin, 15 Amp Switch Socket Outlet On Independent Board Complete All As Specified And Directed. 62 Supply & Fixing Switch Piano Flush Type ( Isi Marked ) , Single Pole, One Way 5 Amp, 240 Volts Complete All As Specified And Directed. 63 Supply & Fixing Switch Socket Combination 2 In 1, 3 Pin, 5 Amp Flush Type Universal Controlled By One Switch Flush Type Complete All As Specified And Directed. 64 Supply & Fixing Socket Outlet 2 In 1, 3 Pin 5 / 16 Amp, 5 In 1, Flush With Fuse And Neon Indicator All As Specified And Directed. 65 Supply & Fixing Ceiling Fan Regulator Socketed, Step Type, Flush Type Heavy Duty Suitable To Work On 230 Volts Ac Supply Complete All As Specified And As Directed 66 Supply And Fixing Ceiling Rose, Pvc / Polycarbonate, Isolated Body Surface Bakelite, 65Mm X 25Mm, Isi Marked Three Terminals Complete All As Specified And Directed. 67 Supply & Fixing Surface & Wall Mounted Energy Efficient Led Tube Light Fitting Of 20 Watt, 4 Feet Long, 5700 K Of Cool White, With Extruded Aluminium / Crca Housing And Robust Construction With Necessary Acrylic Diffuser & Integrated Electronic Driver, All Accessories Internally Prewired And Connecting Up With Twin Core Pvc Insulated, Sheathed Flexible Copper Conductor Cable Of Size 1.5 Sq.Mmcomplete All As Specified And As Directed. Note: Light Fitting Shall Be Of Pf>0.95 68 Supply & Fixing Energy Efficient & Long Life Building Security Light Luminaire, Of 25 Watt, 5700 K With Pressure Die Cast Aluminium Housing, Ip66 Protection, Heat Resistant Glass Cover, High Power Leds As Light Source, Electronic Driver Including Gi Bracket Made Out Of 25 Mm Bore Gi Tube, Medium Grade Of Size Not Exceeding 1.20 M In Length And Bent To Shape Required And Fixed Including Drilling In Wall Of Required Hole With 2 Nos Of Wall Fitting Clamps Made Out Of Ms Flat Of Size 50 X 6Mm, Bolts, Nuts, Washers And Painting With Two Coats Of Aluminium Paint Over A Coat Of Primer Red Oxide Zinc Chrome Primer And Connecting Up With Three Core Pvc Insulated, Sheathed Flexible Copper Conductor Cable Of Size 1.5 Sq.Mm Complete All As Specified And As Directed. Note: Light Fitting Shall Be Of Pf>0.95 69 Supply & Fixing Energy Efficient, Low Noise, Ceiling Fan, 1200Mm Sweep Of Any Colour As Approved, 03 Blades, Bee 5 Star Rated, With Bldc Motor, Copper Wound, 350 Rpm, With Double Ball Bearing, Conforming To Is - 374, Isi Marked, Suitable For Operation On Single Phase, 240 Volts, Ac, 50Hz, Including Down Rod, Canopies, Shackles, Safety Rope, Hanging Clamps, Bushes, Having P.F >0.95, Service Value >6.5, Air Delivery >215 Cmm, Power Consumption Less Than 35 Watt, Thd Less Than 5%Including Provision Of Electronic Speed Control Regulator Step Type, Including Connecting Up With Twin Core Pvc Insulated, Sheathed Flexible Copper Conductor Cable Of Size 1.5 Sq.Mm Complete All As Specified And As Directed. Note: Ceiling Fan Shall Be Provided With 03 Years Onsite Replacement Warranty. Rate Quoted Is Deemed To Be Including The Same And Nothing Shall Be Paid Extra On This Account. 70 Supply & Fixing Exhaust Fan, Steel Body Ac Single Phase 230V Of Size 300Mm Sweep, Heavy Duty With Blades, And Frame And Louvers, Copper Winding And Connecting To Ceiling Rose With 3 Core Flexible Copper Cable Including Making Holes On The Wall And Making Good To The Disturbed Surfaces Complete All As Specified And As Directed. 71 Supply And Fixing Of Mcb Db Spn 8 Ways, Powder Coated, Double Door, 230 Volts, Including Bus Bar Neutral Link, Earth Bar And Din Rail, For Fixing Mcb Of Various Rating Complete All As Specified And As Directed. 