Deparment Of Technical Education-DTE has published Purchase Of Measuring Instruments For Power System Lab In Electrical And Electronics Engineering Education Department. Submission Date for this Tender is 04-12-2023. Ammeters Tenders in palakkad Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

40652855
Purchase Of Measuring Instruments For Power System Lab In Electrical And Electronics Engineering Education Department
Open Tender
Indian
Kerala
palakkad
04-12-2023

Tender Details

Purchase Of Measuring Instruments For Power System Lab In Electrical And Electronics Engineering Education Department. , Ammetermi 0-2 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-5 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-10 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-15 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-20 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-30 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-50 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-2.5 / 5A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-10 / 20 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammetermi 0-15 / 30 A Portable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-50 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-75 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-150 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-250 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-300 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-500 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-600 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-50 / 75 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-75 / 150 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-150 / 300 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmetermi0-250 / 500 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-1 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-2 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-5 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-15 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-1 / 2 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-2.5 / 5 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-10 / 20 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc10a-0-10Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmeter Mc0-10 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmeter Mc0-15 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmeter Mc0-150 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmeter Mc0-250 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmeter Mc0-300 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmeter Mc0-15 / 30 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Voltmeter Mc0-150 / 300 Vportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Upf75v, 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Upf125 / 250 / 500 V , 2.5 / 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Upf150 / 300 / 600 V, 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Upf150 / 300 / 600 V, 10 / 15 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Upf150 / 300 / 600 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Upf75 / 150 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Lpf125 / 250 / 500 V, 2.5 / 5 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Lpf125 / 250 / 500 V, 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Lpf125 / 250 / 500 V, 10 / 20 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Lpf125 / 250 / 500 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Lpf150 / 300 / 600 V, 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Lpf150 / 300 / 600 V, 10 / 20 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1F Wattmeter Lpf150 / 300 / 600 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-10 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-50 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-100 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-500 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-10?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-100?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-300?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mi0-500 ?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-10 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-50 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-100 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-500 Maportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-10?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-100?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-300?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Ammeter Mc0-500 ?Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Upf Centre Zero Type75v, 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Upf Centre Zero Type125 / 250 / 500 V , 2.5 / 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Upf Centre Zero Type150 / 300 / 600 V, 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Upf Centre Zero Type150 / 300 / 600 V, 10 / 15 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Upf Centre Zero Type150 / 300 / 600 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Upf Centre Zero Type75 / 150 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Lpf Centre Zero Type125 / 250 / 500 V, 2.5 / 5 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Lpf Centre Zero Type125 / 250 / 500 V, 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Lpf Centre Zero Type125 / 250 / 500 V, 10 / 20 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Lpf Centre Zero Type125 / 250 / 500 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Lpf Centre Zero Type150 / 300 / 600 V, 5 / 10 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Lpf Centre Zero Type150 / 300 / 600 V, 10 / 20 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , 1Fwattmeter Lpf Centre Zero Type150 / 300 / 600 V, 15 / 30 Aportable Moving Iron Ammeters Must Be Housed In Bakelite Casewith Knife Edge Pointer &Antiparallaxmirror, Scale Of 140Mm ( Approx. ) Length , Quick Response , Rated Accuracy : Class 1.0 ( 1% Of Full Scale Value ) As Per Is 1248-84 , Rheostat20 O, 10 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Rheostat9 O, 8 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Rheostat1000 O, 1.2 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Rheostat50 O, 5 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Rheostat100 O, 5 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Rheostat145 O, 2.5 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Rheostat50 O, 10 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Rheostat270 O, 2.5 Athe Rheostat Should Be Wire Wound Sliding Rheostats With Best Quality Cu / Ni Or Ni / Cr Alloy Ressistance Wire Having Very Low Temp.Coefficient And Wire Is Protected With High Temperature Ressistance Compound. The Winding Should Be On Vitreous Enammelled Steel Tube Or Vetrified Ceramic Fitted With Aluminium Die Cast Stands / Fabricated Steel Stands. Contact Should Be Of Phosphor Bronze Or Self Lubricating Copper Graphite Fitted On Brass Slider, Slides On Solid Drawn Brass Rods , Stop Watch Analog , Stop Watch Digital , Power Factor Meter Analog , Power Factor Meter Digital , Digital Multi Meter , Clip On Ammeter Digital0-100A , Single Phase Auto Transformerinput Voltage: 230V, 1 Phase, 50 Hz;Output Voltage:0 - 270 V, 15A , Three Phase Auto Transformeroperating Voltage: 0 - 415 - 440 Volts; Standard Output Voltage: 0 - 470 Volts