72 Supply And Fixing Mcb 32 Amps, Spn, 240V, 10Ka, C Curve Complete All As Specified And As Directed. 73 Supply And Fixing Mcb 6 To 32 Amps, Sp, 240V, 10Ka, B Curve Complete All As Specified And As Directed.Note:For Serial Item No 69 To 71: Mcb And Mcb Db Shall Be Of Same Make As Approved By Ge. 74 Material And Labour For Cross Arm Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Inclusive Of Two Coats Of Aluminium Paint Over A Coat Of Zinc Chrome Primer Complete All As Specified And As Directed. 75 Supply And Laying Under Ground Xlpe Insulated Pvc Sheathed ( Heavy Duty ) Armoured 1100 Volts Grade Aluminium Conductor Cable Of Size 16 Sqmm 2 Core Laid In Trenches Or Fixed To Wall / Pole / Ceiling As Per Is 7098 ( Part I ) Complete All As Specified And As Directed.Note:-Excavation And Earth Work, Sand Cushioning, Cable Protection Cover, Pipe Etc Shall Be Measured And Paid Seperately . 76 Materials And Labour For Sand Filling Around The Cable With Approved Quality Coarse Sand For Sand Cushioning Of Under Ground Cableincludingspreading And Punning Down To Desired Thickness Complete All As Specified And As Directed. ( Note: Punned Thickness Shall Be Measured For Payment Purpose ) 77 Material And Labour For Well Burnt Sub Class Old Size Burnt B Bricks ( Size 230Mm X 115Mm X 75Mm ) Laid Flat Width Wise Along The Length Of Cable For Cable Protection Complete All As Specified And As Directed. 78 Supply And Fixing 40 Mm Bore Dia Gi Pipe, Medium Grade Including All Fittings Laid Under Road Crossings Or Fixed To Wall / Pole / Laid In Floorcomplete All As Specified And Directed. 79 Materials And Labour For Earthing Complete With Galvanised Iron Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick, Burried Directly And Preferably Vertically In Ground, Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Ground Level Connetced With Galvanised Wire Of 4Mm Diaby Means Of Nuts, Bolts, Check Nuts And Washers Made Of Galvanised Iron Or Steel Earthing Lead To Be Protected By Galvanised Iron Pipe Of 15Mm Bore ( Light Grade ) And Other End Connected To Earthing Test Point Or Lightening Arrestor Or Main Controlling Switch As Directed Including Providing Funnel With 20Mm Bore Galvanised Iron Pipe ( Medium Grade ) , Wire Mesh, Charcoal Or Coke And Common Salt In Alternate Layer Of 15Cm ( Compacted Thickness ) All Round The Earth Electrode, Concrete Earth Pit In Pcc ( 1:3:6 ) Type C-1 ( With 20Mm Graded Aggregate ) , 50Mm Thick Precast Rcc ( 1:2:4 ) Cover Slab ( Re-Inforced With 8Mm Dia Tmt Bar @ 15 Cm C / C Bothways And Suitable Handle Made Of 10Mm Dia ) Including Necessary Earth Work In Excavation, Returning Filling And Removal Of Surplus Earth Upto A Distance Not Exceeding 50 M Etc All As Shown On Electrical Plate No. 3 Of Mes Schedule Part-I ( 2009 ) Complete Including Testing On Completionall As Specified And As Directed.Notes:- ( I ) Main Earthing Strip From Earth Plate Electrode To Rest Point Upto Length Of 7.5 Meters Length Shall Deemed To Be Included In The Unit Rate Quoted Against This Item. ( Ii ) On Testing After Completion If The Desired Resistenance Is Not Obtained The Contractor Shall Redo The Earthing Without Any Extra Cost To The Department.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Nov-2023 Date Date 11-12-2023
2 29-Nov-2023 BOQ and other BOQ 11-12-2023
3 11-Dec-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-12-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
INR 41 Lakhs /-

BOQ Items

Name of Work: PROVN OF STORE ROOM FOR XXX MT AT RANGAPAHAR MIL STN.
Sl. No. Item Description
1Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
2Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation,n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
3All as per item No 02 above but depth exc 1.5m but n.exc 3mcomplete all as specified and as directed.
4Material and labour for PCC (1:2:4) type B2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
5Material and labour treating the backfill in contact with foundation at the rate of 7.5 litres of ATT chemical emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
6Material and labour treating the top surface of filled earth at the rate of 5 litres of ATT chemical emulsion per square metre of surface complete all as specified and directed.
7Material and labour treating the soil under plinth protection at the rate of 5 litres of ATT chemicalemulsion per square metre of surface area complete all as specified and directed.
8Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
9Material and labour for mild steel TMT bars 6mm to 8mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
10Material and labour for Mild steel TMT bars 5mmdia. and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
11Material and labour for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, flat complete all as specified and as directed.
12Material and labour for use and waste of form work to sides of pillars, posts, struts, piers, piers, columns and stanchions of square, rectangular or polygonal shapewith rough finished surfaces of concretecomplete all as specified and as directed
13M & L for use and waste of formwork to faces of walls,retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter with rough finished surfaces of concrete flat complete all as specified and as directed.
14Material and labour for use and waste of form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar work, etc. not exceeding 200mm thick with rough finished surfaces of concrete flat complete all as specified and as directed.
15Material and labour for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc with rough finished surfaces of concrete flat complete all as specified and as directed.
16Material and labour for use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide with rough finished surfaces of concrete complete all as specified and as directed.
17Material and labour for reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) for foundation and plinth beams etc complete all as specified and as directed. Note:-(i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE.
18Material and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilasters and buttresses complete all as specified and as directed. Note:-(i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE.
19Material and labour for Reinforced cement concrete (design mix) in M-25, (20 mm graded aggregate) as in columns/pillars complete all as specified and as directed.Note :- (i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE.
20Material and labourfor reinforced cement concrete (design mix) in M-25 (20mm graded aggregate) for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. Note:- (i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE.
21Material and labourfor reinforced cement concrete (design mix) in M-25 (20mm graded aggregates) for beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. Note:- (i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE.
22Material and labour for RCC M-25 Design Mix, using 20mm graded stone aggregate as in Chajjas and the like complete all as specified and as directed. Note:- (i) Reinforcement and form work required shall be measured and paid seperately (ii) Design mix will be approved by the GE.
23Material and labour forbrick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
24Material and labourfor Providing 40mm thick PCC 1:2:4 type B-0 as in Damp Proof course mixed with water proofing compound as per manufacturer instructions to horizontal or vertical surfaces including necessary form work etc complete all as specified and asdirected. Note: WPC shall be measured and paid seperately.
25Materials and labour for 15 mm thick rendering on fair faces of brick work mixed with water proofing compound as per manufacturer instructions in cement mortar (1:4) on wall andfinished the surfaces even and smooth without using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid seperately.
26Materials and labour for 10 mm thick rendering on other than fair faces of brick work or concrete surface as on wallin cement mortar (1:4) andfinished the surfaces even and smooth without using extra cementcomplete all as specified and as directed.
27Materials and labour for 10 mm thick rendering on other than fair faces of brick work or concrete surface as on wallin cement mortar (1:6) andfinished the surfaces even and smooth without using extra cementcomplete all as specified and as directed.
28Material and labourfor rendering 5mm thick in CM 1:3 on ceiling on fair faces of brick work or concrete surfaces, finished even and smooth without using extra surfaces complete all as specified and asdirected.
29Supply only integral liquid water proofing compound (WPC) of best quality (ISI marked) completeall as specified and as directed.