Key Value

Document Fees
INR 1770 /-
EMD
INR 9188.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PURCHASE OF MEASURING INSTRUMENTS FOR POWER SYSTEM LAB IN ELECTRICAL AND ELECTRONICS ENGINEERING EDUCATION DEPARTMENT
Sl. No. Item Description
1AmmeterMI 0-2 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
2AmmeterMI 0-5 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
3AmmeterMI 0-10 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
4AmmeterMI 0-15 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
5AmmeterMI 0-20 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
6AmmeterMI 0-30 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
7AmmeterMI 0-50 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
8AmmeterMI 0-2.5/ 5A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
9AmmeterMI 0-10/20 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
10AmmeterMI 0-15/30 A Portable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
11VoltmeterMI0-50 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
12VoltmeterMI0-75 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
13VoltmeterMI0-150 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
14VoltmeterMI0-250 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
15VoltmeterMI0-300 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
16VoltmeterMI0-500 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
17VoltmeterMI0-600 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
18VoltmeterMI0-50/75 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
19VoltmeterMI0-75/150 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
20VoltmeterMI0-150/300 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
21VoltmeterMI0-250/500 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
22Ammeter MC0-1 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
23Ammeter MC0-2 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
24Ammeter MC0-5 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
25Ammeter MC0-10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
26Ammeter MC0-15 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
27Ammeter MC0-30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
28Ammeter MC0-1/2 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
29Ammeter MC0-2.5/5 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
30Ammeter MC0-5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
31Ammeter MC0-10/20 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
32Ammeter MC0-15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
33Ammeter MC10A-0-10APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
34Voltmeter MC0-10 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
35Voltmeter MC0-15 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
36Voltmeter MC0-150 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
37Voltmeter MC0-250 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
38Voltmeter MC0-300 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
39Voltmeter MC0-15/30 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
40Voltmeter MC0-150/300 VPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
411f Wattmeter UPF75V, 30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
421f Wattmeter UPF125/250/500 V , 2.5/5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
431f Wattmeter UPF150/300/600 V, 5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
441f Wattmeter UPF150/300/600 V, 10/15 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
451f Wattmeter UPF150/300/600 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
461f Wattmeter UPF75/150 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
471f Wattmeter LPF125/250/500 V, 2.5/5 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
481f Wattmeter LPF125/250/500 V, 5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
491f Wattmeter LPF125/250/500 V, 10/20 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
501f Wattmeter LPF125/250/500 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
511f Wattmeter LPF150/300/600 V, 5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
521f Wattmeter LPF150/300/600 V, 10/20 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
531f Wattmeter LPF150/300/600 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
54Ammeter MI0-10 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
55Ammeter MI0-50 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
56Ammeter MI0-100 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
57Ammeter MI0-500 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
58Ammeter MI0-10µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
59Ammeter MI0-100µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
60Ammeter MI0-300µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
61Ammeter MI0-500 µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror,Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
62Ammeter MC0-10 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
63Ammeter MC0-50 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
64Ammeter MC0-100 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
65Ammeter MC0-500 mAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
66Ammeter MC0-10µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
67Ammeter MC0-100µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
68Ammeter MC0-300µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
69Ammeter MC0-500 µAPortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
701fWattmeter UPF centre zero type75V, 30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
711fWattmeter UPF centre zero type125/250/500 V , 2.5/5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
721fWattmeter UPF centre zero type150/300/600 V, 5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
731fWattmeter UPF centre zero type150/300/600 V, 10/15 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
741fWattmeter UPF centre zero type150/300/600 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
751fWattmeter UPF centre zero type75/150 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
761fWattmeter LPF centre zero type125/250/500 V, 2.5/5 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
771fWattmeter LPF centre zero type125/250/500 V, 5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
781fWattmeter LPF centre zero type125/250/500 V, 10/20 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
791fWattmeter LPF centre zero type125/250/500 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
801fWattmeter LPF centre zero type150/300/600 V, 5/10 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
811fWattmeter LPF centre zero type150/300/600 V, 10/20 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
821fWattmeter LPF centre zero type150/300/600 V, 15/30 APortable Moving Iron ammeters must be housed in bakelite casewith knife Edge Pointer &antiparallaxmirror, Scale of 140mm(approx.) length , quick response ,Rated Accuracy : Class 1.0 (1% of full scale value) as per IS 1248-84
83Rheostat20 ?, 10 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
84Rheostat9 ?, 8 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
85Rheostat1000 ?, 1.2 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
86Rheostat50 ?, 5 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
87Rheostat100 ?, 5 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
88Rheostat145 ?, 2.5 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
89Rheostat50 ?, 10 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
90Rheostat270 ?, 2.5 AThe rheostat should be wire wound sliding rheostats with best quality Cu/Ni or Ni/Cr alloy ressistance wire having very low temp.coefficient and wire is protected with high temperature ressistance compound. The winding should be on vitreous enammelled steel tube or vetrified ceramic fitted with aluminium die cast stands/ fabricated steel stands. Contact should be of Phosphor bronze or self lubricating copper graphite fitted on brass slider, slides on solid drawn brass rods
91Stop watch analog
92Stop watch digital
93Power factor meter analog
94Power factor meter digital
95Digital multi meter
96Clip on ammeter digital0-100A
97Single phase Auto transformerInput Voltage: 230V, 1 Phase, 50 Hz;Output voltage:0 - 270 V, 15A
98Three phase Auto transformerOperating Voltage: 0 - 415 - 440 Volts; Standard Output Voltage: 0 - 470 Volts