30M & L for cleaning surfaces to receive the water proofing treatment, applying 15mm thick plastering in CM 1:4mixed with water proofing compound as per manufacturer instructions in cement finished even and smoothand curing for seven days and after fully dried plastered surfaces cleaning the plaster surfaces, applying one coat of hot paving bitumen of penetrationvalue 85/25 conforming to IS 73 @ 1.20 kg/sqm over a coat of bitumenous primer @ 0.30 ltrs per sqm and applying a layers of APP based polymeric membrane, 3mm thick (minimum) weight 3.50 Kg/sqm reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) shall be applied overBitumenious primer (Application of polymeric memberane shall be by torch application, over laps shall be minimum 100mm on the transverse direction & 75 mm on the longtudinaldirection) polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by membrane flashing, (conti..)
31coved fillet in PCC (1:2:4) type B-0 of radius 75 mmshall be provided at the junction of roof & other vertical surfacesand surfaces shall be painted with hot paving bitumen of penetrationvalue 85/25 conforming to IS 73 @ 1.20 kg/sqm & applying one coat of aluminium paint over the APP modified membrane @ 0.11 kg/sqm complete all as specified and as directed. Note: (i) WPC will be measured and paid separately. (ii) Cutting of grooves will be carried out by using mechanical means like groove cutter/wall chaser.
32Material and labour for sand filling under floor or foundation including watering and consolidation complete all as specified and directed. (Note: Punned thickness to be measured for payment purpose)
33Supply and fixing polythene film black 50 micron laid in floor over sand layer complete all as specified and directed.
34Material and labour for broken stone hardcore of gauge n.exc 63mm,granite stone, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface complete all as specified and as directed.
35Material and labour 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate as insub base flooring finishing even and rough including necessary formwork complete all as specified and directed.
36Material and labour 25mm thick plain cement concrete type B 0, 1:2:4 (12.5mm graded stone agg) as in sub base finish the surface even and rough to receive tiles complete all as specified and as directed.
37Material and labour for 20-25mm thick machine cut kota stone slab flooring over and including 20mm thick screed bedin cement mortar (1:4)with roughening of surface, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
38Material and labour for 20-25 mm thick machine cut kota stone slab shall be laid on skiriting / dado / vertical surfaces,laid and jointed with grey cement slurry mixed with pigment to match the colour / shade of the slab over and including 10mm thick plastering / backing coat in cement mortar (1:4)with roughening of surface, including rubbing and polishing complete all as specified and as directed.
39Material & Labour for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth without using extra cement and providing necessary joints 12mm wide to the full depth of PCC at every 3 meters and every change of directions and the joints duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
40Materials and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
41Materials and labour for preparation of new plasteredsurfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed.
42Material and labourfor preparation of new external plaster surface of wall by removing all loose adhering powder materials by brushing scraping and water jetting and make the surface smooth usingapplying two coat of weather proof paint over a coat of alkali resistant primer complete all as specified & directed.
43Material and labour for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary use and waste of formwork complete all as specified and as directed.
44S&F Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs , hinges, lock strike plate etc complete all as specified and as directed.
45Supply and fixing for 35mm thick second class hardwood plain framed panelled shutters (any numbers of panels) with panels of timber flat both sides (feather edged) or of veneered particle board medium dencity, wood particle with commercial face veneers supplied and fitted to chowkats complete all as specified and as directed.
46Supply and fixing steel window with side hung shutter including projecting type hings with steel handle and steel peg stay complete with glazing bars,devetailed or welded complete all as specified and as directed.
47Supply and fixing sheet glass selected quality 4.0mm thick, any size,tinted of aproved colour fixed with oil putty complete all as specified and as directed.
48Material and labour forpreparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and as directed.
49Material and labour for preparation of new steel surfaces to receive painting over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primercomplete all as specified and directed.
50Supply & fixing 100 mm size Butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
51Supply and fixing extruded aluminium alloy handles, fabricated type, anodised 150mm size complete all as specified and as directed.
52Supply and fixing aluminium anodized, barrel tower bolts, 200mm long and 10mm dia of extruded section complete all as specified and as directed.
53Supply and fixing 250mm long Aluminium alloy, anodised, sliding door bolt with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixed complete all as specified and as directed.
54Returning, filling in, of soft/loose soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed
55Removing excavated soil to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point completeall as specified and as directed.
56Material and labour for 100 mm thick Plain Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in hard standing, finished the surface fair and rough complete all as specified.
57Material and labour for 150 mm thick Plain Cement concrete type B-2, 1:2:4 (using 20mm graded aggregate) as in hard standing, finished the surface fair and rough complete all as specified.
58Material & Labour for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, Grade ‘B’ complete all as specified and directed.
59Material and labour for point wiring, concealed on wall or ceiling for one light/fan call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volt grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continity wire connected to common earth dolly drawn through and including PVC rigid conduit of adequate size with all accessories and the cable will terminate to modular GI box suitable size and thickness including modular type base/ Grid frame and cover frame for housing modular type switches, Socket and regulators etc.complete all as specified ans as directed. Note:- (i)Red,yellow and Blue coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. separate cable for earthing and neutral to be used for each individual circuit from the distribution board (ii) payment for cutting chases shall deemed to be included in the quated rate.
60All as per item No 58 above but for 3 pin,5 Amp switch Socket outlet on independent board complete all as specified and directed.
61All as per item No 58 above but with 2.50 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volt grade for 3 pin,15 Amp switch Socket outlet on independent board complete all as specified and directed.
62Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified and directed.
63Supply & fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal controlled by one switch flush type complete all as specified and directed.
64Supply & Fixing socket outlet 2 in 1, 3 pin 5/16 Amp,5 in 1,flush with fuse and neon indicator all as specified and directed.
65Supply & Fixing ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply complete all as specified and as directed
66Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 65mm x 25mm,ISI marked three terminals complete all as specified and directed.
67Supply & Fixing Surface & wall mounted Energy efficient LED Tube Light Fitting of 20 watt, 4 feet long,5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mmcomplete all as specified and as directed. Note: Light fitting shall be of PF>0.95
68Supply & Fixing Energy efficient & Long life Building Security Light Luminaire, of 25 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 25 mm bore GI Tube, Medium Grade of size not exceeding 1.20 m in length and bent to shape required and fixed including drilling in wall of required hole with 2 Nos of wall fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
69Supply & Fixing Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep of any colour as approved, 03 blades, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 374, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, including Down Rod, Canopies, Shackles, Safety Rope, Hanging Clamps, Bushes, having P.F >0.95, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5%including provision of Electronic speed control Regulator step type, including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Ceiling Fan shall be provided with 03 Years onsite replacement warranty. Rate quoted is deemed to be including the same and nothing shall be paid extra on this account.
70Supply & Fixing exhaust fan, steel body AC single Phase 230V of size 300mm sweep, Heavy duty with blades, and frame and louvers, copper winding and connecting to ceiling rose with 3 core flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and as directed.
71Supply and fixing of MCB DB SPN 8 ways, powder coated, double door, 230 Volts,including bus bar neutral link, earth bar and din rail,for fixing MCB of various rating complete all as specified and as directed.
72Supply and fixing MCB 32 Amps, SPN, 240V, 10KA, "C" curve complete all as specified and as directed.
73Supply and fixing MCB 6 to 32 Amps, SP, 240V, 10KA, "B" curve complete all as specified and as directed. Note:for serial Item No 69 to 71: MCB and MCB DB shall be of same make as approved by GE.
74Material and labour for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed.
75Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 2 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) complete all as specified and as directed. Note:-Excavation and earth work,sand cushioning,cable protection cover,pipe etc shall be measured and paid seperately .
76Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
77Material and labour for well burnt sub class old size burnt "B" bricks (size 230mm x 115mm x 75mm) laid flat width wise along the length of cable for cable protection complete all as specified and as directed.
78Supply and fixing 40 mm bore dia GI pipe, medium grade including all fittings laid under road crossings or fixed to wall/ pole/laid in floorcomplete all as specified and directed.
79Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completionall as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail